Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.5 L+₹3.1 L (13.2%)Rejected-AOC 37 SUBHASH NAGAR AIR FORCE JODHPUR 342 008 | JODHPUR | JODHPUR | RAJASTHAN | 342008 | L2 | Rejected-AOC L2 |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
11 Sept 2021, 6:00 pmClosed
GE (AF) NO 2 JODHPUR
GE (AF) NO 2 JODHPUR
PROVN OF ROOF TREAT., SHED, STAGE FOR WATERTANK AT P-390, PROVN OF SEWAGE DISPOSAL DRAIN BEHIND SUBROTO GUEST ROOM AT 32 WING OFFRS MESS, PROVN FOR OXYGEN PLANT INSTALLATION AND PROV OF GEYSERS IN CERTAIN SMQS OF SUBROTO ENCLAVE AT AF STN JODHPUR.
2021_MES_468852_1
8272/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) NO 2 JODHPUR
AS PER TENDER DOC
6 documents required · 6 mandatory
₹500
GE (AF) NO 2 JODHPUR
₹54,000
Yes
12 Oct 2021
17 Aug 2021
13 Sept 2021
17 Aug 2021
11 Sept 2021
28 Aug 2021
Amount
Cutting out cracks to V section in existing roof or terrace cleaning out wetting / grouting with cement and sand slurry 1:3 compolete all as specified and as directed by Engineer- in- charge.
M&L for10mm thick rendering in CM (1:3) over stone/concrete surfaces mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid seperately as supply only.
Supply only integral water proofing compound ISI marked.
M&L for preparing new surfaces and applying two coats of Polyurethene (PU) acrylic based water proofing liquid compound over one coat of diluated self priming with reinforcing fabric sheet as per manufacturer instruction to stop leakage/ seepage from roof / wall complete all as specified and as directedc by Engineer- in- charge (Note: Quoted rate shall deemed to be included for work in building /structure of any height.
Taking down steel tubing 15mm bore of pipe and connecting including away from site.
Supply and laying in repairs 15mm bore tubes galvanised steel medium grade with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Dismantling of asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings.
M&L for Pre painted galvalume aluminium zink coating GI based plain sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering / clading to wall fixed with self tapping screws as specified.
Excavation in post holes (or similar holes) each n. exc 0.5cum getting out returning and filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm.
M&L for Plain cement concrete Type D-2 (1:4:8) using 40mm graded stone agg as in foundation filling and mass concrete.
M&L for framed work such as grills, gratings etc with ends of bars shoulders, and/or revited or forged in to spikes, framed guard bars, barred iron doors ladders, framed balusters, walk ways, railings, framed work of water tanks and similar work conforming to Fe 290Gde E-165.
M&L for two coats of synthetic enamel paint on steel surfaces over one coat of primer.
M&L for rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces.
S&F post and struts in fencing includung cutting tops to shape as directed , drilling koles notching for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting, or reviting etc, and similar work confirming to Fe- 290 Gde E- 165 complete all as specified and directed.
Fixing only chain link fencing including line wire any mesh , size and type to any type of standard rails, straining bolts etc including provision of binding wire complete all as specified and directed.
Supply only chain link MS Galvanised fencing any size or type complete all as specified and directed.
S&F mild steel screw bolts (machine made ) with hexagonal or square heads (diametre of neck 5 to 10mm) at one end and screw the other or screwd both ends to be fitted with washers and one hexagonal or square nut n exc 5cm long.
Taking down old existing roof treatment (APP Membrane and Plaster ) and removing out side MOD and cleaning of roof slab / chajja sweeping with brooms removing all loose materials debris etc complete all as specified and as directed by Engineer-in- charge.
M&L for two coats of cement base paint on brick/ concrerte surfaces over one coat of primer.
Disconnecting existing tanks,(exc 250 ltr but not exceeding 500 ltr) setting a side (or lowering if required) for repairs cleaning etc, and hoisting if required reconnecting and refixing in position ( cleaning repairing, etc measured paid seperately.
Taking down cement plastrering on stone masonry walls including racking out joints hacking for key scrubbing down with wateretc,
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of 150mm dia
Supply and laying, jointing 150mm internal dia of salt glazed stoneware pipes grade 'A' incl testing and laid in trenches to a level on concrete bed complete all as specified.
M&L for cement concrete 1:3:6 type C-2 using 40mm graded stone aggregates incl packing under and haunching against the sides for 150mm internal dia SGSW pipes after they are laid and tested including demolition of old bed and pipes omplete all as specified and as directed. (thickness of concrete bed 100mm).
Demolition of pcc block or stone boulder masonary built in cement mortar incl all quoins, arches, pillars etc omplete all as specified and as directed.
M&L for pre-cast cement concrete 1:3:6 type C1 (using 20mm graded stone aggragate) in block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar, 1:6 complete
M&L for rendering 15mmthick in CM 1:4 on block masonry surfaces finished even and smooth without using extra cement complete all as specified.
M&L for cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in coping and similar work incl necessary form work to obtain a smooth finishes omplete all as specified and as directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregates as in foundation of manholes omplete all as specified and as directed.
M&L for PCC 1:2:4 type B1 using 20mm graded aggregates as in surfaces channels and drains complete all as specified.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement incl forms, moulds, mitred/stoped ends etc omplete all as specified and as directed.
M&L for precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, shelves and similar articles with plain faces, set in CM 1:4, including necessary form work moulds etc all as specified. (Reinforcement shall be measured and paid for separately).
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 150/200mm dia pipes omplete all as specified and as directed.
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in in any type of soil omplete all as specified and as directed.
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil omplete all as specified and as directed.
Removing excavated material not exceeding 50M and depositing where directed at a lavel not exceeding 1.5m above the starting point, soil omplete all as specified and as directed.
S&F salt glazed stoneware gully traps of size 150 x 150 mm, square or rounded mouthed, type `P' fixed in CM 1:6 and cover with RCC cover slab of size 200 X 200 X 50mm incl necessary exc, pcc etc.
Demolition of cement concrete in ground floor and pavings nexc 15 cm thickness (below or above ground level ) complete all as specified.
Material and labour for PCC (1:4:8) type D2, 100mm thick using 40mm graded stone aggregates as in sub base, finishing the top surface of concrete even and rough to receive topping layer complete all as specified and directed.
Material and labour for PCC (1:2:4) type B2, 100mm thick using 40mm graded stone aggregates as in hardstanding for open parking, finishing surface of concrete road, pavements, by brooming complete all as specified and directed.
M&L for pre polished chemically treated rubber moulded Chequered cement concrete coloured tiles of size 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors With white cement & pigment incl 20mm thick cement screed CM 1:6.
M&L for cement concrete 1:3:6 type C-1 ( 20mm gradede stone aggragate) in benching, steps;seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
Supply and fix Servo controller Oil cooled stabilizer for autokkmatic operation , three phase , naturally oil cooled indore type disigned for input varriation between 300V to 480V with output voltage stabilizer at 415V 50 KVA with accuracy all as specified and directed.
Supply, Laying , jointing and testing LT underground cable of 16 Sqmm 4 Core, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culve (Note: Excavation and GI Tubing earthwork shall be measured inclusive under respective item of Sch 'A'.) :-
Supply, Laying , jointing and testing LT underground cable of 70 Sqmm 3.5 Core heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culve (Note: Excavation and GI Tubing earthwork shall be measured inclusive under respective item of Sch 'A'.)
Supply,installation, testing and commissioning new LT feeder piller box " CPRI Approved" cubicle type,with angle & frame, free standing, floor mounted, outdoor, weather proof type, pedstal mounted feeder Pillar working on 440V 3-phase, 50 Hz, AC supply with and 4 Nos stepped aluminum bus bars for looping & branch connection system , weather proof, dust-proof and vermin proof with canopy on top, 3mm thick CRCA sheet steel enclosure, painted as per the 7-tank process and painted for outdoor, weather proof IP-55 protection installation, the bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust proof .bus bar chamber shall be provided with better ventilation facility in the form of louvers for better heat dissipation as per specification with and including the following components complete all as specified and as directed:- (a) Aluminium bus bar capacity 400 Amps for Phase R-Y-B & 200 for neutral -01 No (b) MCCB 4 Pole 36, KA , 250 Amps -01 No (Incomer) (c) MCCB 4 Pole , 36KA , 100 Apms -02 Nos (O/G) (d) MCCB 3 Pole , 25 KA , 63 Amps -03 Nos (O/G)
M&L for earthing GI Strip complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified and directed.Note: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
Supply and fix of electric water heater storage type, steel body with copper inner tank and heating element upto 2KW capacity 25 litres, BEE 5 star rated with complete accesories such as safety valve , thermostat, NRV, connection etc
M & L Point wiring complete with 1100 volts grade, single core, PVC insulated FRLSH cable with multy-stranded copper conductor of size 4 sqmm nominal area, drwan through and including rigid,non-metallic PVC conduit pipe of suitable size, with all necessary fittings on wall/ roof surfaces, duly earthed with one run of single core PVC insulated FRLSH cable with multy-stranded copper conductor of size 2.5 sqmm nominal area, as continuous earthing wire connected to common earth dolly including 1.6mm thick fabricated MS sheet/electroplated terminal box, for mounting switches/ switch socket combination/ fan regulators etc covered with 3mm thick hylam sheet complete for one 15 Amps switch socket out let point on indipendent board all as specified and as directed.
M & L Single pole and neutral enclosure with a two pin and earth plug and socket copmplete with one single pole 20 Amps MCB complete all as specified and as directed.
M & L Cutting in position and providing Tee 25x15mm screwing the existing GI tubing for addn/altns of size 25 mm dia complete all as specified and as directed.
S & F GI Tubes 15 mm dia, medium grade, galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
Supply & fix Bib taps 15 mm brass chormium plated with curtch or butterfly handle complete all as specified and as directed.
Supply & Fix Valve stop screwed supplied and installed complete for size 15 mm dia. complete all as specified and as directed.
Supply & Fix PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
DEV INDUSTRIES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .