Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC RANGAPARA TOWN WARD NO 1 PS PO RANGAPARA DIST SONITPUR ASSAM | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹22.7 L+₹3.2 L (16.3%)Rejected-Finance AMBAGAN TEZPUR TOWN PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹22.7 L+₹3.2 L (16.4%)Rejected-Finance P O P S MISSAMARI DIST SONITPUR ASSAM 784506 | SONITPUR | ASSAM | 784506 | L3 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
27 Nov 2020, 6:00 pmClosed
GE MISAMARI
PO-Missamari Dist-Sonitpur Assam
REPAIR/REPLACEMENT OF LT OH LINE, LT PANEL AND SECURITY/STREET LIGHT AT AF STATION UNDER GE MISAMARI
2020_MES_391418_1
8142
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE MISAMARI
PLEASE REFER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹500
Yes
GE MISAMARI
₹52,000
Yes
8 Dec 2020
31 Oct 2020
30 Nov 2020
31 Oct 2020
27 Nov 2020
14 Nov 2020
31 Oct 2020 - 6 Nov 2020
Amount
Taking down unservicable high mast light fittings of any height/watt/make, repair the same in site by opening cover, replace the unsv parts such as ballasts, lamps, holder, ignitor, capacitor and unsv/burnt cable etc as required at site, after repairing fixing at same position complete all as specified and directed. NOTE: (a)Parts required for replacement shall be measured and paid separately under inrespective item (b)Labour element for replacement of unserviceable parts will be deemed to be included in quoted rates.
Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description laying in trenches or fixing with Walls/Poles, segreating serviceable Bricks/Precast covers, Pipes, Cables etc, and keep in safe custody for reuse, complete all as specified and as directed. NOTE: Earthwork will be measured and paid under appropriate Items.
Dismantling unserviceable LT Poles of any description and any size including demolition of Cement Concrete (as/if required) and made good disturbed Ground, complete all as specified and as directed. NOTE: Unserviceable Poles will be dismantled at Ground Level and disturbed ground will made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately.
Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc., complete all as specified and as directed.
Dismantling Insulators like Pin type, Shackle type from existing Street/ Security Light Pole of any description and any size, seggregating Seviceable Insulators and keep in safe custody for re-use, complete all as specified and as directed.
Dismantling ACSR or AAC Conductors from the Disturbed Span including Line Spacer, etc., complete all as specified and as directed.
Dismantling Earth Wire, Cradle Guarding, etc., complete all as specified and as directed.
Dismantling Stay Assembly of any description and any size including Mild Steel Clamps with Bolts, Nuts and Washers etc., complete all as specified and as directed. NOTE: Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed ground will made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately.
Excavation in Trenches not exc 1.50 Metre wide and not exc 1.50 METRE depth for laying of UG Cable/Pole/Stays etc getting out in Soft/Loose Soil, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre wide and exc. 1.50 Metre but not exc. 3.00 Metre in depth, for Foundation of Pole/Stays, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed.
Removing Surplus Soil to a distance not exc 50.00 Metre away and depositing where directed at a level not exc 1.50 Metre above the Starting Point, complete all as specified and as directed.
M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after lay-ing the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE: For the purpose of Payment, Punned thickness of Sand Cushioning only shall be measured and paid for.
S&F Sub-Class ‘B’ Brick, well burnt, laid breadthwise along the length of Cable laid in trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed.
M&L for taking down unserviceable Street/security Light Fitting of any Watt/Make, repairing the same by opening Cover, re-wir-ing the Light Fitting with 2.5 Sqmm Copper Conductor Cable, multi-stranded, replacing unserviceable Parts as required/ordered, re-fix ing Light Fitting in Original Position after repaired and connecting up, complete all as specified and as directed. NOTE:– (a) Spare Parts such as Lamp, Holder, Ignitor, etc. wherever required will be measured and paid under appropriate Item(s) as ‘Supply only’. (b) Labour Element for replacement of unserviceable Parts is deemed to be included in the QUOTED UNIT RATE.
S&F Junction Box for Street Lights of size 350 x 300 x 112 mm made out of CRCA sheet 2mm thick totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 42 protection single leaf shutter in front having proper locking arrangements, and painted with powder coating paint and suitable size of "connectwell" stud teriminal (provision for socket bolting)- 05 Nos suitable for 415 volts, 50 Hz, 3 phase 4 wire internal wiring system including MCB TPN 06 to 32 amps- 01 No and mounted on security light pole with suitable clamps, nuts, bolts complete all as specified and directed.
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 60 watts with pre wired and necessary mounting arrangements and provision of 4sq mm twin core copper conductor cable multi stranded from fitting to over head line including necessary GI pipe medium grade, bracket 32 mm dia 1.5 mtr long bend to required shape and taking down old unserviceable Street Light Fitting form Electric Pole of any description complete all as specified and as directed. Make:Bajaj Cat part no. BRTFG 60W LED V3 or Equivalent make of Havells/Philips/Crompton Greaves.
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 45 watts with pre wired and necessary mounting arrangements and provision of 4sq mm twin core copper conductor cable multi stranded from fitting to over head line including necessary GI pipe medium grade, bracket 32 mm dia 1.5 mtr long bend to required shape and taking down old unserviceable Street Light Fitting form Electric Pole of any description complete all as specified and as directed. Make:Bajaj Cat part no. BRTFG 45W LED or Equivalent make of Havells/Philips/Crompton Greaves.
S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 flood light fitting luminaire with high power LEDs as light source and electronic driver of capacity 100 watts with pre wired and necessary mounting arrangements and provision of 4sq mm 3core flexable copper conductor cable multi stranded from fitting to junction box including necessary connected to existing points in hanger beam angle, complete all as specified and as directed. Make:Havells, cat no. JETAIRISFLS100WLED757ASYMLTG or equivalent Crompton, Greaves/Philips
S&F FRLSH Single core Conductor 2.5 Sqmm for repair and replacement in panel / fixing of Street of repaired light complete all as specified and directed.
Material and labour for replacement of Street Light Connection using solid copper conductor single core PVC insulated 2.5 sqmm cable for fixing to OH conductor, complete all as specified and as directed.
Supply only Porcelain Holder Pin Type / Thread type with Spring Loaded Contact Point (as approved) suitable for LED Lamp,complete all as specified and as directed.
Supply in repair LED 30watt Lamp as approved in existing position without takingdown light fitting from the pole, including cleaning of perplex cover and refixing of cover in original position,complete all as specified and as directed.
Supply in repair Electronic LED Driver of Capacity 45 Watt, suitable for 220/230/240 Volt, complete all as specified and as directed.
Supply in repair Electronic LED Driver of Capacity 60 Watt, suitable for 220/230/240 Volt, complete all as specified and as directed.
Supply in repair Electronic LED Driver of Capacity 90 Watt, suitable for 220/230/240 Volt, complete all as specified and as directed.
Supply in repair Electronic LED Driver of Capacity 100 Watt, suitable for 220/230/240 Volt, complete all as specified and as directed.
Supply only Electronic LED Driver of Capacity 150 Watt, suitable for 220/230/240 Volt, complete all as specified and as directed.
Supply only Electronic LED DC Driver of Capacity 10-12 Watt, suitable for 220/230/240 Volt, complete all as specified and as directed.Make :- Prozone, Philips ,Bajaj , Havells
M&L Street Light Fitting Bracket made out of GI pipe medium grade, 40 mm dia 1.5 mtr long bend to required shape and fixing to pole poles, walls etc., including supply and fixing of MS Clamp, nut-bolts as required duly painted with two coats of aluminium paint over a coat of red oxide primer, including taking down old unserviceable Street Light Fitting bracket, complete all as specified and as directed.
S&F Surface Mounting Astronomical Time Switches 240 Volt, 50 Hz, two module, and connecting with contactor including taking down old unserviceable Time Switch, complete all as specified and as directed. Model:- AUTS02AST00, Make :- L&T or equivalent in Havells , bajaj
S&F Contactor suitable for Street Light Time Switch 4 Pole, 100 Amp, 415 Volt, including taking down old unserviceable Contactor, complete all as specified and as directed
S&F Water Proof outdoor enclosure for accomodating time switches and contactor and control wiring, complete all as specified and as directed
S&F RED,YELLOW, BLUE INDICATOR Light ,1 Module for fixing in outdoor Automation of Security Light, Complete all as specified and directed.
Material and labour for refixing of Time Swiches and suitable contactor incl replacement of panel control wiring using solid copper conductor single core PVC insulated 2.5 sqmm Control cable for Time Switches,indicators and Contactor, Complete all as specified and directed.
S&F LEDs aviation light energy saving new generation environmental friendly long life versatile presure die cast aluminium housing with polycarbonet enclosure with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 and for fixing taking GI pipe pipe medium grade 40 mm dia 1.5 mtr long, complete all as specified and as directed. (Make :- BAJAJ, Cat Part No-110731 or equivalent in Havells/Phillips as approved by GE).
S & F 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of 10 Sqmm, served with inner sheathing of PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm supension wire , twin core cable flat or circular cable incl taking down old unsv cable complete all as specified and directed .
M&L Cement Concrete 1:3:6 type C2 (40mm graded aggregate) as Lean Concrete in Foundation of Poles, Stay Assembly, etc., including Form-work (as/if required), complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm graded aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as/if required) complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm graded aggregate) as in Coping of Poles, etc. and finishing the Concrete surfaces Fair and Even including necessary Formwork required at Site(s), complete all as specified and as directed.
Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-31 (9.0 Metre long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Painting over a coat of Aluminium Primer (Externally from Top of Coping) including writing MES Pole No. with Synthetic Enamel Paint (First Grade/quality), complete all as specified and as directed. NOTE: Earthwork, Cement Concrete, etc. will be measured and paid under approprite Items.
M&L Stay Assembly complete with Accessories as show in Electrical Plate No. 1 of MES Schedule Part-I, diameter of Stay Rod 16mm, size of Plate 230x230x6mm including 7/3.15 mm Galvanised Stay Strand, complete all as specified and as directed. NOTE: Earthwork, Cement Concrete, Mild Steel Stay Clamps with Bolts, Nuts, etc., Loop Insulator, etc. will be measured and paid under approprite Items.
M&L Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ direct-ed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed.
Refixing only Cross-arms, Bracings, Supports, Clamps and Back Plates (serviceable materials i.e. Structural Steel Sections obtained from Item No. 43 here-in-before) including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed.
S&F Insulator Pin type Porcelain, Vitreous, White, Brown or Green including one Galva-nised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, 100mm Height, 65mm dia for 1100 Volt grade complete all as specified and as directed.
Fixing only Insulator Pin type Porcelain, Vitreous including one Galvanised Mild Steel Spindle Two Galvanised Iron Washers and One Galvanised Iron Nut, 100mm Height, 65mm dia for 1100 Volt grade (Serviceable Insulator opbtained from Item No. 10 here-in- before) complete all as specified and as directed.
S&F Shackle type, Porcelain, Vitreous, White or Brown Insulator of size 100mm height 115mm dia including Galvanised Mild Steel 31x5mm Strap, 14mm dia Insulator Bolts, Nuts, Washers, etc. for Working Pressure 1100 Volt, complete all as specified and as directed.
Fixing only Shackle type Porcelain, Vitreous of size 100mm height 115mm dia including Galvanised Mild Steel 31x5mm Strap, 14mm dia Insulator Bolts, Nuts, Washers, etc. for Working Pressure 1100 Volt grade (Serviceable Insulator opbtained from Item No. 22 here-in-before), complete all as specified and as directed.
S&F Loop Type Insulator Vitreous White, Brown or Green, large size with overall dimensions 90x65mm, clearance of hole 16mm dia, complete all as specified and as directed.
S&F Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) with permissible Sags and providing Jumper, etc., fixing on Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening, etc., complete all as specified and as directed. NOTE: Cost of Binding Wire is deemed to be included in the QUOTED UNIT RATE.
Labour for Releasing ACSR Conductor of existing OH Lines by un-binding from Insulator of any description, re-fixing after stretching, re-stringing the Conductor, removing excess Sag, maintaining proper distance between Conductors as ordered, and binding to insulators with Aluminium Binding Wire complete all as specified and as directed. NOTE: Cost of Binding Wire is deemed to be included in the Quoted Unit Rate.
S&F Galvanised Steel Wire 3.15 or 4.0mm dia as Earth Continuity Conductor and fixed to Pole, binding with Aluminium Binding Wire, complete all as specified and as directed. NOTE: Cost of Binding Wire will deem to be included in the QUOTED UNIT RATE.
S&F Cradles, hexagonal/ rectangular fabricated with Galvanised Steel Wire with 4.00mm dia including binding with Aluminium Binding Wire, complete all as specified and as directed. NOTE: Cost of Binding Wire is deemed to be included in the QUOTED UNIT RATE.
Labour for Releasing GI Wire of existing OH Lines by un-binding from Insulator of any description, re-fixing after stretching, re-stringing GI Wire, removing excess Sag, maintaining proper distance between Conductors as ordered, and binding to insulators with Aluminium Binding Wire complete all as specified and as directed. NOTE: Cost of Binding Wire is deemed to be included in the Quoted Unit Rate.
S&F PVC/Fibre Separator for LT Lines 1100 Volts OH Conductor 2 Wire system for horizontal spacing of Conductor, fixing with Nuts, Bolts, Washers, etc., including taking old unserviceable one, complete all as specified and as directed.
S&F PVC/Fibre Separator for LT Lines 1100 Volts OH Conductor 4 Wire system for horizontal spacing of Conductor, fixing with Nuts, Bolts, Washers, etc ,including taking old unserviceable one, complete all as specified and as directed.
Supply & laying LT UG XLPE sheathed PVC insulated, screened PVC bedded, Galvanised Steel Strip of Wire armoured Electric Power Cable heavy duty with stranded Aluminium Conductor 1100 Volt grade, cross-sectional area 300 Sqmm 3.5 Core, laid in trenches/surface of Wall/in GI Pipe along with Pole for connec-tion to OH Lines including Brass Cable Glands Mild Steel Flat Iron Clamps, etc. and Testing, complete all as specified and as directed. NOTE : Earthwork, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
All as per Item No.57 here-in-above, but 95 Sqmm x 3.5 Core, Complete all as specified and as directed.
All as per Item No.57 here-in-above, but 70 Sqmm x 3.5 Core, Complete all as specified and as directed.
All as per Item No.57 here-in-above, but 50 Sqmm x 3.5 Core, Complete all as specified and as directed.
All as per Item No.57 here-in-above, but 35 Sqmm x 4.0 Core, Complete all as specified and as directed.
All as per Item No.57 here-in-above, but 25 Sqmm x 4.0 Core, Complete all as specified and as directed.
All as per Item No.57 here-in-above, but 16 Sqmm x 2.0 Core, Complete all as specified and as directed.
S&F Galvanised Iron Pipe 50mm bore (dia), Light grade as in protection of UG Cable laid in Trenches/ fixing with Poles with Mild Steel Flat Iron Clamps, complete all as specified and as directed. NOTE: Cost of Mild Steel Clamp, Nuts, Bolts and painting is deemed to be included in the QUOTED UNIT RATE.
All as per Item No.64 here-in-above, but 40 mm, Complete all as specified and as directed.
All as per Item No.64 here-in-above, but 80 mm, Complete all as specified and as directed.
Laying/ Fixing only Galvanised Iron Pipe 50mm bore (dia), as in protection of UG Cable (Serviceable Pipe opbtained from Item No. 13 here-in-before) laid in Trenches/fixing with Poles with Mild Steel Flat Iron Clamps, complete all as specified and as directed. NOTE: Cost of Mild Steel Clamp, Nuts, Bolts and painting is deemed to be included in the QUOTED UNIT RATE.
All as per Item No.67 here-in-above, but 40 mm, Complete all as specified and as directed.
All as per Item No.67 here-in-above, but 80 mm, Complete all as specified and as directed.
M&L preparing old painted surfaces by scraping and removing old paints, rust, etc. from steel tubular Pole (above the Planting Depth and PCC Copings of 9.0 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying Two Coats of Synthetic Enamel Painting in alternate Yellow & Black Strips Painting (4 No. Each Strip 150 mm wide) and remaining portion of Pole treated with Two Coats of Exterior Weather Proof Paint and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paint, complete all as specified and as directed.
M&L preparing old painted surfaces by scraping and removing old paints, rust, etc. from steel tubular Pole (above the Planting Depth and PCC Copings of 11.0 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying Two Coats of Synthetic Enamel Painting in alternate Yellow & Black Strips Painting (4 No. Each Strip 150 mm wide) and remaining portion of Pole treated with Two Coats of Exterior Weather Proof Paint and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paint, complete all as specified and as directed.
M&L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Pre-stressed Concrete Pole (above the Planting Depth and PCC Copings of 8.5/9.0 Metre length Pole) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying Two Coats of Synthetic Enamel Painting in alternate Yellow & Black Strips Painting (4 No. Each Strip 200 mm wide) and remaining portion of Pole treated with Two Coats of Exterior Weather Proof Paint and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paint, complete all as specified and as directed.
M&L Writing Lettering on Steel Tubular/Pre-stressed Concrete Pole (8 Cm in height) with Synthetic Enamel Paint (White) on base of Black Paint in round shape of 15 Cm dia, complete all as specified and as directed.
Treaming of Tree Branch, girth not exc. 50 mm around OH Electric Lines and cleaning upto 3.00 Metre from the OH Electric Lines, removing tremmed Branches from Site(s) and stacking as ordered, complete all as specified and as directed.
Treaming of Tree Branch, girth exc. 50mm but not exc. 100 around OH Electric Lines and cleaning upto 3.00 Metre from the OH Electric Lines, removing tremmed Branches from Site(s) and stacking as ordered, complete all as specified and as directed.
Treaming of Tree Branch, girth exc. 100mm but not exc. 150 around OH Electric Lines and cleaning upto 3.00 Metre from the OH Electric Lines, removing tremmed Branches from Site(s) and stacking as ordered, complete all as specified and as directed. Note : The Item shall be operated maximum 2 times in the entire period of the Contract and the measurement will be taken every time independently for Payment.
Cutting unaxious green groth and wild grass by manual labour or by machine at Electrical Installation Premises, around Pole, along the boundary Fencing, removing rubbish from the Site of Work and deposting where directed not exc. 100 Metre from the starting Point, complete all as specified and as directed. NOTE : The Item shall be operated maximum 2 times in the entire period of the Contract and the measurement will be taken every time independently for Payment.
S & F including connecting and testing MCCB 4 pole 63 Amps with thermal magnetic release breaking capacity 35 KA capacity, suitable for 415 volts, 50 Hz, with extended terminals type, interlocked to prevent opening when the Switch is in ON Position in existing LT Panel complete including removal of exiting unserviceable, complete all as specified and directed.Make: L&T/Havells/Legrand
All as per Item no.78 here in before but for 4 pole 100 Amps with thermal magnetic release breaking capacity 35KA.
All as per Item no. 78 here in before but for 4 pole 160 Amps with thermal magnetic release breaking capacity 36KA.
All as per Item no. 78 here in before but for 4 pole 200 Amps with thermal magnetic release breaking capacity 36KA.
All as per Item no.78 here in before but for 4 pole 400 Amps with thermal magnetic release breaking capacity 36KA.
M&L LT digital Amp meter of size 96x96mm 0 to 200 Amp,Class 1, complete all as specified and as directed. Make : L&T
M&L LT digital volt meter of size 96x96mm 0 to 500 volts ,Class 1, complete all as specified and as directed. Make : L&T
M&L LT CTs of rating 200/5 Amp, complete all as specified and as directed. Make : L&T
Cutting out the burnt out cable end and reconnecting with providing new lugs,tapes etc for cable size 25 sqmm 3.5 core to 50 sqmm 3.5 core, complete all as specified and directed.
Cutting out the burnt out cable end and reconnecting with providing new lugs,tapes etc for cable size 70 sqmm 3.5 core to 95 sqmm 3.5 core, complete all as specified and directed.
Cutting out the burnt out cable end and reconnecting with providing new lugs,tapes etc for cable size 120 sqmm 3.5 core to 300 sqmm 3.5 core, complete all as specified and directed.
Supply and fixing in replacement of old unserviceable Four pole onload changeover switch with advanced neutral having current rating 200 Amp with phase barrier & handle with door interlock kit in open execution, complete all as specified and directed.Make-L&T, equivalent of C&S and Havells.
Supply and fixing in replacement of old unserviceable Four pole onload changeover switch with advanced neutral having current rating 400 Amp with phase barrier & handle with door interlock kit in open execution, complete all as specified and directed.Make-L&T, equivalent of C&S and Havells.
S&F copper thimble for cable size of 300 Sqmm, complete all as specified and directed.
S&F copper thimble for cable size of 95-120 Sqmm, complete all as specified and directed.
S&F copper thimble for cable size of 70 Sqmm, complete all as specified and directed.
S&F copper thimble for cable size of 50 Sqmm, complete all as specified and directed.
S&F copper thimble for cable size of 35 Sqmm, complete all as specified and directed.
All as per srl item No 95 above but for cable size of 25 Sqmm, complete all as specified and directed.
All as per srl item No 95 above but for cable size of 16 Sqmm, complete all as specified and directed.
Replacement of old unsv rubber mat with the new rubber mat suitable for LT panel of size 2mx1mx15mm thick,ISI marked, complete all as specified and directed. Make : Deep Jyoti
S&F Straight Through Joints (Epoxy Type) including Jointing Kit complete for making Joints suitable for UG Aluminium Conductor Cable 35 Sqmm to 50 Sqmm, 3½ Core, complete all as specified and as directed.
S&F Straight Through Joints (Epoxy Type) including Jointing Kit complete for making Joints suitable for UG Aluminium Conductor Cable 70 Sqmm to 95 Sqmm, 3½ Core, complete all as specified and as directed.
S&F Copper strip 20 x 3.15mm with saddles and fixing screws and run through wall provided with nonconducting plank etc.for down conductors for lighting arrester, complete all as specified and as directed.
S & F Air Termination, single pointed copper rod 12 mm dia and 300 mm long complete fixed with brazing alll as specified and directed complete all as specified and as directed.
S & F Test point terminal block made of gun metal or Phosphorus bronze size 75 x 75 x 25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw complete all as specified and as directed.
Boring holes horizontally under Road without damaging the surface of Road of any type (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 40mm bore (dia) for passing of UG Cable, complete all as specified and as directed. NOTE: GI Pipe laid will be measured and paid separately under appropriate Item.
M&L Earthing with Galvanised Steel Earth Plate Electrode 600x600 x6mm, buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth strip of size 32x6 mm dia by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and Earth Strip protected with and including GI Pipe 40mm bore (dia) light grade upto 1.0 Metre above the Floor Level of Building where Main Switch/DB situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded aggre-gate), reinforced with 8mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion, complete all as specified and as directed.
M&L Earthing with Galvanised Steel Earth Plate Electrode 600x600 x6mm, buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised earth lead wire 4.0mm means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and Earth Strip protected with and including GI Pipe 20mm bore (dia) light grade upto 1.0 Metre above the Floor Level of Building where Main Switch/DB situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded aggre-gate), reinforced with 8mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion, complete all as specified and as directed.
M&L Earthing with Copper Earth Plate Electrode 600x600 x3.15mm, buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to copper earth strip 32x6mm means of Bolts, Nuts, Check Nuts and Washers and Earth Strip protected with and including GI Pipe 40mm bore (dia) light grade upto 1.0 Metre above the Floor Level of Building where Main Switch/DB situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150 mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded aggre-gate), reinforced with 8mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion, complete all as specified and as directed.
M/S S.S.Corporation
M/S RANA ENGINEERING ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .