Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹10.8 L+₹1.1 L (11.2%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L2 | Rejected-Finance Highest | |
| 3 | L3₹11.3 L+₹1.5 L (15.5%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L3 | Rejected-Finance Highest |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
30 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER ARMY UTILITY JODHPUR
GARRISON ENGINEER ARMY UTILITY JODHPUR
REPAIR, MAINTENACE, SERVICING OF STANDBY DIESEL ENGINE DRIVEN GENERATING SETS AND ITS CONNECTED MISC ITEMS LOCATED AT SECTOR B AND C UNDER GE ARMY UTILITY AREA JODHPUR
2022_MES_533501_1
8809/E8
Open Tender
Civil Works
Item Rate
330 days
GARRISON ENGINEER ARMY UTILITY JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER ARMY UTILITY JODHPUR
₹24,000
Yes
23 Aug 2022
25 Jun 2022
6 Aug 2022
25 Jun 2022
30 Jul 2022
9 Jul 2022
60 days
Amount
M & L for Routine Maintenace/servicing of DG set of capacity 20 to 30 KVA including alternator, electric panel board connection to DG set for Monthly maintainance, quarterly maintainance , half yearly maintainance, as per OEM check list & maintaine proper records of the same and submit to Engineer-in-charge after every maintainance. Repair and labour cost of item is included in quoted rates and replacement of new item will be measured and paid seperatly under relevant items. Location of DG sets are : WAR CENTER,71 WIEU, HRC,GOC HOUSE,2 TAC, FILTER PLANT,33 ME REGIMENT,STN HQ, CPH,SSE,ZONAL W/SHOP,AJMER LINE P/H, SPH-7,MES IB, KONARK HUT, HQ JOSA, 12 CORPS, FOL DEPOT. Note: Servicing/maintanace of the DG set should be followed as per the instructions given under: Checking and rectifyng of (i) Battery charging system , level up Electrolite and specific gravity. (ii) Leakage in fuel lines & connections of fuel pump. (iii) Leakage of Lub. Oil and cooling system, hose pipe & connection, belts tension, fan hub drive pully and water pump and cleaning of water separation and cooling system. (iv) condensate trap. Repair of leakage/ maintenance of water cooling system. Cleaning of radiator by draining out of Coolent, checking of all hose pipes, nut & bolts and tightening properly including checking of leakages all as directed by Engr-in-Charge. (v) Reset the complete switches in automatic lighting connection. (vi) Cleaning of complete D G Set, check and tightening of all nut &bolts including replacement of U/S parts , oiling/ greasing of all movable parts and unusual vibration. (vii) Leakage in exhaust system and exhaust restriction, drain out condensate trap. Repair of leakage/ maintenance of water cooling system. Cleaning of radiator by draining out of Coolent, checking of all hose pipes, nut & bolts and tightening properly including checking of leakages all as directed by Engr-in-Charge. (viii) Reset the complete switches in automatic lighting connection. (ix) Cleaning of complete D G Set, check and tightening of all nut & bolts including replacement of U/S parts , oiling/ greasing of all movable parts and unusual vibration. (x) Check all electrical connection of alternator and control wiring. (xi) Check all earthing connection of DG Set, repair the same if required. (x) Check all electrical connection of alternator and control wiring. (xi) Check all earthing connection of DG Set, repair the same if required. (xii) Drain out old used engine oil from the DG Set cleaning the sump Properly including opening of “B” check kit.Filling of Engine Oil 20W40 or as recommended by the manufacturer, Qty of Engine Oil is specified separtly (xiii) Opening of all filters such as diesel filters, oil filters, Air filter and other required items. proper cleaing of the items and reinstalling or replace the same if required. ( xiv) Testing the D G Sets after completion of work. (xv) Contractor shall employ skilled labour (FGM) for the above repairs. All the complaints arised should be attended and solved on the same day within one hour and one company engineer/ technician for over all repairs. Note:- Replacement of required spare parts will be measured and paid separately.
All as per Item No 1.00 and 1.01 but for 30 to 63 KVA
All as per Item No 1.00 and 1.01 but for 63 to 125 KVA
All as per Item No 1.00 but for 125 to 200 KVA
All as per Item No 1.00 but for 200 to 400 KVA
All as per Item No 1.00 but for 400 to 625 KVA
M&L as in replacement of fuel flow filter with ring including screen filter for D G Sets of capacity 625 KVA.
All as per Item No 2.00 but for capacity 200/180/160 KVA.
All as per Item No 2.00 but for capacity 125 KVA,110 KVA & 100 KVA:
All as per Item No 2.00 but for capacity 62.5,63,50 & 40 KVA
All as per Item No 2.00 but for capacity 380 KVA
All as per Item No 2.00 but for capacity 20 KVA to 30 KVA
M&Las in replacement of By Pass filter for D G Sets of capacity 625 KVA.
All as per Item No 3.00 but for capacity 200/180/160 KVA.
All as per Item No 3.00 but for capacity 125 KVA,110 KVA & 100 KVA:
All as per Item No 3.00 but for capacity 62.5,63,50 & 40 KVA
All as per Item No 3.00 but for capacity 380 KVA
All as per Item No 3.00 but for capacity 20 KVA to 30 KVA.
M&Las in replacement of Oil filter for D G Sets of capacity 625 KVA.
All as per Item No 4.00 but for capacity 200/180/160 KVA.
All as per Item No 4.00 but for capacity 125 KVA,110 KVA & 100 KVA:
All as per Item No 4.00 but for capacity 62.5,63,50 & 40 KVA
All as per Item No 4.00 but for capacity 380 KVA
All as per Item No 4.00 but for capacity 20 KVA to 30 KVA
Supply and filling of superior grade engine oil 20W40 for DG set topping .Make:HPCL/BPCL/IOCL
Supply & filling only coolent "K' Cool Super plus 50-50 Premix for radiator of water cooled engines of any make/capacity and as per manufacturers recommendation, all as specified and directed.
Supply and topup / replace distilled water for battery or radiator of engine used with coolent "K' Cool Super plus 50-50 Premix all as specified and directed.
Dismantling unserviceable battery charging dynamo from DG set of rating 1 x 12 / 2 x 12 Volts complete repairs and servicing including replacement of bushes, bearings, Carbon brushes, rectifires, rewinding of field magnet coil / rotor armeture coils and any other minor parts required all as directed and fixing on engine testing/commissioning complete for DG set having any capacity. Note : Replacement of rotor armeture coil if reqd shall be measured and paid seperately.
Dismantling self starter 12V/24 V of DG set for repairing the starter by replacing carbon brushes, brush holder, bearings, solenoid coil, replacement of burnt aremeture, rewinding of Fd coils, replace of pinion gears etc, completer servicing and refixing after repair, testing/commissioning complete for DG Set any capacity
S&F as in repair of solenoid coil suitable for DG set of capacity200 to 625 KVA self starter Make : L&T, BCH, AE, GE, Standard
S&F as in repair of armeture coil complete with shaft suitable for DG set self starter MAkE : L&T, BCH, AE, GE, Standard
S&F as in repair of pinion gear suitable for DG set self starter. MAkE : L&T, BCH, AE, GE, Standard
Dismantling old unserviceable battery charging dynamo of rating 12/24 volts and supply and fixing new battery charging dynomo same as per existing model suitable for fixing on DG set, 1500 rpm including testing after complete installation all as directed and specified. Make-LUCAS TVS or as exiting make to suit DG set all as specified and directed by engineer-in charge
Dismantling old unserviceable Self starter of Disel engine and supply and fixing new self starter of working voltage 12 volt/24 Volt DC and same as per existing model suitable for fixing on engine set including testing after complete installation all as directed and specified.
S&F as in replacement of 'V' belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for any type of DG Sets.20 KVA to 200 KVA
S&F as in replacement of EC2 AMF logic relays, suitable for DG set of any capacity AMF panel board. Make :Schneider/Standards/L&T/Havells/C&S
S&F as in replacement of Auxilary contactor, 230 volt, AC, suitable for 62.5 to 200 kva DG set AMF panel board. Make :Schneider/Standards/L&T/Havells/C&S
S&F as in replacement of Auxilary contactor, 24 volt, DC, suitable for 62.5 to 200 kva DG set AMF panel board. Make :Schneider/Standards/L&T/Havells/C&S
S&F as in replacement of Indicating lamps, 230 volt, AC, LED type suitable for DG set AMF/LT panel board.
S&F as in replacement ofoverload relay 10Amp to 80 Amp suitable for AMF/LT panel board. Make : Schneider/Standards/L&T/Havells/C&S
S&F as in replacement of rotary switch 3 pole, 3 way suitable for DG set AMF panel board. Make : L&T/Salzer
S&F as in replacement of rotary switch 2 pole, 2 way suitable for DG set AMF panel board. Make : L&T/Salzer
S&F as in replacement of ON/OFF switch, single pole suitable for DG set AMF panel board. Make : L&T/Salzer
S&F as in replacement of SMPS automatic battery charger 12/24 volt 32 AH suitable for DG set AMF panel board.
S&F as in replacement of VMR protection device 3 phase, 415V suitable for DG set AMF panel board.
S&F as in replacement of multifunction AMF panel control meter as per existing make provided in AMF panel board.
S&F as in replacement of Voltmeter, Digital type, 230V suitable for DG set AMF panel board.
S&F as in replacement of Ameter Digital type, with suitable ration CT, 230V suitable for DG set AMF panel board.
S&F as in replacement of 'V' belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for any type of DG Sets.250 KVA to 625 KVA
S&F as in replacement of Air filter element inner and outer suitable for existing type of modele DG set Engine of capacity 380 KVA.
S&F as in replacement of Air filter element suitable for existing type of modele DG set Engine of capacity 200 KVA.
S&F as in replacement of Air filter element inner and outer suitable for existing type of modele DG set Engine of capacity 160 KVA.
S&F as in replacement of Air filter element inner and outer suitable for existing type of modele DG set Engine of capacity 125 KVA
S&F as in replacement of Air filter element inner and outer suitable for existing type of modele DG set Engine of make Kirloskar and capacity 100 KVA.
S&F as in replacement of Air filter element inner and outer suitable for existing type of modele DG set Engine of capacity 62.5 KVA.
S&F as in replacement of Air filter element inner and outer suitable for existing type of modele DG set Engine of capacity 50 KVA.
S&F as in replacement of Air filter element inner and outer suitable for existing type of modele DG set Engine of capacity 20 to 30 KVA.
M&L for draining out coolent water from radiator, dismantling radiator, repair of radiator for leakage if any, cleaning the radiator set with dilute HCL, kerosin, fresh water and refixing the same with new rubber hose with clamps filling with coolent with distilled water and checking for its proper function on DG set all as directed and specified. Note : Coolent and distilled water shall be measured and paid separately under relavant items.
Supply only waste cotton for cleaning of DG sets and installations complete all as per sample given and approved by Engr-in-Charge.
S&F as in replacement of battery lead length not less than 1.25 Mtr long and not more than 2.5 mtr as per connection requiremnt of each DG set, PVC insulated multistranded copper conductor 70 sqmm single core, duly fixed brass clamps, copper lugs for connections from DG battery to self starter on DG Sets of any capacity .
Labour only for attending breakdowns of DG sets/AMF panels through skilled technician from reputed service centre of DG sets with necessary tool kits, checking Engine and alternator for defects, carryout necessary repairs works to rectify the defects without major overhauling/opening of Engine or Alternators, replace of external spare to repair/rectify the defects and testing DG set for its smooth functioning on full load all as specified and directed by Engr-in-charge. Note : 1. Necessary spares required to rectify the defects shall be measured and paid separately under relavant items. 2. The complaint shall be attended and rectifed within 24 hrs form time of reporting by Engr-in-Charge or his auth representative. 3. Any Major defects shall be reported on Priority to Engr-in-charge to avoid undue delay in fuctioning of installation.
S&F as in replacement of controller of AMF/DG panel with defective controller carried model and type as per existing to DG set of any capacity
S&F as in replacement of fuel inlet manifold.
S&F as in replacement of fuel return manifold.
S&F as in replacement of micro switch.
S&F as in replacement of mannual fuel pump of DG set any capacity.
S&F as in replacement of electronics governor to fuel to existing type and size and model all as specified and direction .
S&F as in replacement of banjo bolt with washers .
S&F as in replacement of moving contact & fixing contact set of contactor capacity 100 to 200 Amp
S&F as in replacement of moving contact & fixing contact set of contactor capacity 20 to 50 Amp
S&F as in replacement of moving contact & fixing contact set of contactor capacity 50 to 100 Amp
S&F lugs of size 2.5 sq mm to 10 sq mm.
S&F lugs of size 10sq mm to 40 sqmm .
S&F lugs of size 50 sq mm to 150 sq mm.
S&F as in replacement of terminal block of suitable size with four terminal including nuts ,bolts ,washers with all acessries matarial.
S&F as in replacement of power contactor of capacity 63A-100A make and model as per existing in the DG set Panel all as specified and directed.
S&F as in replacement of power contactor of capacity 160A-250A make and model as per existing in the DG set Panel all as specifided and directed.
S&F as in replacement of power contactor of capacity 250A-360A make and model as per existing in the DG set Panel all as specified and directed.
S&F as in replacement of power contactor of capacity 400A-500A make and model as per existing in the DG set Panel all as specified and directed.
S&F in replacement power contactor of size capacity 20 to 100 amp model as per existing in the DG set all as specified and directed.
S&F in replacement flexible fuel pipe complete set with banjo bolt and washer etc.
Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity ranging from 20 KVA to 62.5 KVA all as per existing sample with GI clamps and Nut bolt, washers for DG set as directed by Engr-in-charge.
Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity ranging from 100 KVA to 200 KVA all as per existing sample with GI clamps and Nut bolt, washers for DG set as directed by Engr-in-charge.
Supply only rubber hose pipe set (Hose oil/Hose radiator/CR Hose/Makeup Hose) suitable for DG sets of capacity 250 to 650 KVA and above all as per existing sample with GI clamps and Nut bolt, washers for DG set as directed by Engr-in-charge.
M&L for laying, jointing, testing cable XLPE insulated, armored and PVC sheathed LT 1100 volts grade and aluminum conductor confirming to IS 1554 laid in trenches/through pipe/floor/fixed wall etc complete all as specified and directed for size of cables 50 Sqmm 3.5 core stranded conductor
All as per item No 66 but size of cable 95 Sqmm 3.5 core stranded conductor.
All as per item No 66 but size of cable 120 Sqmm 3.5 core stranded conductor.
All as per item No 66 but size of cable 150 Sqmm 3.5 core stranded conductor.
S&F as in replacement of MCCB four pole, 415 Volts, 250 Amps capacity 36 KA rating with thermal relay and as per model & make provided in existing panel board complete all as specified and directed.
S&F as in replacement of MCCB four pole, 415 volt 125 Amps capacity 25 KA rating with thermal relay and as per model & make provided in existing panel board complete all as specified and directed.
S&F as in replacement of MCCB four pole, 415 volt 100 Amps capacity 25 KA rating with thermal relay and as per model & make provided in existing panel board complete all as specified and directed.
S&F as in replacement of ON LOAD change over switch, 4 pole, 415 Volts,& repair assembly according to existing panel 100 Amps capacity and as per model & make provided in existing panel board complete all as specified and directed.
S&F as in replacement of ON LOAD change over switch, 4 pole, 415 Volts,& repair assembly according to existing panel 250 Amps capacity and as per model & make provided in existing panel board complete all as specified and directed.
S&F as in replacement of ON LOAD change over switch, 4 pole, 415 Volts, 315 Amps capacity and as per model & make provided in existing panel board complete all as specified and directed.
S&F as in replacement of ON LOAD change over switch, 4 pole, 415 Volts, 400 Amps capacity and as per model & make provided in existing panel board complete all as specified and directed.
S&F as in replacement of HRC Fuge link and with basse plate 800 amp as per existing panel board complete all as specified and directed.
S&F as in replacement of HRC Fuge link and with basse plate 400 amp as per existing panel board complete all as specified and directed.
S&F as in replacement of HRC Fuge link and with basse plate 315 amp as per existing panel board complete all as specified and directed.
S&F as in replacement of HRC Fuge link and with basse plate 200 amp as per existing panel board complete all as specified and directed.
S&F as in replacement of HRC Fuge link and with basse plate 100 amp as per existing panel boardcomplete all as specified & directed.
S&F door Stainless steel hinges for DG set canopy complete all as specified & directed.
S&Facrylic cear plastic plexiglass 3mm thick sheet cut into required shape and fix on to DG set Canopy using rubber gasket as per existing sample after removing the old broken existing sample complete all as specified & directed.
Nvimal Engineers and Contractor
Shri Electrical Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .