Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-Finance HIMACHAL PRADESH HP | HAMIRPUR | HIMACHAL PRADESH | 174304 | ₹5.2 L | L1 | Accepted-Finance Due to Lowest Rate |
| 2 | L2₹6.0 L+₹78,275 (15.1%)Rejected-Finance | ₹6.0 L+₹78,275 (15.1%) | L2 | Rejected-Finance Due to Highest Rate |
| 3 | L3₹7.6 L+₹2.4 L (46.2%)Rejected-Finance | ₹7.6 L+₹2.4 L (46.2%) | L3 | Rejected-Finance Due to Highest Rate |
| 4 | L4₹10.8 L+₹5.6 L (108.5%)Rejected-Finance | ₹10.8 L+₹5.6 L (108.5%) | L4 | Rejected-Finance Due to Highest Rate |
| 5 | L5₹11.5 L+₹6.4 L (123.4%)Rejected-Finance VILLAGE GAWALTH P O KUINAL TEHSIL KOTKHAI DISTT SHIMLA H P | KOTKHAI | SHIMLA | HIMACHAL PRADESH | ₹11.5 L+₹6.4 L (123.4%) | L5 | Rejected-Finance Due to Highest Rate |
| Sl No | Description | Qty | Unit | Kulwant Kumar L4 | Ajeev Kumar L2 | Vivek Dogra L3 | Vinod L5 | VIJAY KUMAR L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in foundations,trenches etc in earth work in all kind of soil, such as pick work, jumper work, blasting hard or soft rock by chiselling where the blasting work is prohibited slushy daldal and saturated soil including pumping or bailing out water with in all heights, stacking the excavated soil within all leads clear from the edge of excavation and then returning the stacked soil in 15cm (fifteen centimetres) layers, when required into plinths, of foundations etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth, as per the direction of Engineer-in-Charge with in all leads and lifts. | 405 | Cum | 870 ₹3,52,350 | 50 ₹20,250 Lowest | 244 ₹98,820 | 920 ₹3,72,600 | 195 ₹78,975 |
| 2.00Laying, jointing & testing of GMS (plan ended pipe) with circumfrential 90% butt welded joints & 10% for flange joint with MS flanges of following dia by electrical arc welding with minimum two layers capable to withstand required test pressure (minimum welding thickness shall be equal to pipe wall thickness) including manufacturing and fabrication of reducers/ tapers, all short pieces, bends of required degree as per site requirement made from parent tubes. The laying of pipe shall also include intermediate flanged joints spaced at an interval of 15 pipe lengths or where ever required as per direction of the Engineer-in-charge dully welded in three layers (two for outer & one on inner side) and all other operation such as cutting, cleaning, welding, jointing, fabrication of bends, tees etc, lowering and laying in excavated trench to ensure required level i/c flushing, cleaning, and hydraulic testing complete in all respect & to the entire satisfaction of the Engineer-in-Charge (Earth work in trenches and the cost of providing flanges i/c nut & bolts, gasket, will be measured and paid for separately). The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The welding electrodes shall be as per IS 814 of Advani Oerlikon/L&T or ISI marked make. The damaged portion of the pipes and all the specials (if damaged during laying & jointing operation of pipe) made from the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The rates also includes entire carriage of material, flushing, cleaning of butt welded joints complete in all respect and to the best satisfaction & direction of Engineer in charge with in all leads and lifts. | ||||||||
| 2.01 | 80mm Dia (M) (Table-17) | 3,600 | Rmts. | 165 ₹5,94,000 | 135 ₹4,86,000 | 168 ₹6,04,800 | 180 ₹6,48,000 | 95 ₹3,42,000 Lowest |
| 3.00 | Providing and Fixing of double flanged Cast Steel Non Return Valve (NRV) of 80mm dia of Leader/Kirloskar make (with hand wheel) API-600, Cl-150 as per IS Code-5312 latest upto date ammendments standard make with bols, nuts, rubber insertion etc. complete in all respect as per the direction and to the entire satisfication of Engineer-in-Charge within all leads and lifts. | 2 | Nos. | 38,200 ₹76,400 | 29,000 ₹58,000 | 12,999 ₹25,998 Lowest | 38,900 ₹77,800 | 29,000 ₹58,000 |
| 4.00 | Providing and Fixing of double flanged Cast iron Sluice Valve of 80mm Dia various dia Leader/Kirloskar make (with hand wheel) Class PN-1.0 as per IS Code-14846 latest upto date ammendments standard make with bols, nuts, rubber insertion etc. (The tail pieces if required shall be measured & paid for separately) complete in all respect as per the direction and to the entire satisfication of Engineer-in-Charge within all leads and lifts. | 2 | Nos. | 27,500 ₹55,000 | 15,500 ₹31,000 | 12,999 ₹25,998 Lowest | 28,200 ₹56,400 | 19,000 ₹38,000 |
Tender Value
₹9.8 L
EMD Value
₹19,595
Closing Date
16 Apr 2026, 11:00 amClosed
Executive Engineer
Jal Shakti Division Kangra
Laying, Jointing and Testing of Rising Main 80mm dia (M) in Kholi under section Matour.
2026_HPIPH_133377_1
No. EE/JSDK/EA-I/Tender/2026- 29-78dt.-04.04.2026
Open Tender
Civil Works
Item Rate
90 days
Kangra
Please refer Tender documents.
6 documents required · 6 mandatory
₹350
₹19,595
19 Sept 2026
4 Apr 2026
16 Apr 2026
4 Apr 2026
16 Apr 2026
4 Apr 2026
4 Apr 2026 - 16 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Excavation in foundations,trenches etc in earth work in all kind of soil, such as pick work, jumper work, blasting hard or soft rock by chiselling where the blasting work is prohibited slushy daldal and saturated soil including pumping or bailing out water with in all heights, stacking the excavated soil within all leads clear from the edge of excavation and then returning the stacked soil in 15cm (fifteen centimetres) layers, when required into plinths, of foundations etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth, as per the direction of Engineer-in-Charge with in all leads and lifts. | |||||
| 2Laying, jointing & testing of GMS (plan ended pipe) with circumfrential 90% butt welded joints & 10% for flange joint with MS flanges of following dia by electrical arc welding with minimum two layers capable to withstand required test pressure (minimum welding thickness shall be equal to pipe wall thickness) including manufacturing and fabrication of reducers/ tapers, all short pieces, bends of required degree as per site requirement made from parent tubes. The laying of pipe shall also include intermediate flanged joints spaced at an interval of 15 pipe lengths or where ever required as per direction of the Engineer-in-charge dully welded in three layers (two for outer & one on inner side) and all other operation such as cutting, cleaning, welding, jointing, fabrication of bends, tees etc, lowering and laying in excavated trench to ensure required level i/c flushing, cleaning, and hydraulic testing complete in all respect & to the entire satisfaction of the Engineer-in-Charge (Earth work in trenches and the cost of providing flanges i/c nut & bolts, gasket, will be measured and paid for separately). The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The welding electrodes shall be as per IS 814 of Advani Oerlikon/L&T or ISI marked make. The damaged portion of the pipes and all the specials (if damaged during laying & jointing operation of pipe) made from the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The rates also includes entire carriage of material, flushing, cleaning of butt welded joints complete in all respect and to the best satisfaction & direction of Engineer in charge with in all leads and lifts. | |||||
| 2.01 | 80mm Dia (M) (Table-17) | - | Rmts. | - | - |
| 3Providing and Fixing of double flanged Cast Steel Non Return Valve (NRV) of 80mm dia of Leader/Kirloskar make (with hand wheel) API-600, Cl-150 as per IS Code-5312 latest upto date ammendments standard make with bols, nuts, rubber insertion etc. complete in all respect as per the direction and to the entire satisfication of Engineer-in-Charge within all leads and lifts. | |||||
| 4Providing and Fixing of double flanged Cast iron Sluice Valve of 80mm Dia various dia Leader/Kirloskar make (with hand wheel) Class PN-1.0 as per IS Code-14846 latest upto date ammendments standard make with bols, nuts, rubber insertion etc. (The tail pieces if required shall be measured & paid for separately) complete in all respect as per the direction and to the entire satisfication of Engineer-in-Charge within all leads and lifts. | |||||
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
termandcondition.pdf
Tender Documents • 0.18 MB
BOQ_197216.xls
BOQ • 0.23 MB
Form6and8.pdf
Tender Documents • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .