Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 CrAccepted-AOC MANATHA ENCLAVE 3RD FLOOR OLIMUGAL KAKKANAD P O KOCHI 682 030 KERALA | ERNAKULAM | KERALA | 682030 | ₹26.3 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹26.9 CrRejected-Finance | ₹26.9 Cr | L2 | Rejected-Finance Rejected being L2 |
| 3 | L3₹27.7 CrRejected-Finance 216 C SIVA COLONY MAYO LINK ROAD AJMER RAJASTHAN 305007 | AJMER | RAJASTHAN | 305007 | ₹27.7 Cr | L3 | Rejected-Finance Rejected being L3 |
| 4 | L4₹27.9 CrRejected-Finance 17 1624A MUMDAMVELI KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | ₹27.9 Cr | L4 | Rejected-Finance Rejected being L4 |
Tender Value
₹27.8 Cr
EMD Value
₹15 L
Closing Date
12 Sept 2020, 6:00 pmClosed
CE NW KOCHI
CE NW KOCHI KATARIBAGH NAVAL BASE P O KOCHI682004
PROVISION OF DEFICIENT MARRIED ACCN (74 DUs) FOR DSC JCOs AND ORs AT NAVAL BASE,KOCHI.
2020_MES_361180_1
890947/E8
Open Tender
Civil Works
700 days
KOCHI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE P KOCHI
₹15 L
Yes
20 Feb 2021
15 Jul 2020
15 Sept 2020
15 Jul 2020
12 Sept 2020
28 Aug 2020
16 Jul 2020 - 6 Aug 2020
Amount
LIST OF WORKS
Schedule A Part I to Part XIV
Total amount of Sch 'A' part-I (Buildings & Works)
Total amount of Sch 'A' part-I(A) (Buildings & Works)
Total amount of Sch 'A' part-II ( Excavation/Earthwork & Site Development)
Total amount of Sch 'A' part-III (Internal water supply)
Total amount of Sch 'A' part-IV (Internal Electrification)
Total amount of Sch 'A' part-V (External Water Supply)
Total amount of Sch 'A' part-VI (External Electrification)
Total amount of Sch 'A' part-VII(Road,Path Culvert and Hardstanding)
Total amount of Sch 'A' part-VIII(Sewage Disposal)
Total amount of Sch 'A' part-IX (Area Drainage)
Total amount of Sch 'A' part-X(Lightning Protection)
Total amount of Sch 'A' part-XI(Firefighting)
Total amount of Sch 'A' part-XII(Standby DG set)
Total amount of Sch 'A' part-XIII(Demolition and Dismantling)
Sch 'A' Part- XIV(MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Boring for cast-in-situ bored piles of 500mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Boring for cast-in-situ bored piles of 600mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
Boring for cast-in-situ bored piles of 700mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:-The rate shall include mobilisation,erection,dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
RCC with ready mix concrete(RMC) M30 grade with min 400Kg cement per cum in cast in situ bored pile of any length/any sections complete all as specified and as shown on drg including non destructive integrity test on all pile as per IS 2911 part IV.Note:-(i) Reinforcement will be measured and paid separately under relevant items
RCC with ready mix concrete(RMC) M30 grade in pile cap , grade beam & tie beam complete all as specified and shown on drg. Note:-(i) Reinforcement will be measured and paid separately under relevant items
CRS/HCRS/CRM TMT bars in reinforcement 10mm dia and over for bored pile including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs .
CRS/HCRS/CRM TMT bars in reinforcement 10mm dia and over including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs as in grade beams, tie beam,slab and pile caps.
CRS/HCRS/CRM TMT bars 5mm to 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and shown on drgs as in stirrups of grade beams.
CRS/HCRS/CRM TMT bars 5mm to 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and shown on drgs as in Helical.
PCC (1:4:8) type D2 using 40mm graded stone aggregate for concrete layer below pile caps/grade beams and foundation complete all as specified and shown on drgs.
Providing testing equipment & load and testing of 500mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 600mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 700mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 500mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 600mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 700mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Conducting Standard Panetration Test all as per IS-2131 at levels and locations as directed for 500, 600 and 700mm dia cast in situ bored piles completed all as specified and directed.
Formwork to sides of pile caps , grade beams rough finished surface of concrete flat all as specified .
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep or area not exceeding 10 sqm on plan in soft/loose soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engr-in-Charge for pile caps/plinth beams/tie beam etc all as specified and shown on drawings.
Returning filling in around pile cap, plinth beams, raft foundation etc using excavated soil including spreading levelling and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of excavated soil to a distance exceeding 1.5Km but not exc. 5.0Km and depositing where directed complete all as specified and as directed.
Internal Water Supply:- Stop cock, 25mm bore with wall flange ceramic disc cartridge with plain knob of Make Jaquar Cat part No. CQT-24081 or equivalent of other make specified in the list of manufacturer complete all as specified and as directed.
Angular stop cock, 15mm bore with wall flange of make Jaquar Cat part No. CQT-23059 or equivalent of other make specified in the list of manufacturer complete all as specified and as directed.
Stop cock long body combination of exposed part kit of concealed stop cock with fitting sleeve,operating knob,adjustable wall flange and regular body concealed stop cock suitable for 15 mm pipe line with protection of Make: Jaquar Cat part No. CQT-2308K and ALD 083 or equivalent of other make specified in the list of manufacturer complete all as specified and as directed.
Bib tap with wall flange complete of make : Jaquar Cat part No. SQ-8744 or equivalent of other make specified in the list of manufacturer complete all as specified and as directed
Health faucet/hand shower with 8 mm dia,wall hook and easy flexible tube in crome finish 1.5m long with nuts complete of make : Jaquar Cat part No ALD573 and SHA 571 or equivalent of other make specified in the list of manufacturer complete all as specified and as directed
Two way wall mixer tap wall mounted 2 in 1 system with provision for over head shower with 115mm long blend pipe on upper side connecting leg and wall flanges, complete of make : Jaquar Cat part No CQT 23073UPR or equivalent of other make specified in the list of manufacturer complete all as specified and as directed
Hot water braided pipe 450 mm long with two 15mm nut and rubber washer without nipple,complete of Make: Jaquar Code NoALD805B or equivalent of other make specified in the list of manufacturer complete all as specified and as directed.
Overhead shower rose 100mm dia round shape single flow ABS body chrome plated with grey face plate and Rub/cleaning system and shower arm casted 120mm long heavy body round shape for wall mounted shower with wall flange complete make : Jaquar Code No OHS 1989 and SHA or equivalent of other make specified in the list of manufacturer complete all as specified and as directed
Internal Electrification:- Concealed point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked and including heavy duty, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked (IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) , including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly cutting chasis,and making good disturbed surfaces etc complete all as specified & directed for (a) One light /ceiling fan / exhaust fan/bell point controlled by one 5/6 amps one way switch ( Note :(ii): Rate include the logic modular plates, Necessary blank Plates as required at site. ) complete all as specified and directed for one light point controlled by one switch
All as per item No.47 above but for One Socket outlet, three/five pin, 5 Amp, on independent board controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin.
All as per item No.47 above but for One Socket outlet, three/five pin, 5 Amp, controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin, on the same board with other switches, sockets, fan regulators etc.
Concealed point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 2.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked and including heavy duty, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked (IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) , including PVC insulated multi-stranded copper conductor 2.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly cutting chasis, and making good disturbed surfaces etc., complete all as specified & directed-Independent board for the one 3/5 pin 15/16 amps socket outlet independent.(Note:-Switch and socket to be measured and paid for seperately)
Ceiling fan,copper wound,1200mm sweep having service value not less than 4.5, including fixing of down rod of any length suitable from ceiling, canopy, mounting clamp etc.Ac,230 V,and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.50 Sq mm from ceiling rose/ connector to fan Make shall be either of Crompton Greaves/Usha/Orient ) complete all as specified and as directed. Note:-Rate quoted shall deemed to be included for suitable length of down rod from roof to false ceiling as directed by engineer in charge
Exhaust fan 250 mm sweep 230 Volts AC 50 Hz PVC body with copper wound motors and PVC louvers, including connecting up from ceilinf rose with 3 core flexible copper cable, PVC sheathed of size 1.5 sqmm.(Make : Make shall be either of Crompton Greaves/Usha/ Almonard ) complete all as specified and as directed.
LED Tube light 1x20 Watt universal batten type with and including connecting 3 core 1 sqmm PVC insulated multistranded copper conductor colour of sheve matching to fitting and connecting from ceiling rose to fitting complete all as specified and as directed.Note:- Fitting:Crompton Cat Part No.lGP161LT8-16 or equivalent make of Philips/Wipro.Lamp:Crompton Cat Part No.LTT8-20 or equivalent make of Philips/Wipro.
Sleek LED light 1x10 Watt 2 feet with and including connecting 3 core 1 sqmm PVC insulated multistranded copper conductor colour of sheve matching to fitting and connecting from ceiling rose to fitting complete all as specified and as directed.Note:- Fitting:Crompton Cat Part No.LDL-10-CDL or equivalent make of Philips/Wipro.Lamp:Crompton Cat Part No.LT8-8-562-2 or equivalent make of Philips/Wipro.
Sleek LED mirror light 1x07 Watt 1 feet with and including connecting 3 core 1 sqmm PVC insulated multistranded copper conductor colour of sheve matching to fitting and connecting from ceiling rose to fitting complete all as specified and as directed.Note:- Fitting with Lamp:Crompton Cat Part No.LCL-07-CDL or equivalent make of Philips/Wipro.
LED bulb, 9W,suitable for and including B22 angle hoder/batten holder of make Philips or equivalent in CG/Wipro
Security light fitting presssure die cast aluminium housing heat resistance toughned glass having IP 65 protection of 35 watt complete including fixing with GI bracket made of 43 mm dia GI pipe including fixing clamps etc complete . Make: Philip's Model No.BRP050LED 036CWR1MFPCS1PSU GR or equivalent of Crompton Greaves / Wipro.
LED bulk head fittings with IP 65 protection suitable for surface and wall mounting applications complete all as specified and as directed. Make: Philip's Model No.WT140W LED 7S CW PSU S1 PC or equivalent of Crompton Greaves / Wipro.
MCB DB SPN 1 way single door 240 volts without busbar of make:Legrand/Schiender/L&T complete all as specified and as directed.
MCB DB SPN 8 way double door 240 volts with 200 Amps rated busbar of make:Legrand/Schiender/L&T complete all as specified and as directed.
MCB DB SPN 12 way double door 240 volts with 200 Amps rated busbar of make:Legrand/Schiender/L&T complete all as specified and as directed.
MCB SP 6-32 Amps 10 KA with ''B'' curve of make:Legrand/Schiender/ L&T complete all as specified and as directed.
MCB SPN 6-32 Amps 10 KA with ''B'' curve of make:Legrand/Schiender/ L&T complete all as specified and as directed.
RCBO DP 30 ma of 32 Amps 240 V of make:Legrand/Schiender/ L&T complete all as specified and as directed.
MCB SPN 40 Amps 10 KA with ''C'' curve of make: Legrand/ Schiender/ L&T complete all as specified and as directed.
Single pole and neutral enclosure with a two pin and earth plug with socket complete with one single pole MCB 20 Amps,230 volts,50 Hz complete all as specified and as directed.
Submain wiring with 2.5 sq mm two single core(for phases and neutral) using multistranded copper conductor as per IS 694 PVC (FR) insulated unsheathed with and including 2.5 sq mm insulated unsheathed PVC insulated multistranded copper conductor as earth continuity conductor connected to common earth dolly drawn in and inluding non metallic rigid PVC conduit, ISI marked, with all accessories of size not less than 20 mm dia complete all as specified and as directed by Engineer-in-Charge. (Note: Three runs of 2.5 sqmm copper conductor and one run of PVC concealed conduit shall be measured as one run only)
All as per item No.68 above but in surface conduit including fixing accessories (Sub main in shaft)
Submain wiring with 6 sq mm two single core(for phases and neutral) using multistranded copper conductor as per IS 694 PVC (FR) insulated unsheathed with and including 6 sq mm insulated unsheathed PVC insulated multistranded copper conductor connected to common earth dolly drawn in and including non metallic rigid PVC conduit, ISI marked, with all accessories of size not less than 20 mm dia and earth conductor connected to common earth dolly all as specified and as directed by Engineer-in-Charge. (Note: Three runs of 6 sqmm copper conductor and one run of PVC concealed conduit shall be measured as one run only)
All as per item No.70 above but in surface conduit including fixing accessories (Sub main in shaft)
EXTERNAL WATER SUPPLY:-.Cutting the existing DI water mains 250 mm dia and inserting Tee 250 x 250 x 100 mm for taking up branch connection including DI fittings and jointing material as required and necessary excavation/earth work complete all as specified and as directed.
Ductile Iron pipes 100 mm dia centrifugally cast (spun), Class K-9, with spigot and socket ends conforming to IS 8329/2000 in any length suitable for push-on joints , laid in trenches complete all as specified and as directed.
DI fittings such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs suitable upto 200mm dia, class K-12 complete all as specified and directed.
Construction of brick masonry valve chamber of internal dimensions 900 x 900 x 900 mm, bottom floor of the pit shall be constructed in PCC (1:3:6) 15 cm thick with 20 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 mm thick. The top cover of the pit shall be made out of MS sheet min 3 mm thick with angle iron frame made out of MS angle 40 mm x 40 mm x 6 mm with 02 nos steel hinges and locking arrangements duly painted with two coats of synthetic enamel paint over one coat of red oxide primer all as specified and as directed complete all as specified and as directed.
Supply, install, test and commissioning Pump set mono block type, 36 mtr head, 12 LPS (Approx 10 HP), electric driven 3 phase, 415 V including PCC foundation, platform, MS base frame with fixing nut bolts, adequate length of suitable suction pipe of CPVC with jointing arrangement complete all as specified and as directed.
Motor control panel indoor type made out of MS sheet 2 mm thick with locking arrangement and painting with following accessories suitable for incoming/outgoing arrangements:- (a) MCCB 40 Amp 16 KA 4 pole - 01 No (b) MCCB 32 Amp 16 KA 3 pole - 02 Nos (c) Star delta starter 10 HP - 02 Nos (d) MCB SPN 6 - 32 Amp, 10 KA - 02 Nos (e) Aluminium bus bar 100 Amp TPN - 01 set (f) Multifinction meter VAF & PF - 01 No (g) Indicating lamps - 01 (set of three)
Foot Valve with gunmetal working parts conforming to IS 4038, 80 mm dia complete all as specified and directed.
EXTERNAL ELECTRIFICATION:-Supply, install, testing & commissioning of 11 KV, 630A, 20 KA, Motor operated, Compact, outdoor, both side extensible, non drawout type, +V+ (01 No. fixed type motor operated Vaccum Circuit Breaker (VL) outgoing Safeplus compact gas insulated Ring main unit, including extension of existing HT panel, all live parts enclosed in a robotically welded stainless steel tank of IP 67 class of protection including coupling accessories complete all as specified and as directed. Make: ABB Ltd or equivalent of other make specified in the list of manufacturer.
11KV, 630A, 20KA, Motor operated, Compact, outdoor, both side Extensible, Non drawout type, +C+ (1No. Load Break Switch (OD) incomer ) outgoing) SAFEPLUS compact gas insulated Ring Main Unit, All live parts enclosed in a robotically welded stainless steel tank of IP 67 class of protection. With Battery and Battery Charger complete all as specified and as directed. Make: ABB Ltd or equivalent of other make specified in the list of manufacturer.
Supply, install, testing and commissioning distribution transformer of capacity 200 KVA step down, outdoor type (plinth mounted) complete with standard fittings, HT 11 KV 3 phase, LT 433 volts, 3 phase 4 wire with off load tappings on HT side to vary secondary voltage including comprising of following (a) No load voltage ratio 11 KV/433V (b) Vector Group DYN 11 (c) Type core type double copper wound (d) temperature rise 45/50 degree centigrade (oil/winding) (e) tap changer on HT side with + 7.5% in steps of 2.5% each (f) cable end box on HT and LT side to accommodate cables (g) conservator with drain valve (h) explosion vent with diaphram and sighting glass (j) air release plug (k) earthing terminals 02 Nos for body and 02 Nos for neutral (l) lifting lugs (m) flanged rollers (n) silica gel breather with transparent body and oil seal (o) radiator with top and bottom shut off brass gate valves (p) brass/ gun metal drain valve (q) first filling of transformer oil (r) cooling ONAN (s) inspection cover (t) danger notice board (u) cable entry box complete with all necessary control cables, necessary civil works for making foundation for transformer mounting etc complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium stranded conductor, 11000 volts grade (earthed), cross sectional area 3 core 95 sqmm complete all as specified and as directed.
Rubber mat of size 1 mtr x 2 mtr x 2.5 mm suitable for HT 11 KV complete all as specified and as directed.
Supply and lay LT UG cable XLPE insulated galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volt grade with aluminium conductor cable of size 3.5 core 400 sqmm and making cable connection with cable glands, lugs, nut, bolts, washers etc complete all as specified and as directed.
All as per item No.84 above but for 3.5 core 95 sqmm
All as per item No.84 above but for 3.5 core 50 sqmm
All as per item No.84 above but for 4 core 25 sqmm
All as per item No.84 above but for 4 core 16 sqmm
All as per item No.84 above but for 2 core 6 sqmm
Supply & install feeder pillar box out door type made out of MS sheet 3 mm thick welded on angle iron frame 40 x 40 x 6 mm duly grouted in earth incl PCC 1:3:6 type C-1 with locking arrangement and painting with following accessories suitable for incoming/out going arrangments:- (a) MCCB 400 Amp 36 kA 4 pole - 01 No (b) MCCB 100 Amp 25 KA 4 pole - 02 Nos (APFC + DG set) (c) MCCB 200 Amp 25 KA 4 pole - 02 Nos (Bldg 1 & 2) (d) Aluminium bus bar 600 Amp TPN - 01 set (e) Multi function digital meter (VAF & PF) - 01 No (f) Indicating lamp - 01 No (Set of three)
Supply and install outdoor type Automatic Power Factor Correction (APFC) Panel of 50 KVAr with 8 steps(1x1+2x2+1x5+4x10) super heavy duty box type capacitor 415 V, 50 Hz with 4 pole MCCB 100 Amps,25KA as incomer auto & manual operation, micro processor based power factor controller, suitable capacitor duty contactors with switch gear control for each capacitor, indicating lights for step ON, Aluminium busbar, powder coated cubical panel made out of 2mm thick CRCA sheet duly hinged type doors and mechanical locking arragement, front and rear opening, cable entry/exit holes at bottom including all necessary accessories and control wiring. The panel should be mounted on angle iron frame of size 40x40x6mm with base channel duly grouted in PCC foundation and platform with PCC 1:3:6 type C-1 complete all as specified and directed. Note : Incomer MCCB shall be paid separately
Steel tubular swaged poles type 410 SP-31 (9 mtr long) complete with CI base plate, finial taper plug, bolts, nuts & screws complete all as specified and as directed.Note:- Excavation,RFR and concreting shall be measured and paid seperately.
LED street light 70 watt made up of pressure die-cast aluminium housing with high power LED as lighting source and lence embedded PC cover having top opening separate driver compartment with IP-66 protection and impact resistance of IK07 with 10 KV built-in surge protection device including GI bracket made out of GI pipe light grade 40mm dia of 1.2 mtr length with suitable clamp made out of MS flat (02 Nos) including nuts, bolts & washers complete all as specified and as directed.
Thermoplastic polycarbonate cable junction boxes of size 200x160x98mm with metric knock outs for cable entry with IP 65 protection with terminals and suitable clamps for fixing complete all as specified and as directed. Make : Hensel or equivalent of other make specified in the list of manufacturer.
Flexible 3 core 1.5 sqmm copper conductor for connecting from junction box to street light fitting complete all as specified and as directed.
Riddled soil as earth cushioning to UG cable by using IS sieve to separate the composite particle/roots etc and refilling/spread in trenches as cushioning and rammed down to form a solid bed all as specified and as directed. Note :- Punned thickness shall be measured and paid seperately.
SEWAGE DISPOSAL:- DWCP pipes 180 mm outer dia laid and jointed complete all as specified and as directed.
AVIATION OBSTRUCTION LIGHT:- Aviation obstruction light LED type comprising aluminium housing with polycarbonate enclosure including necessary fixing arrangements and all necessary accessories.(Make Bajaj Cat No.BGAV 302 LED or equivalent of other make specified in the list of manufacturer) complete all as specified and as directed.
Sheet metal enclosure for MCB DB SPN 2 way,single door,240 volts without bus bar complete all as specified and as directed.
MCB SPN 6 Amps complete all as specified and directed.
Road/Path/Culvert/Hardstanding-WMM 150 mm thick (in two layers of 75 mm each ) (compacted thickness) , watered,spread, rolled and consolidated to gradient and camber to form a true surface complete all as specified and as directed .
75mm thick WMM watered, rolled and consolidated to required gradient and camber to form a true surface complete all as specified and as directed .
600x600x40mm machine cut granite stone tile ,rough finished in natural black grey in colour, laid over sand/grit cushioning and joint to be laid with Mexican grass pattern strip of 75-100 mm wide complete all as specified and as directed .Note:- Grass strip to be paid and measured seperately.)
Mexican grass in approved earth 50 to 60 mm thickness including providing manure, in joints of granite slab complete all as specified and as directed .
FIRE FIGHTING:-Automatic gunmetal air release valve 50 mm dia complete all as specified and as directed.
Factory made and CPRI tested indoor type wall mounted on wall brackets.Lt panel board cubicle type panel board suitable for 415 volts,3 phase,4 wire ,50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 100 Amps for phases & neutral mounted on porcelain insulators.The panel shall be weather proof,dust and vermin proof IP-54 class protection and fabricated out of 2 mm CRCA sheet duly powder coated after seven tank process.The panel shall be front openable type adequate space all around accessories such as LT switch gear and metering instruments including internal wiring in the panel with FRLS non flammable insulated multistranded/solid copper conductor cable 2.5 Sqmm,1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard IS practices and comprising of following accessories. (I) Incomings. (a)MCCB 415 Volts,40 Amp rating,4 pole microprocessor based 16 KA-1 Nos (b)Digital volt meter-0-500 Volts-01 (c)Digital multi-function meter (Volts,Amp,Hz,PF) with and including resin cast CTs-01 Set (d)Phase indicating lamp(set of 3)
FRLS armoured cable copper conductor 2 x 1.5 Sqmm with ISI marked Make : Havells/V Guard
Wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours ( Make CG or equivalent to Bajaj/havells.
Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display,having Controls for Reset, Mute, Accept , Silence alarms and Self Test, with programmable free keys and duly approved by EN54/LPCB/VDS/FM Make: SIEMENS/ NOTIFIER/ BOSCH
ARBORICULTURE:-Supply only approved earth for planting of grass (Approved earth shall be obtained from out side MD land)
Supply only river sand complete all as specified and as directed .
Labour only for mixing spreading levelling watering and well ramming approved earth and sand in required proportion as directed for planting of grass in layers not exceeding 25cm thick including supply and mixing of 1/2 Kg/Sq of cow dung 0.25 Kg /Sqm of bone meal and 15 grams /Sqm of insecticides complete all as specified and as directed .
Excavation pits of size 30×30×30 cm size in loose soil and dilling the pit with mixture of approval earth and river sand in the proportion of 1:3 by volume mixed with 2Kg of cowdung power , 100 gms bone meal and 10 gms of insecticide (Furadan)and removal of excavation soil to a distance n.exc 50m complete all as specified and as directed .
Supply and planting redpalm sapling having 45cm height complete all as specified and as directed .
Supply and planting flower plants sapling having 10cm minimum height complete all as specified and as directed .
Supply and planting colour flower plants sapling having 15 to 30cm height complete all as specified and as directed .
Supply and planting song of India flower plants sapling having 15 to 30cm height complete all as specified and as directed .
Supply and planting Dracena flower plants sapling having 15 to 30cm height complete all as specified and as directed .
MISCELLANEOUS ITEMS: Rigid nonmetallic medium grade PVC conduit 25mm dia ISI marked (on surface) with and including conduit accessories and all fittings such as tees, bends, elbows,reducers,bell mouth tube ends and fixing accessories such as couplers,lock nuts,saddles,pipe hooks etc.complete all as specified and as directed.-
1/2 module flush metal GI box, modular type complete all as specified and as directed.
Modular TV socket of make legrand for 1 module with cover plate cat part no 675546 or eqvt in Bajaj , Crompton complete all as specified and as directed.
HOT WATER SUPPLY: Electric water heater storage type, capacity 25 litres, BEE 5 star rated, PVC type with stainless steel inner tank including hot and cold outlet/inlet bronze/pvc pipes complete all as specified and as directed.Make.V Guard sprinhot plus 25L with (FCP) or equivalent of other make specified in the list of manufacturer.
4 pole MCCB 12-40 Amp,50 Hz,415 volt breaking capacity 25 KA including suitable enclosure made up of CRCA sheet 2mm thick complete all as specified and as directed.
COMPREHENSIVE MAINTENANCE OF LIFT:- Comprehensive maintenance of Lifts (2 Nos) including checking its smooth functioning and greasing to all movable parts such as motor shaft,deflector shieve shaft,governor pulley and wire ropes etc and lubricate sleeve bearing of governor pulley once in fortnight,clean all contacts by CRC,lubricate gears and top up oil in gear box,check adjust clearance between break shoes and drum,check the condition of hoist ropes and governor ropes,lubricate guides and guid shoes in the hoist way,check operation of car and lock from the top at each landing,check closer safety,clean and adjust if necessary,check the landing doors can be opened by emergency keys monthly and replacing the worn out Electrical and mechanical parts whenever necessary complete all as directed by Engineer-in-Charge for electrically operated gearless passenger 884 Kg capacity lift (02 Nos Passenger lift of 13 Passenger) through OEM to serve ground plus five upper floors all as mentioned in all as mentioned in BOQ item No.124 complete all as specified and as directed for First year after expiry of defects liability period.
All as per item no.126 here in before but for Second year after expiry of defects liability period.
All as per item no.126 here in before but for Third year after expiry of defects liability period.
Dismantling:-Taking down KWh meter deposit to MES store yard complete all as specified and as directed.
Taking down DBs any type with all accessories complete all as specified and as directed.
Standby DG supply:-Silent type diesel engine driven generating set of capacity 40 KVA/ 32 KW, 415 volts, 3 phase 4 wire, 1500 RPM directly coupled with diesel engine capable of taking 10% overload for one hour for every 12 hours (as per BS-5514/649) with flexible coupling mounted on common base plate on vibration pads on foundation as recommended by manufacturer including AMF panel alongwith connected accessories with relay panel for automatic starting on main electric supply failure, control panel having meters, AVR control excitation. The DG set shall comprise of electric starter motor, turbo charger, water cooled and comprising all standard fittings/fixtures and all piping etc as below:- Engine :- Diesel engine CRDI four stroke, four cylinder, water cooled diesel engine to develop 43 BHP @ 1500 RPM complete with engine safety and all standard accessories as per the standard of BS- 5514, ISO-3046. complete all as specified and as directed.
Alternator :- Direct coupled with diesel engine having KVA rating 40 KVA and KW rating 32 KW at 0.8 power factor, 415 volts, 50 Hz, 1500 RPM, 3 phase 4 wire system, class `H' insulation, IP-23 protection enclosure as per the standard of IS-4722, BS-5000. Acoustic Enclosure :- Acoustic enclosure shall be powder coated and fabricated as per CPCB-II norms as amended upto date, sound level 75 dB (A) at 1 mtr from enclosure in free field conditions as per ISO 8528 AMF Panel :- The micro processor based AMF panel shall be with AMF controller suitable to start the engine on main failure after 10-15 second time delay and to switch off engine only after 60-90 seconds after the main supply restored. The AMF controller shall have under/ over voltage, over load protection, coolant temp cut off, fuel control upto 10% tank capacity. The panel shall also have one change over switch and switch gears of suitable capacity to bypass main supply when the AMF control become defective.
Note : The following are included in the scope of work :- (a) The panel will be complete with internal wiring with suitable size of multi stranded copper cable. The suitable control of AMF panel with all meters, control wires. (b) Tools as supplied by the manufacturer (c) Fuel tank shall be provided inside canopy (d) thermostat switch inside the acoustic enclosure shall be provided to shut off the DG set incase of temperature increases beyond its rated temperature inside the acoustic enclosure (e) there shall be proper air circulation and windows with glass in the acoustic enclosure suitably located to read the meters of various controls from outside (f) Necessary grouting including mild steel work and anti vibration pad shall be provided (g) necessary foundation of installation and plinth protection of the DG set shall be provided as per manufactuers recommendation (h) necessary 10% overload test shall be carried out in the presence of testing officer nominated by Accepting Officer. (j) Shifting of DG set from showroom/factory to the site by means of truck/crane is the responsibility of the contractor.
Feeder pillar box out door type made out of MS sheet 3 mm thick welded on angle iron frame 40 x 40 x 6 mm duly grouted in earth incl PCC 1:3:6 type C1 with locking arrangement and painting with following accessories suitable for incoming/outgoing arrangements :- (a) 4 pole MCCB 100 Amp, 50 Hz, 415 volt 25 KA - 01 No (b) 4 pole MCCB 63 Amp, 50 Hz, 415 volt 16 KA - 03 Nos (Bldgs + Spare) (c) 4 pole MCCB 12 to 40 Amp, 50 Hz, 415 volt 16 KA - 02 Nos (Pump House & Street light) (d) Aluminium bus bar 200 Amp TPN - 01 set (e) Multi function digital meter (VAF & PF) - 01 No (f) Indicating lamp - 01 set of three
Feeder pillar box out door type made out of MS sheet 3 mm thick welded on angle iron frame 40 x 40 x 6 mm duly grouted in earth incl PCC 1:3:6 type C1 with locking arrangement and painting with following accessories suitable for incoming/outgoing arrangements :- (a) 4 pole MCCB 63 Amp, 50 Hz, 415 volt 25 KA - 01 No (b) 4 pole MCCB 12 to 40 Amp, 50 Hz, 415 volt 16 KA - 03 Nos (Lift, FF + Spare) (c) MCB SPN 6 - 32 Amp C curve 10 kA - 03 Nos (Aviation & Common area lights) (c) Aluminium bus bar 100 Amp TPN - 01 set (d) Multi function digital meter (VAF & PF) - 01 No (e) Indicating lamp - 01 set of three
VARAHA INFRA LIMITED
JAIN BUILDER
A2Z ENGINEERS AND PILE FOUNDATIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid