Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC | L1 | Accepted-AOC l1 | |
| 2 | L2₹20.5 L+₹3.2 L (18.6%)Rejected-AOC OFFICE NO 507 ELLORA FIESTA PLOT NO 08 SANPADA SECTOR 11 NAVI MUMBAI MAHARASHTRA 400705 | THANE | MAHARASHTRA | 400705 | L2 | Rejected-AOC l2 | |
| 3 | L3₹25.6 L+₹8.4 L (48.6%)Rejected-AOC | L3 | Rejected-AOC l3 | |
| 4 | Rejected-Technical 6 270 LALITA PARK LALITA PARK LAXMI NAGAR EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | - | Rejected-Technical Details in notice |
Tender Value
₹11.2 L
EMD Value
₹11,200
Closing Date
2 Jul 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Managing Director
Kerala Medical Services Corporation Ltd
Generator 160 KVA
2020_KMSCL_349530_8
KMSCL/EP/T365(R)/2020
Open Tender
Equipments
Item Wise
56 days
Kerala Medical Services Corporation
Please refer tender document
24 documents required · 24 mandatory
₹2,006
Yes
online
₹11,200
Yes
13 Jul 2021
12 Mar 2020
7 Jul 2020
12 Mar 2020
2 Jul 2020
12 Mar 2020
180 days
Supply, Installation, testing and commissioning of 160 KVA Diesel generator except the following
RCC Foundation for housing the DG Set (above 62.5 KVA) in the ratio 1:2:4 (M-20 grade) with 20mm metal, 10 mm reinforcement on both sides 15 cm c/c and cement plastering. (Foundation should be constructed by providing additional 1 feet extension of the DG Dimension on each side. Also the the height of foundation should be 30 cm above ground level)
Supply of suitable size extra MS exhaust line as per standard including factory made bends, flanges, nut, bolt and necessary supports and covered with laying of Glass wool and cladding with aluminium with accessories pipe and silencer wherever necessary suitable for DG set supplied. (Per Meter)
4 No's of GI Plate earthing pits required for the DG set including construction of earth chamber and covering with heavy duty cast iron cover hinged to cast iron frame including Providing and fixing 25 mm X 5 mm Copper strip on surface or in recess for connections etc. as required. The distance between 2 pits shall beminimum 3 metres
All the electrical connections to the existing busbar/ system through change over switch and commissioning with suitable cable of size 1.1 KV grade 185 Sq mm 4 core (Per Meter) . The laying of cable shall be as per the KSEI standards, which includes Laying directly on wall surface (clamped with 40 x 3mm MS flat clamp)
All the electrical connections to the existing busbar/ system through change over switch and commissioning with PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade size 185 Sq mm 4 core(Per Meter). Laying of cable in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering
All the electrical connections to the existing busbar/ system through change over switch and commissioning with PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade size 185 Sq mm 4 core(Per Meter). Laying of cable in in the RCC/ HUME / STONE WARE/ GI/ DWC pipe as required (For Road Crossing etc)
All the electrical connections to the existing busbar/ system through change over switch and commissioning with PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade size 185 Sq mm 4 core(Per Meter). Laying of cable on factory made perforated trays(300mm width and 50mm depth) with required bends.
Canopy with 0.35mm thick powder coated GI sheet for the safeguard of DG set and enclosure to control panels. The sheet should be extended to 90 cm from the foundation on all sides. Truss work shall be with GI frame work sufficient to withstand the sheet roofing and the shall be neatly painted.Minimum Height of Canopy shall be 3.6 Mtrs from the Foundation.
All statutory approval from electrical inspectorate, SPCB, Local bodies etc and the same is to be regularized from KSEB
Supply and installation of Generator AMF control panel with required size of MCCB as incomer each for Mains and DG supply , contactors of required specifications, necessary indication lamps, control switches, fuses, push bottons, voltmeter, Ammeter, Frequency meter etc
Supply and laying of 12c X 2.5 sq.mm copper cable for AMF Control cabling
Supply and laying of 4c X 2.5 sq.mm copper cable for AMF Control cabling
Supply and installation of 250A 4 pole Manual Changeover switch for necessarry by-pass arrangement if required. (Mains supply By-pass)
The epoxy coating for all the metallic parts of the DG set and its components in costal areas (Not taken for evaluation)
Fuji Technical Services Pvt Ltd
Jeevan Diesels and Electricals Limited
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .