Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted bidder. | |
| 2 | L2₹33.9 L+₹18,077 (0.54%)Rejected-Finance SHOP NO 10 ASHRAM MANDIR NAKATIA P O P A C SHAHJAHANPUR ROAD BAREILLY 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L2 | Rejected-Finance Higher quoted bidder. | |
| 3 | L3₹36.2 L+₹2.5 L (7.43%)Rejected-Finance 161 MISSION INTER COLLEGE ROAD VILL PITHORAGARH DISTRICT PITHORAGARH STATE UTTARAKHAND PIN 262501 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262501 | L3 | Rejected-Finance Higher quoted bidder. | |
| 4 | L4₹41.9 L+₹8.2 L (24.3%)Rejected-Finance 22 JANKALYAN SOCIETY NAVJIVAN AJWA ROAD BARODA 390 019 | BARODA | VADODARA | GUJARAT | 390019 | L4 | Rejected-Finance Higher quoted bidder. |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Jun 2022, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post Bharkatia Pithoragarh ( UK)PIN-262520
REP/REPLACEMENT OF SOLAR WATER HEATER, SUMMER/WINTER ELECTRIC APPLIANCES AND CONNECTED ITEMS OF WORKS AT MIL STN PITHORAGARH
2022_MES_525350_1
8469/PGH/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (MES) Pithoragarh
Class D, category b(i)
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹90,000
Yes
10 Sept 2022
21 May 2022
20 Jun 2022
21 May 2022
18 Jun 2022
4 Jun 2022
Amount
DESCRIPTION OF ITEMS
Taking down old u/s copper /Aluminium point wiring (Light fan socket or power) complete, removing materials from site and making good disturbed surface of walls, floors etc, complete all as specified and directed.
M&L for point wiring Surface type with 1.5 Sqmm, single core (FRLS), PVC insulated with multistranded unsheathed copper conductor cable including rigid non metallic PVC surface Caping casing /conduit 20 mm or higher dia, ISI marked complete with all PVC conduit accessories / fittings and sunk switch boxes with 3 mm thick plastic laminated hard glossy surface sheet (white) top cover, including continuous earth wire of PVC insulated, unsheathed, 1.5 Sqmm multistrand copper conductor (FRLS) connected to all fittings, sunken boxes and common earth and connected to earth dolly , screwed with screws, cup washers complete all as specified and directed for One light point/ fan/ exhaust fan point/bell point controlled by one, one way switch of 5/6 Amps complete all as specified & directed.
Ditto all as per item No 2 above but one socket outlet three pin 5 amps control by one switch on the same board.
Ditto all as per item No 2 above but one socket outlet three pin 5 amps control by one switch on independent board
Ditto all as per item No 2 above but One light point controlled by two, two way switch of 5/6 amps
Ditto all as per item No 2 above but One bell point controlled by one bell push switch of 5/6 Amps on same boad.
Ditto all as per item No 2 above but with 2.5 Sq mm cable (FRLS) for one 15 Amp socket outlet controlled by one switch on independent board and 2.5 Sqmm PVC insulated unsheathed multi stranded copper conductor cable as continuous earth wire complete.
M&L for point wiring Concealed type with 1.5 Sqmm, single core (FRLS), PVC insulated with multistranded unsheathed copper conductor cable including rigid non- metallic exhusting PVC concealed conduit 20 mm or higher dia, heavy grade ISI marked complete with all PVC conduit accessories / fittings and sunk switch boxes with 3 mm thick plastic laminated hard glossy surface sheet (white) top cover, including continuous earth wire of PVC insulated, unsheathed, 1.5 Sqmm multistrand copper conductor (FRLS) connected to all fittings, sunken boxes and common earth and connected to earth dolly ,screwed, cup washers complete all as specified and directed for One light point/ fan/ exhaust fan point/bell point controlled by one, one way switch of 5/6 Amps complete all as specified & directed.
Ditto all as per item No 8 above but one socket outlet three pin 5 amps control by one switch on the same board
Ditto all as per item No 8 above but one socket outlet three pin 5 amps control by one switch on independent board
Ditto all as per item No 8 above but One light point controlled by two, two way switch of 5/6 amps
Ditto all as per item No 8 above but One bell point point controlled by one bell push switch of 5/6 Amps on same board.
Ditto all as per item No 8 above but with 2.5 Sq mm cable (FRLS) for one 15 Amp socket outlet controlled by one switch on independent board and 2.5 Sqmm PVC insulated unsheathed multi stranded copper conductor cable as continuous earth wire complete.
S&f in repair Switch piano, flush type, white finish, 5/6 amps, single pole, one way complete all as specified and directed.
S&f in repair Socket outlet 5 pin, 5/6 amps and flush type, non shutters, non inter locking type, complete all as specified and directed.
S&f in repair Switch piano, flush type, white finish, 5/6 amps, single pole, two way complete all as specified and directed.
S&f in repair Switch piano flush type, white finish, 15/16 amps, single pole, one way, complete all as specified and directed.
S&f in repair Socket outlet 2 in 1, 5/6 pin, 5 and 15 amp flush type, complete all as specified and directed.
S&f in repair bell push AC SP 240 volts flush type 5/6 Amps, single pole one way complete as all specified and directed.
S&f in repair bell electric Ding Dong/ AC, SP 240 volts, complete as all specified and directed.
S&f in repair in repair modular Switch 6/10 amps, 230 volt , one module, one way complete all as specified and directed.
S&f in repair in repair modular Switch 16 amps, 230 volt , one module ,one way complete all as specified and directed.
S&f in repair white cover plate with frame modular type of 03 module complete all as specified and directed.
S&f in repair white cover plate with frame modular type of 08 module complete all as specified and directed.
S&f in repair white cover plate with frame modular type of 12 module complete all as specified and directed.
S&f in repair metal flush box modular type of 03 module complete all as specified and directed.
S&f in repair metal flush box modular type of 08 module complete all as specified and directed.
S&f in repair metal flush box modular type of 12 module complete all as specified and directed.
S&f in repair in repair modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
S&f in repair in repair modular Socket, 6A /16 A- 2/3 pin combined 2 module complete all as specified and directed.
S&f in repairing PVC Gang Box 5/15 A with SSC complete all as specified and directed.
S&F in repair Electronic fan regulator flush type,switch size Step type, 230 volts ISI marked complete all as specified and directed.
S&f in repair ceiling rose, surface bakelite, AC, 220/240 volts, 3 terminals, complete all as specified and directed.
S&f in repair lamp holder, insulated body with back plate suitable for batten /angular fittings & making connection etc complete all as specified and directed.
S&F in replacement of LED Bulb 9 watt, complete all as specified and directed.
S&f in repair of 1x20 watt LED security light fitting , pressure die-cast aluminium including fixing the same of GI pipe 25 mm dia bore light grade bracket, 1.5 mtr long including necessary cutting / bending /welding and fixed the same with two Nos FI clamps of 40x 4mm duly painted and suitable size of nut & bolts etc. and making electric connection with two core copper flexible wire of 0.50 Sqmm complete and including taking down old fitting all as specified and directed.
S&F in repair round surface mounting LED panel with luminaire 6/8W, with aluminum housing plastic diffuser complete including taking down old fitting all as specified and directed.
S&f in repair Decorative wall Light fixture made up of polycarbonate, suitable for retrofit LED 9 W (spiral B-22 Base) complete all as specified and directed.
S&F in repair recess mounting LED 2x2 luminaire 36W, slim ceiling light with extruded aluminium housing and milky diffuser complete and including taking down old fitting all as specified and directed.
S&F in repair LED bulk head 10 Watt with PDC aluminium housing and milky diffuser complete and including taking down old fitting all as specified and directed.
S&f in repair of LED Integrated Batten T5 box type surface mounted, 18/20 W prewired including electric electrical connection with PVC insulated twin twisted copper wire of size 0.75 Sqmm from ceiling rose to tube light fitting and including taking down old fitting complete all as specified and directed.
S&f in repair of LED Integrated Batten T5 box type surface mounted, 9/10 W prewired including electric electrical connection with PVC insulated twin twisted copper wire of size 0.75 Sqmm from ceiling rose to tube light fitting and including taking down old fitting complete all as specified and directed.
S&f in repair in replacement LED bollard for gardens lighting landscape luminaries and IP65 protection with pressure die cast powder coated housing with PC diffuser 8/10 W LED complete and including taking down old fitting all as specified and directed.
S&F in replacement of cone round post top lanternsLED fittings suitable for 25 watt LED fittings, prewired with fixing arrangement complete all as specified and directed.
M & L for taking out old earthing and providing earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick burieddirectly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 5 of MES schedule 1991 part – I connected to earthing test point including earth continuity conductor and loop earthing etc. as required 4 mm dia galvanized iron or steel wire including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thickin RCC 1:2:4 type B1 dully reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and GI protection pipe light grade 15 mm dia beyond 7.5 mtr from electrode to earth terminal point /main switch board and 20mm bore GI watering pipe medium grade etc. complete all as specified and directed.
M&l in repair for sub main wiring with 1100 volts grade PVC insulated and unsheathed cable with stranded copper conductor 2x4 Sqmm, of code Red for Phase,Black For Neutral & Green For Earth concealed in wall and drawn including PVC conduit along with 4 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.
M&l in repair for sub main wiring with 1100 volts grade PVC insulated and unsheathed cable with stranded copper conductor 2x6 Sqmm, of code Red for Phase,Black For Neutral & Green For Earth concealed in wall and drawn including PVC conduit along with 6 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.
M&L in replacement of Vertical type TPN DB, 4 Way, as per IS-8623, IP-42 protection, universal mounting with 100A copper bus bar with neutral bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for MCCB 125 Amps TPN as incomer and MCB TP as outgoing, with and including providing following MCCB/MCBs & making necessary electrical connection for incoming & outgoing cables, with copper lugs, crimped with crimping tool :-a) Incoming:- MCCB, TPN, 415 Volts,125 Amp ultimate breaking capacity (lcu)-25 KA, confirm to IEC-60947-2-01 No (b) Out going MCBs:- MCB TP 415 volts 63 Amps having rupturingcapacity 10 kA, 'C' curve type-4 Nos
S&f in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with onesingle pole MCB of 20 amp including taking down all as specified and directed.
S&f in repair of MCB DB sheet metal enclosure for DB, TPN, 4 way having protection with 200 amps rated bus bar, 440 volts, double door, including grouting suitable for housing MCB's and isolators, including taking down complete all as specified and directed.
S&f in repair of MCB DB sheet metal enclosure for DB, SPN, 8 way having protection with 200 amps rated bus bar, 440 volts, double door, including grouting suitable for housing MCB's and isolators, complete all as specified and directed.
S&f in repair MCB DB sheet metal enclosure for DB, SPN, 4 way having protection with 200 amps rated bus bar, 440 volts, double door, including grouting suitable for housing MCB's and isolators, complete including taking down all as specified and directed.
S&f in repair MCB single pole, 240 volts, 6-32 Amps of 10 KA complete all as specified and directed.
S&f in repair MCB single pole & Neutral 240 volts, 6-32 amps, of 10 KA complete all as specified and directed.
S&f in repair MCB Triple pole & Neutral 240 volts,40 to 63 amps, of 10 KA 'C'curve
S&f in repair MCB Triple pole & Neutral 240 volts, 100 amps, of 10 KA.
S&f in repair MCCB, 3 pole, 415 volts, 100 amps, of 16 KA.
S&f in repair MCCB, 3 pole, 415 volts, 125 amps, of 16 KA.
S&f in repair MCCB, 3 pole, 415 volts, 200 amps, of 16 KA.
Supply & fixing in repair of 1100 volts grade heavy duty cable with PVC insulated aluminiuum conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire one twin core 10sq mm solid conductor.
Supply and laying in repair XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 4 core x 16 Sqmm including laying, testing and commissioning complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil for foundation of poles, structures, stay rods, laying of underground cable etc complete all as directed by Engr-in-Charge.
Returning, filling in soils including spreading, leveling, watering and well ramming in layers each not exceeding 25cm thick complete all as directed by Engr-in-Charge.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as directed by Engr-in-Charge.
M & L for sand cushioning with dry and clean sand over and under the under ground cable in trenches , ducts for cable protection includinglevellingand consolidationcomplete all as specified and directed by EIC.
M&L in repair for laying well burnt bricks,as in protection of cable laid dry, flat abutting each other wide wise all as directed by Engineer-in-Charge.
M & L in replacement for GI tubing 40 mm dia light grade for cable protection complete all as specified and directed.
M & L in repair of PVC/ metallicexhaust fan AC single phase 230/240V of size 250/300 mm sweep with rewinding super enameled copper winding wire of suitable size and proving with suitable insulation including replacementof wornout nut bolt washer blade split pin etc reassembling and testing on completion and refix in position complete all as specified and directed
Taking down carefully storage water heater of capacity 25 to 50 ltr, dismantling inner tank & outer tank, pipe assembly, cleaning thoroughly with descaling liquid compound, overhauling complete to ensure free & consistent flow of water through pipe outlet, bronze welding of inner tank if required at site, rethreading of inlet/outlet pipe 15mm dia, reassembling the same at existing/new place, testing/commissioning after re-installation at site complete all as specified & directed. Note:-The defective parts shell be measuredand paid in relevantitems separatelyin itemno-3 .
M&L for painting on external surface with one coat of white synthetic enamel paint after filling cavities with filler, incl writing MES No in front side of outer surface of geyser in sign writing with black colour to storage water heater (Geyser) complete all as specified and directed.
Supply only the following parts for geysers 50/25/35 Ltrs capacity of make Bajaj / Racold / Power pack/ Venus or equivalent ISI marked (Make of parts shall be as per make of Geysers) :-
(a) Supply only Heating element 2 KW suitable for operation on 230V AC 50Hz
(b) Supply only Heating element 1.5KW suitable for operation on 230V AC 50Hz
(c) Supply only Thermostat fitting fitment varying capacityfor 25/35/50 Ltrs capacity Geyser.
(d) Welding / brazing of copper tank for arresting leakages etc for 25/35/50 Ltrs capacity geysers
(e)Supply only release valve Make : Ditz/Venus/Usha /Recold/Bajaj.
(g)Supply only PVC connection 15 mm size with brass nut couplingin both end of length 450 mm for geyser Make : Prayag
( h) Supply only new apparatusplate complete with nuts, bolts, washers, rubber gasket so as to make it leak proof complete 25/35 ltr capacity and all as specified and directed.
(i) Supply only new apparatusplate complete with nuts, bolts, washers, rubber gasket so as to make it leak proof complete 50 ltr capacity and all as specified and directed.
(j) Supply only insulating material of glass wool for storage type water heater (geyser)any make and size 25 to 50 ltr capacity complete
(k)Supply only neon lamp indicator square/round type for storage type water heater of any capacity all as specified.
(l) Supply only rubber gasket of apparatusplate assy of storage water heater and S&F new rubber gasket suitable for 25/35/50 ltrs capacity storage water heater, complete all as specified and directed.
S&F in repair steel water tubing galvanized medium grade complete with all fittings like union, socket, nipple etc fixed to walls, ceiling or floor etc of size 15mm bore complete all as directed.
S&F in repair stop cock 15mm dia chromium plated screwed down screwed for iron pipe or for brass ferrule all as specified.
S&F in replacement industrial plug top, 3 pin (2 pin & earth) suitable for sheet metal plug & socket 16/20 Amps, 240 volts all as specified.
S&F in repair socket 3 pin industrial type 3 pin (2 pin & earth) suitable for sheet metal plug & socket 16/20 Amps, 240 volts all as specified.
Taking down existing unserviceable MCB single pole of any capacity from sheet metal enclosure and S&F new MCB single pole, 6-32 Amp, complete all as specified and directed.
M & L Flushing the complete condensing unit of AC refrigerator and dep freezer, evaporatorjointing and the compressor suction and delivery and search out leakage and rectify by means of brazing. and delivery tubes and replacement the charging lines. Strainers capillary tube etc rectification of the leakage from the system vaccuming dehydrating oil including testing and commissioning of system complete all as specified and directed.
S&F in repair of condensing unit and housing the unit of any make of the window type AC.
Supply & charging refrigerant gas R-134(a) suitable for environmentfriendly charging line on sealed unit of compressor of window type room AC 1.5/2.0 ton including crimping and resoldring to charging line, complete all as specified and directed.
Removing the unserviceable compressor unit from the window type room AC 1.5 ton and S&f in repair new hermetically sealed compressor unit, Make : Kirloskar/Shriram suitable to operate in AC single phase 50 HZ 230 Volts suitable for window type AC 1.5 ton and all as specified and all as directed by Engineer-in-Charge.
Removing the unserviceable compressor unit from the window type room AC 2.0 ton and S&f in repair new hermetically sealed compressor unit, Make : Kirloskar/Shriram suitable to operate in AC single phase 50 HZ 230 Volts suitable for window type AC 2.0 ton and all as specified and all as directed by Engineer-in-Charge.
S&f in repair PCB for the 1.5 to 2.0 ton capacity A/C of any make .
S&f in repair Evaporator coil for the 1.5 to 2.0 ton capacity A/C of any make .
S&f in repair Front grill for the 1.5 to 2.0 ton capacity A/C conditioners of any make of AC.
S&f in repair Starting relay for the 1.5 to 2.0 ton capacity A/C conditioners of any make and any type of AC.
S&f in repair Starting capacitor 80-100 mfd for the 1.5 to 2.0 ton capacity A/C conditioners of any make of AC. Make:Keltron
S&f in repair Running capacitor 36 mfd for the 1.5 to 2.0 ton capacity A/C conditioners of any make of AC. Make:Keltron
Supply only Compressor mounting rubber bush (set of 3 Nos counted as one unit)
S&F repair blower fan motor for split unit AC 1.5 ton to 2.0 ton (As per sample) incl taking down fan motor complete all as specified.
S&F repair condenser Fan blade rings 1.5 to 2.0 ton (As per sample) incl taking down old blower complete all as specified.
Taking down unserviceable copper tube from window type AC 1.5 ton to 2.0 ton supply & joint new copper tube for charging refrigerant gas in machine complete all as specified and directed.
S&F repair thermostat unit including electronic relay eqpt and electronic plate for air conditioner incl taking down old thermostat complete all as specified and directed.
Disconnecting of unserviceable three core flexible cord from window type AC/Refrigerator/storage water heater / voltage stabilizers of any size, supply and S&f in repair connect three core flexible cored of size 2.5 sq complete all as specified and directed
Cutting suction and discharge gas pipe line and taking out unsv compressor unit from refrigerator of 165/180 ltrs capacity and S&F new sealed compressor unit of same model or approved model of same capacity complete incl commissioning and testing after installation at site complete all as specified and directed.
Ditto all as per item No 105 above but refrigerator of capacity 210/310/320 ltrs
S&F in repair of cooling coil and housing of the refrigeratorunit of any make.( 280 ltr to 310 ltr)
S&F relay for refrigerator including taking down old relay complete all as specified.
S&F thermostat unit for refrigerator including taking down old thermostat complete all as specified.
S&F pigmy lamp pin/thread type 15 watts 230 volts suitable for refrigerator incl removing old bulb/lamp, complete all as specified and directed.
S&F door gasket for refrigerator (as per sample) incl taking down old door gasket & aligning door after opening from body incl inserting packing, welding, threading etc which so ever required to leave no air gap between door & body and top edge of refrigerator flushing with top surface of refrigerator of capacity 165/175 ltrs.
Ditto all as per item No. 111 above but for refrigerator of capacity 280/286/310 or 320 ltrs capacity.
Taking out unserviceable lock from the refrigerator and S&F new lock with keys, complete all as specified and directed.
Dismantling unserviceable freezer defrosting fan from double door refrigerator and replaced with new freezer defrosting fan of same model/capacity 200 to 300ltr ,complete all as specified and directed
M & L for replacement of unserviceable/damage freezer cooling coil assembly complete of existing model of refrigerator 165/175 ltrs capacity all as directed
Ditto all as per item No 115 above but refrigerator of 280/310/320 ltrs
Taking down unserviceable copper tube from any capacity of Refrigerator, supply & joint new copper tube for charging refrigerant gas in machine complete all as specified and directed.
Supply & charging refrigerant gas R-134(a) charging line on sealed unit of compressor of refrigerator 165/175 LTRS16including crimping and resoldring to charging line, complete all as specified and directed.
Ditto all as per item No. 118 above but280/310/320 ltrs R-134(a) non CFC refrigerant gas complete all as specified and directed
Taking down unserviceable capillary from any capacity of Refrigerator, supply & joint new capillary for charging refrigerant gas in machine complete all as specified and directed.
Taking down old unserviceable liquid filter/drier from all capacity of Refrigerator, Supply & joint new liquid filter/drier for charging refrigerant gas in machine complete all as specified and directed.
Taking down old unserviceable ceiling/exhaust/wall mounted/cabin/table fan for rewinding with super enameled copper winding wire of suitable size and providing with suitable insulation to fan including replacement of wornout nut, bolt, washers, split pin etc, reassembling and testing on completion complete all as specified and directed for Ceiling fan of any Make 1200 mm to 1400 mm sweep.
Ditto all as per Item No 122 above but Exhaust fan of any Make 300 mm sweep.
Ditto all as per Item No 122 above but Exhaust fan of any Make 450/380 mm sweep.
Ditto all as per Item No 122 above but Cabin fan/wall fan/table fan/pedestal fan 400 mm sweep.
Supply only Ball bearing of suitable size for ceiling fan/Exhaust fan of any size and sweep of fan in replacement of unserviceable ball bearing complete all as specified and directed.
Supply only capacitor 2.5 mfd , ± 5%, 440V, AC, 50 Hz after removing old/defective capacitor complete all as specified an directed.
Supply only MS Clamps with nut bolts and washers for hanging of ceiling fan of any size.
Supply only bush bearing for ceiling fan after taking out old dry/damaged bush bearing complete all as specified & directed.
Disconnecting / taking down carefully ceiling fan of 1200/1400mm sweep from existing position, dismantling, overhauling & cleaning thoroughly, oiling greasing and rehanging after replacing, split pins, check nuts, rubber reel etc and reassembling duly connected with new PVC 3 core flexible copper conductor cable of size 23/.0076 complete testing & specified all as directed.
Disconnecting / taking down carefully exhaust fan from existing position, dismantling, overhauling & cleaning thoroughly, oiling greasing and rehanging after replacing, split pins, check nuts, rubber reel etc and reassembling duly connected with new PVC 3 core flexible copper conductor cable of exhaust fan 450 mm sweep complete all as directed
Ditto all as per item No 131 above but exhaust fan 380/300 mm sweep
Ditto all as per item No 131 above but exhaust fan 250/225 mm sweep
S&F blade assembly suitable for exhaust fan 375/380 mm sweep including taking down old unserviceable blade assembly from exhaust fan, complete all as specified and directed.
S&F blade assembly suitable for exhaust fan 250/225 mm sweep including taking down old unserviceable blade assembly from exhaust fan, complete all as specified and directed.
S&F blade assembly suitable for exhaust fan 450 mm sweep including taking down old unserviceable blade assembly from exhaust fan, complete all as specified and directed.
M&L for painting with one coat of paint with grey enameled paint on external surface of exhaust fan of any size, including frame and louvers and writing MES NO. on outer surface of motor with black enamel synthetic paint complete all as specified and directed
Taking down burnt finned strip heater from winter heating plant of MH & S&F new finned strip heater of capacity 3.0 KW complete all as specified. Make-DASPASS
Ditto all as per item No 138 above but 2.0 KW.
Disconnecting, dismantling winter heating plant of capacity 38 KW (AHU capacity 4600 CFM) installed in OT/ICU of 161 MH for complete overhauling/servicing and refitting in same position after reassembling including replacement of minor repairs complete all as specified and directed by Engineer-in- Charge
Ditto all as per item No 140 above but winter heating plant of 10KW (AHU capacity 1400 CFM) installed in labor room of family ward, complete all as specified and directed by Engineer-in- Charge
Taking out worn out ‘V’ shape fan belt from blower assembly of winter heating plant of OT & labour room and S&F new fan belt of same size, complete all as specified and directed.
Taking down unserviceable heating element of any capacity from winter heating plant and replacing the same with new heating rod including commissioning and testing complete all as specified and directed.
S&F in repairs and connect 3 Phase contactor 32 Amp 415 V with 230 V coil complete all as specified and directed.
S&F in repairs and connect 3 Phase contactor 40 Amp 415 V with 230 V coil complete all as specified and directed.
S&F in repairs and connect 3 Phase contactor 63 Amp 415 V with 230 V coil complete all as specified and directed.
Taking out existing unserviceable voltmeter from winter heating plant control board and S&F new volt meter 0-500 volts of size 96mm x96mm including connecting and testing complete all as specified and directed.
Taking down unserviceable ball bearing from blower fan assembly of winter heating plant of 10KW & S&F new ball bearing of existing size complete all as specified and directed.
S&f in repair ball bearing of blower fan in existing winter heating plant of capacity 38 W all as specified and directed.
Repair of EPU of shadow less light fitting, checking & replacing defective parts in electronic printed circuit board, checking & repairing of auto control circuit complete including & testing & replacement of burnt damaged relay etc complete all as directed.
S&F in repair voltage stabilizer with input voltage 110 volts to 290 volts and output 230 voltage with 50 Hz,of capacity 4 KVA suitable for refrigerator / AC incl taking down old voltage stabilizer complete all as specified.
Repair of voltage stabilizer 0.5 /1.0 KVA automatic boost & buck type, checking & replacing burnt parts in electronic printed circuit board, checking & repairing of auto control circuit complete including calibration & testing & replacement of burnt damaged relay etc complete all as directed.
Repair of voltage stabilizer 3.0/4.0 KVA automatic boost & buck type, checking & replacing burnt parts in electronic printed circuit board, checking & repairing of auto control circuit complete including calibration & testing & replacement of burnt damaged relay etc complete all as directed.
Repair to voltage stabilizer 5.0 KVA by replacing worn out / burnt parts in electronic printed circuit, board, checking and repairing of automatic control circuit, replacement of damaged / burnt relay/transformer etc & calibrating the same complete all as specified and directed.
S&F time delay relay for voltage stabilizer 5 KVA (As per sample) including taking down old defective relay all as directed.
S&F time delay relay for voltage stabilizer 3 KVA / 4 KVA (As per sample) including taking down old defective relay all as directed.
S&f in repair of battery 12 V 80 AH of shadow less lamp at operation therater of 161 MH.
Checking of fault in Electric wiring of New accn area by deputing adequate number of qualified electrician and helper with necessary T&P and safety tools etc and ensure that to restore electricity after rectifying the fault with using minor items of cost not more than Rs. 10/- shall be included in the unit rate complete all as specified (complaint shall be part of the bill), replacement of electrical accessories, if reqd are measured and paid separatelyin relevant items: Note:- (a) The electrical items reqd to repair fault are measured and paid separatelyin relevant items. (b)The fault shall be attended within one day, otherwise recovery will be charged Rs. 50/- per complaint per day. (c) Electrician will take the complaint slip from JE EM and the same will be depositing to JE EM duly signed by Users after completing the job for making payments.
Checking of fault in Solar water Heater of New accn area by deputing adequate number of qualified Solar technician/Plumber and helper with necessary T&P and safety tools etc and ensure that to restore water heater in working condition after rectifying the fault with using minor items of cost not more than Rs. 10/- shall be included in the unit rate complete all as specified (complaint shall be part of the bill), replacement of connected accessories if reqd are measured and paid separatelyin relevant items: Note:- (a) The Solar water heater items reqd to repair fault are measured and paid separatelyin relevant items. (b)The fault shall be attended within one day, otherwise recovery will be charged Rs. 50/- per complaints per day. (c) Solar technician/Plumber will take the complaint slip from JE EM and the same will be depositing to JE EM duly signed by Users after completing the job for making payments.
Supply only Hot water tank SS 304 ex model cap100 Ltr with heat exchanger
Supply only Hot water tank SS 304 ex model cap 200 Ltr with heat exchanger
Supply only Heating element 2 KW
Supply only Heating element 3 KW
Supply only Thermostat for solar water heater 100/200 Ltr
Supply only EIS-DA (descaling chemical for all type metal) as complete
Supply only Toughened Glass for solar water heater 100/200 Ltr
Supply only Makeup tank for solar water heater 100/200 Ltr
Supply only NRV of makeup tank for solar water heater 100/200 Ltr
Supply only Elbow 15mm
Supply only Elbow 20mm
Supply only Elbow 25mm
Supply only Tee 15mm
Supply only Tee 20mm
Supply only Tee 25mm
Supply only Socket 15 mm
Supply only Socket 20 mm
Supply only Socket 25 mm
Supply only Union 15mm
Supply only Union 20mm
Supply only Union 25mm
Supply only Reducer elbow 20mm
Supply only Reducer elbow 25mm
Supply only Reducer Tee 20mm
Supply only Reducer Tee 25mm
Supply only Reducer Socket 20 mm
Supply only Reducer Socket 25 mm
Supply only Hex nipple 15 mm
Supply only Hex nipple 20 mm
Supply only Hex nipple 25 mm
Supply only Tank nipple 15 mm
Supply only Tank nipple 20 mm
Supply only Tank nipple 25 mm
Supply only Plug 15mm
Supply only Plug 20mm
Supply only Plug 25mm
Supply only Nipple 15 mm
Supply only Nipple 20 mm
Supply only Nipple 25 mm
Supply only Ball valve 15mm
Supply only Ball valve 20mm
Supply only Ball valve 25mm
Supply only Gate valve 20 mm, ISI marked all as specifiedand directed
Supply only Gate valve grade 25 mm, ISI marked all as specifiedand directed
Supply only GI pipe medium grade 25 mm, ISI marked all as specifiedand directed
Supply only GI pipe medium grade 15 mm, ISI marked all as specifiedand directed
Supply only GI pipe medium grade 20 mm, ISI marked all as specifiedand directed
Supply only clamps as per sample
Supply only flexible hose pipe 20 mm as per sample
Supply only gasket as per sample
Supply only of M-Seal
Supply only float valve 20 mm
Supply only Tank lid 200 ltrs
Supply only Tank lid 500 ltrs
M&L for opening of solar plate & repairing of leakage copper pipe with complete gas welding/soldering as required on complete copper tubing in solar water heater and after completion of job reassembling the same complete all as specified and directed
Dismantling existingsolar water heater 100/200Ltr and descaling the pipe by means of descaling agent the same reassembling after completion of work Note : Descaling agent shall be paid and measured separately
M&L for painting of solar water heater of old MS stand with monkey cage of tank duly painted of one coat of Black enameled paint complete all as specified and directed
Cleaning of overhead tank 200 Ltr by cleaning brush complete draining of old water and checking no float valve broken or no leakage found after cleaning of OH tank
S&F in replacement of Rotational moulded polyethylene water storage three layers tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 200 Ltrs all as specified and directed by Engr-in-Charge
NOORI ELECTRIC ENGINEERING WORKS
SHAHJEE FRIDGE SERVICE
aditya construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .