Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.5 LAccepted-AOC | ₹46.5 L Quoted ₹39.4 L | L1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | UBAISE M.B L1 |
|---|---|---|---|---|
| 1.00Appendix A - School Building | ||||
| 1.00 | 11.37 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete | 27 | sqm | 1,052.44 ₹28,415.88 |
| 1.00 | 50.9.3.1 Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood | 7.56 | sqm | 2,991.04 ₹22,612.26 |
| 1.00 | 50.9.4.1 Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood | 7.56 | sqm | 2,680.09 ₹20,261.48 |
| 1.00 | 22.7.1
Providing and laying integral cement based water proofing treatment including
preparation of surface as required for treatment of roofs, balconies, terraces etc.
consisting of following operations: a) Applying a slurry coat of neat cement using
2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS:
2645 and approved by Engineer-in-Charge over the RCC slab including adjoining
walls upto 300 mm height including cleaning the surface before treatment. b) Laying
brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with
50% of cement mortar 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing
compound conforming to IS: 2645 and approved by Engineer-in-Charge over 20 mm
thick layer of cement mortar of mix 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer - in
Charge to required slope and treating similarly the adjoining walls upto 300 mm
height including rounding of junctions of walls and slabs c) After two days of proper
curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed
with water proofing compound conforming to IS : 2645 and approved by Engineer-in
Charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4
( 1 cement : 4 coarse sand ) admixed with water proofing compound conforming to
IS: 2645 and approved by Engineer - in- Charge including laying glass fibre cloth of
approved quality in top layer of plaster and finally finishing the surface with trowel
with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e)
The whole terrace so finished shall be flooded with water for a minimum period of
two weeks for curing and for final be flooded with water for a minimum period of
two weeks for curing and for final test. All above operations to be done in order and
as directed and specified by Engineer in Charge:With average thickness of 120 mm
and minimum thickness at khurra as 65 mm | 115.6 | sqm | 1,713.08 ₹2.0 L |
| 1.00 | OD12918/2024-2025
Engaging fitter | 5 | each | 1,179.9 ₹5,899.50 |
| 1.01 | OD12919/2024-2025
Engaging Carpenter | 5 | each | 1,179.9 ₹5,899.50 |
| 1.01 | OD12920/2024-2025
Engaging cooli | 5 | each | 970.71 ₹4,853.55 |
| 2.00Appendix B - Hostel Building | ||||
| 2.00 | 2.8.1
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means
in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan),
including dressing of sides and ramming of bottoms, lift up to 1.5 m, including
getting out the excavated soil and disposal of surplus excavated soil as directed,
within a lead of 50 m.All kinds of soil | 15.62 | cum | 322.67 ₹5,041.72 |
Tender Value
₹41.4 L
EMD Value
₹50,000
Closing Date
23 Aug 2025, 5:00 pmClosed
CHIEF ENGINEER, KSCADC
KSCADC Building, Kamalewsaram , Manacaud P.O. Thiruvananthapuram Pin-695009
GRFTHS for Girls, Kanhangad in Kasargod District- Maintenance Works- Civil And Electrical works(Re-Tender)
2025_SCADC_780700_2
ET-41/2025-26
Open Tender
Civil Works - Buildings
180 days
Kanhangad in Kasargod -District
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,950
₹50,000
25 Mar 2026
16 Aug 2025
25 Aug 2025
16 Aug 2025
23 Aug 2025
16 Aug 2025
Amount
Appendix A - School Building
11.37 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete
50.9.3.1 Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood
50.9.4.1 Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood
22.7.1 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-Charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-Charge over 20 mm thick layer of cement mortar of mix 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer - in Charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in Charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement : 4 coarse sand ) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer - in- Charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in Charge:With average thickness of 120 mm and minimum thickness at khurra as 65 mm
OD12918/2024-2025 Engaging fitter
OD12919/2024-2025 Engaging Carpenter
OD12920/2024-2025 Engaging cooli
Appendix B - Hostel Building
2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
50.6.7.1 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
OD114559/2025-2026 Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
5.1.3 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9.1 Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.9.1.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
50.9.3.1 Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Anjili/ Jack wood
50.9.6.1 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood / jack wood 30 mm thick shutters
9.123 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogeneous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer's specification and direction of Engineer-in-charge.
9.124.2 Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mm x 1 mm, painted with primer, all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (Push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5 mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rails of sixe 100mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100 mm x 8 mm complete as per manufacturer's specifications and direction of Engineer -in-charge.Decorative finish (both side wood grained finish)
OD13621/2024-2025 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position etc complete based on 10.2
OD13622/2024-2025 Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position including welding and bolted with special shaped washers etc. complete based on 50.10.2
12.1.3 Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m2
13.112.1 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shadeOld work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface
OD18972/2025-2026 Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) based on 13.46.1
12.7.1 Providing and fixing 15cm wide, 45 cm overall semi circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.0.80 mm thick with zinc coating not less than 275 gm/m2
13.48.2 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture
13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
51.19.ST4 Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately) 4. 35 to 50 flush capacity
19.33 Constructing soak pit 1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
16.68 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
16.83 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
16.84 Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)
17.7.2 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap
17.2.1 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
17.70.2 Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the center of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms
50.17.1.1 Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
50.17.1.2 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in charge.
50.17.1.4 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.
18.15.2 Providing and fixing brass bib cock of approved quality :20 mm nominal bore
50.18.7.3.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer- in- Charge 25 mm dia 12 Kgf/cm2 - Internal work - Exposed on wall
50.18.8.4.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2
50.18.8.6.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
50.18.8.8.2 Providing and fixing PVC pipes, fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per the direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 4 kgf/cm2
50.18.8.9.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2
50.18.9.3.1 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge 25 mm dia 12Kfg/cm2
50.18.9.4.2 Providing and fixing PVC pipes includings joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia 6 Kgf/cm2
50.18.9.6.2 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 6 Kgf/cm2
50.18.9.8.2 Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching and refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 4 Kgf/cm2
50.18.9.9.2 Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2
50.18.9.13.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 12 Kgf/ cm2- External work- exposed on wall
50.18.9.16.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall
50.18.9.19.1 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
50.18.9.21 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Elbow
50.18.9.21.2 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow
50.18.9.21.3 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia Door Elbow
50.18.9.21.4 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend
50.18.9.21.5 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75x75x75 mm dia Tee
50.18.9.21.7 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl
50.18.9.22.1 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
50.18.9.22.2 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow
50.18.9.22.3 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow
50.18.9.22.7 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x75 mm dia Door Tee
50.18.9.22.8 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
50.18.9.22.12 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer
50.12.2.4 Providing & fixing Poly carbonate multi wall plain sheet 6 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12m or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/self tapping screw of size (5.5x55mm) with EPDM seal complete upto any pitch in horizontal/vertical curved surfaces, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required.
OD12924/2024-2025 Engaging Carpenter
OD12925/2024-2025 Engaging Plumber
OD12926/2024-2025 Engaging cooli
Electrification- Wiring
1.10.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.30 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
OD20497/2025-2026 Supply, installation and laying of 3 cores, 16/0.20mm round copper flexible cable through down rod/hanging chain.... for connecting the hanging electrical item with the ceiling rose
OD20498/2025-2026 Supply and fixing of ferrules on wire for circuit identification, as required (Any make approved by CPWD/KPWD/KSCADC) 6sqmm wire
OD20499/2025-2026 Supply and fixing of ferrules on wire for circuit identification, as required (Any make approved by CPWD/KPWD/KSCADC) 1.5 to 2.5sqmm wire
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
OD20495/2025-2026 Labour charges for removing/dismantling the existing conduit, wire, cable, LAN cable, Electrical inventories etc… and placing them on an appropriate place for further actions.
OD20496/2025-2026 Supply and fixing of Cable Zip Ties, White (100 mm x 2.5 mm,4" inch) Multi Purpose Self-Locking Nylon Teeth Grip Cable Ties Cord Management Ties, Plastic Ties for cables, industries, Workshop.
Switches and Sockets
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.57 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. lCD
90.10.3.32 Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.28.4 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.28.6 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module
Conduits
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
OD20655/2025-2026 Supply and fixing of Conduit Adaptor Male PVC Lock Nut 20/25mm Hole Dia Seal Connect for Conduit Box that connects the pipes and the electrical boxes. With glue to one end of the conduit, connect the conduit and the adapter and tighten the lock nut to the mounting hole of the bottom box. Made of PVC material, the adapter is waterproof, corrosion resistant, and flame retardant.
2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
90.11.1.11 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
OD20553/2025-2026 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB/enclosure complete with connections, testing and commissioning etc. as required (Approved make by CPWD/KPWD/KSCADC). 25A
2.13.1 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2.23.4 Supplying and fixing Cable End Boxes (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with testing and commissioning etc. as required. For 14 way, Double door SPN MCBDB
2.24.2 Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 6 way, Double door TPN MCBDB
Fittings
90.4.5.4 Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.59 Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required.
1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD20559/2025-2026 Supply and fixing of ceiling fan capacitor - 2.5mfd
OD20578/2025-2026 Supply, fixing and installation of PVC Waterproof Bulkhead outdoor type with B22 Holder (Regular Pin Type) for Which LED Bulb Easily Available in Market. (Bulb not Included) Color: White (Approved make by CPWD/KPWD/KSCADC)
OD20560/2025-2026 Supply and fixing of B22 LED Cool Day White LED Bulb - 9W. (Approved make by CPWD/KPWD/KSCADC)
90.4.8 Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
90.4.10 Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
OD20579/2025-2026 Supply of Light Duty Exhaust fan in plastic body with self-opening lovers working on 230v single phase A/C - 250mm
OD20574/2025-2026 Supply and fixing of Anchor Steel Double D-Hook Hanger (Heavy Duty) with Fasteners for Hanging Chandelier, Ceiling Fan or Jhoomer, Golden (Double D Hook). consists of 1 Pc. of D-Hook & 2 Pcs. of heavy-duty Fasteners (M10x75mm). Specially designed to hang Ceiling Fans, Jhoomer, Baby Swings, Ropes, etc. Pull out load is 75 Kgs and Jurk/Vibration load is 40 Kgs. Need to use 10 mm diameter drill bit for drilling holes on ceiling or wall to fix Fastener. The drilling depth should be greater than or equal to 65 mm. Fastener outer diameter approx. 10 mm. Approved make by CPWD/KPWD/KSCADC)
OD20575/2025-2026 Supply and fixing of water purifier having Hot & Ambient 9-Stage RO, Dual Stainless Steel Tank Water Purifier | RO+UV+Active Copper Tech | Taste Adjuster | Upto 60% Water Savings | Suitable for all Water Sources. Wall mount type, Countertop. Change Filter Indicator, Reduce TDS. Capacity 5.6 liters. Maximum Flow Rate -15 Liters Per Hour. Operating Pressure Range‎3 Kilograms Per Square Centimeter. Upper Temperature Rating‎40 Degrees Celsius. (Make: ‎Aquaguard Model Name: GWPDIRUHA03000 or equivalent make approved by CPWD/KPWD/KSCADC)
OD20576/2025-2026 Supply of Electric Bug Zapper, Fly Catcher Machine for Indoor, Home, Office Restaurants, industries and showrooms with UV light technology to attract and trap insects effectively, Low noise operation for an undisturbed ambiance. Product Dimensions - ‎60 x 20 x 40 cm; 1 kg. Approved make by CPWD/KPWD/KSCADC
OD20577/2025-2026 Supply, fixing and commissioning of 4", 1X20W LED tube light in plastic frame body with stainless steel clips and stainless screws, as required. (Approved by KSCADC/PWD)
90.15.4.2 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD20725/2025-2026 Supply and fixing of 9W B22D LED Emergency Inverter Bulb (Cool Day Light/Crystal White). Rechargeable, Energy Efficient, Flicker-Free, Eye-Friendly. (Make: Philips or equivalent make approved by CPWD/KPWD/KSCADC)
EM Box
OD20589/2025-2026 Supply and installation of weatherproof single/three phase Energy meter box with provision for HRC fuses - 3Nos/1No.., Neutral Link - 1No. and a 4P/DP isolator, made in fiber. Double Door. Including all accessories for installation. Approved Make by CPWD/KPWD/KSCADC
2.13.3 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
OD20610/2025-2026 Supply and fixing of 100 A, 2 Way neutral links mounted on DMC/SMC base
OD20611/2025-2026 Supply and fixing of 100A HRC Fuse Base with HRC Fuse link
Fire and Safety
OD20719/2025-2026 Supply and providing First Aid Box with first aid medicines and accessories. Color: Red & White, Size:11Inch * 13 Inch * 3 Inch (W x D x H). Made from galvanize Metal with 7 Way Processed Powder Coating for Long Lasting. Front Heavy Clear acrylic. 4 Partition for medicines organize with lock and 2 set of key. Top side handle for carry to any where and also Wall Mountable.
OD20720/2025-2026 Supply of Fire Bucket Stand with 2 Bucket and sand. Material : Iron. Ring Handle Mounted
OD20721/2025-2026 Supply and laying of Checkered Electrical Rubber Mats, Thickness 6mm (Black, 1 M X 2 M) - 1 Pc/Insulating Rubber Mat, Anti – Skid, Shock Proof with excellent mechanical properties to overcome movement of breaker trolleys and associated electrical equipment such as heavy foot traffic. Ideal to use for: Sub – station, Power Transformer Rooms, LT & HT Labs, near bus bars and at ear control panels.
OD20722/2025-2026 Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision.
OD20723/2025-2026 Supply, fixing and installation of ABC Powder Type 6 Kg Fire Extinguisher (Red and Black) effective for all types of fire like Class A, B and C types of fires as well as Electrical fires and also ABC Powder Type (Stored Pressure) Fire Extinguisher, Multipurpose uses with 1 Wall Hook and 1 Discharge Pipe. ISI, ISO and CE Certified Product and Multipurpose Uses ABC Type fire extinguisher 6 Kg with 5 years Warranty. (Approved make by CPWD/KPWD/KSCADC)
Bidder Name
UBAISE M.B
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1294540.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_1294540.xls
BOQ • 0.40 MB
TD410725.pdf
Tender Documents • 3.59 MB
SPC.pdf
Additional Documents • 0.02 MB
Plan.pdf
Other Document • 2.58 MB
Download all tender documents and submit your bid