| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-Finance D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹20.1 L+₹2.6 L (14.8%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹22.6 L+₹5.1 L (29.1%)Rejected-Finance | L3 | Rejected-Finance Being not L1 |
Tender Value
₹18.6 L
EMD Value
₹37,160
Closing Date
16 Oct 2024, 6:00 pmClosed
GE (I) DM, Visakhapatnam
GE (I) DM, Visakhapatnam
MAINTENANCE, REPAIR AND PERIODICAL SERVICING OF SPLIT/WINDOW AC, WATER COOLERS AND ALLIED WORKS AND SERVICING, MAINTENANCE AND REPAIRS OF CEILING FANS, WALL MOUNTED FANS, EXHAUST FANS, AND ALLIED WORKS IN DAS, TELEPHONE EXCHANGE UNDER NAVAL DOCKYARD,
2024_MES_675192_1
8055/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender documents
8 documents required · 8 mandatory
₹500
GE (I) DM, Visakhapatnam
₹37,160
Yes
30 Dec 2024
18 Sept 2024
18 Oct 2024
18 Sept 2024
16 Oct 2024
2 Oct 2024
Amount
M&L for servicing/maintenance of split type air conditioner 1.5/2.0 ton cap in situ at any height of building, cleaning of complete outdoor unit and indoor unit, air blower units, air filter, grills with required chemical solution and using forced air blower or vaccuum cleaner, complete checking serviceability of electrical circuit of outdoor and indoor unit, electronic circuit, airblower unit, condenser, remote control unit, including replacement of unserviceable spares such as relays, capacitors, fan blade, PVC mesh filter, wiring kit, screws, nuts, bolts & washers, remote control unit and testing after completion to entire satisfaction of Engr-in-Charge as well as user unit.
Note :- (i) Replacement of spares such as all type capacitors will be measured and paid for separately. (ii) Replacement of capacitors for compressor & fan motors, and replacement of indoor unit fan motor, indoor unit fan blower, condenser fan motor, fan blade, compressor will be measured and paid separately (iii) Contractor has to arrange equipment such as manuplator/ trolly / ladder / tools and all safety precautions to his workmen for carrying out the work and the unit rate quoted shall be deemed to included. (iv) Gas will be measured and paid separately as supply only.
Material and labour for shifting split type AC upto 2.0 tonne capacity from one location to another within DAS area and fixing including making necessary opening for suction and discharge and drain pipe line, brazing copper pipes after grouting of outdoor/indoor unit and making necessary electrical connection, testing and commissioning all as specified and directed.
Taking out uncerviceable refrigerant pipe alongwith insulation from Air Conditioners, supply and fix new refrigerant pipe including brazing & pressure testing complete of following sizes all as specified and directed.
Copper pipe of size 1/4 "
Copper pipe of size 3/8 "
Copper pipe of size 1/2 "
Copper pipe of size 5/8 "
Supply only following spares of Split air conditioner of 1.5 /2.0 Ton cap suitable for Make - Blue Star, LG, Hitachi, Voltas & Samsung, Shriram Usha, Feeder Lloyed & Carrier as per site requirement complete all as specified and directed.
Capacitor 1.5/2.5/4 mfd
Capacitor 6 mfd
Capacitor 45 mfd
Capacitor 50 mfd
Capacitor 50+6 mfd
Conderser fan blade as per existing make.
Remote control unit as per original make complete with 2 Nos. Duracell battery.
Air Filter suitable for indoor unit of split AC 1.5/2.0 Tr capacity of existing make & model.
Condensor
Suction Valve 5/8"
Suction Valve 1/2"
Discharge Valve 3/8"
Discharge Valve 1/4"
Supply and fix outdoor unit of split type AC of cap 1.5/2.0 ton cap in situ as per existing make and compitable model without compressor but including blower motor, fan connecting, necessary copper tubings by brazing / gas welding, gas charging with R-22 after dismentling / taking out existing unserviceable condenser unit and testing after completion to entire satisfaction of Engr-in-Charge and user unit. Note: (i) Gas charging and Compressor unit shall be measured and paid separately under appropriate item of this schedule.
Supply and fix indoor unit of split type AC of cap 1.5/2.0 ton cap complete with cooling unit, PCB, Blower unit with motor, swing motor, remote unit in situ as per existing make and compitable model complete, connecting necessary electrically and copper tubings by gas welding, gas charging with R-22, after dismantling/taking out existing unserviceable indoor unit suitable for AC make-Blue Star, LG, Hitachi, Voltas, Carrier & Samsung whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge and user unit . Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply & fix blower motor, 230V, with required nuts, bolts & washers, connecting necessary wires, fixing of fan complete after dismentling/taking out existing unserviceable/burnt blower motor unit from the indoor unit of split type airconditioner 1.5/2.0 ton cap in situ suitable for Split AC make-Blue Star, LG, Hitachi, Carrier, Voltas & Samsung whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge and user unit.
All as per item No. 07 above, but 1.5 Ton invertor AC unit complete all as specified and directed.
Supply and fix blower for indoor unit of cap 1.5/2.0 ton capacity complete all as specified and directed.
Supply and fix louvers swing motor suitable for indoor unit of split type AC of cap 1.5/2.0 ton cap in situ as per existing make and compitable model, necessary electrical connection after dismantling/taking out existing unserviceable unit suitable for AC make-Blue Star, LG, Hitachi, Carrier, Voltas & Samsung whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge.
All as per item No. 10 above, but for 1.5 Ton invertor AC unit complete all as specified and directed.
Supply & fix new company sealed rotary/reciprocating compressor unit suitable for split type AC with required nuts, bolts & washers, connecting necessary copper tubings by gas welding, gas charging with R-22, replacement of necessary capilary tube and drier filter after dismentling/taking out existing unserviceable/burnt compressor unit from the split type airconditioner 1.5 ton cap in situ and and testing after completion to entire satisfaction of Engr-in-Charge suitable for AC make-Blue Star, LG, Hitachi, Voltas, carrier & Samsung whichever applicable. Note: (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of AC. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule.
All as per item No. 12 above, but for 2.0 Ton AC unit complete all as specified and directed.
All as per item No. 12 above, but for 1.5 Ton invertor AC unit complete all as specified and directed.
Material and labour for Repairs to defective PCB of 1.5/2.0 Tonne capacity split type Air conditioner including replacement of necessary electronic spares like IC, diod, resisters, transformer etc. all as specified and directed.
All as per item No. 15 above, but for 1.5/2.0 Ton capacity indoor unit of invertor type AC complete all as specified and directed.
All as per item No. 15 above, but for 1.5/2.0 Ton capacity outdoor unit of invertor type AC complete all as specified and directed.
Taking down old u/s printed circuit board (PCB) and S & F new PCB of existing make and model in 1.5 / 2 T split AC and connecting up complete all as specified and directed.
All as per item No. 18 above, but for 1.5/2.0 Ton capacity outdoor unit for invertor type AC complete all as specified and directed.
All as per item No. 18 above, but for 1.5/2.0 Ton capacity indoor unit for invertor type AC complete all as specified and directed.
S&F outdoor unit fan motor for 1.5 Ton capacity complete all as specified and directed.
All as item No. 21 above, but 2.0 Ton capacity.
S&F outdoor unit fan motor for 1.5/2.0 Ton invertor type AC complete all as specified and directed.
Taking out power contactor from split type ACs, supply and fix new power contactor single phase, 220 volts all as specified and directed. Make: Siemens / L &T / ABB / HPL.
M&L for refrigerant gas charging for split type AC with R-22/32/410 gas after proper cleaning of pipe lines with carbon tetra chloride and flushing with Nitrogen, complete leakage test, including replacement of liquide line filter, capillary tube, required soldering/brazing/gas welding to attaining proper cooling level to entire satisfaction of Engr-in-Charge and User unit for 1.5 Tr/2.0 Tr Split AC Unit. Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule.
M&L for dismantling unsv voltage stabiliser for repair including replacement of relays, electronic voltage sensor, circuit and meter, micro switch, indicating light, RC filter, and other connected items for making functional and rewinding of transformer unit with suitable size of super enamelled coper wire, heating, vernishing and testing after repair complete for capacity upto 5 KVA and any make complete all as specified and directed.
M&L for 3 core 2.5 Sqmm size copper wire multistranded for connection from indoor unit to outdoor unit complete all as specified and directed. Make : - Finolex/Havells/Polycab
All as per item No. 27 above but 4 core.
M&L for making bore hole of size 80mm dia on wall using bore cutting machine for taking out/in refrigerant piping of split AC including filling of blank space of hole from outside/inside with cement putty complete all as specified and directed.
Supply only R 22 refrigerant gas all as specified and directed. Make : Mafron/Floron
Supply only R 32 refrigerant gas all as specified and directed. Make : Mafron/Floron
M&L for servicing/maintenance of window type air conditioner 1.5/2.0 ton cap in situ by cleaning of complete cooling coil, condenser unit, air blower units, air filter, grills with required chemical solution and using forced air blower or vaccuum cleaner, complete checking serviceability of electrical circuit of unit, airblower unit, condenser, cooling coil, thermostat, copper tubings, including replacement of unserviceable spares such as relays, capacitors, thermostat, wiring kit, screws, nuts, bolts & washers,and testing after completion to entire satisfaction of Engr-in-Charge as well as user unit.
Note: (i) Spares require for replacement for minor repair as mentioned shall be measured and paid as supply only under appropriate item of this schedule and labour charges shall deemed to be included in the quoted rate of this item. (ii) Screws, nuts, bolts & washers shall be inclusive of quoted rate and no extra measurement shall be made. (iii) Items require for major repair shall be measured and paid as M&L under appropriate item of this schedule and rate shall be exclusive of quoted rate of this item. Make of AC - Blue Star, Voltas, Feeder Lloyed, Shriram Usha & Carrier (iv) Contrator will provide Jenny/Manuplator and rate shall deemed to be included in the quoted rate of this item.
Supply only following company recommended spares of Window Air Conditioner of 1.5 /2.0 Ton cap suitable for AC Make-Blue Star, LG, Hitachi, Voltas & Samsung, Shriram Usha, Feeder Lloyed & Carrier whichever applicable complete all as specified and directed.
PVC mesh filters suitable as per existing size.
Conderser/evaporator fan blade as per existing make
Supply & fix new company sealed rotary/reciprocating compressor unit suitable for Window type AC with required nuts, bolts & washers, connecting necessary copper tubings by gas welding, gas charging with R-22, replacement of necessary capilary tube and drier filter after dismentling/taking out existing unserviceable/burnt compressor unit from the Window type Air Conditioner 1.5/2.0 ton cap in situ and and testing after completion to entire satisfaction of Engr-in-Charge suitable for AC make-Blue Star, LG, Hitachi, Voltas, carrier & Samsung whichever applicable complete all as specified and directed. Note: (i) Compressor unit shall be 1st quality with compitable model and make of compressor shall be as recommended by the manufacturer of AC. (ii) Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply & fix new blower motor, 230V, with required nuts, bolts & washers, connecting necessary wires, fixing of fan complete after dismentling/taking out existing unserviceable/burnt blower motor unit from the outdoor unit of Window type airconditioner 1.5/2.0 ton cap in situ suitable for Window AC make-Blue Star, LG, Carrier, Voltas & Samsung whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge and user unit complete all as specified and directed.
M&L for rewinding of blower motor, 230V, 1.5/2.0 TR window AC , after dismentling from the AC unit, transportation to civil wksp outside ND (V) and return after repair, reinstall, testing complete all as specified and directed.
Supply and fix louvers swing motor suitable for Window AC 1.5/2.0 ton cap in situ as per existing make and compitable model, necessary electrical connection after dismentling/taking out existing unserviceable unit suitable for AC make-Blue Star, LG, Carrier, Voltas & Samsung whichever applicable and testing after completion to entire satisfaction of Engr-in-Charge and user unit complete all as specified and directed.
Material and labour for Repairs to defective PCB of 1.5/2.0 Tonne capacity Window Air conditioner, transporting to civil wksp outside ND(V) and return after repair, replacement of necessary electronic spares like IC, diod, resisters, transformer etc all as specified and directed.
S & F new PCB of existing make and model in 1.5 / 2 T Window AC and connecting up complete incl taking down old unserviceable one and all as specified and directed.
M&L for top up of refrigerant gas for split / Window AC with R-22 gas at situ to attaining proper cooling level to entire satisfaction of Engr-in-Charge for 1.5 Tr/2.0 Tr Window AC Unit complete all as specified and directed. Note : - Gas charging shall be measured and paid separately under appropriate item of this schedule.
Supply and fix readymade AC stand for outdoor Split unit of AC/Window AC for wall mounting/floor mounting incl dismantling taking down unsv one one all as specified and directed
M&L for tinkering of base plate including inner body work CRCA sheet bend to shape, drilling holes for mounting accesories as per existing window AC Model, painting with one coat of red oxide and two coats of synthetic enamel paint at both side all as specified and directed
Supply and fixing PVC flexible hose pipe 15 mm dia with suitable saddles, screws incl dismantling taking down unsv PVC pipes as per existing heigh all as specified and directed.
Supply and fixing PVC flexible hose pipe 15 mm dia with suitable saddles, screws incl dismantling taking down unsv PVC pipes as per existing heigh all as specified and directed.
Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl dismantling taking down unsv PVC pipes all as specified and directed.
M&L for tinkering of outer body of window AC made up of 2mm thick CRCA sheet bend to shape of cap 1.5/2.0 ton as per existing make and compitable model and after dismentling / taking out existing unserviceable one all as specified and directed.
M&L for window AC frame made up of 6 mm thick ply sheet cut to shape, drilling holes on wal for mounting as per existing window AC Model, painting with one coat of primer and two coats of synthetic enamel paint as per wall colour at both side incl packing of wall - AC gap with suitable size of thermocole including dismantling taking down unsv one one all as specified and directed
Material & labour for attending complaints of water coolers/ refrigerators/ deep freezers of any capacity by and checking of loose wiring/loose contacts and replacement of unserviceable spares such as capacitor, thermostat,over load protector, relay, fan motor, fan blade and MCBs etc.and charging of gas wherever required , and keeping the water cooler in trouble free condition all as specified and directed. Note:- (i) Spares such as capacitor, thermostat,over load protector, relay, fan motor, fan blade and MCBs etc will be measured and paid under relevant items of schedule 'A' as supply only. (ii) Unit rate quoted shll be deemed to be included for replacement of burnt wires and wiring clips wherever required.(iii)Cost of gas will be measured and paid separately as supply only
Material and labour for refrigerant gas charging of the coolers/deep freezers, thoroughly flushing out the refrigeration system, pressure testing with CO2/N2 gas, arresting of leakage, vacuumisation, supply regrigerant gas & charging the system conducting performance test complete all as specified and directed for following capacities :- Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule.
All as per item No. 51 above, but Deep freezer/ refrigerator of capacity 165 ltrs to 360 ltrs.
Material and labour for servicing the water cooler in position by cleaning the water cooler body, storage tank, fan bushes, blow out the condenser coils with air blower, alignment, greasing and arresting leakages, removing blockages of drain out-let connections, testing trouble free functioning all as specified and directed.
Labour only for disconnecting all connections of the water coolers/refrigerators/deep freezers from the existing location, transporting the same to workshop for carryout body repairs/ gas charging/ painting and transporting back the coolers/refrigerators/deep freezers to it’s original location, installing, connecting up, testing and commissioning all as specified and directed. Note: (i) Body repairs/ painting will be measured and paid under relevant items of schedule 'A'. (ii) Cost of gas will be measured and paid separately as supply only.
Material and labour for cutting & removing all corroded/rusted portion of 40/60/150 ltrs capacity water coolers and making good the same with MS sheet and suitable size of MS angle as existing for the following parts including preparation of smooth surface by using tinkerng paste and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Bottom legs (set of four)
Bottom plate complete
Base plate
Body frame
Top cover including replacement of hinges with rubber gasket
Taking out defective PVC flexible connector, supply & fix heavy duty PVC flexible connector braided type 15mm dia and 450mm long union, nuts & washers on either end all as specified and directed.
Supply only starting/ running capacitors of following capacities :- Make: Sarada/ power
15 Mfd & 10 Mfd
40 Mfd to 60 Mfd
Material and labour for preparing the surfaces smooth by scrapping/chipping the corroded/rusted portions and applying one coat of synthetic enamel paint on inner and outer surface of the entire space of various types of water coolers , deep freezers and refrigerators of following capacity complete all as specified and directed.
40/80 ltrs, 60/120 ltrs
Material and labour for taking out the defective sealed reciprocating / rotary compressors from the following capacities of water coolers and supply & fix new compressors and connecting the refregeration system after flushing out the system, leak testing with CO2, vaccumising and gas charging with refrigerent gas, testing and commissioning all as specified and directed. Note : Cost of gas will be measured and paid separately as supply only Make : As per sample
150 ltrs capacity
40/80 ltrs, 60/120 ltrs capacity
Taking out unserviceable condensers from the following capacity of water coolers and supply & fix new condenser alongwith suitable MS bed all as specified and directed.
Supply & fix stop valve of fancy type chromium plated copper alloy 15mm bore with one GI union and GI nipple on the in-let connection of water cooler all as specified and directed. Make :- Luster/Emerald/Kingston/Bright
Material and labour for taking out defective push/lift cock of water cooler, supply & fix new chromium plated brass self closing tap all as specified and directed. Make : - Anchor/Emerald/Kingston
Material and labour for taking out defective float valve and supply & fix new brass ball valve of 15mm dia complete with polythene float and fly nut screwed for iron pipe of brass ferrule all as specified and directed. Make :- Viking/Hindon/Bright
Supply only FLORON 134a gas high cooling capacity, higher compressor life, ozone friendly, as AHRI 700 purity standards. Container Net Weight 450 grams all as specified and directed. Make : SRF Ltd or equivalent.
Supply only fan motor of 1/35 HP capacity all as specified and directed. Make :- Frac Master/AUE/Signature
Supply only fan motor 10 watt capacity all as specified and directed. Make :- Frac Master/AUE/Signature
Supply only fan motor of 1/83 HP capacity all as specified and directed. Make :- Frac Master/AUE/Signature
Supply only relay as existing make and model all as specified and directed. Make :- Hitech/Usha/Aravind
Supply only Thermostat switch all as specified and directed. Make: Indfos/ Voltas
Supply only fan blade of same as existing size and model all as specified and directed.
Supply only overload protector suitable for as existing size and model all as specified and directed.
Material and labour for taking out the corroded in-let and out-let pipe lines of water cooler and supply & fix new GI pipe line of medium grade, 15 mm bore conforming to IS-1239 part I complete with all fittings and specials such as elbows, bends, tees, unions etc, all as specified and directed. Make :- Oswal/Kalinga/Zindal /Tata
Taking out the perished PVC flexible drain pipes from water cooler and supply & fix new PVC flexible drain pipe of size 25mm dia all as specified and directed
Supply and fixing SS water storage tank 80 ltr cap with cooling coil as existing size and taking out old unserviceable one all as specified and directed.
Supply and fixing of drain tray made stain less steel as existing sizes and taking out old unserviceable one all as specified and directed.
M&L for painting in letters details of Water cooler as Capacity, Tank cleaned on, last servicing carried out on date etc. complete all as specified and directed.
M&L for dismantling & taking out ceiling fan of any sweep from its position ceiling mounting hook, transportation from building to complaint cell and further transportaion to civil workshop outside DAS for rewinding of Ceiling fan 1200/1400 mm sweep after opening complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, varnishing, replacement of unsv bearings / bushings / capacitor pad / connector block, connection wire 3 core, assemble of rotor and stator unit with capacitor, connecting wire, capacitor pad, down rod, blades and bring back after repair and install at original position including connection complete all as specified and as directed.
All as per item No. 77.00 above, but for wall fan/ table fan/ pedestal fan/ exhaust fan/ air circulator fan of 300/380/400mm sweep
All as per item No. 77.00 above, but for wall fan/ table fan/ pedestal fan/ exhaust fan/ air circulator fan of 450mm sweep .
All as per item No. 77.00 above, but for pedestal fan/ exhaust fan/ air circulator fan of 600mm sweep complete all as specified and as directed.
M&L for servicing of ceiling fan 1200/1400 mm sweep in situ after dismanting taking down from ceiling mounting hook, complete cleaning of fan, greasing/oiling of bearing / bushings, replacement of unsv capacitors, damaged bearings / bushings, connection wire, tightening of nuts, bolts, washers, and refixing to original position with required new rubber bushings / mounting bolts complete all as specified and directed.
M&L for servicing of exhaust fan heavy duty 300/380/450 mm sweep in situ after dismanting taking down from its mounting position on wall at height 3 mtr to 9 mtr from floor, complete cleaning of fan, greasing/oiling of bearing and bushings, replacement of unsv capacitor, damaged bearings, connection wires, tightening of nuts, bolts, washers, Checking for serviceability of all mounting brackets, foundation bolts and refixing to original position with required new rubber bushings / mounting bolts complete all as specified and directed.
M&L for servicing of air circulator/pedestal fan heavy duty 300/400/450/600 mm sweep in situ after dismanting taking down from its mounting position on wall / steel or RCC column at height upto 3 mtr for FL, complete cleaning of fan, greasing/oiling of bearing and bushings, replacement of unsv capacitor, damaged bearings, connection wires, regulator, oscilating mecanism, tightening of nuts, bolts, washers, Checking for serviceability of all mounting brackets, foundation bolts, protection grills and refixing to original position with required new rubber bushings / mounting bolts complete all as specified and directed.
S&F down rod of ceiling fans 61cm to 91 cm long including nuts, bolts, washers after dismantling taking down old one complete all as specified and directed.
S&F front & rear grill of air circulator and pedestal fans for 300/380/450mm sweep incl dismantling taking out old one complete all as specified and directed.
S&F front & rear grill of air circulator and pedestal fans for 600 mm sweep incl dismantling taking out old one all as specified and directed.
M&L for painting of ceiling fan 1200 / 1400 MM sweep incl blade, canopy, down rod with one coat of synthetic enamel paint white colour complete all as specified and directed.
M&L for painting of heavy duty exhaust fan 300 / 400 / 450 / 600 mm sweep incl blade and frame with one coat of synthetic enamel paint smoke grey colour complete all as specified and directed.
M&L for painting of heavy duty air circulator fan 300 / 400 / 450 / 600 mm sweep incl blade and frame with one coat of synthetic enamel paint smoke grey colour complete all as specified and directed.
Supply & fixing ball bearing 6200 / 6201 / 6202 / 6203 suitable for ceiling fan & exhaust/wall/aircirculator fan 300/400 /450 mm sweep complete all as specified and directed.
Supply & fixing capacitor 2.5 mfd for ceiling fan and air circulator upto 450mm sweep complete all as specified and directed.
Supply & fixing capacitor 4 mfd for 600 mm aircirculator fan and 450mm exhaust fan complete all as specified and directed..
Supply & fixing capacitor 10 mfd for 600 mm exhaust fan/blower complete all as specified and directed.
Supply & fixing set of fan blade(3 Qty) for ceiling fan of size 1200/1400mm size with bolts,clamps and necessary accessories as per the existing make including taking down & refixing to original position complete all as specified and directed.
S&F mild steel alloy D-hook with 2 Nos M10x75mm expansion fasteners hanger (heavy duty) fixed to ceiling for proper hanging of ceiling fan and making good disturbed surfaces to match with the existing one including taking down & refixing to original position complete all as specified and directed.
Supply & fixing set of fan blade(3 Qty) for exhaust fan of size 300/380mm size with bolts,clamps and necessary accessories as per the existing make including taking down & refixing to original position complete all as specified and directed.
Supply & fixing set of fan blade(3 Qty) for exhaust fan of size 450mm size with bolts,clamps and necessary accessories as per the existing make including taking down & refixing to original position complete all as specified and directed.
Supply & fixing set of fan blade(3 Qty) for exhaust fan of size 600mm size with bolts,clamps and necessary accessories as per the existing make including taking down & refixing to original position complete all as specified and directed.
Supply & fixing set of fan blade(3 Qty) for air circulator fan/pedestal fan of size 450mm size with bolts,clamps and necessary accessories as per the existing make complete all as specified and directed.
Supply & fixing set of fan blade(3 Qty) for air circulator fan/pedestal fan of size 600mm size with bolts,clamps and necessary accessories as per the existing make including taking down & refixing to original position complete all as specified and directed.
Supply & fixing fan stand for pedestal fan of size 450mm size with bolts,clamps and necessary accessories as per the existing make including taking down & refixing to original position complete all as specified and directed.
Supply & fixing fan stand for pedestal fan of size 600mm size with bolts,clamps and necessary accessories as per the existing make includingh taking down & refixing to original position complete all as specified and directed.
Supply & fixing LED flame proof fitting for twin a T8 tube of 18/20 W including dismantling taking down unserviceable one any type complete all as specified and as directed
Supply & fixing LED flame proof highbay light fitting 120 W watt with heat resistant toughned glass at roof truss level of wksp buildings and other places including dismantling taking down unserviceable one any type complete all as specified and as directed
M&L Rewinding of 3HP motor of 3 phase exhaust blower in situ after dismantling taking down from its mounting position on roof at height upto 15m from FL, after opening complete motor assy, bearing bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire heating, varnishing, bushings connector block, connection wire 3 core assemble of rotor and starter unit with capacitor, connecting wire, capacitor pad, down rod, blades complete all as specified and directed. Note: Transportation from buildings/workshop to complaint cell and further to civil workshop outside DAS for rewinding and bring back after repair is inclusive of rate complte all as specified and as directed.
SATYAM ENGINEERS (BID ID -3140672)
SRI SIDDHI VINAYAKA ENTERPRISES (BID ID -3133851)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .