Loading…
Loading…
Tender Value
₹4.1 Cr
EMD Value
₹4.1 L
Closing Date
25 May 2026, 6:00 pmClosed
Chief Engineer, Gujarat Pavitra yatradham vikas Board, Dr.Jivaraj Mehta bhavan, Block- 2,1st floor, Old Sachivalay, Gandhinagar
Development Of Shree Ramnath Mahadev Temple, At. Petlad, Dist.Anand (2nd Attempt)
301518
03/2026-27
Open
Civil - All
Works
Gandhinagar
3 documents required · 2 mandatory · 1 optional
₹6,000
Secretary, Gujarat Pavitra Yatradham Vikas Board
₹4.1 L
5 May 2026
5 May 2026
5 May 2026
25 May 2026
5 May 2026
NAME OF WORK: DEVELOPMENT AND RESTORATION OF RAMNATH TEMPLE, PETLAD.
BILL OF QUANTITIES
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Demolition including stacking of serviceable materilas and
1 disposal of unserviceable materials with all lead and lift. (i) CMT 12.00 1,071.63
Demolition of Brick work and stone masonry including
stacking of serviceable materilas and disposal of
unserviceable materials with all lead and lift.(ii) In Cement
Dismentaling tiled of stone floors laid in mortar including
stacking of serviceable materilas and disposal of
unserviceable materials with all lead and lift.
Dismentling doors, windows, ventilators etc. (wood or steel)
shutters including chowkhats architraves, holdfasts and other
4 attachment etc. complete and stacking them within all lead Each 55.00 190.19
and lift.(i) Not exceeding 3 Sq.M. in area.
Dismentling C.I. pipes G.S.W.pipes abd A.C. rain water pipes
5 with fittings and clamps including stacking the materials with Rmt 27.00 75.92
all lead and lift ( for any dia, of pipe)
Dismantling santtary fittings like wash basin . W.C. pan Indian
6 and European type, flushing tank etc. including stacking the Each 16.00 410.13
materials with all lead and lift.
Dismentaling of sheet roofing including ridges, Hips, Valleys,
Gutters etc. stacking of serviceable materilas and disposal of
unserviceable materials with all lead and lift.(i) G.I.sheet
Clearance of debris around the heritage building by excavatio
n upto depth 1.50mtr to 2.00 mtr carefully without damaging
the buried architectural parts of the building and collect all th
8 e intact parts at proper place for reuse at CMT 14.00 486.27
the time of restoration work as per direction of
Engineer incharge.
Add extra for sorting lifting & stacking charges for architectur
al parts up to 50m lead.
Removing and scraping of old deteriorated plaster of any
thickness fromm wall / R.C.C member including stacking of
serviceable material and disposal of unserviceable from site
of work with all lead and lift
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Removing of old sulphated lime wash/white or colour wash in
multiple applications without causing damage to the below
stone/brick/plastered surface. Scrubbing (not by scraping
which leaves surfaces scarred and scratched ) with bristle
brushes and hot water ( Care to be taken if the surface is
weak one it will break down). Hot water should be used if the
limewash has an oil or tallow binder. Gentle cleaning with air
abrasive tools can be used if the wall surface is not very
11 week.The final clean will almost invariably have to be carried SMT 2171.00 471.35
out by hand scrubbing and rinsed with clean water on
completion. Including scaffolding two legged mild steel
tubular scaffolding, of width 1200 to1500mm largely free
standing, using H frames or mild steel tubular pipes of
minimum 40 mm diameter and 6mm thick ply. The work
should be done under supervision of a trained conservator
Removal of rust,existing coatings, mill scale, dirt, oil, grease,
and other contaminants from steel.sections/stone surface
using Micro sand with the help of pressure pump.
Dismantling dressed stone work ashlar face stone work,
marble work or precast concrete work manually/ by
mechanical means including stacking of serviceable and
disposal of unserviceable material within 50 metres lead as
per direction of Engineer-in-charge :. It should be kept in
mind that the debris is not thrown from the height which can
cause damage to the building due to vibration. In lime mortar
Careful Demolition of M.S. Jali,Railing etc type of work
manually/ by mechanical means including stacking of steel
14 bars and disposal of unserviceable material within 100 SMT 216.00 93.80
metres lead as per direction of Engineer - incharge.
Dismantling Tiles work in floors and roof laid in cement
mortar including stacking materails within 50 m lead For
thickness of tiles above 25 mm and upto 40 mm.
Raking out joints of stone masonry surface to the required
width and depth, with due care and precaution, by
mechanical / manual means, including preparing and cleaning
the surface for re-pointing/ refilling of joints, including
disposal of rubbish to the dumping ground within 50 metre
Removal of stains, dirt, blackening and other contaminantsfro
mMarble by using the solution of Non Ionic soap diluts
17 with water.The soap solution should be mild and the SMT 1501.00 146.01
recommeded PH Value is
Repointing of raked out joints of Ashlar masonry by using lime
18 mortar 1:1:1 (1Lime:1coarse sand:1 Dolomite) SMT 2111.00 340.90
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Stone consolidation-removing the loose/damaged stone and
19 reconsolidating with new stone/reusable stone with lime CMT 45.00 5,706.70
mortar(1:3) wherever ncessary.
Providing and laying lime concrete with graded brick
aggregate 50 mm nominal size and 50% mortar comprising of
1 lime putty : 2 coarse sand rammed excluding cost of
centring and shuttering.
Mix lime mortar to the lime water which is to be applied with
natural additives like jaggery,soapnut,bhel fruit,etc depends
upon the region Wet the surface.Remove all the dust
21 particles. Apply lime plaster up to required thickness.Rework SMT 117.00 1,376.07
on the plaster to Lime plaster 1:1:1 (1 lime putty : 1 surkhi:
finesand) 12mm thick- single coat
Providing ,Designing & Fixing of New carved Sand stone
(dhrangadhra stone) in all thicknesses wherever required
upto all level/height in plain/ decorative work carved by
manual/machenical methode including base(dasa) ,shaft
,capital of columns , springer ,key stone of arches,
DecorativeLime stone band at plinth level. etc as per old
design including coldroll stainless steel clamp ,copper pins of
required diameter for securing adjacent stones in stone wall
22 lining tem includes cost of adhesive/ safety measure /use of CMT 41.00 68,736.98
specified equipment for workers required to complete the
work.(Overall length , width and thickness of stone (cut stone
/ replaced new stone quantity) will be measured for the
purpose of payment).For Heavy art Work & Figure &
Sculpture minimum Carved Stone Depth 10mm to 15mm
Dutchman Repair of stone sections that are severely
distressed, installation of new Sand stone pieces to match
existing stone as a fascia as mentioned in below items no.
23.1, 23.2, 23.3 and 23.4 as per Engineer - incharge.
23.1 Pain Work Area NOS 50.00 650.40
23.2 Cornice & Moulding Area NOS 50.00 1,706.10
23.3 Heavy Art Work NOS 50.00 2,409.90
23.4 Figure & Sculpture NOS 50.00 2,761.80
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Providing and applying decorative on wall exteriorand interior
of Heritage surface texture Stone finish Texture Paint 1.5 to
2.0 mm th. Decorative acrylic texture surface of specified
brand and manufacture and of approved colour n design as
per details given by The rate also includes for all necessary
items required to complete the job as per design/drawing and
client/consultant's instructions. sub strata to get an average
finish coat thickness of 0.08 to 1.2 mm comprising of three
24 components viz. Dry Stone texture, bonding agent and top SMT 2312.60 1,489.00
coat of glossy finish (Dry Stone texture shall be made from
Dhanghdra and same material) homopolymer emulsion mix
etc,texture finish as per architect selection, complete as
directed by architect and EIC.,The rate also includes for all
necessary items required to complete the work as per
client/consultant's instructions
Providing /supplying & fixing of Helifix make Hi-Fin
reinforcement Bars-Helibar having 6mm Dia MOC. Austenitic
Stainless Ateel ASTM 304 having cross section area 8.3mm2
with UTS 1150n/mm2 at various places where there is cracks
in Stone Msonary /Arches .Item includes HELIFIX & HELIBOND
Grout a special cementitious grout with low expansion ,non-
gasing & injectables with exceptional thixotropic properties is
to be used to bond the stainless steel Hi-Fin reinforcement
bars & pins with the help of pressure gun to be injected in the
slot of stone Masonary .ensuring that it remains tight in the
joint after curing .Item also include Crackbond TE -250ml a
injectable special epoxy resin with the help of Crackbond
applicator ensuring that it covers entire cracked area
wherever required.
Dismentaling of sheet roofing including ridges, Hips, Valleys,
Gutters etc. stacking of serviceable materilas and disposal of
unserviceable materials with all lead and lift.(i) G.I.sheet
Excavation for foundation upto 1.5 m depth including sorting
out and stacking of useful materials and disposing off the
excavated stuff upto 50 Meter lead.(B)Dense or Hard soil
Providing and laying cement concrete 1:3:6 (1 Cement : 3-
Coarse sand : 6- Graded brick bat aggregate 40mm normal
size) and curing complete excluding cost of formwork in (A)
Foundation and Plinth
Providing and laying cement concrete work 1:2:4 (1- Cement :
2- Coarse sand : 4- graded stone aggregates 20 mm nominal
size) and curing complete excluding cost of formwork and
reinforcement for reinforced concrete work in (A)
Foundations, footings, Base or columns and Mass concrete
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Providing and laying cement concrete work 1:2:4 (1-Cement :
2- Coarse sand : 4- graded stone aggregates 20 mm nominal
size) and curing complete excluding cost of formwork and
30 reinforcement for reinforced concrete work in (B) Slabs, CMT 230.00 4,101.23
landing, shelves, Balconis , Lintels, Beams, Girders and
Cantilever upto floor two level.
Providing TMT Bar FE 500D reinforcement for R.C.C. work
31 including bending, binding and placing in position complete Kg 17640.00 76.52
upto floor two level
Brick work using common burnt clay building bricks having
crushing strength not less than 35 kg./Sq.Cm.in foundation
and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine sand)(B)
Brick work using common burnt clay building bricks having
crushing strength not less than 35 kg./Sq.Cm. in G.L to Up to
two floor, level, in Cement Mortar 1:5. (1- Cement : 5 -fine
sand)(B) Conventional (upto 10 ton)
(i) Half brick masonry in common brunt clay building bricks
having crushing strength not less than 35 Kg/Sq.Cm. in
34 Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in SMT 118.00 623.60
foundation and plinth (B) Conventional
Providing 10 mm thick Cement Plaster in single coat on
brick/concrete wall/Ceiling for interior plastering up to floor
two level finishing with a floating coat of neat cement
slurry.(i) Cement mortar 1:3 (1-cement :3-sand) upto two
floors, etc. Complete, as per detailed and directed by EIC.
Providing 10 mm thick Cement Plaster in single coat on
brick/concrete for plastering on ceiling and soffits of stairs
above floor two level finishing with a floating coat of neat
cement slurry.(i) Cement mortar 1:3 (1-cement :3-sand) upto
two floors, etc. Complete, as per detailed and directed by EIC.
Providing 15mm thick cement plaster in single coat on Rough
(Similar)side of single or half brick walls for interior plastering
37 upto floor two level and finished even and smooth in (i) SMT 1957.00 201.76
Cement mortar 1:3 (1-cement:3-sand)
Providing 20 mm thick double coat mala cement plaster on
interior brick / concrete work for plastering comprising of
base coat of 12 mm thick cement plaster in cement mortar (1
38 Cement : 4 coarse sand) in rough finishing and 8 mm thick top SMT 2029.00 281.14
coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished
with trovel including scaffolding curing etc. complete.
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Providing and laying fine dressed sand stone (Dholpur stone
and Bansipahadpur stone flooring Mix two Color Flooring 70-
30%) of any thickness for floor paving of approved size and
pattern over 3 to 4 inches (average) thick base of cement
39 mortar 1 : 6 ( 1 Cement : 6 Sand) with joints finished flush and SMT 980.00 3,754.17
pointed with mortar mixed with pigment of matching colour
:Fine dressed Sand Stone in Design combination given by
Providing and laying fine dressed sand stone of any
thickness for Wall Cladding of approved size and pattern over
3 to 4 inches (average) thick base of cement mortar 1 : 3 (
Cement : 3 Sand) with joints finished flush and pointed with
mortar mixed with pigment of matching colour :Fine dressed
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm
(average) base of cement mortar 1:6 ( 1 cement: 6 coarse
sand) on new surface or fixing on existing flooring by adhesive
41 material including dismentaling of existing flooring and SMT 1847.00 1,453.19
jointed with color cement slurry including finised with flush
pointing & cleaning the surface etc. complete for antiskit
Granite Sill & Jambs
Providing and laying 18 mm thick polished granite stone
machine cut in single piece (Max. available) in tread,Riser, sill
and jambs of door/window frame laid over 10 mm thick
42 cement mortar 1 : 3 (1 cement : 3 coarse sand) and jointed SMT 40.00 2,804.00
with grey cement slurry with matching pigment incl. rubbing
and polishing rounding edge etc. complete colour and shed as
approved by architect engineer in charge
Providing and laying broken chine mosaic flooring for
terrace using 12 mm to 20 mm broken pieces of glazed tiles
to be laid over cement mortar 1:3 to plain or slope and to be
tempered to bring mortar creme out upto surface using
white cement including rounding off junctions and extending
them upto 15 cm along the wall,clearing with water and
oxalic acid etc. as directed.
Providing & Fixing the Chikenmesh - 20 guage(Crimp Jali) of
approved size applying between the RCC and masonry
junction in proper line, level and plumb with all material,
labour, tools, tackles and equipment. Including providing and
fixing the jali with nails, etc complete as directed by the site-
Providing throating or plaster drip and moulding to R.C.C.
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Providing and laying sandwich platform comprising of
a) Sandwich of 18 mm thick single side polish Granite of
approved size, shade and sample on top and 25 mm thick
polished kota in bottom with 25 mm thick cement mortar
(1:4) in between
b) At centre vertical sandwich supports of 25 mm thick two
kota stone on sides and 25 mmCM (1:4) in between and at
both end walls vertical supports of 18 mm thick double side
c) 75 mm raised platform at bottom with kota on top and
50mmC M(1:4) at bottom, kota stone skirting as per design
and approved sample. The rate includes rounding
champhering and mirror polishing of edges , facias of granite
MS support including necessary bonding adhesive (if
required).Rate shall be also inclusive of curing , making holes
& cut outs for sink , washbasin, Pillertap / Bib tap but
excluding the cost of MS work, plumbing fixtures and sink . at
all floors all height etc complete as directed by Engineer In
charge. (Only plan area shall be measured & paid for ).Rate
shall be included all kota & granite mentioned in above.
Providing and fixing 35 mm thick shutters for Doors, windows
and clearstory windows including blackenamelled M.S. butt
hinges with necessary screws. (A) Indian teak wood. (i) Fully
Providing and fixing window having extruded aluminum olour
anodized section frame main outer size 63.50 x 38.10 x
mm,@ Wt 1.094 Kg / Rmt, horizontal two track member size
vertical member of size 61.85 mm x 31.75mm x 1.30 mm @
wt.of 0.659 Kg/mt with sliding shutters of horizontal member
size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt, vertical
member of size 0mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt,
@ Wt. 0.457 Kg/mt with 5 mm thick transparent bronze
colour tinted float glass with powder coated aluminum
fittings and fixtures and transparent silicon sealant glass fixing
to frame as per details etc complete for window
Providing and fixing standared extruded of alluminium
section of size 63mm x 38.10mm x 1.2mm (Jindal Section
:2434, @ Wt. 0.643 Kg/mt) with colour anodized alluminium
frame for ventilation with 5 mm thick frosted glass as details
etc complete for Ventilation
Providing and fixing M.S. grill of required pattern top wooden
frames of windows etc. with M.S.. flats at required spacing
and frame alround square or round headed bolts and nuts or
by screws.including applying a priming coat of red lead paint
and two coats of oil painting etc complete (A)Plain grill
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Providing and fixing combination of Cast Iron & Wrought Iron
51 Gate including installation, locking arrangement, Painting etc. kg 1600.00 207.17
Structural steel work ( Confirming to IS 4923-1997) riveted,
bolted or welded in builtup for all type sections, in framed
work, including cutting, hoisting, fixing in position and
52 applying a priming coat of approved steel primer all complete kg 14122.60 130.52
as per the structural designs and directions of Engineer in
charge.Column ( 122 x 61 x 3.6mm )
Applying priming coat over new steel and other metel surface
after and including preparing the surface by throughly
cleaning, oil,grease, dirt and other foreign matter and scoured
with brushes fine steel wood, scrapers and sand paper with
ready mixed priming paint brushing red lead.
Providing and fixing PUF Insulated continueous sandwich
panels for roofs of total thickness not less than 30 mm made
out from continue line method.Panel shall have 0.5 mm thick
pre coated GI sheet on both side of Polyurethane foam with
external face being corrugated in shape for GI and PU foam
both material.The crest height of the panel shall be of 35mm
minimum wiht 250mm c/c pitch. The Precoated sheet shall be
of minimum 240 mpa steel grade confirming to IS 14246:1995
and shall have zinc coating of 120 gsm as per IS:277 , 5-7
microns epoxy primer on both side of the sheet and polyester
top coat 15-18 micron.The PPGI Sheet shall have protective
guard film of minimum 25 microns to avoid scratches wihile
trasportation.The roof panels are laid over a frame work of
trusses, columns and purlins fixed using 90mm self drilling
bolt with rubber washer including all types of flashings. PU
Foam must be self-extinguishing, fire retardant type having
minimum density of 40 Kg/Cu.mt.( +, - 2 Kgs) including
0.25mm craft paper edging,self tapping screws of required
length and nos.etc complete as per structural design and
direction of Engineer-in-charge.
Wall painting (two coats) with plastic emulsion paint of
approved brand and manufacture on undecorated wall
55 surface to give an even shade including throughly brushing SMT 1171.80 82.03
the surface free from mortar droppings and other foreign
matter and sand papered smooth.
Applying two coats of putty & two coats of primer of
approved brand and manufacture on new wall surface to give
56 an even shade including thoroughly brushing the surface free SMT 1439.80 40.19
from mortar dropping and other foreign matter and sand
papered smooth.
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Wall painting (two coats), celing and sloping roof painting
with plastic emulsion paint of approved brand and
manufacture on undecorated wall and sloped roof ,ceiling
57 surface to give an even shade including throughly brushing SMT 673.00 89.84
the surface free from mortar droppings and other foreign
matter and sand papered smooth.
Finishing wall with weather proof exterior emulsion paint on
wall surface (two coats) to give an required shape even shade
58 after thoroughly brushing the surface to remove all dirt, and SMT 1846.00 119.07
remains of loose powdered materials.etc complete
Providing and fixing 18mm thick granite takati. as per
Architect detail drawing etc as directed by EIC.
Direction sign (Junction board):-Providing and fixing sing
boards made out of 2mm aluminium sheet; size 244 x
122cms. rectangle as as per the design of IRC-67-1977 pre
treated with phospheting process & acid etching; coated with
one coat of epoxy primer and two coats of best quality epoxy
paint; reflectorised with retro refiective sheeting as per latest
M.O.S.T. Specifications; Letters and numerals should be as per
IRC-30-1968, 3.1m long (2 nos) stand post and frame
fabricated from suitable size iron angle of 50 x 50 x 5mm
75x75x6mm as required; painted with best quality epoxy
coatings in black and white bends. the details of symbol or
inscription / numerals for each board shall be as per the
instruction of engineer in charge. The fixing at site shall be in
1:2:4 CC block of size 45 x 45 x 60cms. for each leg. including
excavation curing etc. complete under the supervision of
engineer in charge.(B)High Intensity Grade
Providing wood work in Trusses, Purling, Rafter, Post,Post
61 Plates, wall plates and the like wrought framed, hoisted and Cu.dm 499.00 1,373.86
fixed in position
Providing and fixing wooden planks ceiling with tounged and
grooved jointing and wood screw(frame work and cover
62 fillings to be measured andlaid for separately) (A) Indian Teak SMT 110.00 5,224.28
wood (iii) 25mm thick (upto 10 ton)
Provding and fixing of new Stainless Steel mesh wire net as
per specific material compostion specification & traditional
design including all ornamental work ,curvature , welding,
grinding, buffing, polishing , coating and fitting the same with
necessary nuts and bolts complete, i/c fixing the railing with
necessary accessories & fasteners , bolts etc., of required size,
on the top of the floor or the side of waist slab with suitable
arrangement as per approval of Engineer - incharge.
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Repairing of existing Zarokha as per old design intact
,including replacement of damaged member with masonry
work werever required and finish with lime kara as per
prescribed process a.Item includes cost of shuttering
64 /scaffolding /safety measure /use of specified equipment for Lumsum 1.00 5,05,172.98
workers of building required to complete the work .
minimum 10cmt stone may be used in 1 Zarokha, as per
instruction of EIA & Detail Drawing
Providing mirror polishing to floors and dado preparing the
surface, etc.,complete
66 Melamine polishing on wood work (one or more coat). SMT 250.00 983.16
Providing and erecting two legged mild steel tubular
scaffolding, of width 1200 to1500mm largely free standing,
using H frames or mild steel tubular pipes of minimum 40 mm
diameter,with base plates, fixed or adjustable with necessary
clamps, couplers, brackets for projections, joint pins,pullies
and other accessories, including steel angle or tubular pipe
bracings at adequate intervals, access platforms of metal or
timber planks of span not exceeding 2.5 Metre, including
provision of rubber inserts to pipe ends at points of contact
with structure to avoid damage, with intermediate
Traditional stone work in ashlar masonry construction
technology in lime mortar in proportion similar to the
existing traditional lime mortar (1 Lime: 1 Sand: 1 Khakha:
Surkhi aggregate) in exposed stone work including making
horizontal and vertical grooves 10 mm wide 12 mm deep
complete up to all floors for replacement of loose masonry,
missing, damaged and out of plumb masonry from the
historic structure. The recycled stones or bricks should match
stone or brick in the original masonry in terms of its colour,
texture and course. Dhangadhra sandstone shall be cleaned
and sufficiently wetted before laying to prevent absorption
of water from mortar. Every stone piece shall be carefully
fitted to the adjacent masonry so as to form neat and close
joints. The joints shall be staggered. Chips of stones may be
used wherever necessary to avoid thick mortar beds or joints
and hollow spaces. The course shall be truly horizontal and
the work strictly in plumb. The mortar shall be removed from
the stone faces after the work is completed. The joints should
be raked to provide for key to plaster. All stonework shall be
maintained wet for a minimum period of 10 days, All Stone
Work in Dholpur Stone.
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Traditional stone work in ashlar masonry construction
technology in lime mortar in proportion similar to the
existing traditional lime mortar (1 Lime: 1 Sand: 1 Khakha:
Surkhi aggregate) in exposed stone work including making
horizontal and vertical grooves 10 mm wide 12 mm deep
complete up to all floors for replacement of loose masonry,
missing, damaged and out of plumb masonry from the
historic structure. The recycled stones or bricks should match
stone or brick in the original masonry in terms of its colour,
texture and course. Dhangadhra sandstone shall be cleaned
and sufficiently wetted before laying to prevent absorption
of water from mortar. Every stone piece shall be carefully
fitted to the adjacent masonry so as to form neat and close
joints. The joints shall be staggered. Chips of stones may be
used wherever necessary to avoid thick mortar beds or joints
and hollow spaces. The course shall be truly horizontal and
the work strictly in plumb. The mortar shall be removed from
the stone faces after the work is completed. The joints should
be raked to provide for key to plaster. All stonework shall be
maintained wet for a minimum period of 10 days (ornamental
Works) All Stone Work in Dholpur Stone.
Random rubble masonry with hard stones in foundation and
plinth including levelling with lime concete (1 lime:3surkhi:6
70 coarse sand) with 40mm stone aggregate upto plinth level CMT 14.00 6,224.01
with lime mortar 1:1:1(1Lime: 1Surkhi:1Coarse sand)
Providing and laying lime concrete with graded brick
aggregate 50 mm nominal size and 50% mortar comprising of
1 lime putty : 2 coarse sand rammed excluding cost of
centring and shuttering.
Providing ,Designing & Fixing of New carved Sand stone in all
thicknesses wherever required upto all level/height in
plain/ decorative work carved by manual/machenical
methode including base(dasa) ,shaft ,capital of columns
springer ,key stone of arches, DecorativeLime stone band at
plinth level. etc as per old design including coldroll stainless
steel clamp ,copper pins of required diameter for securing
adjacent stones in stone wall lining tem includes cost of
adhesive/ safety measure /use of specified equipment for
workers required to complete the work.(Overall length
width and thickness of stone (cut stone / replaced new stone
quantity) will be measured for the purpose of payment).For
Heavy art Work & Figure & Sculpture, All Stone Work in
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Providing and fixing pre-cast Rubber Dye / steel Dyeinter
locking concrete block 60mm thick with grade of concrete
M300 pnumatic compressed / vibrated mechanically and as
per approved design Confirming to IS 15658 : 2006 including
35 mm Sand layer for levelling and filling the joint with sand
in proper line and level as per guidlines of IRC : SP 63-2018
Providing and fixing pre-cast concrete kerb stone of gray
cement based concrete block 30cm length,30cm height and
15cm thick of M200 grade concret as per approved design
and including excavation for fixing in proper line and
level,filling the joint with C:M 1:3 (1cement:3fine sand) etc
Providing laying and jointing in true line and level 15mm dia.
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make
PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as
approved by Engineer In Charge. Pipe shall be fixed on the
75 wall with the help of clamp at every two metre C/C or shall Rmt 75.00 71.93
be concelled as directed including necessary fittings etc.
including testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 25mm dia.
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make
PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as
approved by Engineer In Charge. Pipe shall be fixed on the
76 wall with the help of clamp at every two metre C/C or shall Rmt 23.00 90.93
be concelled as directed including necessary fittings etc.
including testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 32mm dia.
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make
PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as
approved by Engineer In Charge. Pipe shall be fixed on the
77 wall with the help of clamp at every two metre C/C or shall Rmt 10.00 117.97
be concelled as directed including necessary fittings etc.
including testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 40mm dia.
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make
PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as
approved by Engineer In Charge. Pipe shall be fixed on the
78 wall with the help of clamp at every two metre C/C or shall Rmt 5.00 146.65
be concelled as directed including necessary fittings etc.
including testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Providing laying and jointing in true line and level 50mm dia.
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make
PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as
approved by Engineer In Charge. Pipe shall be fixed on the
79 wall with the help of clamp at every two metre C/C or shall Rmt 55.00 193.73
be concelled as directed including necessary fittings etc.
including testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Providing and fixing wsh down water closet (European type,
W.C. Pan) with integral P or S trap including jointing the trap
with soil pipe in Cement Mortar 1:1 (1-Cement : 1-fine sand)
(Seal and cover to be measured and paid for separately)(A)
vitreous China Pattern :(i) in white colour
Providing and fixing 12.5 Litres low level flushing cistern with
a pair, of C.I. or Mild brackets, complete with fittings such as
lead valve less syphon, 15mm nom.nal size brass ball valve
with polythene float, C.P brass handle unions and couplings
for connections, with inlet, outlet and overflow pipes, 40mm
81 dia. porcelain enamelled flush bend including cutting holes in Each 9.00 2,346.92
walls and making good the same connecting the flush bend
with cistern and closet (overflow pipe to be measured and
paid for separately)(A) Vitreous China (I) In white colour
Providing and fixing plastic seat and cover for wash down
82 water closer with C.P. brass hinges and rubber buffers. (B) Each 9.00 288.45
Black plastic seal and cover.
83 Providing and fixing toilet paper holder.(A) C.P. Brass Each 9.00 423.75
Providing and fixing washbasin with single hole for pillar tap
with C.I. or M.S. brackets painted white including sutting
84 holes and making good the same but excluding fittings.(A) Each 9.00 1,511.53
Vitreous China:(ii) Flat Back washbasin 550 mm x v 400mm
size. (i) In white colour.
Providing and fixing C.P. brass waste for washbasin or sink.
Providing and fixing M.I. fisher union for washbasin or sink.
Providing and fixing pillar tap, capstan head, screw down
87 high pressure with screws, shanks and back nuts. (i) 15mm Each 9.00 305.67
Providing and fixing chromium plated, bottle trap with
88 necessary couplings of approved quality for wash basin. Each 9.00 292.87
Providing and fixing Rubber plug for sink or wash basin.
Providing and fixing 600mm x 450mm bevelled edge mirrror
of superior glass mounted on 6mm thick A.C. sheet or
plywood sheet and fixing to wooden pluge with C.P. brass
screws and washers.
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Providing and fixing C.P. brass towel rail comlete with C.P.
91 brass brackets fixed to wooden plugs with C.P. brass scews.(B) Each 7.00 610.32
600mm x 20mm size.
Providing and fixing screw down bib taps of following size.(A)
92 Brass screw down bib tap polished bright. (i) 15mm dia. Each 14.00 184.98
93 C.P. Angle stop cock 15 mm Heavy duty with cap Each 30.00 476.00
Providing and fixing Urinal of approved quality including
connection with trap and with integral longitudinal flush
pipe.(A) Squating plate pattern white earthenware 550mm
Providing and fixing ball cock of approved. quality as
directed.(A) Copper Metal (i) 25mm dia.
Providing and fixing ball cock of approved. quality as
directed.(A) Copper Metal (ii) 50mm dia.
Providing laying and jointing in true line and level 32mm dia.
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings make
PRINCE / SUPREME / ASTRAL / FINOLEX or equivalent as
approved by Engineer In Charge. Pipe shall be fixed on the
97 wall with the help of clamp at every two metre C/C or shall Rmt 25.00 117.97
be concelled as directed including necessary fittings etc.
including testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Providing, laying and jointing in true line and level
diametre U.P.V.C (Type B) conforming to IS 13592-1992 with
one end plain and other end socketed with rubber ring, &
fittings conforming to ISI 14735-1999 of approved make for
drainage system pipe line, pipe shall be jointed with each
other with rubber lubricant, pipe shall be fixed on wall using
98 of PVC clamp of the size 110 mm diametre x 149 mm length x Rmt 71.00 868.22
145 mm heigh at every 2000 mm center to center or shall be
concealed in walls as directed including necessary fittings
such as bends, shoes etc. including testing of pipes and joints
and jointed with adhesive solvent cement including cost of all
Providing and fixing PVC SWR Nahni trap IS 14735 for drain -
100 mm diameter with jali of the following nominal diameter
99 of self cleansing design with C.I scread down or hinged grating Each 23.00 580.47
including the cost of cutting and making good the walls.
Providing laying (to level or slopes) and jointing reinforced
concrete Light duty non-pressure pipes I.S. class NP2 of the
following internal diameter with collars and butt ends
prepared for collar joints including testing of joints
complete.(C) 250mm (upto 10 ton)
Providing and fixing S.W. gully trap with C.I. grating brick
masonry chamber and water tight C.I. cover with frame of
101 300mm x 300mm size (inside) with standard weight.(i) Square Each 6.00 1,234.57
mouth traps.(B) 150mm x 100mm size P or R type
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-
cement :2-coarse sand : 4-graded stone aggregate 20mm
nominal size) foundation concrete 1:3:6 mix (1-cement : 3-
coarse sand :6-Brick bats 40 + 50mm size) inside plastering
15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse
sand) finished with a floating coat of neat cement and making
channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse
sand :4-stone aggregate 20mm nominal size) finished smooth
complete including curing and festing (i) Inside size 900mm x
1200mm and 1.5M. deep including C.I. cover with frame size
560mm diameter total weight of cover and frame to be not
less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame
Kg.)(A) With 230mm thick walls of brick msonry using brick
having crushing strength not less than 35Kg. / Sq.cm. in
Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (2) B type
depth 1.50 Metre for 150mm diameter sewer.
(I) Extra rate for constructing B.B. masonry for every
103 additional depth of 0.1M. or Part thereof over item No.24.27 Each 0.84 517.78
(I) for depth from 0.9M to 1.5M.
Providing and fixing cast iron steps of size 500mm x 150mm x
104 22.5mm and painting with two coats of Anti-corrosive paint Each 28.00 205.60
Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire of
1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multistrand copper wires, in following type of
pipe to be erected concealed in/ on surface on wall/ceiling
complete with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected
105 on PVC / Metallic box, single mounting base frame covered no 28.00 424.20
with textured/metallic front plate modules erected on / in
wall / ceiling as per pipe erected, with necessary Lamp
holder/ceiling rose / H.D.Connector as directed.
with medium class Rigid PVC pipe and accessories
Point wiring for secondary light point with 2-1.5 sq.mm &
earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multistrand copper wires, in
following type of pipe to be erected concealed in / flushed on
wall/ceiling, complete with earth continuity and necessary
connection with primary light with accessories erected on
Metal / PVC box covered with 3 mm thick PC(Polycarbonet) /
Acrylic sheet for open / concealed wiring. with necessary
Lamp holder / ceiling rose / H.D.Connector as directed.
with medium class 25 MM DIA Rigid PVC pipe and accessories
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Primary light point controlled by one SP MCB ( Same as above
item but controlling with SP MCB )
Point wiring for FAN with 2-1.5 sq.mm & earthwire of
sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC
insulated multistrand copper wires, in following type of pipe
to be erected concealed in / flushed on wall/ceiling complete
with 6A Modular type switch and hum free EME four or more
step type electronic fan regulator with separately mounted
108 and accessories with earth continuity of following type no 17.00 606.00
erected on PVC / Metallic box, single mounting base frame
covered with textured/metallic front plate modules erected
on / in wall / ceiling as per pipe erected. with necessary
ceiling rose / H.D.Connector as directed.
Point wiring for Looped Plug with 6A Modular type switch &
pin socket erected on PVC / Metallic box, single mounting
109 base frame covered with textured / metallic front plate no 13.00 242.40
modules erected on / in wall / ceiling with following type
Point wiring for Individual Plug with & earthwire of
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multistrand copper wires, in following type of to be
erected concealed in / on surface of wall / ceiling complete
with Modular type switch & 5 pin Plug erected on PVC /
Metallic box covered with appropriate front plate modules
erected on / in wall / ceiling as per pipe erected with
following type of accessories.
[I] For 6A Plug with 2-1.5 sq.mm Cu. Wire
Point wiring for Individual Plug with & earthwire of
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multistrand copper wires, in following type of to be
erected concealed in / on surface of wall / ceiling complete
with Modular type switch & 5 pin Plug erected on PVC /
Metallic box covered with appropriate front plate modules
erected on / in wall / ceiling as per pipe erected with
following type of accessories.
[II] For 16A Plug with 2-2.5 sq.mm Cu. Wire
Wiring for the 250 volts single phase and neutral
amps switched socket outlet with 4.0 sq.mm FRLS flexible
copper conductor 1100 volts grade wires of approved
make with concealed or surface mounted 25 mm dia
medium gauge PVC Conduit including providing and fixing of
16 amps 5 pin switch socket outlet of approved quality color
make & design in 2 mm thick GI box and earthing of
fixtures and the outlet box with 2.5 sq.mm PVC insulated
copper conductor stranded flexible "FRLS" wire.
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI
mark (embossed) RIGID PVC PIPES of following size complete
erected with necessary PVC fittings & Junction boxes fixed
with adhesive solution & Clamps with following type of
erection.2) For erecting concealed in RCC / Brick wall/slab or
113 Open along with continuous fish wire to draw mains, laid in Mtr. 1200.00 32.32
approved manner with plastering by cement mortar &
finishing the surface to match the wall/ceiling.
Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI
mark (embossed) RIGID PVC PIPES of following size complete
erected with necessary PVC fittings & Junction boxes fixed
with adhesive solution & Clamps with following type of
erection.2) For erecting concealed in RCC / Brick wall/slab or
114 open along with continuous fish wire to draw mains, laid in Mtr. 350.00 53.53
approved manner with plastering by cement mortar &
finishing the surface to match the wall/ceiling.
Supply and laying of 32 mm rigid PVC pipe of 1.6-1.8 mm
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI
mark (embossed) RIGID PVC PIPES of following size complete
erected with necessary PVC fittings & Junction boxes fixed
with adhesive solution & Clamps with following type of
erection.2) For erecting concealed in RCC / Brick wall/slab
115 along with continuous fish wire to draw mains, laid in Mtr. 250.00 67.67
approved manner with plastering by cement mortar &
finishing the surface to match the wall/ceiling.
Supply and laying of 40 mm rigid PVC pipe of 1.6-1.8 mm
MAINS : ( not for Point wiring )
Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant PVC
insulated conforms to IS 694, IEC - 227 erected in existing pipe
of following size (Specifically for control panel, relays, power
116 switchgears, motor starters & control wiring) with required mtr 50.00 434.30
size of copper lugs, nuts and bolts if required.
Supplying and Laying of 4 nos. of 10 sq mm Cu. FRLS flexible
wires with 2 nos 4 sqmm Cu. FRLS flexible wires
Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to
be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour
for earth continuity of following size
Supplying and Laying of 4 nos. of 6 sq mm Cu. FRLS flexible
wires with 2 nos 2.5 sqmm Cu. FRLS flexible wires
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to
be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour
118 for earth continuity of following size mtr 50.00 146.45
Supplying and Laying of 2 nos. of 6 sq mm Cu. FRLS flexible
wires with 1 nos 2.5 sqmm Cu. FRLS flexible wires
Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to
be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour
119 for earth continuity of following size mtr 50.00 111.10
Supplying and Laying of 2 nos. of 4 sq mm Cu. FRLS flexible
wires with 1 nos 2.5 sqmm Cu. FRLS flexible wires
Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to
be erected concealed in /flushed on wall/ceiling, with 1.5 sq.
mm copper conductor FRLS PVC insulated stranded wire of
120 green colour for earth continuity of following size mtr 800.00 80.80
Supplying and Laying of 2 nos. of 2.5 sq mm Cu. FRLS flexible
wires with 1 nos 1.5 sqmm Cu. FRLS flexible wires
Distribution Board
Supply, Assembling, grouting, leveling Connecting & testing
D.B of IP 43 of specified make.
Distribution Board-VTPN
121 Supply, Erecting, testing and commissioning of only VTPN D.B. no 1.00 13,099.70
PPI type with space for FPMCB as incoming and space for
DPELMCB and 8 TPMCB as outgoing per phase (i.e. 8 way
VTPN D.B.) of Legrand Make Cat. No.
Distribution Board-TPN
Supply, Erecting, testing and commissioning of only TPN D.B.
PPI type with space for FPMCB as incoming and space for
DPELMCB and 4 SPMCB as outgoing per phase (i.e. 8 way per
phase D.B.) of Hensel Make KV9236M
Distribution Board-SPN
Supply, Erecting, testing and commissioning of SPN D.B. PPI
123 type with space for DPELMCB as incoming and 8 SPMCB as no 2.00 3,977.38
outgoing per phase (i.e. 12 way D.B.) of Hensel Make
Miniature circuit breaker single pole 6A to 32A suitable to
operate on 240 V A.C. system and having breaking capacity
10 KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark
0.5 to 2 A SP MCB
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
126 40Amp SP MCB no 5.00 564.59
Providing & erecting 240 V MCB double pole switch for motor
& inductive load (C Curve) having 10 KA breaking capacity &
127 confirms to IS : 8828 in existing box having following capacity no 5.00 308.05
6 to 32 A DP MCB
Approved make ELCBs / RCCBs conforming to IS: 12640 and
having sensitivity of 30 mA and Short Circuit withstand
capacity of 6 KA and suitable for operation on single phase
240 V. having characteristic of quick action & tripping with all
advance feature & do not incorporate any electronic
component. for following Max. rating erected as directed
25 to 32A / 100 mA DP ELMCB
131 SITC of 6 to 32 A TP MCB (10KA) no 4.00 1,117.06
132 SITC of 40 A TP MCB (10KA) no 2.00 1,644.28
Providing & erecting 415 V MCB Four Pole for Motor &
Inductive Load (C Curve) having 10KA breaking capacity &
133 confirms to IS :8828 in existing box having following capacity no 3.00 616.10
6 to 32A FP MCB
providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of 25 KA. at
415 V,having normal current rating up to 25 A to 100A. with
Fixed thermal & magnetic release suitable to work on A.C.
supply 50 c/s. with all internal connections & complete
erected in existing 16 G.M.S. housing.
ICS=100% of ICU only
Approved make four pole moulded case circuit breaker
having breaking Capacity ICU of 35KA. At 415 V, having
normal current rating up to 125A. With fixed thermal &
magnetic release suitable to work on A.C. supply 50 c/s. with
all iternal connections & complete erected in existing
G.M.S. housing.
ICS= 100% of ICU only.
Approved make four pole moulded case circuit breaker
having breaking Capacity ICU of 35KA. At 415 V, having
normal current rating up to 200A. With fixed thermal &
magnetic release suitable to work on A.C. supply 50 c/s. with
all iternal connections & complete erected in existing
G.M.S. housing.
ICS= 100% of ICU only.
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Supplying & erecting approved make Digital time switch
having lithium cell 6 years operative and operate battery
backup 1 channel day clock with 14 memory programme,
suitable to operate on 240V + 5%, 16A with, floating contacts
Minimum switching setup time 1 minimum & LCD display.
Also comprised permanent ON/OFF switching. Programming
switches & housed in fire proof thermoplastic enclosure &
transparent cover erected as required with necessary
connection erected as directed.t
25 Amp DP Dinrail Mounted Contactor Equivalent to Legrand
make Cat. No. 4125
SITC of 40 Amp DP Dinrail Mounted Contactor Legrand make
142 SITC of IP65 Polycarbonate enclosure for DP MCB no 5.00 1,380.67
143 SITC of IP65 Polycarbonate enclosure for FP MCB no 21.00 1,464.50
144 SITC of IP65 Polycarbonate enclosure for FP MCCB no 1.00 3,134.03
SITC Of 32A x 250 Volt single phase Power socket outlet point
145 having IP rating of IP:65 at convenient location with MCB.for no 2.00 6,331.69
SITC Of 32A x 415 Volt three phase Power socket outlet point
146 having IP rating of IP:65 at convenient location with MCB.for no 2.00 6,598.33
Making trench in soft soil of suitable width of 90 cms deep for
laying cable or locating the fault all over the run and
backfilling the same and making the surface proper. Providing
147 and erecting iron clad cable route marker duly marked with mt 10.00 54.54
ELE.CABLE of size 23 cms.X 12 cms. Flushed with ground in
cement foundation as directed by Engineer in charge. The
width shall be as per requirement
Covering of cable with second class bricks laid cover the cable
crosswise & also on both sides with covering of 7. 5 Cms.
layer of sand above & below cable (cable shall be laid in
148 0.9mtr.deep & 0.4 Mtr.wide trench). Where there are more rmt 10.00 157.56
than one cable in the trench on either side of the cable,
Cms. over lapping of bricks shall be provided.
Providing cement concrete.for foundation or for concrete
filling in 1:2:4 ratio with 20 to 25 mm stone metal duly
plastered with necessary curing for pole muffing or any other
Providing burnt brick masonry with 1:6 cement concrete duly
plastered including watering, stacking joint on exposed faces,
150 rocking at joints on exposed faces and watering complete Cu.mtr 2.00 4,494.50
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Construction of brick masonry pulling chamber 450 mm x
450 mm inside clear size and depth up to 0.6 meter with
mm thick masonry in cement mortar proportion 1:5,cement
finish cement plaster in CM proportion of 15 mm thickness
from inside with 150 mm thick PCC at bottom with top slab
minimum 200 mm thickness in M20 grade with
reinforcement. The rate shall be inclusive of providing and
fixing frame and 450 mm dia cover of FRC for the Heavy Duty.
Rate also inclusive of excavation and back filling & clearing
the site by removing debris & Shifting of the debris & making
site good As per the Instruction of the Engineer In charge
complete in all respect.
Construction of brick masonry pulling chamber 600 mm x
600 mm inside clear size and depth up to 0.60 meter with
mm thick masonry in cement mortar proportion 1:5,cement
finish cement plaster in CM proportion of 15 mm thickness
from inside with 150 mm thick PCC at bottom with top slab
minimum 200 mm thickness in M20 grade with
reinforcement. The rate shall be inclusive of providing and
fixing frame and 600 mm dia cover of FRC for the Heavy Duty.
Rate also inclusive of excavation and back filling & clearing
the site by removing debris & Shifting of the debris & making
site good As per the Instruction of the Engineer In charge
complete in all respect.
Construction of brick masonry pulling chamber 750 mm x
750 mm inside clear size and depth up to 0.75 meter with
mm thick masonry in cement mortar proportion 1:5,cement
finish cement plaster in CM proportion of 15 mm thickness
from inside with 150 mm thick PCC at bottom with top slab
minimum 200 mm thickness in M20 grade with
reinforcement. The rate shall be inclusive of providing and
fixing frame and 750 mm dia cover of FRC for the Heavy Duty.
Rate also inclusive of excavation and back filling & clearing
the site by removing debris & Shifting of the debris & making
site good As per the Instruction of the Engineer In charge
complete in all respect.
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Supplying , fabricating and installation of various sizes MS
race way / junction boxes/clamps/hangers for Cable Tray,
Light Fixture made out of specified size sheet/Angle/Flat/rod/
channel etc as per design with all necessary accessories like
bend, junction boxes, coupler, Anchor fastener, Bolt Nuts,
etc.. & work from MS structure for other work with anchor
fastener of Hilti make and necessary hardware with necessary
welding has to be done to complete the job from ISA / ISMC /
PLATE. The job also includes to paint the structure with two
coats of red oxide and two coats color of enamel paint as
approved and recommended by consultant. Complete in all
respect to be installed at any height with all necessary
arrangements. Contractor has to complete the work up to
satisfaction of Consultant
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable
multistrand Aluminium conductor for 1.1 KV. to be laid on
wall with necessary clamps or in existing trench / pipe of
following size of cables
70 sq.mm x 3.5c Al. XLPE Arm. Cable
156 50 sq.mm x 3.5c Al. XLPE Arm. Cable mt 30.00 289.87
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable
multistrand Copper conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe at road
157 crossing or floor of following size of cables. mt 50.00 723.16
(C) 4 core 10 Sq. mm
158 6 sq.mm x 4 c Cu. XLPE Arm. Cable mt 75.00 544.39
159 6 sq.mm x 3 c Cu. XLPE Arm. Cable mt 200.00 422.18
Providing & erecting XLPE(IS:7098) (I)-88 ISI armoured cable
multistrand copper conductor for 1.1 KV. To be laid on wall
with necessary clamps or in existing trench / pipe at road
crossing or floor of following size cable.
4 sq.mm x 3 c cu. XLPE Arm. Cable
Supplying & erecting XLPE (IS:7098)(I)-88 ISI unarmoured
copper cable 1.1 KV grade to be erected as directed of
3 core 2.5 Sq.mm.
SITC of 10 Core X 4sq.mm. Cu. multicore Unarmoured cable
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Cable Termination
SITC of Cable end termination of the following XLPE insulated
PVC sheathed aluminum/copper conductor armored cables of
1100 volt grade including supplying and fixing of bimetallic
Long neck crimping lugs, double compression type Brass
glands with earthing.
70 sq.mm x 3.5c Al. XLPE Arm. Cable
164 50 sq.mm x 3.5c Al. XLPE Arm. Cable no 2.00 156.55
165 10 sq.mm x 4 c Al. XLPE Arm. Cable no 4.00 88.88
166 6 sq.mm x 4 c Al. XLPE Arm. Cable no 38.00 60.60
167 6 sq.mm x 3 c Al. XLPE Arm. Cable no 6.00 55.55
168 4 sq.mm x 3 c Al. XLPE Arm. Cable no 20.00 55.55
Supplying & erecting XLPE (IS:7098)(I)-88 ISI unarmoured
copper cable 1.1 KV grade to be erected as directed of
3 core 2.5 Sq.mm.
MV Switchgear & Power Panels
Panel should be made in 2 Sections as oer substation layout,
The cost of connection between both the section of panel is
included in the price of this panel. Nothing extra shall be paid
Supply, Unloading at site, shifting to site, assembling, leveling,
grouting, erecting, Testing, & Commissioning main L.T. panel
board, fabricated from M.S. sheet & folded channel totally
enclosed cubical type compartmentalized. Scope Covers
Unloading at Site, Store in Weather Proof Condition, Shift to
the Location Basement / GF / FF, Grouting, Installation,
Testing & Commissioning complete in all respect & As per the
instruction of Architect / Consultant / Engineer Incharge.
Scope also covers Co ordination with Panel Manufacturer.
Design, fabrication, assembling, supply, installation , testing
of Panels for 415 V, 3 phase, 50 Hz, 4 wire power supply
Panels shall be fabricated out of 2 mm thick CRCA sheet steel
in cubical formation, compartmentalized in Form 4b
Construction, floor mounted, free standing and shall be dust
and vermin proof. 3 mm thick cable gland plate, shall be
provided both at the top and the bottom of the panel.
All large panels shall be provided with lifting hooks.
Distribution panels shall be fabricated in accordance with the
specifications.
Note : Panel vendor has to provide Surge Protection at every
stage of the Distribution.
1) Supporting rigid steel framework.
2) Cubicle type, 14 gauge CRCA sheet steel enclosed.
3) Complete with interconnections and distribution bus bars.
4) Proper bonding to earth.
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
5) Painting/lettering on Breakers and distribution boards,
the location they serve, providing on each panel its circuit
6) Providing cable clamps / supports within distribution
boards cable alley.
7) TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s
with adequate size of neutral link.
8) All MCB’s shall be of minimum 10 KA breaking capacity.
9) The breaking capacity of MCCB’s are mentioned panel
10) All motor feeders MCCBs shall be of motor duty.
11) Distribution panels shall be Powder Coated with Siemens
gray paint shade no. RAL-7032 of IS-5.
12) Degree of protection for following type of distribution
panel enclosure shall be as per IS:13947-1993.
a) IP 52 for indoor panels.
b) IP 54 for kitchen and laundry panels.
c) IP 55 for outdoor panels.
13) All MCCB’s shall be provided with operating
mechanism for door interlock & with the roraty handle.
14) Current density of aluminium shall be 1 sq mm for
amps for rated current of bus bars and current density of
copper shall be 1 sq.mm for 1 amps for rated current of bus
15) Tinned copper earth bus as specified in the BOQ / SLD
shall be provided through out the length of each board.
16) All measuring instruments (Meters) shall be of digital
electronic with LED of approved make and compatible with
17) All hinged door shall be earthed through 2.5 sq mm
tinned braided copper wire.
18) All panels shall have provision of the following:
a) IP 55 for outdoor panels.
b) Pad locking of MCCB’s handles in “OFF” Position.
19) Additional set of C.T.s, potential free contacts,
connectors, contactors with wiring etc are to be provided for
BAS including space required for various transducers in Main
Switch Board sections. Only transducers shall be supplied by
BAS contractor.
20) All the C.T.s should be auto short link type.
21) All the MCCB's should be with rotary handle.
22) All MCB’s used for protection of resistive and lightly
inductive load shall be type “B” characteristic and inductive
(motor) load shall be of type “C” characteristic and discharge
lamps and UPS etc. shall be of type D characteristic.
23) All incoming and outgoing air circuit breakers shall be
placed on middle portion of the vertical in single tier
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
24) All PTs / control transformer shall be provided with centre
tap earth secondary.
25) If Any descripancy found in SLD & BOQ, it should be
brought in the notice of the Client / Consultant, Client /
Consultant's decision will be final in case of any descripancy.
26) G.A. Drawing should be checked & Finalised by consultant
before fabrication.
Incoming : From Supply Co. Meter
160 amps FP MCCB (16 KA) with following accessories: 1 Sets
i. LED type Phase indicating & ON, OFF light shall be protected
by 2 amps SP MCB's. - 5 nos.
ii. 3 Nos. of Digital type 0-160 / 5 amps CTR digital ammeter
with 3 nos 160 / 5 amps, 15 VA Class I CT’s.
iii. Digital type 0-500 Volt digital voltmeter with inbuilt
selector switch & shall be protected by 2 amp TP MCB’s -
iv) Load Manager of Schneider make PM 5110 with RS
connectivity with 3 nos. of Class 1, 160 / 5 Amp. CT of 15 VA
Incoming : From D.G.
160 amps FP MCCB (16 KA) with following accessories: 1 Sets
i. LED type Phase indicating & ON, OFF light shall be protected
by 2 amps SP MCB's. - 5 nos.
ii. 3 Nos. of Digital type 0-160 / 5 amps CTR digital ammeter
with 3 nos 160 / 5 amps, 15 VA Class I CT’s.
iii. Digital type 0-500 Volt digital voltmeter with inbuilt
selector switch & shall be protected by 2 amp TP MCB’s -
iv) Load Manager of Schneider make PM 5110 with RS
connectivity with 3 nos. of Class 1, 160 / 5 Amp. CT of 15 VA
160 amps FP Tinned copper bus bars with colored heat
shrinkable insulated sleeve.
63 amps 4 pole MCB ( 10 KA ) : 9 Nos.
40 amps 4 pole MCB ( 10 KA ) : 10 Nos.
6-32 amps 4 pole MCB ( 10 KA ) : 17 Nos.
6-32 amps 2 pole MCB ( 10 KA ) : 4 Nos.
32 amps 4 pole Contactor : 8 Nos.
Astronomical Digital Time Switch : 4 Nos.
Panel should be as per SLD & Specifications
SITC of 6W LED Uplighter for Pillar's of 3000K, with inbuilt led
driver, IP65, IK08, and all kind of accessories Of Cat. No.
GRAZIA-PIGMY 6W
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
SITC of 20W LED Uplighter for Ghumbaj of 3000K, with inbuilt
172 led driver, IP65, IK08, and all kind of accessories Of Cat. No. no 70.00 3,605.70
AERO FLOOD QUBIK20W3K
SITC of 7W LED Uplighter for Jali of 3000K, with inbuilt led
173 driver, IP65, IK08, and all kind of accessories Of Cat. No. no 20.00 4,767.20
LENEA-LED 7W 3K
174 SITC of LED Driver DRIVER 200W IP67 no 147.00 5,928.70
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion resistance with
diffuser with company mark/name
120 to 300 V,Power Factor more than 0.9, THD < 10 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED efficiency-110
175 LED driver efficiency > 85 % no 4.00 254.52
CREE / OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/Bridgelux
make LED used for luminaire. ( fitting required LM-79 & LM-
80 Certificates)(NOTE: Below description have shown ranges
of Wattage capacity of LED fittings.The Engineer incharge may
select any wattage capacity between the ranges shown.)
(A) Tube Light with integral driver
(a) 5-9 Watts, Surge-2 KV, IP-20,2 feet, Cat-lll
(d) 22-24 Watts, Surge - 2KV,IP-20,
Supplying & erecting approved make low noise decorative
177 exhaust fan having size 200mm with 1350 RPM with square no 7.00 2,009.90
frame ABS body with inbuilt lowers & square frame.
Supplying & erecting single phase approved make industrial
exhaust fan suitable for medium duty ring mounted low noise
operation suitable for medium duty having following dia size
and maximum speed in RPM
[A] 305 mm dia 900 RPM
Providing & erecting Approved make Power Saving 50 Watt
Ceiling Fan with double ball bearing ISI mark with Condenser
230 volt A.C. 50 Hz 1200 mm sweep complete having
179 3blades with aluminium blades with , canopy & 30 cms. down no 14.00 2,090.70
rod erected with 24/ 0.2, 3 core flexible wire with
earthing.(Make shall be approved by Engineer in charge)
Supplying and erecting 19 / 20 mm. nominal bore Medium
Class M.S. Pipe down rod erected duly painted for fan
complete with necessary 24/ O.20, 3 core flexible wire with
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Supplying & erecting funnel type earthing having earth plate
of following size burred in specifically prepared earth pit
mtr. below ground with 40 kg. charcoal and salt with
alternate layers of charcoal & salt, 20mm.dia. G.I. pipe with
Funnel with a wire mesh for watering & bricks masonry block,
C.I. Cover complete as per para 7.3 of IS 3043 with necessary
length of double Galvanised Iron / copper earth wire No
SWG bolted with lug to the plate and covered in 12 mm dia.
G.I. pipe 2.5 mtr long complete connected to the nearest
switch gear with end socket as per direction & duly tested by
earth tester confirming to IS (As per drawing) with following
with 60 x 60x 0.315 cms. Copper earth Plate
Supplying & erecting in earthpit of minimum bore dia. 225mm
size ASH or approved make Safe Earthing Electrode consisting
Pipe-in-Pipe Technology as per IS 3043-1987 made of
corrosion free G.I.Pipes having Outer pipe dia of 80 mm
having 80-200 Micron galvanising, Inner pipe dia of 40 mm
having 200-250 Micron galvanising, connection terminal dia
of 14 mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation suitable
for following type of applications.
For Electrical Installation covering Transformer Neutrals,
Lightning arrester Earthing, A.C.Plant & Sensitive
Computer System(like Automation, SCADA)i.e.
independent Earthing located in other than normal soil i.e.
Soft Rock, Marshy Soil etc.. -Length of Pipe : 3 Mtrs.
-Back filling Compound :2 nos Bags of 25 Kg.
Earth wire/strips :
Supply and laying cu. earthing strips for interconnecting the
earthing stations, panels, DB's etc. in built up trenches, on
walls/ceiling, buried in ground generally as specified and
shown on drawings complete with : fixing accessories
183 Corrosion protection of buried conductors with bituminous kg 350.00 90.90
coating and covered with PVC tapes.
Providing and erecting HOT deep Galvanised iron strip / wire
Supply and laying cu. earthing strips for interconnecting the
earthing stations, panels, DB's etc. in built up trenches, on
walls/ceiling, buried in ground generally as specified and
shown on drawings complete with : fixing accessories
Corrosion protection of buried conductors with bituminous
coating and covered with PVC tapes and with all type of
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant PVC
insulated conforms to IS 694, IEC - 227 erected in existing pipe
of following size (Specifically for control panel, relays, power
185 switchgears, motor starters & control wiring) with required mtr 15.00 55.55
size of copper lugs, nuts and bolts if required.
Supplying and Laying mains with 1 no. of 6 sq mm Cu. PVC
insulated FRLS flexible wire ( Green Color Only )
SITC of Water Tight Junction Box of Hensel make Cat. No.
KG9003IN With necessary clamp for mounting of the J.B. ( All
the cable / wire connections to the JB shall be with the Water
tight Glands only )
Supplying & erecting carbon dioxide (CO2) fire extinguisher
user of following capacity with necessary clamps made from
50 x 6 mm M.S. Flat with nut & bolts grouted in wall
For 4.5 Kg Capacity
Supplying rubber matting of following thickness as per IS
Providing and erecting metallic vitrified danger notice board
189 for MEDIUM VOLTAGE installation to be erected as per IS. no 10.00 80.80
Providing printed instruction chart both in English and
190 Gujarati and duly framed with front glasses, for treatment of no 1.00 151.50
person suffering from Electric shock
Providing the A0 Color size print of the Final Plan / SLD duly
191 framed out on Glass for Electrical room & BMS Room no 5.00 959.50
Providing the A1 Color size print of the Final Plan / SLD duly
192 framed out on Glass for Electrical room & BMS Room no 5.00 787.80
Providing the A2 Color size print of the Final Plan / SLD duly
193 framed out on Glass for Electrical room & BMS Room no 5.00 686.80
Providing the A3 Color size print of the Final Plan / SLD duly
194 framed out on Glass for Electrical room & BMS Room no 5.00 474.70
Providing & laying approved make Double walled corrugated
pipes (DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at
required depth for laying of cable. below ground / road
surface for enclosing cable and back filling the same to make
ground as per original.
I/We am/are willing to carry out the work at… % above/below percent (Should be written in figures and words) of the estimated rate
mentioned above. Amount of my /our tender works out as under.
Sr. No. Description of item Unit Quantity RATE Total Amount
Sr. No. Description of item Unit Quantity RATE Total Amount
Estimated amount put to tender Estimated amount put to tender
Deduct………% below Add………% Above
In words In words
1 The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge for which no
extra payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 GST and Income tax TDS will be deducted at a source while making payments of bills
4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017 Cement
Consumption/16/C, Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as per actual mix design the
cost of difference of cement consumption have been deducted from the rate of original item at the rate of input rate mentioned in all
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
02.SBD-Ramnath Temple.pdf
03-BOQ NOTES-Ramnath Temple.pdf
04-PQ Ramnath Mahadev Temple.pdf
05-Schedule-B.pdf
06 Technical Specification.pdf
07-AFFIDAVIT_SITE VISIT.pdf
08 Make List.pdf
09_GR to be attached with DTP_SBD_with Index.pdf
10_RB_Technical Specification_Electrical.pdf
11_RB_Technical Specification_Civil.pdf
RAMNATH MAHADEV ENTRANCE GATE PLAN SECTION ELEVATION.pdf
RAMNATH MAHADEV FLOORING TILE PLAN.pdf
RAMNATH MAHADEV GAZEBO PLAN SECTION ELEVATION.pdf
RAMNATH MAHADEV MAIN GATE PLAN.pdf
RAMNATH MAHADEV MASTERPLAN.pdf
RAMNATH MAHADEV PUJARI HOUSE PLANSECTION ELEVATION.pdf
RAMNATH MAHADEV SHOP PLANSECTION ELEVATION.pdf
RAMNATH MAHADEV YAGNASHALA PLAN SECTION ELEVATION.pdf
01. NIT-Ramnath Temple.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .