Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹25.0 L+₹2.6 L (11.4%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹25.1 L+₹2.7 L (12.0%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹25.4 L+₹3.0 L (13.4%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | Rejected-Technical | - | Rejected-Technical Not recommended being documents not submitted. |
Tender Value
₹23.8 L
EMD Value
₹47,500
Closing Date
29 Mar 2021, 6:00 pmClosed
MAJ JP SAHOO
GE 872 EWS, C/O 99 APO
SPECIAL REPAIRS OF IRON REMOVAL PLANTS AND SPECIAL REPAIRS TO LT PANEL AT ALONG MIL STN UNDER GE 872 EWS
2021_MES_427772_1
8857/T-57/E8
Open Tender
Miscellaneous Works
Item Rate
183 days
ALONG
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 872 EWS
₹47,500
Yes
31 May 2021
4 Mar 2021
30 Mar 2021
4 Mar 2021
29 Mar 2021
17 Mar 2021
4 Mar 2021 - 9 Mar 2021
Amount
SPECIAL REPAIRS TO IRON REMOVAL PLANTS
Taking up or down Steel Water Tubing 15mm/20mm bore (dia) with Fittings/ Connections of any description, complete as all specified and as directed.
Taking up or down Steel Water Tubing/ PPR Pipes 80mm bore (dia) with Fittings/ Connections of any description, complete as all specified and as directed.
M&L Dismantling Joints of Flanged Pipe 80mm bore (dia) in Position and Removing Old Rubber or Fiber Gasket, Bolts and Nuts, etc., complete all as specified and as directed.
M&L Galvanised Steel Water Tubing 20mm bore (dia), ‘medium grade’ with all Fittings as required at Site, laid in Trenches or fixed on Walls, Ceiling or laid in Floors or any Other Situations, complete as all specified and as directed.
M&L Galvanised Steel Water Tubing 80mm bore (dia), ‘medium grade’ with all Fittings as required at Site, laid in Trenches or in any Situations, complete as all specified and as directed.
Supply & Laying PP-R (Polypropylene Random Copolymer) 3 layer Pipe SDR 7.4 (PN 16) and Fittings 90mm bore (dia) having Inner with Anti-microbial Property and Outer Green Coloured, UV Stabilize Property Fusion welded having Thermal Stability for Hot and Cold Water Supply including PP-R Plain and Brass threaded Poypropylene Random Fittings and required for fixing to Walls or laid in Floor/ Ground and Testing of Joints as per Manufactures instruction, complete all as specified and as directed.
S&F Gun Metal Globe/Gate Valve 20mm bore (dia) with Iron Wheel Head, ISI marked, screwed both Ends for Iron Pipe including Taking down/out unserviceable Globe/Gate Valve, complete all as specified and as directed.
M&L Cast Iron Butter-fly Valve 80mm bore (dia), Wafer type, Flanged and drilled both Ends, ISI marked, conforming to IS:13095 with all Jointing Materials such as suitable size Mild Steel Nuts, Bolts, GI Washers, Rubber Gasket, etc. and Testing against Leakage including Taking out/ down Unserviceable Butter-fly Valve, complete all as specified and as directed.
M&L Taking out (Unloading) All Old Catalyst from Oxidation Chamber of IRP having capacity 5500 GPH of MAKE : RMCO with Proper Care, Cleaning complete Pipes, Butter-fly Valves, etc. of any Capacity, Flow and Height by Opening the Manhole Cover disconnection and including Removing the Waste Materials up to a distance not exc. 100 Metre away from the Site of Work, Spreading and Levelling, complete all as specified and as directed.
M&L Taking out (Unloading) All Old Rusted and Muddy Filter Media like Sand, Gravels, etc. from Iron Removal Filter Vessel with Proper Care, Cleaning complete Pipes, Butter-fly Valves, etc. of any Capacity, Flow and Height by Opening the Manhole Cover disconnection and including Removing the Waste Materials up to a distance not exc. 100 Metre away from the Site of Work, Spreading and Levelling, complete all as specified and as directed.
M&L Preparing Inner Surfaces of Iron Removal Filter Vessal (Empty i.e. after Taking out of Old Catalyst, Muddy Filter Media like Sand, Gravels, etc.) of any Capacity, Flow and Hight by through Scrapping Old Paints, Removing Rust, etc. with Emery Papers/ Eco Friendly Chemicals, Through Cleaning Complete and applying Two Coats of Anti-corrosive Black Bituminous Paints (suitable for Drinking Water Purpose) as per Standard Engineering Practice, complete all as specified and as directed.
M&L Preparing Inner Surfaces of Oxidation Chamber (Empty i.e. after Taking out of Old Catalyst, Muddy Filter Media like Sand, Gravels, etc.) of any Capacity, Flow and Hight by through Scrapping Old Paints, Removing Rust, etc. with Emery Papers/ Eco Friendly Chemicals, Through Cleaning Complete and applying Two Coats of Anti-corrosive Black Bituminous Paints (suitable for Drinking Water Purpose) as per Standard Engineering Practice, complete all as specified and as directed.
Supply & Filling in layers New Life Manganese Dioxide (MnO₂) Compond (as approved) to Remove Iron and Manganese from Drinking Water by process of Oxidation and suitable for Use in Filteration Plant and Oxidation Chamber (as per requirements), complete all as specified and as directed.
Supply & Filling in layers New Washed, Cleaned, Dust Free Filter Media (Sand & Gravels as approved) of Sizes 3/4"x1/2", 1/2"x1/4", 1/4"x1/8", 1/8" x1/6" suitable for Use in Filteration Plant (as per requirements), complete all as specified and as directed.
S&F PVC Strainer, Double Nut type (as approved) as per Site requirements including Taking down/ up Unserviceable Strainer of any description, complete as all specified and as directed.
M&L Mild Steel Bolts, Nuts and all Gaskets (as approved) as per Site requirements including Taking down/ up Unserviceable Bolts, Nuts, Gaskets, etc. of any description, complete as all specified and as directed.
S&F Pressure Gauge with Fittings (as approved) as per Site requirements including Taking down/ up Unserviceable Pressure Gauge of any description, complete as all specified and as directed.
Supply, Installation, Commissioning & Testing Chemical Dozing (Metering) Pump, Reciprocating type for Injecting Calcium Hypochloride employing having Output 2 U.S. GPD to 4 U.S. GPD and adjustable high pressure upto 100 PSI, 230 Volt, 50 Hz including Taking down Unserviceable Chemical Dozing (Metering) Pump of any description, complete as all specified and as directed. MAKE : DECRIN/ RAMCO or as approved by GE
Supply, Installation, Commissioning & Testing Electrically operated Chlorine Dosing Tank 100 LITRE Capacity, made out of PE/ FRP MOC with PE/ FPR Lid and Level Gauge along with Single Phase Electric Motor and Agitator with Shaft and Blade in plastic mounted on Tank, Lid must have Port hole for pouring Clacium Hypochloride and Water when necessary. Lid must have Provision for mounting Dosing Pump on the Lid/ Wall including Dismantling/Taking down unserviceable FRP Container and Connected Items, Complete all as specified and as directed. MAKE : RAMCO or equivalent Make as approved by GE.
M&L Disconnecting of defective Air Compressor including Electric Connection and Removing to AGE E/M Yard at ALONG, Dismantling defective Air Compressor as per direction and in front of JE/Engineer-in-Charge, Repairing and Replacing unserviceable following Spare Parts including Cleaning Serviceable Spare Parts, Greasing, etc. and Re-assembling, Re-installation and Providing All Connections and Testing, complete all as specified and as directed:- (a) Air Pressure Gauge (b) Ball Bearing for Electric Motor (c) Comressor Oil (d) Gun Metal Butter-fly Valve 15mm bore (dia) (e) V - Belt NOTE : Cost of Spare Parts mentioned at Sl No. (a) to (e) here-in-above will deemed to be included in the Quoted Unit Rate.
SPECIAL REPAIRS TO LT PANELS & CONNECTED ITEMS
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for of Laying of Cable Line, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Cable Line, etc. with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed.
M&L Making Horizontal Boring under Road, Pavement, Hardstanding including Cutting, etc. with Manual Anger or Bookie, etc. for inserting Pipe upto 100mm bore (dia), complete all as specified and as directed. NOTE : Pipes will be Measured and Paid separately under relevent Items.
Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc. incuding Taking out Bricks/ Concrete Cable Cover, GI Pipes, etc., complete all as specified and as directed. NOTE : Necessary Earth Work will be Measured and Paid under appropriate Items.
Supply & Laying or Fixing or Passing through Pipe, 1100 Volt grade Heavy duty XLPE Cable with PVC insulated Aluminium Stranded Conductor served with an Inner sheathing of PVC Tape Armoured with Galvanised Steel Wire or Tape and Overall PVC sheathed 16 Sqmm, 4 Core Nominal Cross Section and Testing, complete all as specified and as directed. NOTE : Earth Works, Pipes, Concrete Cable Cover, etc. will be Measured and Paid separately under relevent Items.
Supply & Laying or Fixing or Passing through Pipe, 1100 Volt grade Heavy duty XLPE Cable with PVC insulated Aluminium Stranded Conductor served with an Inner sheathing of PVC Tape Armoured with Galvanised Steel Wire or Tape and Overall PVC sheathed 50 Sqmm, 3½ Core Nominal Cross Section and Testing, complete all as specified and as directed. NOTE : Earth Works, Pipes, Concrete Cable Cover, etc. will be Measured and Paid separately under relevent Items.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
Supply & Laying Un-reinforced Pre-cast Concrete Cable Cover Class LV, Type 1 with Concrete grade M-20 (minimum), size 250x150x40mm, complete all as specified and as directed.
M&L Galvanised Steel Tubing Pipe 50mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc. (if ordered/ as per Site requirement), complete all as specified and as directed.
Supply, Installation, Testing & Commissioning Factory Made (CPRI approved Manu-facturer) LT Feeder Pillar Box, made out of 3.15mm thick CRCA Sheet, Outdoor type, Dust Proof and Vermin Proof (IP-54) and Painted with Two Coats of Synethetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer, suitable for 415 Volts, 3 Phase, 4-Wire system, 50 Hz supply having Aluminium Bus-bars 300 Amp for Phase and Neutral, installed on Porcelain/ Epoxy Insulator, Platform mounted of size 600x500x450mm, Self moulded type and Angle Iron Frame 50x50x6.0mm, Front and Rear Opeing with Double Shutter and Locking Arrangement with 50mm Lock, MAKE : HARISON/ NAVTAL and grouting Legs in Cement Concrete 1:2:4 (20mm graded stone aggregate) Block of size 300x300x450mm including necessary Formworks, Earth Works, etc., Providng all Electric Connections and Testing including Taking down/out Old Unserviceable Feeder Pillar Box/ Panel, complete all as specified and as directed and Comprising with including to accumodating the followings:- INCOMING:- (a) MCCB 125 Amp 4 Pole, 36 kA, 430 Volt - 01 No. (b) Digital Amp Meter 0-200 Amp, Square Flush pattern - 01 No. (c) Digital Volt Meter 0-500 Volt, Square Flush pattern - 01 No. (d) Indicating Lamp LED type in Incomming Phase - 01 Set (e) Internal Wiring with PVC insulated Copper Conductor Multi-stranded Cable 1100 Volt grade IS-694 marked of appropriate gauge including Copper Lugs (f) Connection from MCCB to Bus-bars with Solid Aluminium Conductor (g) MCCB shall be provided with suitable Spreader of Aluminium Conductor for fixing of Incomming Cable OUTGOING:- For 05 No. Outgoing Cables
Supply, Installation, Testing & Commissioning Factory Made (CPRI approved Manu-facturer) LT Feeder Pillar Box, made out of 3.15mm thick CRCA Sheet, Outdoor type, Dust Proof and Vermin Proof (IP-54) and Painted with Two Coats of Synethetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer, suitable for 415 Volts, 3 Phase, 4-Wire system, 50 Hz supply having Aluminium Bus-bars 600 Amp for Phase and Neutral, installed on Porcelain/ Epoxy Insulator, Platform mounted of size 1200x1000x450mm, Self moulded type and Angle Iron Frame 50x50x6.0mm, Front and Rear Opeing with Double Shutter and Locking Arrangement with 50mm Lock, MAKE : HARISON/ NAVTAL and grouting Legs in Cement Concrete 1:2:4 (20mm graded stone aggregate) Block of size 300x300x450mm including necessary Formworks, Earthworks, etc., Providng all Electric Connections and Testing including Taking down/out Old Unserviceable Feeder Pillar Box/ Panel, complete all as specified and as directed and Comprising with including to accumodating the followings:- INCOMING:- (a) MCCB 160 Amp 4 Pole, 25 kA, 430 Volt - 01 No. (b) Digital Amp Meter 0-400 Amp, Square Flush pattern - 01 No. (c) Digital Volt Meter 0-500 Volt, Square Flush pattern - 01 No. (d) Indicating Lamp LED type in Incomming Phase - 01 Set (e) Internal Wiring with PVC insulated Copper Conductor Multi-stranded Cable 1100 Volt grade IS-694 marked of appropriate gauge including Copper Lugs (f) Connection from MCCB to Bus-bars with Solid Aluminium Conductor (g) MCCB shall be provided with suitable Spreader of Aluminium Conductor for fixing of Incomming Cable OUTGOING:- For 05 No. Outgoing Cables
Supply, Installation, Testing & Commissioning Factory Made (CPRI approved Manu-facturer) LT Feeder Pillar Box, made out of 3.15mm thick CRCA Sheet, Outdoor type, Dust Proof and Vermin Proof (IP-54) and Painted with Two Coats of Synethetic Enamel Paint over a Coat of Red Oxide Zinc Chrome Primer, suitable for 415 Volts, 3 Phase, 4-Wire system, 50 Hz supply having Aluminium Bus-bars 600 Amp for Phase and Neutral, installed on Porcelain/ Epoxy Insulator, Platform mounted of size 1200x1000x450mm, Self moulded type and Angle Iron Frame 50x50x6.0mm, Front and Rear Opeing with Double Shutter and Locking Arrangement with 50mm Lock, MAKE : HARISON/ NAVTAL and grouting Legs in Cement Concrete 1:2:4 (20mm graded stone aggregate) Block of size 300x300x450mm including necessary Formworks, Earthworks, etc., Providng all Electric Connections and Testing including Taking down/out Old Unserviceable Feeder Pillar Box/ Panel, complete all as specified and as directed and Comprising with including to accumodating the followings:- INCOMING:- (a) MCCB 200 Amp 4 Pole, 36 kA, 430 Volt, Adjustable type - 01 No. OUTGOING:- (a) MCCB 125 Amp 4 Pole, 25 kA, 430 Volt, Adjustable type - 02 No. (b) MCCB 63 Amp 4 Pole, 25 kA, 430 Volt, Adjustable type - 01 No. (c) Digital Amp Meter 0-400 Amp, Square Flush pattern - 01 No. (d) Digital Volt Meter 0-500 Volt, Square Flush pattern - 01 No. (e) Indicating Lamp LED type in Incomming Phase - 01 Set (f) Internal Wiring with PVC insulated Copper Conductor Multi-stranded Cable 1100 Volt grade IS-694 marked of appropriate gauge including Copper Lugs (g) Connection from MCCB to Bus-bars with Solid Aluminium Conductor
M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.3mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down Old/ Unserviceable Earthing of any description, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
M/S S. P. ENTERPRISE
STANDARD ELECTRIC WINDERS
M/s HALDER ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .