Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC lowest bid |
| 2 | L2₹1.3 Cr+₹6.7 L (5.58%)Rejected-Finance SHIV BHAWAN MAGADH COLONY ROAD NO 03 SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | GAYA | BIHAR | 823001 | ₹1.3 Cr+₹6.7 L (5.58%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹1.3 Cr+₹7.2 L (5.97%)Rejected-Finance | ₹1.3 Cr+₹7.2 L (5.97%) | L3 | Rejected-Finance NOT LOWEST |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
12 Jun 2020, 6:00 pmClosed
CWE Ranchi
HQ CWE RANCHI MES DIPATOLI CANTT PO RMCH RANCHI - 834009
PROVN OF BORE WELL IN GC ACCNS AT GCs TOILETS AT GAYA
2020_MES_337700_1
80599/1287/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
Gaya
Class B category a(i) and (ii)
6 documents required · 6 mandatory
₹1,000
Yes
GE GAYA
₹2.1 L
Yes
29 Jun 2020
27 Apr 2020
15 Jun 2020
27 Apr 2020
12 Jun 2020
29 May 2020
Amount
Surface excavation n.exc 30cm deep & averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavating over areas n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating over areas exc 1.5m and n.exc 3.0 mtr in depth and getting out in in soft/loose soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and exc 1.5m but n exc 3 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and not exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering & well ramming in layers n. exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated soil n exc. 50m & depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L PCC (1:1.5:3) type B -1, using 20 mm graded stone aggregate as in foundations, filling and mass-concrete complete all as specified and directed.
Use and waste form work to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams; and similar work; verticle or to batter Rough finished surfaces of concrete flat complete all as specified and directed.
M&L RCC M-30 design mix using 20 mm graded stone aggregates in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M & L for Hard core of Broken stone/boulders gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6), type C-2 using 40 mm graded stone aggregate as in plinth protection and simillar works finished even and smooth without using extra cement complete all as specified and as directed. Note: Joints 12 mm wide to the full depth of PCC shall be provided at every 3 m and at every change of direction and shall be filled with mixture of bitumen and sand 1:3 by weight. Cost of this provn shall deemed to be included in the quoted rate
M&L 25 mm thick PCC (1:2:4) type B-0, using 12.5mm graded stone aggregates mixed with WPC @ 3% by weight of cement or as per manufacturer instruction as in floor, fineshed the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC will be measured and paid separately.
Use and waste formwork to faces of walls, retaining walls, abutments, parapets & staircase railing and similar work including attached pillasters, buttresses, etc.; vertical or to better of rough finished surfaces of concrete flats complete all as specified and as directed.
Use and waste formwork to sides and soffits of domes, vaults, shell roofs and arch ribs of rough finished surfaces of concrete Curved in one plane complete all as specified and as directed.
M&L RCC M-30 design mix using 20 mm graded stone aggregates in walls, basement walls and the like; any thickness; above top of footings; incl attached pilasters and buttresses complete all as specified and as directed.
M&L RCC M-30 design mix using 20 mm graded stone aggregates in Domes, vaults, shell roofs, arch ribs and folded plates etc complete all as specified and as directed.
M&L Rendering 10mm thick on fair faces of concrete surfaces (roof) in CM (1:3) finished even and smooth with using extra cement mixed with WPC @ 3% by weight of cement or as per manufacturer instruction, finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC will be measured and paid separately
M&L Mild steel (TMT) bars of grade Fe 500 D, 10 mm dia and over in Reinforcement cut to length bent to shape required including cranking ends and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L TMT bars of grade Fe 500 D, 6 to 8mm dia as in spacers, binders etc, cut to length bent to shape required including cranking ends and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L TMT bars of grade Fe 500 D, upto 10mm dia as in stirrups, binders etc, cut to length bent to shape required including cranking ends and binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M & L Rendering 5mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling, finished the surface even and smooth without using extra cement complete all as specified and as directed.
M & L Rendering 15mm thick on RCC, stone, masonry surfaces or fair face of brickwork in CM (1:3), finished even and smooth without using extra cement mixed with WPC @ 3% by weight of cement or as per manufacturer instruction, finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC will be measured and paid separately
M&L Rendering 15mm thick on concrete surfaces or fair face of brickwork in CM (1:4), mixed with WPC @ 3% by weight of cement or as per manufacturer instruction, finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC will be measured and paid separately
Supply only water proofing compound (ISI marked)
M & L for cleaning the existing concrete, mortar surfaces, free from loose adhering particles and applying two coat of Flexible Protective and Waterproofing of SikaTop® SeaI-107 in ratio 1:4 and 1st coat consumption 1-1.5 kg/sqm & 2 nd coat consumption 0.8 - 1 Kg / Sqm approx or as per manufacturer instructions complete all as specified and directed.
M&L for two coats of cement based paint over a coat of cement primer including preparation of newly plastered surfaces complete all as specified and directed.
M & L of applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including necessary preparation complete all as specified and directed.
M & L for cleaning of existing concrete, mortar surfaces, free from loose adhering particles and applying two coats of water based protective epoxy coating Sika guard 67 of consumption 0.20 - 0.25 kg/Sqm per coat approx, over a coat of primer of Sikaguard 67 diluted with water (20 % by weight) of consumption 0.15 - 0.20 kg/Sqm for holding drinking water or as per manufacturer instructions complete all as specified and directed.
M & L for RCC M-20 (Design Mix), using 20 mm graded stone aggregatr as in foundation filling, mass concrete complete.
M & L for RCC M-20 (Design Mix), using 20 mm graded stone aggregatr as in Walls, retaining walls, basement walls ballast walls and the like any thickness; above top of footings complete all as specified and directed.
M&L for RCC M-20 Design Mix (using 20 mm graded stone aggregates) in Columns, pillars, piers, posts complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred/stopped end etc. complete all as specified and directed.
S & F of PVC Water Bar 150 x 6 mm thick complete all as specified and directed.
S & F Mild steel framed work such as grills, gratings etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks & similar work conform to Fe 290-0 Gde E-165 complete all as specified and directed.
S & F Stainless steel framed work such as in stairs/ladder and fixed with concrete surfacesincluding necessary fixing arrangments complete all as specified and directed.
S & F of 25 mm dia GI pipe medium grade as in railing and welded to MS frame work including drilling, cuttings etc complete all as specified and directed.
M & L for forming Contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and directed.
S & F of MS Pipe in shortar length and including special fittings for 100/150 mm dia of pipe with Puddle collar, including necessary cutting/welding and made shape as per drawings and inserted in wall all as specifed and directed
S & F G I welded mesh 50mmx50mmx 16 Gauge and fixed with MS frame work complete all as specifed and directed
S & F Stainless steel wire mesh 0.36 mm dia of wire and aperature 1.40 mm and fixed to MS frame work with pins or staples complete all as specified and directed
S & F Stainless Steel grade 304 and 2.00 mtr long screen printed scale board mechanical Type water level indicatior board with dust free housing for pulleys - minimizing friction in movement, Non- stretching multi strand wire rope in stainless steel, modular design complete all as specified and directed
M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming toIS-15658-2006 of 60mm thickness M-35 Grade with grey cement and pigment complete all as specified and as directed.
Supply and spreading of river sand including ramming and consolidation complete all as specified and as directed.
M &L for brickwork with fly ash bricks, straright or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and as directed.
M &L for brickwork with fly ash bricks, straright or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregates as in foundation, filling and mass concrete complete all as specified and as directed
M & L for Brickwork with fly ash bricks in one brick thick honey comb walling, built in Cement Mortar 1:4 complete as speicified and directed.
M&L Brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement and sand mortar 1:4 complete all as specified.
M&L RCC M-25 design mix using 20 mm graded stone aggregates in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC M-25 Design Mix (using 20 mm graded stone aggregates) in Columns, pillars, piers, posts complete all as specified and directed.
M&L for RCC M-25 Design Mix (using 20 mm graded stone aggregates) in beams, cantilevers, bressummers, lintel etc. complete all as specified and directed.
M&L for RCC M-25 Design Mix (using 20 mm graded stone aggregates) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs complete all as specified and directed.
M&L 25 mm thick PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in damp proof course to horizontal or vertical surfaces including necessary form work mixed with liquid water proofing compound as per manufacturer's instructions complete all as specified and directed. Note :- water proofing compond shall be measured and paid separately
Use and waste Formwork to flat sides and soffits of floor or roof beams, beam haunchings, girders,bresumers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc. surfaces rough finished complete all as specified.
Use and waste of Formwork to sides of Square, rectangular or polygonal pillars, posts, struts, piers, columns and stanchions surfaces finished fair as per clause 4.11.16.2 (a) of SSR Part I complete all as specified.
Use and waste of Form work to flat soffits of suspended slabs, floor slabs, landings and similar work; not exceeding 200 mm thick ( Horizontal or sloping) surfaces finished fair in forms complete all as specified and directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs excd 10 cm and n exc 20 cm wide and sides of RCC/PCC bands in walls , horizontal or sloping and similar work complete all as specified surfaces finished fair in forms complete all as specified and directed.
M&L for 10 mm thick rendering in CM (1:6) on fair faces of brick work, surfaces finished even and smooth without using extra cement complete all as sprcified and as directed.
M & L for Hard core of Broken bricks of gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface complete all as specified and directed.
M&L 75mm thick, plain cement concrete 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in sub base complete all as specified.
M&L 25mm thick, plain cement concrete type B0 ( 1:2:4), using 12.5 mm graded crushed stone aggregate in filling in depression/ levelling course of floors , finished the surface even and smooth without using extra cement complete all as specified.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but n.exc 0.18 sqm as in floor etc, with and including over 15 mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces complete all as specified and directed.
M&L for coloured glazed ceramic tiles as in vertical surfaces of size B63(450x350) x7mm thick with and including over10 mm thick cement plaster in CM (1:4); set and jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces complete all as specified and as directed.
M&L Machine cut Kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to give granite finish complete all as specified.
M&L screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in cement and sand mortar 1:4 complete all as specified.
M&L preparation of new surfaces of walls by applying Wall care white ( Putty) thickness not more than 1.5mm and sand papering surfaces to achieve smooth surfaces complete all as specified.
M&L for applying two coats of acrylic Distemper on plastered surfaces including preparation of new plastered surfaces over a coat of primer as in ceiling complete all as specified.
M&L for applying two coats of acrylic Distemper on plastered surfaces including preparation of new plastered surfaces over a coat of primer as on walls complete all as specified.
M&L for applying two coats of cement based paint over a coat of cement primer including preparation of old/newly plastered surfaces of walls complete all as specified and directed by Engr-in-Charge
M&L Forming 12 mm thick Expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound , Grade 'A' , thickness of slab 100 mm thick complete all as specified.
S&F fancy type Chromium plated Stop valves, cast copper alloy, long shank, and cup ( concealed type ) screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle , screwed externally both ends for unions etc. and fixed complete all as specified. Make :- Prayag/Hindware/Parryware
S&F Gunmetal , globe or gate valves, with iron wheel head, screwed both ends for 25 mm bore dia. iron pipe and fixed complete all as specified.
S&F Gunmetal , globe or gate valves, with iron wheel head, screwed both ends for 20 mm bore dia. iron pipe and fixed complete all as specified.
S&F Chromium plated fancy long body Bib taps with cup , cast copper alloy with crutch handle, screwed for 15 mm bore dia. iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F 15 mm dia bore CP angle cock cast copper alloy , screwed down high pressure with crutch or butterfly handle , screwed both ends for iron pipe or unions complete all as specified and directed.
S&F 10ltrs capacity flushing cistern PVC low level valve less, symphonic action type flushing cistern, dual flush, white with inlet, ball valve, float and handle including brackets and 32 mm flush pipe of polyethylene complete all as specified and directed.
S&F CP soap dish complete all as specified and directed. Make Prayag/Parryware/Seiko
S&F brass chromium plated tubular towel rail 20 mm dia 'D' type 60 cm long between flanges complete all as specified and directed. Make:Hindware/ Prayag or equivalent as approved by the GE)
S&F Vitreous china wash down water closet pan (pedestal pattern), white/coloured (excluding flushing cistren and flush pipe) including connection to drain or outgoing pipe and to flushing pipe, anti-syphonage pipe etc, incl Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified.
S&F shower rose chromium plated with or without swivel joints 125 mm dia complete all as specified and directed.Make:Hindware/Prayag or other equilant as approved by the GE
Supply only Pillar taps, cast copper alloy , with capstan heads, chromium plated , Fancy type screwed down for 15 mm bore pipe,high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe ; complete all as specified and directed.
S&F in repair vitreous china WHB white flat back size 580x450mm including Supplied and fixed angle iron brackets, C.P pillar tap fency type 01 No 15mm bore, CP waste coupling, 32mm dia and PVC waste pipe 32mm dia and PVC connection 450mm long high pressure complete all as specified & directed. . Hindware/Prayag/Parryware/Cera as approved by the GE
M&L for Mild steel galvanised water tubing , medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors for the following bore of pipes complete all as specified and directed..
S&F PVC connections 15mm size with brass chek nuts of length 450mm complete all as specified and as directed.
M&L for 110mm bore PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps or laid in trenches complete all as specified & directed. Make:Prince/Supreme/Finolex/Kisan as approved by the GE
M&L for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls including PVC clamps fixed to wall properly or laid in trenches complete all as specified & directed. Make:Prince/Supreme/Finolex/Kisan as approved by the GE
S&F PVC (SWR) bends 110 mm bore of any radius provided with access door all as specified & directed. Make:Prince/Supreme/Finolex/Kisan as approved by the GE
S&F PVC (SWR) bends 75 mm bore of any radius all as specified & directed.Make:Prince/Supreme/Finolex/Kisan as approved by the GE
S&F PVC (SWR) junction single (single T) equal or unequal 110mm bore provided with access door all as specified & directed. Make:Prince/ Supreme/ Finolex/Kisan as approved by the GE
S&F PVC (SWR) junction single (single T) equal or unequal 75mm bore provided with access door all as specified & directed. Make:Prince/ Supreme/ Finolex/Kisan as approved by the GE
S&F 110 mm bore PVC (SWR) vent cowl all as specified and directed. Make:Prince/Supreme/ Finolex/ Kisan as approved by the GE
S&F 75 mm dia outlet PVC (SWR) floor trap plain with steel grating including jointing with solvent cement all as specified and directed .Make:Prince/Supreme/Finolex/Kisan as approved by the GE
S&F pressed steel frames for doors of size (105x60) mm made of 1.25mm thick mild steel sheet for door with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., cwith and including PCC(1:3:6) type B0 using 12.5 mm graded stone aggregate filling in hollow portion of frame complete all as specifid and as directed.
S&F 30 mm thick Factory made moulded PVC door shutter of Make - Rajshri Model Bluesky or other equilent approved make, wood free consisting of frame made out of M.S. tubes of 19 guage thickness and size of 20mm x 40mm for stiles as well as top, bottom & lock rails. M.S. frame shall have a coat of metal primer of approved make and manufacturer. The inside panel shall consist of 20mm thick multi chamber hollow PVC section of 1mm wall thickness, bonded using solvent cement / cyanoacrylate adhesive with 5mm thick moulded PVC sheet of density 600 kg/cum manufactured with 2,4,6 raised panel design in prelaminated colours after routing the moulded design on one side of inside panel 5mm prelam PVC sheet to be pasted using solvent cement / cyanoacrylate adhesive on other side of hollow PVC section. All the four edges of panel to be sealed with lipping of 10mm thick & 20 mm wide PVC sheet batten made by sticking 02 Nos regid foam PVC sheets of 5mm thickness using PVC solvent cement adhesive. Door edge lipping to be painted with PVC ink of matching colour of plain / prelam moulded PVC sheet of door 20mm thick (5mm x 04 Nos) thick PVC sheet to be given for lock provision at lock height complete all as specified and directed.
S&F Aluminium, anodised, barrel tower bolts of extruded section and fixed, 200 mm length of bolt complete all as specified.
S&F 300 mm long Aluminium alloy. Anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified.
S&F Aluminium alloy handles, cast type anodised, 150mm long all as specified.
S&F Mild steel framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified.
S&F Galvanised steel wire cloth, 0.56 mm nominal dia. of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified.
M&L Reinforced concrete pipes, class NP3 , 150 mm bore, laid and jointed complete with collars all as specified.
M&L Plain cement Concrete ( 1:3:6) type C2 bed to 150 mm bore drain pipes including packing under , and haunching against the sides of pipes after they are laid and tested ;in complete all as specified.
M&L Sand filling under floors/ pathways or in foundations including watering and consolidation complete all as specified.
S & F powder coated aluminium frame/shutters for windows, ventilators sliding/openable etc including joining cleat for fixing, locking arrangement, rubber beading, screws, etc. complete all as specified. Make: JINDAL/HINDALCO/ INDALCO. Note :- (i) Glazing and wire mesh shall be measured and paid separetely for supply only as the labour element included in this item. (ii) Item shall be paid as per weight of aluminium section. (iii) the rete quoted shall be inclusive of the cost of neoprene beading, glazing pin. screws and powder coated fittings such as locking arrangement etc as required, which shall not be measured for arriving the weight. (iv) The rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing.
Supply only 4 mm thick sheet glass figured glass pin head type and glazing with oil putty or fixing rubber gasket with aluminium frame in squares not exc 0.5 sqm in each pane complete all as specified and directed.
S&F Rotational moulded poly-ethylene multilayer (three layers) water storage tanks ( cylinderical vertical with closed top ), white colour, 1000 litres capacity ,hoisted and fixed in position including 25mm dia brass float valve assembly complete all as specified and directed.
Supply only Ball Bearing for rolling shutters complete all as specified.
S&F Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified.
S&F Steel rolling shutters with 1.25 mm thick laths , without ball bearing , as specified including top cover , anchoring rod, hasp and staple and one shop coat of primer;erected in position as indicated, complete ; push pull or manual type complete all as specified
M&L for 10 mm thick screed bed or bedding layer in CM 1:3 mixed with liquid water proofing compound using as per manufacturer's instrutions on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed Note :- Water proofing compound shall be measured and paid separately)
M&L for Providing water proofing treatment over cleaned roof surface with super thermo APP modified water proofing memberane comprising of the following for Non approachable roofs- (i) Cleaning and sweeping and washing down with water to remove all dust etc from plastered roof surfaces / walls and filling of crack with sealing compound etc (ii) Bituminous based primer conforming to IS: 3384 – 1965 at 0.3 Kg per Sqm (iii) One layer of super thermo APP modified water proofing memberane with non polyester reinforcement of any make.( M/s STP texsa ltd/Hyperplas memberane of M/S IWL India ltd/MS STPand Tikki Tar ltd). having minimum 3mm thick and minimum Weight @3.50Kg/Sqm , laid with gas torch and pasted on roof surfaces with roller as per manufacture insteructions. . The over laps shall be sealed by flame including vertical surface after cutting necessary grooves and making good with PCC gola 1:2:4 type- B1 etc adhere to bitumen all as per manufacturer's instructions. (iv) Applying a coat of aluminium paint @ 200 gm/sqm in two coats over polymeric membrene complete all as specified and directed at site.
Supply only liquid water proofing compound complete all as specified and directed.
M&L plain cement concrete type B1 (1:2:4) using 20 mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar band, copings, benching, covings, bed plates and like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary form work complete all as specified and directed.
Excavating in post holes in hard / dense soil ( or similar holes) each n exc 0.5 cu.m. getting out, returning,filling in and ramming earth or broken rubble mixed with earth around , in layer not exceeding 25 cm, watering and removing surplus soil to a distance n.exc 50 M complete all as specified.
M&L mild steel Hand rails, half round or other stock section or core for wooden hand rail straight portion , drilled and counter sunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire , etc.; flat iron fillets ( for securing wire mesh etc. including all necessary drilling , bolting or rivetting , etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L mild steel round bars 10 mm dia and over , cut to length , bent to shape required, including cranking, bending spirally for hooping ends for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.90 mm dia. complete all as specified of grade Fe-410-W ( Gde-E-250) quality -A or Fe 290 ( Gde-E-165) and as directed.
Fixing only chain link fencing including line wires, any mesh size and type to any type of standards , rails, straining bolts etc. including provision of binding wire complete all as specified.
Supplying only chain link fencing of MS galvanised 3.8 mm dia including line wires of same dia , of mesh 50mmx 50mm size complete all as specified.
M&L Mild steel Galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts , including,securing or tying at crossings with and Provision of galvanised mild steel wire , staples or steel pins etc. as directed ( each line wire to be measured)
M&L Mild screw bolts ( Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends , each screwed end to be fitted with washers and one hexagonal or square nut , exc 5 but n exc 10cm long and 12 mm dia. of shank complete all as specified.
M&L preparation of new steel surfaces of any description not otherwise described not excd 10 cm width or girth and applying two coats of synthetic enamelled paint over one coat of red oxide Zinc chrome primer complete all as specified.
M&L for 10 mm thick rendering in CM (1:4) on fair faces of brick work, surfaces finished even and smooth without using extra cement complete all as sprcified and as directed.
S & F Rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces,etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conform to Fe 290-0 Gde E-165 all as specified and directed
M&L mild steel Bands, straps, supports or stays for rainwater , fan clamps Ventilating pipes, including bolts , if required; hooks ( stay), heavy, for large gates; hook and pintol hanges; large hasps and staples ; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters ; knee piece inserts; two way and three ways straps , plate washers and similar small articles conforming to Fe-290 Gde -E-165 complete all as specified.
M&L 75mm thick, plain cement concrete 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in sub base complete all as specified.
M&L plain cement concrete type B1 ( 1:2:4) using 20 mm graded stone aggregate as in providing cement concrete in roof kerbs or mud stops, rounded or cmamfered on edges complete all as specified.
M&L Cement concrete (1:3:6) TypeC-2 using 40mm graded stone aggregate as in surface channel and drain complete all as specified and directed at site
M&L Extra for forming fair finished drain or channel 30cm inner girth in cement concrete,using extra cement,including forms,mitred/stopped ends etc complete all as specified and directed at site.
M&L precast cement concrete type B-1 (1:2:4) using 20mm graded aggregate as in man hole cover slabs, shelves, and similar work set in CM (1:4).complete all as specified and directed.
M&L Reinforced concrete pipes, class NP2 , 450 mm bore, laid and jointed complete with collars all as specified.
M&L for point wiring with 1.5 Sq mm single core PVC insulated and sheathed FRLS copper multi stranded conductor in and including Concealed PVC conduit of size 20/25mm ISI marked inclusive of tees ,bend ,elbows etc upto and including sunk in Anodized pressed steel box for housing switch socket etc with white laminated 3 mm thick sheet cover of suitable size complete including PVC insulated multi stranded FRLS copper conductor 1.5 Sq mm as earth wire to common earth dolly for connection to ceiling rose to earth terminal incl cutting, chasses and making good disturbed surface to match with existing finish with plaster for One light /Fan point controlled by one all as specified and directed at site.
All as per ser item No . 133 here-in-before but one 3 pin socket out let 5 Amps on the same board all as specified and directed at site.
All as per Srl items No.133 here-in-before but point wiring with 4 Sqmm for 15 Amp socket out let with 2.5 sqmm earth continuity all as specified and directed at site.
S&F Switch Piano type single pole 5 amp 230 v complete all as specified and directed at site.
S&F socket outlet 2 in 1 , 5 pin, 5 amp complete all as specified and directed at site.]
S&F Switch Piano type single pole 15 amp 230 v complete all as specified and directed at site.
S&F socket outlet 2 in 1 , 6 pin,5 and 15 amp complete all as specified and directed at site.
S&F ceiling rose surface type all as specified and directed at site.Make : Havells Cat Part No. AHLHXCW000 or equivalent as per list of makes as approved by the GE.
S&Fixing stepped type electronic fan regulator flushType complete all as specified and directed at site.Make : Anchor Cat Part No. 14502 or equivalent as per list of makes as approved by the GE
M&L for sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in concealed suitable size of PVC Conduit as required with 2x6.0 sq mm+1x4.0 sqmm earth wire complete all as specified and directed at site.
S & F of LED light fitting with single LED tube ,1x20W, 230V .industrial batten type, powder coated top cover, ( complete with all accessories internally preired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make : HPL cat part No : HLPT51820CGOW or equivalent in Havells, Bajaj, Philips as approved by the GE.
S & F Ceiling fan 1400 sweep completed with electronic type regulator, capacitor canopy, fan hook and down rod including flexible twin core copper conductor (23/0.76) with provision from ceiling rose/connector to fan, BEE 5 Star rated, complete all as specified and directed.
Supplying , installing, testing, commissioning exhaust fan, heavy duty, 300 mm sweep, 230 Volts, AC , 50 Hz, 4 poles with mild steel louvers and other accessories, making holes in walls to the required shape and size, grouting Mild steel bolts in walls of length not less than 125 mm and 12 mm dia. with nuts and washers, making good disturbed surfaces in cement and sand mortar 1:4, and matching exposed surfaces to match with the existing, removing dismantled brick work /rubbish to a distance not exceeding 50 M complete all as specified .
Supplying and fixing 12 way Double way, single pole and neutral, prewired.sheet steel MCB distribution board, 240 volts, on surface/ recess, complete with 200 amp bus bars, neutral bus bar, earth bar, din-bar, detachable gland plate , interconnections including phosphatized and powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) door
Supplying & fixing 5 amps to 32 amps rating 240 volts 'C' curve single pole Miniature Circuit Breaker suitable for Power loads in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying & Fixing of 32 Amps DP MCB 240 volts, C curve 10KA Miniature Circuit Breaker in the existing MCB DB complete with connections, testing and commissioning etc. as required.
M&L for LED street light luminaries of 70/72/75 watt white light with lense pressure die cast housing with epoxy powder coated dark graphite grey colour finish finish prismatic polycarbonated cover with individual LED lenses incl surge protection device including fixing brackets made out of 40mm dia medium grade GI pipe 1 mtr long bent to shape and size fixed on location using clamps made to shape incl and necessary wiring with 3Cx2.5 sqmm from DB upto light point complete all as specified and directed by Engr-in-charge. MAKE: HPL Cat No :-HPLLEDSL7260E/ PHILIPS/ WIPRO/CG
Drilling of Trial bore hole of suitable dia, with rotary/DTH/percussion/reverse rotary circulation or direct circulation method or combination of both by using power rig for housing of 200mm nominal bore of the casing depth from ground level to 65 mtr below ground level, incl transportation of power rig machine at GC Area. Lowering the MS ERW Pipe will paid separately :- for one borewell as per recommendation of CGWB. Note :- (i) Sample of strata shall be collected for every 3 mtrs interval or where ever is a change in strata and the sample shall be preserved in a suitable strata sample box (as directed and specified). The cost of strata sample box will be paid separately. (ii) The result of drilling mentioning total depth drilled, casing length lowered, depth at which fractures encountered, their corresponding yield shall be supported with a bore well chart after completion of the drilling. The cost of for the test is deemed to be included in the unit rate.
Supply, lowering and fixing in position 200mm nominal bore ERW heavy duty MS housing pipe as per IS 3589 of 6mm wall thickness welded joints with MS ring around the pipes with MS flat iron 50mmx6mm complete all as specified and directed . Make : Jindal/TATA
Same as above item Ser No 151 but slotted pipe 200mm dia including socket conforming to IS:8110
Developing of the tubewell by means of high velocity jetting together with air compressor having capacity 400 PSI air compressor until clear water is obtained incl transportation, erection and dismantling of air compressor complete all as specified in IS-11189-1985 and as directed. Note: - Cost of fuel/oil to be included in unit rate
M&L Conducting yield test with 'V' notch method for consecutive by providing air compressure suitable capacity of pump set and fixing the optimum discharge. The cost of fuel for the test is deemed to be included in the unit rate.
Supply and fixing of strata box for collecting sample of strata in different layers of bore well complete all as specified and directed
Supply and fixing column pipe holding clamp for 50mm dia MS pipe with 2 Nos, 12mm dia bolts and nuts galvanised MS flat 50mm x 10mm including drilling hole of suitable size and painting two coats of synthetic enamelled paint over red oxide primer including borewell cap of suitable size etc complete all as specified and directed by Engr-in-charge.
S&F and commissioning of submersible pump 7.5 HP/5.5KW of electric driven 415 volts TP, pump discharge Q 18m3/hr, head 69 mtr, 2900RPM, cable connection complete all as specified and directed by Engr-in-charge. Model No:- UQD 212/07+UMAI 150 6/22 of KSB or equivalent in Kirloskar
Supply and fixing of standard automatic star delta submersible pump starter suitable for 5.5 KW submersible electric motor relay 9-13 Amp complete all as specified and directed incl channels fixing of wall. Make : Havells/Schneider
S&F, commissioning of three core flat cabLe with bare bunched copper conductor insulated with PVC insulated multi stranded submersible copper cable upto 1100 volts 6 Sqmm with proper copper thimbling end to end connection all as specified and directed. Make : Finolex, Havells or equivalent
Material & Labour for lowering Heavy grade C Clss GI column pipe of 50 mm dia as per IS 1239 part-1(2004) for 3 Mtr long with flanged ends including provisioning of GI flanged heavy duty, flanged jointing with jointing material by welding, bolts, nuts, washers and rubber/ fibre board gasket all as directed.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100v grade of cross sectional area 25 Sqmm x 3.5 Core laid in trench/duct/drawn through conduit/fixed to wall with clamp end to end connection with proper thimbling complete all as specified and directed
Supply & laying of GI tubing "Medium grade" with all fitting like union, socket, reducer, elbow etc laid in trenches/floor of the 80mm dia complete including cutting to suitable size and jointing as per site requirement all etc complete as specified and directed by Engr-in-charge.
S&F and testing and commissioning globe valve, conforming to IS 9338, of 80mm dia sizes complete as directed by Engr-in-charge
Supply, laying, testing and commissioning of DI pipe of 150mm dia bore with spigot and socket ends conforming to IS:8329/2000 centrifugally cast class K-7 suitable for push on joint including rubber gasket jointing with cement mortar lining inside the pipe with outside zinc and bituminous coating laid in trenches/ on surface/ over masonry pillar and connection to old or new position complete all as directed.
Taking up CI water main (incl all fitting) with spigot & socket ends and lead joints incl burning out/tyton joint & recovering lead from pipe of 300 mm bore for relaying / rerouting of serviceable pipe after cleaning complete all as specified and directed by Engr-in-charge.
Supply, laying, testing and commissioning of DI pipe of 200mm dia bore with spigot and socket ends conforming to IS:8329/2000 centrifugally cast class K-7 suitable for push on joint including rubber gasket jointing with cement mortar lining inside the pipe with outside zinc and bituminous coating laid in trenches/ on surface/ over masonry pillar and connection to old or new position complete all as directed.
Supply, laying, testing and commissioning of DI pipe of 150mm dia bore with spigot and socket ends conforming to IS:8329/2000 centrifugally cast class K-9 suitable for push on joint including rubber gasket jointing with cement mortar lining inside the pipe with outside zinc and bituminous coating laid in trenches/ on surface/ over masonry pillar and connection to old or new position complete all as directed.
M&L for Ductile iron fitting for spigot socket pipe such as bends (any type, radius and angle) tapers any type (straight, bend increasing, decreasing or double socket etc). Tee pieces single branch. "Y" junction, double branch, cross (All socket or socket and spigot) collars, caps & plugs 150 mm to 300 mm dia bore including cutting and jointing old/ new positions as specified and directed by Engr-in-charge.
Cutting cast iron/DI pipes and reducing to required length before laying, in position for insertion of new tees, branches, etc up to 150 dia bore.
Cutting cast iron/DI pipes and reducing to required length before laying, in position for insertion of new tees, branches, etc up to 200 dia bore.
Cutting cast iron/DI pipes and reducing to required length before laying, in position for insertion of new tees, branches, etc up to 250 dia bore.
Material & Labour Cutting out concrete blocks, slabs, brick-work or stone masonry (in alternate course), forming toothings for and bonding new work in mortar into old work,including new materials entering old wall for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate and Set in cement mortar 1:4 including making good disturbed surface to match with existing complete all as specified and directed.
S&F Cast Iron sluice valve duly ISI Marked with iron wheel head both end flanged , Brass spindle, non rising type complete with Neoprene rubber gasket, nuts, bolts and washers etc. complete all as specified and directed of following bore and presssure rating.
80 mm bore , PN 1.6
100 mm bore , PN 1.6
150 mm bore , PN 1.6
200 mm bore , PN 1.6
S & F and testing and comissioning of CI non return valve (ISI -5312) suitable for 150 mm bore pipe heavy duty both end flanged of pressure rating PN 1.6 and jointing with joint with rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers complete all as specified.
M & L for Construction of brick machinery valve pit chamber of size 900x900x500 mm in any type soil incl necessary excavation and earth work, PCC 1:4:8 type D2- in foundation concrete, brick work in cement mortar 1:4, coping with PCC 1:2:4 type B -1, angle iron frame 50x50x6 mm MS Sheet cover(6 mm thick) with locking arrangement and having FRP coating of 2mm thick on both inside and outside surface incl cement plaster on internal surface in cement mortar 1:4 complete as on shown on TD No CEJZ/TD/819/91 sheet1/1 dated 16.04.91 and as directed.
Supply, fix, testing and commissioning of Chlorine solution preparation tank FRP construction of capacity 170 Ltrs size with FRP solution tank with led, port hole, inlet/outlet/drain connection, level gauge etc and fitted with speed reducing motor & SS-316 agitator combined with dosing tank with lid, port hole, inlet/outlet/drain connection, level gauage etc complete as specified and directed. Make :- RMCO, Model :- CDS-1015 or other equilent make and model as approved by the GE.
M&L for CPVC pipes of SDR 11 and Plain CPVC SDR 11 fittings fixed complete to walls, ceilings or laid in floors etc as per IS 15778 , of size 20mm dia including cutting and jointing with adhesive to required length as per ground requirement all as specified and directed .
Supply, fixing and testing of 20mm dia PP-R ball valves (brass insert) complete as specified and directed.
Supply, installation, testing and commissioning of foot valve of size 150mm bore pipe, flanged type confirming to IS:4038, including jointing materials such as rubber fibre board packing ring and nuts, bolts and washers of suitable size, complete all as specified and as directed .
Supply, installation, testing and commissioning of mild steel pipe conforming to IS 1239 Part-I of 2004, 150mm bore flanged type class 'C' for making header including fabrication and bends fitting of required size at pump house and synthetic enamel painting two coat complete all as specified and as directed .
Supply, installation, testing and commissioning of mild steel pipe conforming to IS 1239 Part-I of 2004, 100mm bore flanged type class 'C' for making header including fabrication and bends fitting of required size at pump house and synthetic enamel painting two coat complete all as specified and as directed .
Supply, installation, testing and commissioning of Non return sluice valve of size 100mm bore pipe flanged type confirming IS-5313, including jointing material such as rubber fibre board packing ring and nuts, bolts and washers fo suitable size, complete all as specified and directed .
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100v grade of cross sectional area 95 Sqmm x 3.5 Core laid in trench/duct/drawn through GI pipe/road crossing/fixed to wall with clamp in wall end to end connection proper thimbling complete all as specified and directed
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thisckness shall only be considered for payment.
Material and labour for 50 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, incl taking out old pipe complete all as specified and directed including clamps, nut bolt and washers.
M&L Boring under road /foot path by pneumatic tools or manually for inserting of 50mm dia GI tubing for drawing UG cable,with proper finishing complete all as specified and directed.
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Supply, installation, testing and commissioning of Servo voltage stablizer Micro controlled digital type with by pass system capacity 30 KVA 3 phase 4 wire copper wound input voltage 300 to 480 Volts output volt 415 V 50Hz, cooling- Oil cooled including transformer oil correction speed 10-20 v/sec. The operation is auto with manual, display digital type, quoted rates include all necessary connections complete all as specified TI 04 of 2011, cable gland as directed by Engineer-in- Charge. (Make:-AE/ APLAB/ Sinetrac/ Brentford/ Volina/ Sai Electricals/ ITE/ Powerware as approved.)
Supply, installation, testing and commissioning of on load change over switch of capacity 100 Amps, 4 pole, 415 Volt, front operated in sheet metal enclosure complete all as specified and as directed. Make- HPL/Havells/Legrand/L&T/ ABB/Indoasian
Supply installation, commissioning and testing of LT Feeder Pillar, indoor type, floor mounted, weather vermin proof factory made, CPRI approved, facricated out of 3.15mm thick mild steel sheet mounted, on frame of mild steel angle iron 40 mm x 40 mm x 6 mm, 45 cms above the ground level duly supported with mild steel angle iron 50 mm x 50 mm x 6 mm thick in PCC foundation (1:2:4), type B-I, using 20 mm graded crushed stone aggregate, LT panel shall be totally enclosed with front double door and rear opening with IP-54 protection as per IS/8623 duly powder coated for 433 volts, 3 phase, 4 wire having TPN copper bus bars suitable for 150 Amps load duly drilled holes for connections, RYB insulated with different colour code and sleeved insulators complete prewired and cable connection with copper conductor wire upto cooper bus bars including all incoming and outgoing cable connection with suitable size of lugs/gland complete al as specified and directed by Engr-in-Charge
(A) INCOMING: (i) 100 amps 4 pole MCCB , 16 KA breaking capacity with thermal adjustable setting-01 Nos Make: Schneider
(B) OUTGOING (i) 63 amps 4 pole,MCCB ,16 KA breaking capacity with thermal and magnetic adjustable setting-03 Nos Make: Schneider
(ii) 32 amps 4 pole,MCCB ,16 KA breaking capacity with thermal and magnetic adjustable setting-01 Nos Make: Schneider
(iii) 32 Amps DP MCB, 10 KA breaking capacity - 02 Nos
(iv) RYB indication lamp RYB -01 set.
(vii) Automatic Star delta starter suitable for 20 HP Centrifugal pump with phase corrector and phase preventer.-03 Nos make: Schneider
(C). Drawing of panel shall be got approved from GE before placing the order. (D). Any other items which are not mentioned above but are essential for smooth functioning shall also deemed to be included in the quoted rates
S&F for replacement of Post Top outdoor Luminairy ruby (clear) IP-65 spun aluminium landscape lumanary with high focus LED 25 watt Fitting 32 mm dia GI Pipe Medium grade 1 mtr lenght complete pressure die cast powder coated housing with PC diffuser necessary electric connection and repair of base by PCC for cable entry all as directed .as light source MAKE: HAVELLS cat No-RUBYPT25WLED75PSYMTOPC or equivalent in Havells/Bajaj/Philips/C&S
Supply and laying in trenches/laid in floor/duct/drawn through conduit XLPE insulated PVC bedded armoured heavy duty electric cable 1100V grade with aluminium conductor of cross sectional area 2 Core 6 Sqmm with proper thimbling end to end connection complete all as specified and directed by Engr-in-Charge
M&L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. Below ground level connecting to GI Strip 25X4 mm dia size by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe light grade, 15 mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded crushed stoned aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 25x25 x3mm with lughs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, test pont made out of phosphorous bronze with fixing arrangement, funnel, wiremesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified and testing on completion.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with 25x4 mm galvanised iron strip all etc complete as specified and directed by Engr-in-charge
Supply, installation, testing and commissioning of cable tray size 200mmx25mm ISI marked 16 swg (appx 1.6mm) MS/GI Hot dip powder coated perforated type cable trays with cover, supported byMS angle complete all as specified and directed by Engr-in-charge
Supply, installation, testing and commissioning of 10 sqmm 3 Core flat copper cable with bare bunched with voltage grade upto 1100 volts conforming to and marked with IS:694:1990 necessary connection with proper copper thimble complete all as specified and directed by Engr-in-charge
Supply, installation, testing and commissioning of centrifugal pump set including motor, electric driven, three phase AC, 415 volts, capacity 20 HP for 40 mtr head and 90 m3/hr discharge, CI impeller including plain cement concrete foundation and grouting with mild steel bolts complete all as specified and directed by Engr-in-charge. Model :- ETN 080-065-200 GGSCP1CGC201502B Make : KSB or equivalent in Kirloskar
Supply, installation, testing and commissioning of pressure gauge 4" dial and pressure rating 0-14 Kg ferrule type, made out of MS and brass insert all etc complete as specified and directed by Engr-in-charge
Supply, installation, testing and commissioning of FRP scale type conventional water level indicator for OHT and UG sump complete with FRP scale, MS fabricated scale holding frame, FRP/GI float, wire, float guide pipe, bracket & pulley, counter weight, indicator pin, all etc complete as specified and directed by Engr-in-charge
M/S ABHAY KUMAR AND BROTHERS
M/S SANJAY KUMAR YADAV
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .