Supply, wiring, testing & commissioning of FL Numbers 1400.00 point/ Lamp point/Fan point (loop wiring) with angular/ batten holder by FR PVC insulated and unsheathed single core, 1.5 sq mm multistranded copper cable to be drawn through rigid PVC conduit pipe not less than 20 mm dia medium gauge including bends, joints etc. from main line under PP shed and 1 sq mm single core FR PVC insulated and unsheathed copper wire for earth continuity without controlling switch under PP shed/FOB as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply, commissioning of Surface/Suspended mounted LED Trunking Batten 40 watt, extruded aluminum housing provided for efficient heat dissipation with polycarbonate diffuser & Built-In electronic driver. IP 54, CRI 80, THD(%) 10, CCT. 6500 K Power Factor 0.95, Operating temperature: -10 C to +50 C, Operating voltage range: 165 V - 270 V, Average life 50000 hours, LED lumen efficacy 145 lm/W with a viewing angle of 120, Powered by built-in electronic driver (SMPS based constant current supply) with Output Open/Short-circuit, Thermal fold back, 440V 8 Hrs protection, Surge protection 4 KV & others safety test as per IS:15885 Part 2/Sec 13. Havells Model No. ACETRUNKINGADVS40WLED865PSYMBOPCWHT.
Supply, wiring, testing & commissioning of Numbers 408.00 concealed point wiring by FR PVC insulated and unsheathed 1.5 sq mm, single core multi strand copper wire with earth continuity wire by PVC insulated and unsheathed 1 sq mm , single core multi strand copper wire concealed on wall through PVC rigid conduit pipe of dia not less than 20 mm dia heavy duty including all types of joints and bends as required, complete with 6 amps flush type controlling modular switch to be mounted on modular GI inner plate and modular mounting frame of suitable module as per requirement complete to be concealed in wall as per instruction of Engineer Incharge at site. Existing wall should be cut and re-mended to original finish by contractor's own material. (a) FL Point/LED Tube Point/LED Recess Light Point/Wall Mounted Bracket Fan Point/LED Mirror Light Point with c/rose
(b) Lamp Point with angle holder
(c) Fan point with c/rose and 5 step fan Numbers 120.00 regulator 2 M
(d) Exhaust fan point with c/rose
Supply, wiring, testing & commissioning of Numbers 160.00 c o n c e a l e d plug point on separate board complete with 2 x 6 Amp modular socket and 6/10 amps modular switch to be mounted on modular GI inner plate 6M and 6M modular mounting frame with GI box to be concealed in wall as per instruction of Engineer Incharge at site. Existing wall should be cut and re-mended to original finish by contractor's own material.
Supply, wiring, testing & commissioning of Numbers 120.00 concealed 6/16 amps power plug point on separate board complete with modular 16 amps switch (with indicator) and 6/16 amps 3 pin combined shuttered socket to be mounted on modular GI inner plate 4M or suitable size with modular mounting frame to be concealed in wall as per instruction of Engineer Incharge at Site.
Supply, fixing, connection & testing of 20 watt Numbers 1000.00 Inverter LED batten with Lithium Ion battery. 3 Step Dimming. Upto 10 hours Battery backup. Charging time 8 hours-10 hours as per instruction of Engineer Incharge at Site.
Supply, installation, testing & commissioning of Numbers 160.00 Surface/Recessed LED luminaire with slim line CRCA sheet metal body, square type, (System wattage-18 Watt, Nominal system efficacy >= 120 lm/watt) suitable for 600 x 600 mm modular ceiling as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply and testing of wall mounted bracket fan Numbers 400 mm sweep complete with all accessories to be fixed on wall by suitable fixing arrangement including connection by 2 core, 1.5 sqmm PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable as per instruction of Engineer Incharge at Site.
Supply, commissioning of surface mounting sleek LED mirror light 5 W or 7 W, IP 20, 1 ft version powder coated CRCA housing, high output diffuser including suitable fixing arrangement on surface as per instruction of Engineer incharge at site.
Supply, fixing & testing and commissioning of Numbers LED 12 W B22 CDL INVERTER BULB V2 as per instruction of Engineer Incharge at Site.
Supply, installation, testing & commissioning of Numbers 300 mm sweep (metallic) heavy duty exhaust fan, 1400 RPM complete with fixing on wall by suitable size bolts & nuts grouted on wall as per instruction of Engineer incharge at site.
Supply, wiring & testing of main wire by 2.5 sq Metre mm, Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts and earth continuity wire by 1.0 sq mm FR-LSH PVC Insulated Industrial Grade Copper Conductor Conforming to IS: 694 concealed in wall through PVC rigid conduit pipe not less than 20 mm dia as per instruction of Engineer incharge at site.
Supply, wiring & testing of main wire by 4 sq Metre mm, Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts and earth continuity wire by 1.0 sq mm FR-LSH PVC Insulated Industrial Grade Copper Conductor Conforming to IS: 694 concealed in wall through PVC rigid conduit pipe not less than 20 mm dia as per instruction of Engineer incharge at site.
Supply, wiring & testing of main wire by 6 sq Metre mm, Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts and earth continuity wire by 1.0 sq mm FR-LSH PVC Insulated Industrial Grade Copper Conductor Conforming to IS: 694 through PVC rigid conduit pipe/polythene pipe not less than 20 mm dia as per instruction of Engineer incharge at site.
Supply, installation, testing & commissioning of Numbers modular power unit complete with 32 Amp mini MCB DP "C" series 3kA , 25 amps starter, 25 Amp Socket and 25 Amp plug to be mounted on 6 module GI box, 6 module combined plate concealed on wall and wiring by 6 sq mm, Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts with earth coninuity wire by 1 sq mm copper cable Conforming to IS: 694 to be drawn through Rigid PVC conduit pipe not less than 20 mm dia as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply, installation, testing & commissioning of Numbers Inverter Split Air Conditioners 1.5 Ton, (BEE star rating-5 star, Coil material-Copper, Echo-friendly refrigerant, Nominal cooling capacity in Ton / (kcal/hr)-1.5 Ton / 4500 kcal/hr) with all accessories as per OEM suitable for operation on 230V AC ,single phase, 50 Hz as per instruction of Engineer incharge at site. Re- mending work should be done after installation of RAC. (with 1 pair outdoor wall stand) (Industrial AC/Heavyduty AC)
Supply, erection, testing & commissioning of 16 Set mt long High Mast Tower with 8 nos. x 250 watt LED luminaries in symmetrical arrangement complete with all accessories (Double drum winch, SS wire rope, integral power tool motor, head frame, junction box, foundation bolt, LED aviation light, Fedder pillar with single dial timer & raising lowering mechanism etc.) including shallow foundation with M20 grade concrete etc. as per instruction of Engineer Incharge at Site.
Supply, erection, testing & commissioning of 12 Set mt long High Mast Tower with 8 nos. x 150 watt LED luminaries in symmetrical arrangement complete with all accessories (Double drum winch, SS wire rope, integral power tool motor, head frame, junction box, foundation bolt, LED aviation light, Fedder pillar with single dial timer & raising lowering mechanism etc.) including shallow foundation with M20 grade concrete etc. as per instruction of Engineer Incharge at Site.
Supply, installation, testing & commissioning of Numbers 120 watt energy saving, environment friendly & robust Highbay LED with PDC housing suitable for ceiling (Surface/Suspended) mounting with system efficacy upto 150 lm/W as per instruction of Engineer Incharge at Site.
Supply & testing of GI octagonal pole 6 mt long Numbers 120.00 with foundation bolt, loop box of bakelite sheet with one 6A SP MCB and 16 sq mm stud type connector etc. The octagonal pole shall be hot dip galvanized in single dip. Technical specification of pole as following:- Height - 6 mt Top dia (A/F) - 70 mm Bottom dia (A/F) - 130 mm Sheet thickness - 3 mm Base plate (L x B x T) - (200 x 200 x 12) mm Foundation Bolt size (no.x dia) - 4 x 20 dia mm Pitch Circle Dia (PCD) - 200 mm Bolt length - 600 mm Projected Bolt Length - 100 mm .
Supply & fixing of 1 mtr GI Single arm bracket Numbers 120.00 (header) and holder with Nut & bolt as per instruction of Engineer incharge at site.
Erection of Rail/Tubular/Octagonal pole to 1/5 th Numbers 120.00 of its height with CC foundation from base block (30 cm x 30 cm x 15 cm) including digging & refilling of earth to a height of 30 cm above ground level as per drawing no.CEE/OH@47'40@FGA) in ratio 1:3:6 by cement sand & Chips 19 mm & down including excavation of earth.
Supply, installation, testing & commissioning of Numbers 120.00 90 Watt LED street light with pressure die-cast housing and toughened glass and individual LEDs with secondary lens optics for City Road application withIP66 ingress protection. 4kV inbuilt and 10kV external surge protecton with Top opening driver cover for easy maintenance as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply, installation, testing & commissioning of Numbers 150 Watt LED Street Light made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK08. as per instruction of Engineer incharge at site.
Supply, installation, testing & commissioning of Numbers 30 W FLAIR PRO is All-in-One Solar Streetlight having compact and fully integrated design with intelligent features includes a built-in Solar Panel, Lithium Ferro Phosphate (LiFePO4) Battery, Charge Controller and Motion Sensor as per instruction of Engineer Incharge at Site.
Supply, installation, testing & commissioning of Numbers 45 W FLAIR PRO is All-in-One Solar Streetlight having compact and fully integrated design with intelligent features includes a built-in Solar Panel, Lithium Ferro Phosphate (LiFePO4) Battery, Charge Controller and Motion Sensor as per instruction of Engineer Incharge at Site.
Supply, Installing, Testing & Commissioning of Numbers High Volume Low Speed (HVLS) FAN, 3 Phase, 1.2 KW , 20 ft. Diameter, 6 (six) Blade with Control Panel and all acessories as per instruction of Engineer Incharge at Site.
Supply, installation, commissioning & testing of Square LED indication station name board (Length of Foot board will be as per proportion of letter so that all the 4 side of the board will have extra space) with channel letters with 3.75 ft. in lenght with suitable widen and 4 mm projection size which inside ACP board (Brand- ALUDECOR, category- AL 33 series exterior & thikness-3 mm) with acrylic face on front and having Sumsung 5630 LED's (Shape- Lens type, operating voltage- 12 V DC, carring current-80 mA, power Dissipation- 0.96 watt, working hours-50000, case material- ABS ,protection-IP68) inside for illumination letters in English, Hindi, Bengali or regional language complete with all materials including provision of erection structure made of MS angle/channel/flat duly painted with aluminium paint over a coat of red oxide primer with CC foundation (1:3:6) of cement, sand and stone chips as required at site and as per instruction of Egnineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Design, manufacture, display of wall /hanging / Square floor mounting type LED illuminated sign / Foot direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 mm thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. (Signage Board should as per Railway Board Letter No. 2023/SD-II/22/07/02 Date. 15.05.2023)
Erection and installation of wall / hanging / floor Square mounting type LED illuminated sign / direction Foot boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text/graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 mm thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. (Signage Board should as per Railway Board Letter No. 2023/SD- II/22/07/02 Date. 15.05.2023)
Supply, installation, testing & commissioning of Numbers Pure Sine Wave 2400 VA Inverter with Integrated 2560 WH LiFePO4 Lithium-Ion Battery as per instruction of Engineer Incharge at Site.
Supply & erection of Lightning Protection Set System Complete Set with Supply of all accessories, 25 Meters Radius coverage as per instruction of Engineer Incharge at Site.
Supply & erection of Lightning Protection Set System Complete Set with Supply of all accessories, 55 Meters Radius coverage as per instruction of Engineer Incharge at Site.
Supply & erection of Lightning Protection Set System Complete Set with Supply of all accessories, 120 Meters Radius coverage as per instruction of Engineer Incharge at Site.
Supply and commissioning of Monitoring Device Set as per instruction of Engineer Incharge at Site.
Uprooting/Dismantling of HT/LT Rail Pole/Tubular Numbers Pole/Octagonal Pole without damaging the pole by excavation of earth & refilling of the excavated place with soil as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Loading, unloading and Carrying of HT/LT Rail Numbers Pole/Tubular Pole/Octagonal Pole from site to SSE's store by contractor own arrangement.
Horizontal machine boring of 300 mm dia hole Metre across track/Road/High drain etc. at a depth of 1.0 mtr below of ground level with suitable boring instruments & neessary arrangement and as per technical procedure.
Supply, laying, commissioning & testing of CI Metre Pipe 200 mm dia Class LA type (IS 1536-2001) to be laid partly along the pole and partly through ground under railway track/road in cable trench for protection of cable with suitable fixing arrangement by MS clamp, nut,bolt,washer etc.as per instruction of Engineer incharge at site.
Supply, fixing, testing & commissioning of IP Numbers 66/67 thermoplastic cable junction box / loop box of size (300 x 450 x 170) mm with knockouts & 04 nos terminals as per instruction of Engineer Incharge at Site.
Supply, fixing, testing & commissioning of IP Numbers 66/67 thermoplastic cable junction box / loop box of size (210 x 310 x 116) mm with knockouts & 04 nos terminals as per instruction of Engineer incharge at site.
Installation & Commissioning of different Numbers 150.00 capacity Flood Light/Street Light as per instruction of Engineer Incharge at Site. (Flood Light/Street Light will be supplied by Railway)
Supply & Erection of earth by 50 mm dia 3 Mtrs. Numbers long (3.6 mm thickness) GI pipe, 32x6 mm GI strip- 5 Mtrs, GI nuts, bolts including masonry materials for earthing pit, salt, charcoal, soldered end terminal etc. and construction of earth pit covered with RCC cover slab12.7 mm thickness and watering pipe as per Drg. No.- PCEE/ELG/DRG/2024/1 Date:- 30.09.2024 and as per instruction of Engineer Incharge at site.
(a) Supply, installation, testing & commissioning Set of oudoor type weather proof sheded feeder pillar box of suitable size made of powder coated 14 SWG MS/CRCA sheet, angle, flat etc. The feeder pillar box four legs should be grounted on CC foundation (1:3:6). Cable entry should have PVC glands. Feeder pillar box should have double door system with locking arrangement with fixing of rubber gasket for protection of entry of dust and water alongwith supply and fixing of following MCCB as per instruction of Engineer Incharge at site.
(b) MCCB FP 63 amps, 25 kA, Ics=100% Icu
(c) Copper bus bar 100 amps made of Set electrolytic grade copper consisting of 4 bars ( 3 Ph and Neutral ) ( Bus bar should have insulation cover)
(d) Supply, installation and testing of Astro Set (Analog) time switch with 3 pole 63 amp contractor and suitable thermoplastic box and fitted on mounting plate/DIN rail. KATIHAR DIVISION-ELECTRICAL/N F RLY
(a) Supply, installation, testing & commissioning Set of 12 way SPN Distribution Board, Flush/Surface mounting, IP 43 grade protection with copper bus bar, fully shrouded neutral bar, earth bar, cable ties, metal double door as per IS 8623 - III with supply and fixing of following RCBO/MCB's as per instruction of Engineer Incharge at Site.
(b) RCBO DP 32 Amp, 2 module Conforms to IEC Numbers 61009-1
(c) MCB DP 16-32 amps, 2 module, 10 kA, Numbers Conforms to IS/IEC 60898 - 1:2002
(d) MCB SP 6-32 amps, 1 module, 10 kA, C-curve Numbers 320.00 Conforms to IS/IEC 60898 - 1:2002
Laying, commissioning & testing of HT/LT Metre XLPE/PVC cable of different sizes partly along the pole and partly through ground in cable trench by excavation of ground below 1.5 mt from ground level with suitable fixing arrangement by MS clamp of size 50x6 mm and suitable size nut, bolt. Loading, Unloading & Carrying of cable to actual work site by contractor's own arrangement. (Aluminium Crimping Socket should be provided for each Cable Termination). (Cable will be supplied by Railway)
Excavation of cable trench (0.3 x 1.5) mtr below Metre ground level for laying of cable & refilling the soil after digging the earth as per instruction of Engineer incharge at site. Cable should be laid on bedding of height 75 mm sand at the bottom of trench, and covering it with additional sand of height 75 mm and thereafter protecing it by mean of bricks before refilling the soil as per IS 1255.
Cutting of Road/Pucca/Hard Soil below (0.3 x 1) Metre mt from ground level and make it good as original with supply & execution of CC work (1:3:6) as per instruction of Engineer incharge at site. Total 30870497.00
Item Breakup - B-PART-B (Under the Jurisdiction of SSE/Elect./P/IC/SGUJ)
Supply, wiring, testing & commissioning of FL Numbers 1400.00 point/ Lamp point/Fan point (loop wiring) with angular/ batten holder by FR PVC insulated and unsheathed single core, 1.5 sq mm multistranded copper cable to be drawn through rigid PVC conduit pipe not less than 20 mm dia medium gauge including bends, joints etc. from main line under PP shed and 1 sq mm single core FR PVC insulated and unsheathed copper wire for earth continuity without controlling switch under PP shed/FOB as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply, commissioning of Surface/Suspended mounted LED Trunking Batten 40 watt, extruded aluminum housing provided for efficient heat dissipation with polycarbonate diffuser & Built-In electronic driver. IP 54, CRI 80, THD(%) 10, CCT. 6500 K Power Factor 0.95, Operating temperature: -10 C to +50 C, Operating voltage range: 165 V - 270 V, Average life 50000 hours, LED lumen efficacy 145 lm/W with a viewing angle of 120, Powered by built-in electronic driver (SMPS based constant current supply) with Output Open/Short-circuit, Thermal fold back, 440V 8 Hrs protection, Surge protection 4 KV & others safety test as per IS:15885 Part 2/Sec 13. Havells Model No. ACETRUNKINGADVS40WLED865PSYMBOPCWHT.
Supply, wiring, testing & commissioning of Numbers 408.00 concealed point wiring by FR PVC insulated and unsheathed 1.5 sq mm, single core multi strand copper wire with earth continuity wire by PVC insulated and unsheathed 1 sq mm , single core multi strand copper wire concealed on wall through PVC rigid conduit pipe of dia not less than 20 mm dia heavy duty including all types of joints and bends as required, complete with 6 amps flush type controlling modular switch to be mounted on modular GI inner plate and modular mounting frame of suitable module as per requirement complete to be concealed in wall as per instruction of Engineer Incharge at site. Existing wall should be cut and re-mended to original finish by contractor's own material. (a) FL Point/LED Tube Point/LED Recess Light Point/Wall Mounted Bracket Fan Point/LED Mirror Light Point with c/rose
(b) Lamp Point with angle holder
(c) Fan point with c/rose and 5 step fan Numbers 120.00 regulator 2 M
(d) Exhaust fan point with c/rose
Supply, wiring, testing & commissioning of Numbers 160.00 c o n c e a l e d plug point on separate board complete with 2 x 6 Amp modular socket and 6/10 amps modular switch to be mounted on modular GI inner plate 6M and 6M modular mounting frame with GI box to be concealed in wall as per instruction of Engineer Incharge at site. Existing wall should be cut and re-mended to original finish by contractor's own material.
Supply, wiring, testing & commissioning of Numbers 120.00 concealed 6/16 amps power plug point on separate board complete with modular 16 amps switch (with indicator) and 6/16 amps 3 pin combined shuttered socket to be mounted on modular GI inner plate 4M or suitable size with modular mounting frame to be concealed in wall as per instruction of Engineer Incharge at Site.
Supply, fixing, connection & testing of 20 watt Numbers 1000.00 Inverter LED batten with Lithium Ion battery. 3 Step Dimming. Upto 10 hours Battery backup. Charging time 8 hours-10 hours as per instruction of Engineer Incharge at Site.
Supply, installation, testing & commissioning of Numbers 160.00 Surface/Recessed LED luminaire with slim line CRCA sheet metal body, square type, (System wattage-18 Watt, Nominal system efficacy >=120 lm/watt) suitable for 600 x 600 mm modular ceiling as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply and testing of wall mounted bracket fan Numbers 400 mm sweep complete with all accessories to be fixed on wall by suitable fixing arrangement including connection by 2 core, 1.5 sqmm PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable as per instruction of Engineer Incharge at Site.
Supply, commissioning of surface mounting sleek LED mirror light 5 W or 7 W, IP 20, 1 ft version powder coated CRCA housing, high output diffuser including suitable fixing arrangement on surface as per instruction of Engineer incharge at site.
Supply, fixing & testing and commissioning of Numbers LED 12 W B22 CDL INVERTER BULB V2 as per instruction of Engineer Incharge at Site.
Supply, installation, testing & commissioning of Numbers 300 mm sweep (metallic) heavy duty exhaust fan, 1400 RPM complete with fixing on wall by suitable size bolts & nuts grouted on wall as per instruction of Engineer incharge at site.
Supply, wiring & testing of main wire by 2.5 sq Metre mm, Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts and earth continuity wire by 1.0 sq mm FR-LSH PVC Insulated Industrial Grade Copper Conductor Conforming to IS: 694 concealed in wall through PVC rigid conduit pipe not less than 20 mm dia as per instruction of Engineer incharge at site.
Supply, wiring & testing of main wire by 4 sq Metre mm, Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts and earth continuity wire by 1.0 sq mm FR-LSH PVC Insulated Industrial Grade Copper Conductor Conforming to IS: 694 concealed in wall through PVC rigid conduit pipe not less than 20 mm dia as per instruction of Engineer incharge at site.
Supply, wiring & testing of main wire by 6 sq Metre mm, Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts and earth continuity wire by 1.0 sq mm FR-LSH PVC Insulated Industrial Grade Copper Conductor Conforming to IS: 694 through PVC rigid conduit pipe/polythene pipe not less than 20 mm dia as per instruction of Engineer incharge at site.
Supply, installation, testing & commissioning of Numbers modular power unit complete with 32 Amp mini MCB DP "C" series 3kA , 25 amps starter, 25 Amp Socket and 25 Amp plug to be mounted on 6 module GI box, 6 module combined plate concealed on wall and wiring by 6 sq mm, Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts with earth coninuity wire by 1 sq mm copper cable Conforming to IS: 694 to be drawn through Rigid PVC conduit pipe not less than 20 mm dia as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply, installation, testing & commissioning of Numbers Inverter Split Air Conditioners 1.5 Ton, (BEE star rating-5 star, Coil material-Copper, Echo-friendly refrigerant, Nominal cooling capacity in Ton / (kcal/hr)-1.5 Ton / 4500 kcal/hr) with all accessories as per OEM suitable for operation on 230V AC ,single phase, 50 Hz as per instruction of Engineer incharge at site. Re- mending work should be done after installation of RAC. (with 1 pair outdoor wall stand) (Industrial AC/Heavyduty AC)
Supply, erection, testing & commissioning of 16 Set mt long High Mast Tower with 8 nos. x 250 watt LED luminaries in symmetrical arrangement complete with all accessories (Double drum winch, SS wire rope, integral power tool motor, head frame, junction box, foundation bolt, LED aviation light, Fedder pillar with single dial timer & raising lowering mechanism etc.) including shallow foundation with M20 grade concrete etc. as per instruction of Engineer Incharge at Site.
Supply, erection, testing & commissioning of 12 Set mt long High Mast Tower with 8 nos. x 150 watt LED luminaries in symmetrical arrangement complete with all accessories (Double drum winch, SS wire rope, integral power tool motor, head frame, junction box, foundation bolt, LED aviation light, Fedder pillar with single dial timer & raising lowering mechanism etc.) including shallow foundation with M20 grade concrete etc. as per instruction of Engineer Incharge at Site.
Supply, installation, testing & commissioning of Numbers 120 watt energy saving, environment friendly & robust Highbay LED with PDC housing suitable for ceiling (Surface/Suspended) mounting with system efficacy upto 150 lm/W as per instruction of Engineer Incharge at Site.
Supply & testing of GI octagonal pole 6 mt long Numbers 120.00 with foundation bolt, loop box of bakelite sheet with one 6A SP MCB and 16 sq mm stud type connector etc. The octagonal pole shall be hot dip galvanized in single dip. Technical specification of pole as following:- Height - 6 mt Top dia (A/F) - 70 mm Bottom dia (A/F) - 130 mm Sheet thickness - 3 mm Base plate (L x B x T) - (200 x 200 x 12) mm Foundation Bolt size (no.x dia) - 4 x 20 dia mm Pitch Circle Dia (PCD) - 200 mm Bolt length - 600 mm Projected Bolt Length - 100 mm .
Supply & fixing of 1 mtr GI Single arm bracket Numbers 120.00 (header) and holder with Nut & bolt as per instruction of Engineer incharge at site.
Erection of Rail/Tubular/Octagonal pole to 1/5 th Numbers 120.00 of its height with CC foundation from base block (30 cm x 30 cm x 15 cm) including digging & refilling of earth to a height of 30 cm above ground level as per drawing no.CEE/OH@47'40@FGA) in ratio 1:3:6 by cement sand & Chips 19 mm & down including excavation of earth.
Supply, installation, testing & commissioning of Numbers 120.00 90 Watt LED street light with pressure die-cast housing and toughened glass and individual LEDs with secondary lens optics for City Road application withIP66 ingress protection. 4kV inbuilt and 10kV external surge protecton with Top opening driver cover for easy maintenance as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Supply, installation, testing & commissioning of Numbers 150 Watt LED Street Light made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK08. as per instruction of Engineer incharge at site.
Supply, installation, testing & commissioning of Numbers 30 W FLAIR PRO is All-in-One Solar Streetlight having compact and fully integrated design with intelligent features includes a built-in Solar Panel, Lithium Ferro Phosphate (LiFePO4) Battery, Charge Controller and Motion Sensor as per instruction of Engineer Incharge at Site.
Supply, installation, testing & commissioning of Numbers 45 W FLAIR PRO is All-in-One Solar Streetlight having compact and fully integrated design with intelligent features includes a built-in Solar Panel, Lithium Ferro Phosphate (LiFePO4) Battery, Charge Controller and Motion Sensor as per instruction of Engineer Incharge at Site.
Supply, Installing, Testing & Commissioning of Numbers High Volume Low Speed (HVLS) FAN, 3 Phase, 1.2 KW , 20 ft. Diameter, 6 (six) Blade with Control Panel and all acessories as per instruction of Engineer Incharge at Site.
Supply, installation, commissioning & testing of Square LED indication station name board (Length of Foot board will be as per proportion of letter so that all the 4 side of the board will have extra space) with channel letters with 3.75 ft. in lenght with suitable widen and 4 mm projection size which inside ACP board (Brand- ALUDECOR, category- AL 33 series exterior & thikness-3 mm) with acrylic face on front and having Sumsung 5630 LED's (Shape- Lens type, operating voltage- 12 V DC, carring current-80 mA, power Dissipation- 0.96 watt, working hours-50000, case material- ABS ,protection-IP68) inside for illumination letters in English, Hindi, Bengali or regional language complete with all materials including provision of erection structure made of MS angle/channel/flat duly painted with aluminium paint over a coat of red oxide primer with CC foundation (1:3:6) of cement, sand and stone chips as required at site and as per instruction of Egnineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Design, manufacture, display of wall /hanging / Square floor mounting type LED illuminated sign / Foot direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 mm thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. (Signage Board should as per Railway Board Letter No. 2023/SD-II/22/07/02 Date. 15.05.2023)
Erection and installation of wall / hanging / floor Square mounting type LED illuminated sign / direction Foot boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text/graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed / router cut on monomeric calendered vinyl of 70 mm thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size end cap of 1.5 mm thick SS 304 should be provided. (Signage Board should as per Railway Board Letter No. 2023/SD- II/22/07/02 Date. 15.05.2023)
Supply, installation, testing & commissioning of Numbers Pure Sine Wave 2400 VA Inverter with Integrated 2560 WH LiFePO4 Lithium-Ion Battery as per instruction of Engineer Incharge at Site.
Supply & erection of Lightning Protection Set System Complete Set with Supply of all accessories, 25 Meters Radius coverage as per instruction of Engineer Incharge at Site.
Supply & erection of Lightning Protection Set System Complete Set with Supply of all accessories, 55 Meters Radius coverage as per instruction of Engineer Incharge at Site.
Supply & erection of Lightning Protection Set System Complete Set with Supply of all accessories, 120 Meters Radius coverage as per instruction of Engineer Incharge at Site.
Supply and commissioning of Monitoring Device Set as per instruction of Engineer Incharge at Site.
Uprooting/Dismantling of HT/LT Rail Pole/Tubular Numbers Pole/Octagonal Pole without damaging the pole by excavation of earth & refilling of the excavated place with soil as per instruction of Engineer incharge at site. KATIHAR DIVISION-ELECTRICAL/N F RLY
Loading, unloading and Carrying of HT/LT Rail Numbers Pole/Tubular Pole/Octagonal Pole from site to SSE's store by contractor own arrangement.
Horizontal machine boring of 300 mm dia hole Metre across track/Road/High drain etc. at a depth of 1.0 mtr below of ground level with suitable boring instruments & neessary arrangement and as per technical procedure.
Supply, laying, commissioning & testing of CI Metre Pipe 200 mm dia Class LA type (IS 1536-2001) to be laid partly along the pole and partly through ground under railway track/road in cable trench for protection of cable with suitable fixing arrangement by MS clamp, nut,bolt,washer etc.as per instruction of Engineer incharge at site.
Supply, fixing, testing & commissioning of IP Numbers 66/67 thermoplastic cable junction box / loop box of size (300 x 450 x 170) mm with knockouts & 04 nos terminals as per instruction of Engineer Incharge at Site.
Supply, fixing, testing & commissioning of IP Numbers 66/67 thermoplastic cable junction box / loop box of size (210 x 310 x 116) mm with knockouts & 04 nos terminals as per instruction of Engineer incharge at site.
Installation & Commissioning of different Numbers 150.00 capacity Flood Light/Street Light as per instruction of Engineer Incharge at Site. (Flood Light/Street Light will be supplied by Railway)
Supply & Erection of earth by 50 mm dia 3 Mtrs. Numbers long (3.6 mm thickness) GI pipe, 32x6 mm GI strip- 5 Mtrs, GI nuts, bolts including masonry materials for earthing pit, salt, charcoal, soldered end terminal etc. and construction of earth pit covered with RCC cover slab12.7 mm thickness and watering pipe as per Drg. No.- PCEE/ELG/DRG/2024/1 Date:- 30.09.2024 and as per instruction of Engineer Incharge at site.
(a) Supply, installation, testing & commissioning Set of oudoor type weather proof sheded feeder pillar box of suitable size made of powder coated 14 SWG MS/CRCA sheet, angle, flat etc. The feeder pillar box four legs should be grounted on CC foundation (1:3:6). Cable entry should have PVC glands. Feeder pillar box should have double door system with locking arrangement with fixing of rubber gasket for protection of entry of dust and water alongwith supply and fixing of following MCCB as per instruction of Engineer Incharge at site.
(b) MCCB FP 63 amps, 25 kA, Ics=100% Icu
(c) Copper bus bar 100 amps made of Set electrolytic grade copper consisting of 4 bars ( 3 Ph and Neutral ) ( Bus bar should have insulation cover)
(d) Supply, installation and testing of Astro Set (Analog) time switch with 3 pole 63 amp contractor and suitable thermoplastic box and fitted on mounting plate/DIN rail. KATIHAR DIVISION-ELECTRICAL/N F RLY
(a) Supply, installation, testing & commissioning Set of 12 way SPN Distribution Board, Flush/Surface mounting, IP 43 grade protection with copper bus bar, fully shrouded neutral bar, earth bar, cable ties, metal double door as per IS 8623 - III with supply and fixing of following RCBO/MCB's as per instruction of Engineer Incharge at Site.
(b) RCBO DP 32 Amp, 2 module Conforms to IEC Numbers 61009-1
(c) MCB DP 16-32 amps, 2 module, 10 kA, Numbers Conforms to IS/IEC 60898 - 1:2002
(d) MCB SP 6-32 amps, 1 module, 10 kA, C-curve Numbers 320.00 Conforms to IS/IEC 60898 - 1:2002
Laying, commissioning & testing of HT/LT Metre XLPE/PVC cable of different sizes partly along the pole and partly through ground in cable trench by excavation of ground below 1.5 mt from ground level with suitable fixing arrangement by MS clamp of size 50x6 mm and suitable size nut, bolt. Loading, Unloading & Carrying of cable to actual work site by contractor's own arrangement. (Aluminium Crimping Socket should be provided for each Cable Termination). (Cable will be supplied by Railway)
Excavation of cable trench (0.3 x 1.5) mtr below Metre ground level for laying of cable & refilling the soil after digging the earth as per instruction of Engineer incharge at site. Cable should be laid on bedding of height 75 mm sand at the bottom of trench, and covering it with additional sand of height 75 mm and thereafter protecing it by mean of bricks before refilling the soil as per IS 1255. Total 32506979.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
IR GCC 2022 Works with all ACS
ATTACHMENT
NITforStationIlluminationMLDTSGUJ_1.pdf Tender Paper
ATTACHMENT
GCCApril-2022PDFwithallACS_compressed.pdf
ATTACHMENT
NITforStationIlluminationMLDTSGUJ_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].