Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC DHALIWAL | AMRITSAR | PUNJAB | 143001 | L1 | Accepted-AOC lowest1 | |
| 2 | L2₹31.1 L+₹1.6 L (5.34%)Rejected-Finance | L2 | Rejected-Finance higher side amount | |
| 3 | L3₹31.6 L+₹2.1 L (7.02%)Rejected-Finance | L3 | Rejected-Finance higher side amount | |
| 4 | L4₹32.4 L+₹2.8 L (9.54%)Rejected-Finance GOVT CONTRACTOR VILLAGE GHUMALI P O AGAR TEHSIL FATEHPUR DISTT KANGRA HP | MANDI | HIMACHAL PRADESH | 175013 | L4 | Rejected-Finance higher side amount | |
| 5 | L5₹34.4 L+₹4.8 L (16.4%)Rejected-Finance SHED NO 9 TAHLIWAL DISTT UNA H P | L5 | Rejected-Finance higher side amount |
Tender Value
₹40.4 L
EMD Value
₹69,000
Closing Date
28 Nov 2019, 11:00 amClosed
Executive Engineer
IPH Division Fatehpur
Sub Head Supply and Erection of Submersible Pumping machinery, Providing, Laying, Jointing and Testing of MSERW Pipe 200 mm dia in Rising Main (T/W Manoh Sihal-II
2019_HPIPH_32657_1
EE-IPH-FTR/EA/019-7814-64
Open Tender
Civil Works
Item Rate
120 days
Tehsil Fatehpur
As Per Notice Inviting Tender
9 documents required · 9 mandatory
₹800
EE IPH Division Fatehpur
₹69,000
Yes
3 Jan 2020
15 Nov 2019
28 Nov 2019
15 Nov 2019
28 Nov 2019
15 Nov 2019
Amount
Supply of submersible Pumping Set of Calama/KSB/Crompton/SU/Johnston conforming to IS-8034-1979 (Latest) suitable for clear water fitted with bronze Impellers or suitable alloys directly cooupled to squirrell cage electric Induction Motor of same make as that of Pump conforming to IS:9238-1979(Latest with uptosate ammendments) and totally water proof for Submersible duty,isolated from the pump by intermediate casing with double Mechanical seal in oil chamber,grease packed lubricated bearings and provided with stainless steel thrust bearing plate to withstand non-vertical loads with minimum wear and tear. It should also be fitted with a device to take-up expansion of water with the heating of motor including water level guard,erection clamps,cable clips and depth gauge etc. The Pump shall be suitable for operation on data given below:-
Location of site :-The site is located at a distance of Kms.from Nurpur Road Railway Station.
The altitude of place in which :-Altitude of place is 500 Metres above Mean Sea Level, the Motor is intended to work
Type of current :-A.C.Three phase supply with frequency 50 cycles per second.
Rated Voltage :-415 Vvolts (+/-) 10%
Characterstics of water :-(a).Temperature = 20oC (f) PH =__7___ (b).Turbidity =Upto 10NTU (g) Total solids____Mg/Litre ©. Hardness =__Mg/Litre(as CaCo3) (h). Others_____ (d).Alkalinity =__Mg/Litre(as CaCo3)
Depth of Well Assembly :-140.80.00 Metres.
L.W.L.in Tube-Well :- 377 Metres
Maximum draw down :- 36.00 Metres
Centre line level of Pump :-37.70 Metres
Discharge level of highest point:- 416.00 Metres
Nos.of Pumps required :-1 No.Pump.
Capacity :- 24.96 L.P.S.
Total head in Metres :- 44.00 Metres
Length of Rising Main :- 15.00 Metre
Dia of Rising Main :- 200 mm Dia MSERW
No.of working hours per day :-20.00 Hours.
Limits of pump operation :- ( - ) 15% ( + ) 10% of total head.
H.P.of Motor/Drive unit :-Required 30 H.P.of Pump at ( + ) 10% and ( - ) 15% of total head.
BHP.with following margins/multiplying factor at duty point,whichever is higher.
Providing C.I.double flanged sluice valve of Kirloskar/Kilburn/IVC.\/Fouress/Gled/BHEL/Leader make of size suitable as per offered pump and Class PN 1.0 having one size higher to delivery size of Pump and capable of withstanding nominal seat pressure of 10.20Kgs/Cm2. conforming to IS 780-1984 (P-I) NOTE:-The C.I.Sluice valve shall conform to IS-780-1984(Latest edition). However if the seat pressure exceeds the limits prescribed in BIS-780-1984 then it shall be of cast steel conforming to Class-150 ASA(seat pressure 21 Kgs./cm<2.) or class 300 ASA(Seat pressure 52Kgs./Cm3)as per BS-1414(API-600).
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make C.I. double flanged swing Check type Reflux Valve having bye pass arrangement and one size higher to delivery size of pump(size 100mm.dia and clasas PN 1.0 and shall be suitable for withstanding nominal seat pressure of _____Kgs.cm<2)conforming to IS: 5312-1984
Supply of Kirloskar/Kilburn/IVC/Foluress/Gled/BHEL/Leader make C.I. double flanged Swing Check Type Reflux Valve having bye pass arrangement and of size equal to dia of Rising Main i.e. 125mm.& class PN 1.0 shall be suitable for withstanding nominal seat pressure of 10.20Kgs./Cm<2).conforming to IS: 5312-1984. Note:-The C.I.Reflux valve shall conform to IS-5312-1984-Part-I(Latest edition). However, if the seat pressure exceeds the limits prescribed in IS-5312-then it shall be of cast steel conforming to Class 150 ASA Seat Pressure 21Kgs/Cm<2) or class 300 ASA)Seat pressure 52Kgs./Cm<2) as per BS 1868(API 6D).
Providing and laying suitable size copper PVC.insulated armoured power 3.5 core cable conforming to BIS- 1554-Part-I -1988 or latest with uptodate ammendments Siemen/Gloster/ICC make from Meter of HPSEB. to MCB/OCB & from OCB to Busbar Switch & Starter(One cable carrying all three phases) including all other elecrc equipments/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipers or trenches size and make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB.auithority shall have to be replaced by the tenderer free of cost. supply side (the size of cable shall be specified by the tenderer).
Providing and laying PVC.jointless flat water proof cable of suitable size as per BIS-694-1990(Latest with uptodate ammendments) suitable for the pump set offered from OCB to Motor, Motor to Starter including all other electric equipment such as;thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipes or trenches under floor. The type & make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB.authoirity,it shall have to be replaced by the tenderer free of cost.Motor side (the size of cable shall be specified by the tenderer).
Providing and laying doub le loop earthing with copper plate 600x600x3mm.thick electrode complete with material such as;char coal,common salt,G.I.Pipes,thimbles,nuts & bolts,digging of pits,G.I.wiring and 25x5mm.copper stripsw of required capacity conforming to BIS-3043-1987 latest with uptodate ammendments for above motors and other electrical equipments.
Supply and erection of floor/wall mounted power factor shunt capacitor conforming to BIS-2834-1986 latest with uptodate ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to Induction Motor individually of required KVAR according to H.P.of Motor offered including Siemens/Gloster/ICC make from Busbar chamber to capacitor and also including LT/LK/Kilburn make ICTP.Switchesconforming to BIS-4064-1978 or latest with HRC fuses(Range to be specified by the tenderer).
Supply of standard make circular dial pressure gauge of suitable range of Fiebeg/Bourden/Precision make with all accessories such as;stop cock,copper tubing etc.conforming to BIS-3624-1987 latest with uptodate ammendments.
Providing and laying of Column Assembly of 125mm.dia and common header 125mm.dia G.I.Pipe Confirmng to IS-1239 or MSERW pipe 4.80mm.thick conforming BIS-1978-82 considering site requirement duly flanged at every 3 Metre length with flanges conforming to BIS-6392-1971(Table-5) including tapers,flanges,rubber gaskets 3mm.thick as as per BIS-2712-1978,nuts & bolts as per 1364-1983 and specials upto collection tank as per directions of Engineer-in-Charge /as per layout approved by the Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total pressure indicated in item No.1(xii).NOTE:- Actual laying tobe done as per final drawings to be approved by the Engineer-in-Charge.
Erection of all equipments from S.No. 1 to 4 and 6 including cost of tees, bends,tapers and any other fittings required as per conditions and as per directions of the Engineer-in-Charge.
Supply of horizontal spindle, horizontal/radial split casing and suction(backpull out arrangement) single/Double/multi stage centrifugal pumps or combination of pumps in series/parallel of BS/SABAR/LUBI/Calama/KSB/Crompton/SU/Johnston approved as per IPH department confirming to BIS:1520-1980 (latestwith upto date amendments) read with BIS:9137-1978 (latest edition) suitable for lifting water of under mentioned characteristics with impellers of bronzes/Suitable alloy, priming funnels, casing ring & shaft sleeves of bronze/suitable alloy, shaft of suitable steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I./Cast steel base plate (base plate to slippering/squired cage screen protected drip proof electric induction motor of KSB/Mather and platt/Kirlokar/ BE/Beaconweir/BEHL/GEC/ABB/conforming to BIS:325-1978 read with BIS:900-1968 (latest with upto date amendments) It should include the cost of bearings. Nuts & bolts, painting etc. and shall be suitable for operation as per data given below. The Pumping machinery shall be installed on proper designed base plate which is to be from the principle manufacturer of pumping set .The foundation of the pumping should be designed and anchored properly
Location of site :- The site is located at a distance of 18 Kms from Nagrota Surian to Jassur
The altitude of place in which the motor is intended to work :- Altitude of place is 450 m above MSL
Type of current :- A.C. Three phase supply with frequency of 50 cycles per second
Rated voltage :- 415 + 10%
Type of water (Raw/Treated) :- _____Clear water____
Charactrstics of water :- a) Temperature _20_°C d) PH 7 to 8 b) Turbidity Upto 10 PPM e) Total Solids __Mg/litre__ c) Hardness __Mg/Liter (as CaCo₃) f) Other: _______
Depth of Well assembly :- 412.00 Mtr.
L.W.L in C/Tank :- 412.00 Mtr.
Center line level of pump :- 412.00 Mtr.
Suction head :- (+) 0.00 mtr.
Discharge level of highest point :- 459.00 mtr.
Nos of pump required :- 1 Nos Pump
Capacity :- 24.90 LPS
Static Head in meters :- 47.00 Mtr.
Total head in mtr :- 55.16 mtr
Length of R/Main :- 750.00 mtr
Dia of R/Main :- 200mm dia(MSERW pipe)
Pumping hours per day :- 20 Hours
Limits of pump operation :- (-) 15% to (+) 10% of Total head at duty point
HP of Motor/Drive unit :- Required BHP of 35 HP at (+) 10% & (-) 15% of total head of BHP with following margins /multiplying factor at duty point, whichever is higher a) UP to 2HP = 1.5 d) 10 to 20 HP = 1.2 b) 2 to 5HP = 1.4 e) 20 to 100 HP = 1.15 c) 5 to 10HP = 1.3 f) Above 100 HP = 1.10
R.P.M. of Pump (2900/1450 rpm) :- _____r.p.m.
Test Run :- 20 hours continueously for 7 days
NPSH available :- ____mts.
Providing C.I.double flanged sluice valve of Kirloskar/Kilburn/IVC.\/Fouress/Gled/BHEL/Leader make of size suitable as per offered pump and Class PN 1.0 having one size higher to delivery size of Pump and capable of withstanding nominal seat pressure of 10.20Kgs/Cm2. conforming to IS 780-1984 (P-I) NOTE:-The C.I.Sluice valve shall conform to IS-780-1984(Latest edition). However if the seat pressure exceeds the limits prescribed in BIS-780-1984 then it shall be of cast steel conforming to Class-150 ASA(seat pressure 21 Kgs./cm<2.) or class 300 ASA(Seat pressure 52Kgs./Cm3)as per BS-1414(API-600).
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make C.I. double flanged swing Check type Reflux Valve having bye pass arrangement and one size higher to delivery size of pump(size 100mm.dia and clasas PN 1.0 and shall be suitable for withstanding nominal seat pressure of _____Kgs.cm<2)conforming to IS: 5312-1984
Supply of Kirloskar/Kilburn/IVC/Foluress/Gled/BHEL/Leader make C.I. double flanged Swing Check Type Reflux Valve having bye pass arrangement and of size equal to dia of Rising Main i.e. 125mm.& class PN 1.0 shall be suitable for withstanding nominal seat pressure of 10.20Kgs./Cm<2).conforming to IS: 5312-1984. Note:-The C.I.Reflux valve shall conform to IS-5312-1984-Part-I(Latest edition). However, if the seat pressure exceeds the limits prescribed in IS-5312-then it shall be of cast steel conforming to Class 150 ASA Seat Pressure 21Kgs/Cm<2) or class 300 ASA)Seat pressure 52Kgs./Cm<2) as per BS 1868(API 6D).
Providing and laying suitable size copper PVC.insulated armoured power 3.5 core cable conforming to BIS- 1554-Part-I -1988 or latest with uptodate ammendments Siemen/Gloster/ICC make from Meter of HPSEB. to MCB/OCB & from OCB to Busbar Switch & Starter(One cable carrying all three phases) including all other elecrc equipments/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipers or trenches size and make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB.auithority shall have to be replaced by the tenderer free of cost. supply side (the size of cable shall be specified by the tenderer).
Providing and laying PVC.jointless flat water proof cable 16mm as per BIS-694-1990(Latest with uptodate ammendments) suitable for the pump set offered from OCB to Motor, Motor to Starter including all other electric equipment such as;thimbles,flexible pipe,solder,nuts & bolts,cable glands etc.laid in pipes or trenches under floor. The type & make will be subject to approval of HPSEB.authorities. In case of non-acceptance by HPSEB.authoirity,it shall have to be replaced by the tenderer free of cost.Motor side (the size of cable shall be specified by the tenderer).
Providing and laying doub le loop earthing with copper plate 600x600x3mm.thick electrode complete with material such as;char coal,common salt,G.I.Pipes,thimbles,nuts & bolts,digging of pits,G.I.wiring and 25x5mm.copper stripsw of required capacity conforming to BIS-3043-1987 latest with uptodate ammendments for above motors and other electrical equipments.
Supply and erection of floor/wall mounted power factor shunt capacitor conforming to BIS-2834-1986 latest with uptodate ammendments BHEL/GEC/Machneil/Mager/Bajaj make to raise the prevailing power factor at site to 0.95 for direct connection to Induction Motor individually of required KVAR according to H.P.of Motor offered including Siemens/Gloster/ICC make from Busbar chamber to capacitor and also including LT/LK/Kilburn make ICTP.Switchesconforming to BIS-4064-1978 or latest with HRC fuses(Range to be specified by the tenderer).
Supply of standard make circular dial pressure gauge of suitable range of Fiebeg/Bourden/Precision make with all accessories such as;stop cock,copper tubing etc.conforming to BIS-3624-1987 latest with uptodate ammendments.
Providing and laying MSERW pipes conforming to BIS: 1978-82 of suitable size for suction, delivery and common header considering site requirements & NPSH required/available. The pipe size forsuction & delivery shall as per the requirement of offered pump and common header shall be equal to dia of R/Main including cost of tapers, flanged (Conforming to relevant table of BIS:6392-1971), bends, rubber gaskets, 3mm thick nuts & bolts and specials up to 5 mtrs away from the outer wall of pump house as per layout drawing approved by Engineer-in-charg. pipe & material shall be capable of with standing field test pressure equal to 1.5 times the operating pressure. The complete arrangement shall comprise of ; a) Suction pipe 200 mm with Table-5 dia 200mm. b) Delivery pipe 150 mm with Table-17dia 150. c) Common header 200 mm with Table-17 dia.200.
Erection of all equipments from S.No. 8 to 11 and 12, 13 including cost of tees, bends,tapers and any other fittings required as per conditions and as per directions of the Engineer-in-Charge.
Excavation in foundation trenches etc.for earth work in all classification of soil such as;spade,pick,jumper,blasting work,soft/hard rock etc.upto all depth ,stacking the excavated soil within all leads and lifts clear from the edge of excavation and then returning the stacked soil in 15cm.layers when requied into plinth sides of foundation etc.consolidating each depoed sited layer by ramming,watering and then disposing of all surplus excavated earth.
Providing and Laying in trenches to be levelled to Garde MSERW Flanged pipe zinc coated confirming to IS:3589 (Latest with upto date ammendments) of nominal size 200 mm dia 4.80 mm thick) duly flanged after 66.00 Mtr interval of pipe with intermediate butt welding joints including the cost of flanges, bends/short piece made from parent tubes of different degree cutting welding and jointing with flanges confirming to tables as specified below of BIS:6392(Latest with upto date ammendments) welded at both ends as per BIS:816 (Latestwith upto date ammendments) with electrode confirming to BIS 814 (Latest with upto date Ammendments) & provided with nuts and bolts BIS:1369 (Latest with upto date ammendments) of required size of 4 mm thick champion make compressed asbestos fiber gasket or synthetic rubber gasket confiirming to BIS:2712 (Latest with upto date ammendments) & approved specifications as per site conditions including flushing, cleaning, and hydraulic testing complete to the best satisfaction of Engineer in chrge.
Providing welding and fixing of MS Flanges confirming to IS:6392-1971(Latest with upto date ammendments) and welding of MS Flanges with G.I. Pipes/MSERW pipes in two layers on both faces to make th joint leake proof(The cost of providing and laying of G.I.PIpes/MSERW Pipe to be mesured and paid seprately). The welding of flanges should confirm to IS 816-1969 with electrodes as per IS 814-1991 and required number of nuts and bolts confirming to IS:1364. The thickness of gasket not less than 3.00 mm confirming to IS:2712-1998. The work shall be done as per entire satisfaction of Engineer in charge with in all leads and lifts (MS Flanges to be welded after 66 Meter interval of pipe).
MS Flanges Table-5 (200 mm dia)
Providing circumferential Butt welding by electric arc welding to following diameter MSERW pipe as per IS:3589-2001 of Garde FE-330, having following wall thickness , welded in requisite number of weld runs as as to achieve the minimum effective throat thickness of weld confirming to IS 816-1991, specifications by using welding electrodes of 2.50 mm to 6.30 mm of Advani Oerlikon (Adore)- CITOJET/ESAB make, confirming to IS 814-1991, at site of work complete in all respect, including manual/Mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer in chrarge.
Sanjay Gaur
sadeep kumar
VARINDER SINGH RANA
Pawan Kumar Sharma Govt Contractor
VIVEK KUMAR
Raj Choudhary
SANJAY SAINI
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .