Loading…
Loading…
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
19 Aug 2026, 6:00 pm
GE (AF) Bidar
Garrison Engineer (Air Force) Bidar, Military Engineer Services, Air Force Station Bidar, Bidar-585401
MAINT AND REPAIRS TO INTERNAL ELECTRIFICATION, LED LIGHTING AND FIXTURES AND CONNECTED WORKS FOR CIVILIAN MARRIED ACCN AND REMOTE OTM BLDGS UNDER GE AFS BIDAR
2026_MES_781455_1
CA NO. GE(AF)/BID/TOKEN/08 OF 2026-2027 8233/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Bidar
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Bidar
₹36,000
Yes
29 Jul 2026
29 Jul 2026
26 Aug 2026
29 Jul 2026
19 Aug 2026
12 Aug 2026
29 Jul 2026 - 11 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0 | SCHEDULE OF WORKS | - | - | - | - |
| 1 | Taking down unserviceable / burnt point wiring of any description / type / size from existing conduit / casing capping, excluding switches, sockets, regulators, etc., complete all as specified and as directed by Engineer-in-Charge. | 405 | Point | 100 | ₹40,500 |
| 2 | Material and labour for Point wiring for one light point/fan point/ bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through existing PVC conduit 20mm dia (medium duty, ISI marked) including provision of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc.complete all as specified and as directed.
Note :
Switches/ socket / regulator shall be measured and paid separately under appropriate item of BOQ). | 75 | Point | - | - |
| 3 | All as per Serial item No 2 here-in-before, but for one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator | 35 | Point | - | - |
| 4 | All as per Serial item No 2 here-in-before, but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. | 30 | Point | - | - |
| 5 | All as per Serial item No 2 here-in-before, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board | 60 | Point | - | - |
| 6 | All as per Serial item No 2 here-in-before, but for one bell point controlled by one, bell switch 5 Amps | 10 | Point | - | - |
| 7 | All as per Serial item No 2 here-in-before, but for one light point controlled by one, two way switch 5 Amps | 8 | Point | - | - |
| 8 | All as per Serial item No 2 here-in-before, but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant Low smoke (FRLSH) PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point incl running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. | 50 | Point | - | - |
| 9 | Material and labour for Point Wiring with 1.5 sq mm Copper Conductor single core PVC insulated Flame Retardant Low Smoke (FRLSH) Unsheathed 1100 Volt grade multi-stranded Cable drawn through existing PVC Casing and Caping including PVC insulated and unsheathed Single Core multi-stranded Copper Conductor Cable of size 1.5 sq mm (FRLSH) Green in Colour as Earth Continuity Conductor connected to Common Earth and Earth dolly for One Light Point controlled by One 1-Way Switch 5 Amp, complete all as specified and as directed by Engineer-in-Charge. | 30 | Point | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
Tender8233.pdf
Tender Documents • 0.81 MB
BOQ_875424.xls
BOQ • 2.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].