Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance C O ANU REFRIGERATION WORKS GANDHI CHOWK PATHANKOT GANDHI CHOWK PATHANAKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical Technically disqualified |
| 3 | Rejected-Technical | Rejected-Technical Technically disqualified |
Tender Value
Refer Docs
Closing Date
27 Apr 2021, 11:30 amClosed
Sr. Manager (Contracts)
Procurement- Contract Divison, Tanakpur Power Station, Banbassa , Champawat
Rewiring of 06 Nos A Type and 12 Nos B Type Quarters
2021_NHPC_622772_1
NH/TPS/PnC/NIT/2020/ E13041/802/1296 dt 17/03/21
Open Tender
Civil Works
Works
75 days
NHPC Ltd. Tanakpur Power Station, Banbasa
As per tender document
5 documents required · 5 mandatory
₹590
NHPC Ltd. Tanakpur Power Station
Exempted
28 Jun 2021
19 Mar 2021
30 Apr 2021
19 Mar 2021
27 Apr 2021
19 Mar 2021
19 Mar 2021 - 20 Apr 2021
Amount
Rewiring for light point/ fan point/ exhaust fan poaint/ call bell point with 1.5 sq.mm FR LS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/ PVC conduit including dismantling as required.( Group-B )
Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S.box and earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required.Group C.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing 3 pin 5 amp ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Dismantling of existing house wiring in A+B-Type quarter comprising of PVC insulated aluminium conductor cable, wooden board, wooden batten, switch ,sockets, holders etc. as required.
Supplying and fixing 10 A rating, 240/415V 10 KA "C" curve miniture circuit breaker suitable for inductive load of single pole in the exiting MCB DB complete with connection testing and commiissioning etc. as required.
Supplying and fixing 25 A rating, 240/415V 10 KA "C" curve miniture circuit breaker suitable for inductive load of single pole in the exiting MCB DB complete with connection testing and commiissioning etc. as required.
Supplying and fixing 63 A rating, 240V Isolator in the existing MCB DB complete with connection testing and commiissioning etc. as required.
Supplying and fixing 32 A rating, 240/415V 10 KA "C" curve miniture circuit breaker suitable for inductive load of Tripple pole and Nuetral in the exiting MCB DB complete with connection testing and commiissioning etc. as required.
Supplying and fixing 16 way Double Door Single pole and neutral Sheet Steel MCB Distribution bord 240 Volt on surface /recess complete with Tinned copper bus bar , neuteral bus bar earth bar/ Din Bar inter connection power painted including earthing etc as required. ( But without MCB/RCCB/Isolator).
Supplying and fixing 8 way(4+24) Double Door Horizontal Type Three pole and neutral, Sheet Steel, MCB Distribution bord415 Volt on surface /recess complete with Tinned copper bus bar , neuteral bus bar earth bar/ Din Bar inter connection power painted including earthing etc as required. ( But without MCB/RCCB/Isolator).
Supplying and fixing 5/6 amps modular switch on the existing modular plate and switch box including connections but excluding modular plate etc.as required.
Supplying and fixing 2 way 5/6 amps modular switch on the existing modular plate and switch box including connections but excluding modular plate etc.as required.
Supplying and fixing 5/6 amps modular bell push switch on the existing modular plate and switch box including connections but excluding modular plate etc.as required.
Supplying and fixing 3 pin 5/6 A modular socket outlet on the existing modular plate & box including connections but excluding moduler plate etc. as required
Supplying and fixing 15/16 A modular swich on the existing modular plate and swich box including connections but excluding modular plate etc.as required.
Supplying and fixing 6 pin 15/16 A modular socket outlet on the existing modular plate and swich box including connections but excluding modular plate etc.as required.
Supplying and fixing two module stepped type electronic fan regulator on tha existing modular plate swich box including connections but excluding modular plate etc.as required
Supplying and Fixing Call bell /Buzzer suitable for single phase 230V. Complete as required.
Supplying and fixing 2 module (75mm+75mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required.
Supplying and fixing 3 module (100mmX75mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required.
Supplying and fixing 4 module (125mmX75mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required.
Supplying and fixing 6 module (200mmX75mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required.
Supplying and fixing 8 module (125mmX125mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required.
Supplying and fixing 12 module (200mmX150mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required.
Supplying and fixing 20A, 240,V SPN industrial type socket outlet, with 2 pole and earth,metal enclosed plug top alongwith 20A 'C' curve, SP,MCB,in sheet steel enclosure,on surface or in recess, with chained matan cover for tha socket out let and complete with connections, testing and commissioning etc.as required.
Wiring for submain wiring alongwith earth wire with the 2x 2.5 sq. mm+ 1x 2.5 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required.
Wiring for submain wiring alongwith earth wire with the 2 x 4 sq. mm+ 1x4 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required.
Supplying and fixing of 25mm of medium class PVC conduit along with accessories in surface /recess including cutting tha wal and making good tha same in case of recessed conduit as required.
Wiring for submain wiring along with earth wire with the 2 x 10 sq. mm + 1x6 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required.
Earthing with copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7metre long etc.with charcoal / coke and salt as required.
Supplying and laying 6 SWG G I wire at 0.50 metre below ground level for conductor earth electrode, including connection / termination with GI thimble etc. as required.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .