AGE(I) Raiwala
AGE(I) Raiwala Raiwala Cantt Dehradun (U.K)
REPAIR AND REPLACEMENT OF LT OH LINES, LT UG CABLE AND ALLIED WORKS IN OTM ACCN UNDER AGE (I) RAIWALA
2021_MES_493004_1
8879/E8
Open Tender
Civil Works
Item Rate
180 days
Raiwala
As per tender documents
10 documents required · 10 mandatory
₹500
AGE(I) Raiwala
₹20,000
Yes
7 Mar 2022
8 Dec 2021
1 Jan 2022
8 Dec 2021
29 Dec 2021
15 Dec 2021
Amount
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for poles, laying of electric cable and GI tubing (where provided for protection of cables) and getting out trimming the sides, forming bottom surface to required level in any type of soil complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5 metre wide and exceeding 1.5 metre but not exceeding 03 mtr, in depth or part thereof in depth beyond the first 1.5 meter for poles, laying of electric cable and GI tubing (where provided for protection of cables) and getting out trimming the sides, forming bottom surface to required level in any type of soil complete all as specified and as directed.
Returning, filling in , including spreading, leveling, watering and well ramming in layers not exceeding 25 centimetre thick in any type of soil complete all as specified and as directed.
Removing excavated material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
M&L for riddled earth to cushioning below and over UG cable including spreading, levelling to underground cable in trench all as specified and directed.Note: Punning not done by riddled earth. The riddled earth means those excavated soil cleared with stone particles.
Material and labour for cable protection with sub class ‘B’ bricks old size, laid dry, flat over sand cushining of cable, perpendicular across the cable in trenches complete all as specified and as directed.
Taking down unserviceable serviceable cable /UG cable of any size upto50 Sqmm carefully from trenches/poles/ducts/LT panels, OH conductors and relay at different locations all as specified and directed by Engr-in-Charge.
Labour only for laying, fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, insulated, armoured heavy duty electric cable with aluminium conductor, XLPE , 1100 volts grade, cross-sectional area of size 120 Sqmm sqmm 3.5 core with all as specified and directed. by Engr-in-charge (Note: XLPE UG Cable shall be issued by department under Sch B)
All as per item No. 08 here-in-before but 70 sqmm 3.5 core complete all as specified
All as per item No. 08 here-in-before but 25 sqmm 3.5 core complete all as specified
All as per item No. 08 here-in-before but 16 sqmm 2/4 core complete all as specified
All as per item No. 08 here-in-before but 10 sqmm 2 core complete all as specified
Dimantling and taking down old/unsv cross arms, bracing, supports etc complete carrying to store for credit all as specified and directed.
M&L steel work in FE-410-S grade for cross arms, bracing, supported, clamps & back plates fabricted from structural steel section including nuts, bolts, washers, welding, Bending cold and hot Drilling hole for bolts, in any size as indicated or directed and inclusive of one coat of red oxide primer one under coat and one finishing coat of paint aluminium complete all as specified and directed.
Dismatling and taking down old/unsv ACSR conductor any size complete to carrying to store for Credit all as specified and directed
S&F ACSR conductor incl jointing with existing conductor and stringing on LT pole and proper fastening to pin/shackle insulators with aluminium binding wires and required jumpering connection all as directed.
Dimantling and taking down old/unsv LT insulator of any type any size from pole/stay or carrying to store for credit complete all as specified and directed.
S&F pin type, porcelain, vitreous, brown, including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 100mm height and 65 mm dia for 1100 volts grade all as specified and directed..
S&F shackle type,porcelian vitreous white, brown or green insulator including galvanised mild steel straps , washers, insulators bolts ,washer and nuts of size 100 mm height and 115 mm dia for 1100 Volts grade complete all as specified and directed.
Earthing complete with galvanised steel earth plate eletrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected by 32 x 6 mm GI strip as earth lead by means of brass nuts and bolt, thimbles, check nuts, washers including concrete chamber of PCC 1:3:6 type c-1 using 20 mm graded stone aggregate, with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x 300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320 x 320 x 80 m size (1:2:4) Type B1 using 20 mm graded stone aggregate, adequate quantity of common salt, charcoal etc all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including and provision of GI strip upto 7.5 mtr long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing strip to an earthing test point/panel including testing on completion complete all as specified and directed by Engr-in-Charge. (i) RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 Kg/Sqm in lieu of CI cover. (ii) Cost of additional GI strip more than 7.5 meter will be measured and paid seperately under relevant item.
Labour only for restringing of overhead ACSR conductor of any size of 4 wire and 2 wire on pole after disconnecting all jumper connection & binding of insulators and including rejointing all connections and insulators, jumper binding with aluminium conductorcomplete all as specified and directed . Note : (i) Pole to pole distance will be measured as one span (ii) In Pole to Pole 4 wire and if found 2 wire each conductor measured as one span.
M & L for jointing the LT cable with Cold straight through joint, by disconnecting the cable ends, removing the damaged portions of cable, by suitable means, joining by ferrules etc and testing for LT 1100 V cable of size 3.5/4 core 25-50 Sqmm all as directed and specified.
M & L for jointing the LT cable with Cold straight through joint, by disconnecting the cable ends, removing the damaged portions of cable, by suitable means, joining by ferrules etc and testing for LT 1100 V cable of size 3.5/4 core 70-95 Sqmm all as directed and specified.
Supply only GI tubing light grade 40mm bore, ISI marked, for cable protection
Supply only GI tubing light grade 50mm bore, ISI marked, for cable protection
M/L for trimming of branches of trees touching LT electric over head line and making clear about 3 mtr in radius by climbing up tree or by providing ladder, at a height of 9 mtr and above and carrying and depositing where directed not exceeding 50 mtr. Note : (i) Necessary T & P items arrange by contractor. (ii) While cutting the tree branches the fallen branch damaged the contactor, insulator, pole the contractor should be replaced the said items without any extra cost. If contrctor failed to rectify the complaint withing 4 hours of time period the penalty of Rs 10000 imposed per hour till rectify (iii) Cutting of tree consider in each span only not no of tree in one span have 10 trees it cnsider only one span.
S&F rigid PVC line separator suitable for 2 wire, made from high grade PVC material, rigid PVC Spacer, distance betwen phase to phase 300mm, suitable for use with 1100 volts grade. Make- Shree Balaji Power Plast/Goyal Power Plast/Jaipuria brothers
S&F rigid PVC line separator suitable for 3 wire, made from high grade PVC material, rigid PVC Spacer, distance betwen phase to phase 600mm, suitable for use with 1100 volts grade. Make- Shree Balaji Power Plast/Goyal Power Plast/Jaipuria brothers
S&F rigid PVC line separator suitable for 4 wire, made from high grade PVC material, rigid PVC Spacer, distance betwen phase to phase 900mm, suitable for use with 1100 volts grade. Make- Shree Balaji Power Plast/Goyal Power Plast/Jaipuria brothers
M&L for road cutting and boring of road without damage surface and inserts GI pipe and cable without any damage of any size making good with PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) of 150mm X 100mm inrespect of width and thickness complete all as directed by Enger -in- charge.
M & L for Dismantling weakend stay assembly complete and M & L for Stay assembly complete with accessories as shown in electrical plate No. 1,i.e Stay rod 1.8 Mtr length 16 mm dia and size of stay grip 7/2.50 mm, size of stay plate 230 x 230 x 6 mm mild steel galvanised material, stay bows shall be of mild steel galvanised of 14 mm dia and 40 cm length all shown as per MES SSR Part-I, , the stay rod shall be embedded in cement concrete 1:3:6 type C 2 to a depth not less than 1.67 Meters in such a way that the top of the concrete block so formed is well below the ground level to prevent uprooting of the stay rod. A stay rod of length 1.8 mtrs and dia 16 mm dia , length of remaining 45 cm of the stay rod shall project above the ground level. The stay wire of size 7/3.15 mm shall be fixed to the stay rod at the bottom and to the stay clamp to the pole, by means of well spiced joints with a porcelain guy insulator of size 65 x 95 mm placed 3 Mtr above the ground level and a turn back to inserted in the middle and near the top respectively.The stay clamps shall be located near about the centre of gravity of the pull of the over head conductors, stay rod and thimble shall be in correct alignment with stay wire. The angle between the pole and the wire should be about 45˚ to 30˚ complete all specified and directed by Engr-in charge. (Note: Excavation, earth work, PCC deemed to be included in the quoted rate)
M & L for Cradle guard for existing LT OH line as per IE specification of type Heagonal/rectangular,fabricated with galvanised steel wire 4mm dia all as specified and directed by Engr-in-Charge.
Dismantling unserviceable broken steel pole, struts of any size form the site and removing existing concrete block complete all as specified and directed by Engr-in-Charge.
Supplying and erecting in true vertical position steel tubular swaged pole, 09 metres long, type 410 SP-31, complete with cast iron base plate, pole cap, final taper plug, bolts, nuts, washers etc including necessary earth work and excavation, PCC in foundation 1:4:8 type D2, using 40 mm graded stone aggregate and PCC 1:3:6 type C2, using 40 mm graded stone aggregate as in plinth block, disposal of surplus soil to a distance not exceeding 50 m, painting two coats of aluminium paint over one coat of red oxide primer including 3 nos band/straps with colour (200mm wide each) synthetic enamelled paint at a distance 200 mm from plinth, block and marking pole nos with black synthetic enamelled paint including tarring one coat on steel surface embedded in concrete and provided anti climbing device and danger notice plates etc) complete all as specified and directed.(Note:Excavation and PCC work measured and paid separtely)
M&L PCC 1:4:8 type D-2, using 40 mm graded stone aggregate, as in foundation, filling, mass concreting etc, complete all as specified and directed.
M &L for Cement concrete Type C-2, 1:3:6 (40 mm in graded aggregate) foundations,filling and mass concrete for foundation and cassing of pole and demolition of existig coping and construct new coping complete all as specefied and directed.
Supply and fix Bus bar chamber made out of 3.15 mm thickness sheet metal enclousre totaly enclosed outdoor type, vermin proof, powder coated paint, metal clad with porcelain insulator and colour coated tinned copper bus bar 415 volts, 200 Amps rated, 4 pole for connecting UG cable, fixed on existing pole or new pole and required size of steel clamp, screw, bolt, nut, washers for tightend with pole, in outer site the letters shown Danger 440 volts in black colour all as specified and directed by Engr-in-Charge
Decarbonizing and spary painting of indoor/outdoor APFC Panel any type removing unserviceable MCCBs, burnt busbars, unserviceable indicator lamps, unserviceable Ammeter, unserviceable Volt meter , capacitors, contactors, APFC relays, replacing burnt, damaged bus bar of any size and fixing proper hanging front and rear openings, welding of hinges including welding of broken MS sheet using extra sheets replace burnt thimbles with new existing size thimbles replacing with new MCCB and cut the sheet as per size required for MCCB and capacitors and contractors if required, if any opening on panel found welded with MS sheets, incluidng dismantling the existing connected cables and re-connecting the same setting programme, testing of CT including caliberation after servicing testing panel and achive power factor of 1.000 all as directed and satisfied by Engr-in-Charge. (Note: (i)Capacitors, capacitor contactor, power factor controller measured and paid separately as S & F item in relevent schedule. (ii) The rate for required MS sheet of thickness 2 mm to 3 mm and welding of parts included on quoted rate.
Supply and fix test, commissioning of LT capacitor 10 KVAR suitable voltage up to 440 V, 50 Hz, fix on existing APFC panel and necessary connection with 2 x 6 Sqmm finely stranded copper conductor from capacitor to condcutor and CTs, and APFC relays,MCBs all as directed and satisfied by Engr-in-Charge Make: capacitor L & T Cat No: LTBCD310B2 or equivalent make of Legrand/Schneider (i) Note: Capacitor, control wiring all are deemed to beincluded in the quoted rate.
Supply and fix test, commissioning of LT capacitor 20 KVAR suitable voltage up to 440 V, 50 Hz, fix on existing APFC panel and necessary connection with 2 x 6 Sqmm finely stranded copper conductor from capacitor to condcutor and CTs, and APFC relays,MCBs all as directed and satisfied by Engr-in-Charge Make: capacitor L & T Cat No: LTBCD320B2 or equivalent make of Legrand/Schneider (i) Note: Capacitor, control wiring all are deemed to beincluded in the quoted rate.
Supply and fix test, commissioning of LT capacitor 15 KVAR suitable voltage up to 440 V, 50 Hz, fix on existing APFC panel and necessary connection with 2 x 6 Sqmm finely stranded copper conductor from capacitor to condcutor and CTs, and APFC relays,MCBs all as directed and satisfied by Engr-in-Charge Make: capacitor L & T Cat No: LTBCD315B2 or equivalent make of Legrand/Schneider (i) Note: Capacitor, control wiring all are deemed to beincluded in the quoted rate.
Supply and fix test, commissioning of LT capacitor 30 KVAR suitable voltage up to 440 V, 50 Hz, fix on existing APFC panel and necessary connection with 2 x 6 Sqmm finely stranded copper conductor from capacitor to condcutor and CTs, and APFC relays,MCBs all as directed and satisfied by Engr-in-Charge Make: capacitor L & T Cat No: LTBCD330B2 or equivalent make of Legrand/Schneider (i) Note: Capacitor, control wiring all are deemed to beincluded in the quoted rate.
Supply and fix test, commissioning of LT capacitor duty contactor of kVAr rating 10 KVAr, 440 V, three phase, 50 HZ ,MO C10 detaching type, the contactor provided with damping resistors and separate termination for damping resistors, encapsuled resistor assembly, modular type,common coil for 50 & 60 Hz, low pick up VA consumption, suitable for Lug as well as lugless termination fix on existing APFC panel and necessary connection with 2 x 6 Sqmm finely stranded copper conductor from capacitor to condcutor and CTs, and APFC relays,MCBs all as directed and satisfied by Engr-in-Charge contactor Make L & T cat No: CS96156 or equivaltnt make of Legrand /Schneider. Note: Contactor, control wiring all are deemed to be included in the quoted rate.
Supply and fix test, commissioning of LT capacitor duty contactor of kVAr rating 20 KVAr, 440 V, three phase, 50 HZ ,MO C20 detaching type, the contactor provided with damping resistors and separate termination for damping resistors, encapsuled resistor assembly, modular type,common coil for 50 & 60 Hz, low pick up VA consumption, suitable for Lug as well as lugless termination fix on existing APFC panel and necessary connection with 2 x 6 Sqmm finely stranded copper conductor from capacitor to condcutor and CTs, and APFC relays,MCBs all as directed and satisfied by Engr-in-Charge contactor Make L & T cat No: CS90021 or equivaltnt make of Legrand /Schneider. Note: Contactor, control wiring all are deemed to be included in the quoted rate.
Supply and fix test, commissioning of LT capacitor duty contactor of kVAr rating 15 KVAr, 440 V, three phase, 50 HZ ,MO C15 detaching type, the contactor provided with damping resistors and separate termination for damping resistors, encapsuled resistor assembly, modular type,common coil for 50 & 60 Hz, low pick up VA consumption, suitable for Lug as well as lugless termination fix on existing APFC panel and necessary connection with 2 x 6 Sqmm finely stranded copper conductor from capacitor to condcutor and CTs, and APFC relays,MCBs all as directed and satisfied by Engr-in-Charge contactor Make L & T cat No: CS90019 or equivaltnt make of Legrand /Schneider. Note: Contactor, control wiring all are deemed to be included in the quoted rate.
Supply and fix test, commissioning of LT capacitor duty contactor of kVAr rating 30 KVAr, 440 V, three phase, 50 HZ ,MO C30 detaching type, the contactor provided with damping resistors and separate termination for damping resistors, encapsuled resistor assembly, modular type,common coil for 50 & 60 Hz, low pick up VA consumption, suitable for Lug as well as lugless termination fix on existing APFC panel and necessary connection with 2 x 6 Sqmm finely stranded copper conductor from capacitor to condcutor and CTs, and APFC relays,MCBs all as directed and satisfied by Engr-in-Charge contactor Make L & T cat No: CS96148or equivaltnt make of Legrand /Schneider. Note: Contactor, control wiring all are deemed to be included in the quoted rate.
Supply and fix MCB Triple Pole, 25 to 32 Amps, C curve, 10 KA breaking capacity fix on APFC and nomral panel as per site requiredment and contactors capacity all as specified and directed by Engr-in-Charge.
Supply and fix MCB Triple Pole, 40 to 50 Amps, C curve, 10 KA breaking capacity fix on APFC and nomral panel as per site requiredment and contactors capacity all as specified and directed by Engr-in-Charge.
Taking down old unserviceable CT coil and S & F CT coil up to -/5 A capacity all as directed by Engr-in-Charge.
Decarbonizing of LT indoor/outdoor Panel/feeder pillar box any type removing unserviceable MCCBs, burnt busbars, unserviceable indicator lamps, unserviceable Ammeter, unserviceable Volt meter , replacing burnt, damaged bus bar of any size and fixing proper hanging front and rear openings, welding of hinges including welding of brokieng MS sheet using extra sheets replace burnt thimbles with new existing size thimbles replacing with new MCCB, incluidng dismantling the existing connected cables and re-connecting the same cables complete all as specified and directed by Engr -in- charge. Note : (i)MCCBs,indicator lamps, Multifunction meter, CTs will be measured & paid separately at relevent schedule of item. (ii) necessary MS sheet and weleding, bus bars in the quoted rate.
Supply and fixing MCCB, 4 pole, 16 KA breaking capacity, adjustable type, 160 amps, incl dismentling taking down unsv one, making cutting of existing panel for fixing MCCB on suitable fitting and make panel good covering with sutiable sheet metal and welding all as directed by Engr-in-charge. make- Hager//Legrand/L & T
Supply and fixing MCCB, 4 pole, 16 KA breaking capacity, adjustable type, 250 amps, incl dismentling taking down unsv one, making cutting of existing panel for fixing MCCB on suitable fitting and make panel good covering with sutiable sheet metal and welding all as directed by Engr-in-charge. make- Hager//Legrand/L & T
Supply and fixing MCCB, 4 pole, 16 KA breaking capacity, adjustable type, 400 amps, incl dismentling taking down unsv one, making cutting of existing panel for fixing MCCB on suitable fitting and make panel good covering with sutiable sheet metal and welding all as directed by Engr-in-charge. make- Hager//Legrand/L & T
Supply, fix of RYB indicator lamp LED type( set of three lamp) for incoming and outgoing supply by making suitable hole of sizes all as directed by Engineer-in-Charge.Make: L & T or equivalent make of Schneider
Labour only for hardcore of gauge n.exc 40mm ,deposited, spread, and levelled in layers n.exc 15 cm thickness (below or above ground level) ,water and rammed to a true shape with broken stone or boulders existing available on site and making good all as specified and directed by Engr-in-Charge.
M&L for cleaning of MES electric supply installations/campus inside Transformer chain linking fencing and from outer area of chain link fenicing i.e distance from fencing of 2 Mtrs by surface dressing or trimming of natural ground to remove small unequalities not exc 15 cm deep (including removing vegetation/ shrubs/brush wood/under growth) and carrying away the rubbish to a distance of not exc 50 mtr away complete at an interval of every month for the various sub stations.
TARUN ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .