Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-AOC WZ 199 LAJWANTI GARDEN GALI NO 4 NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹39.8 L+₹69,213.20 (1.77%)Rejected-AOC 11 CIVIL LINES ROORKEE 247667 DISTT HARDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | L2 | Rejected-AOC Rejected being not L1 | |
| 3 | L3₹42.3 L+₹3.2 L (8.17%)Rejected-AOC D 502 SHIVILOK COLONY RAIPUR ROAD DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | L3 | Rejected-AOC Rejected being not L1 | |
| 4 | Rejected-Technical VILL BHANGERI PO ROORKEE PIN 247667 | HARIDWAR | UTTARAKHAND | 247667 | - | Rejected-Technical No remarks given in WLR of CECC QE Sep 2021 |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
4 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (MES) ROORKEE
Garrison Engineer Military Engineer Services Roorkee
SPL REP TO BLDG No. P288 AND P289 DSV PLANT AND CLASS ROOM AT CIW AT BEG AND CENTRE IN THE AREA OF AGE BR II UNDER GE ROORKEE
2022_MES_507334_2
8392/094/E8
Open Tender
Civil Works
Item Rate
180 days
Roorkee
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (MES) Roorkee
₹78,000
Yes
1 Jun 2022
14 Mar 2022
6 Apr 2022
14 Mar 2022
4 Apr 2022
22 Mar 2022
60 days
Amount
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified and directed.
S&F Aluminium anodised snap grid frame work for false ceiling of, grid 605 mm X 605 mm with Aluminium "T" section of size 38 x 25x 1.50 mm thick for main runners, 25 x25 x1.50 mm thick cross runners and angle of size 25 x 25 x 1.50 mm thick along the walls suspended with and including 4mm dia adjusting levels fixed to roof slab by means of ceiling cleats made out of GI flat iron 40 x 3 mm size 60 mm long and expension hold fasteners 12.5 mm dia , 40mm long galvanised mild steel wire (as in suspenders of ceiling members fixed in proper position) including providing and fixing Gypsum Board 12mm thick in ceiling fixed with screws as per manufacturer's instructions and applying two coat of plastic emulsion paint complete all as specified and directed. Make of Gypsum board: Saint Gobain/ Gypsum India
Taking down roof trusses of clear span above 4 mtr & upto 8 mtr, coupled rafters or trussed beams including taking down trusses etc., for re- newal of any defective members (timber renewed to be measured separately) and reassembling complete all as specified and directed.
Materials and Labour for brick work with Sub Class ‘B’ bricks straight or curved on plan exceeding 6M mean radius built in cement mortar (1:6), including demolition complete all as specified and directed.
Materials and Labour for plain cement concrete (1:2:4) type B1 using 20 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates,kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary from work complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
S&F in repairs second-class hard wood timber scantlings, clean sawn, in framed works and in any position exceeding 40 Sqcm and over in section fixed with nails complete all as specified and directed.
M&L for Steel tubular Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to I. S.1161- 1979 grade Fe-290 (GdeSt.-240 complete all as specified and directed.
S&F in repairs second class hard wood plain fillets, of cross sectional area exc. 13.00 Sq cm and n. exc. 25.00 Sq cm, square, rectangular or triangular in section, wrought, fixed with nails , complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semi corrugated etc) sheets in roof covering complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any approved colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for pre-painted, galvalume aluminium zinc coating GI based plain steel sheet, 0.50 mm thick of any colour, having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
M&L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified and directed.
M&L for rendering 15 mm thick cement plaster in cement mortar (1:6) on other than fair faces faces of brickwork or concrete surfaces in walls and finishing surface even and smooth without using extra cement, including taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etccomplete all as specified and directed.
M&L for rendering 15 mm thick cement plaster in cement mortar (1:4) on fair faces of brickwork or concrete surfaces in walls and finishing surface even and smooth without using extra cement, including taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for applying two coat of oil bound distemper over a coat of Chalk whiting primer to new plastered surface on wall including preparation of surfaces complete all as specified and directed.
M&L for preparing new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali-resistant primer complete all as specified and as directed.
M&L for complete removal of existing treatment on wall surface and applying two coats of cement base paint over a coat of alkali-resistant primer complete all as specified and as directed.
M&L for Non - skid Ceramic joint free colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15 mm thick screed bed in CM 1:6 including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and directed.
M&L for glazed ceramic colour joint free tiles in vertical surface 450X 300X 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering in CM 1:4 including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), and rubbish off the premises complete all as specified and directed.
M&L Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and Brushing neat cement slurry with 3.00 kg of cement per sq metre complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over 20 mm screed bed in cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over backing coat 10mm thick in cement mortar 1:4 and jointed with neat cement slurry including rubbing and polishing complete all as specified and directed.
Taking down chowkhat with shutter .exe 1.50 sqm and nexe 4 sqm (without taking off shutter) each complete all as specified and directed.
Taking down chowkhat with shutter n.exe 1.50 sqm (without taking off shutters) each complete all as specified and directed.
M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. confirming to Fe- 290 grade E-165 to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S&F factory made flush shutters, solid core 30 mm thick construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 300mm size of bolt aluminium anodised sliding door bolts (ISI marked) with hasp, stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F 150mm size aluminium anodised barrel tower bolts (ISI marked) of extruded section and fixed to shutter complete all as specified and directed.
S&F 125mm size extruded aluminium alloy handles (ISI marked) fabricated type anodised complete all as specified and directed.
S&F 125mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised (ISI marked) and fixed, type B-21 complete all as specified and directed.
S&F factory made steel windows with side hung shutters including projection type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
M&L framed work such as grills etc with ends of bars shouldered and or riveted or forged into spike; framed guard bars and similar work conforming to Fe 410-0 0r Fe 310-0 complete all as specified and directed.
S&F mild steel flat iron as in hold fast clamps small articles conforming to FE 290 GDE -E- 165 complete all as specified and directed.
S&F 4.0 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all specified and directed.
Cutting holes in brick walls exc. half brick but not exc. one brick in cement mortar for inserting holdfasts and making good dismantled portion in cement concrete 1:2:4 Type B-1 or cement mortar 1:3 complete all as specified and directed.
M&L for applying two coat of synthetic enamel paint over a coat of red oxide on steel surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
M&L for applying two coat of synthetic enamel paint over a coat of pink primer on new wood or wood based surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint on old wood or wood based surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
M&L for 25 thick PCC type B-0, 1:2:4 (12.5mm graded aggregate) complete all as specified and directed.
S&F Harrison rails, anodised aluminium alloy, chromium plated with fixing brackets,stops,rollers etc. complete all as specified and directed.
Taking down existing point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator etc and M&L for new concealed point wiring with 1.5 Sqmm (Nominal area) PVC insulated and PVC unsheathed FRLS multi stranded copper conductor single core FRLS cable drawn through and including PVC non metallic conduit of 20 mm dia (ISI marked) with all accessories including GI sunken box made of 1.6mm thick GI sheet with 3 mm thick bakelite sheet top cover (ISI marked) and PVC insulated and unsheathed single core multi-stranded copper conductor FRLS green colour cable of size 1.5 Sqmm (Nominal area) as earth continuity conductor connected to common earth and earth dolly including cutting chases for concealed point wiring and making good in cement mortar (1:3) including white washing/distempering of any type to match the existing surfaces complete all as specified and directed for the following :-
One light point controlled by one, one way switch complete all as specified and directed.
One Ceiling/exhaust fan point controlled by one, one way switch complete all as specified and directed.
One 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and directed.
One 3/5 pin 5 Amps socket outlet on independent board complete all as specified and directed.
All as per item No 43.00 above but concealed wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed FRLS cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed FRLS cable, green colour as earth continuity wire, for the 15 Amp 3/5 pin socket power point complete all as specified and directed.
S&F switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified and directed.
S&F switch piano flush type polycarbonate single pole one way 15 Amps complete all as specified and directed.
S&F socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush type complete all as specified and directed.
S&F socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type complete all as specified and directed.
S&F electronic fan regulator 230 volts , step type (5 step) socket type, hum free 100/300 watt complete all as specified and directed.
M&L for Ceiling rose in poly carbonate 3 terminal brass flush type 6 Amps,250 volts AC ISI marked, fixing on 3 mm thick sunmica hylum plastic laminated round sheet 75mm dia complete all as specified and directed. Make: Havells (ROHS) cat part No . AHLHXCW000 / Anchor PC cat part No- 3907250916 / SSK cat part No B07QS98JCQ
S&F LED bulb 12 watts with B-22 base operated on single phase AC supply complete all as specified and directed. Make : Wipro/Havells/Bajaj/C&S
S&F batten holders (metal ring) PVC / polycarbonate type with back plate, fixing on 3 mm thick sunmica hylum plastic laminated round sheet 75mm dia complete suitable for LED bulb complete all as specified and directed. Make: Havells (ROHS) cat part No AHLHXAW000 / Anchor PC cat part No- 3980051170 / SSK cat part No 76
S&F In replacement of old unserviceable light fittings LED tube light fitting 20 Watt industrial batten box type with bipin holders connector block complete with all accessories internally prewired and incl connecting up three core single wire incl 01 no. 20 watt retrofit LED tube rod T8 polycarbonate to be fixed at any height of wall/ceiling complete all as specified and directed. Make : Havells (Rod) Cat No-PHOTONULTRAE 2.01213T8SSTL20WLED865SPC Havells (Batten) Cat No- REGALBATTENT 8UPTO1X22WSSBSWH/ Bajaj (Batten) Cat No- 112181 BLRB-DB 118, Bajaj (Rod) Cat No - 112481 BLRB 21W CWC / C&S LTDC0161820WLED + LT4F20WLEDT8WD.
S&F in replacement of old unserviceable Building security light fitting versatile pressure die-cast aluminium with high power LED 25 W as light source complete with LED 25 W 5000K including brackets made out of GI pipe light grade pipe bent to shape incl 02 Nos MS flate clamps incl nut bolts connection complete all as specified and directed. Make : C&S cat part No. LTESSI25WLED/ BAJAJ CAT No - 169821 BCLST 25W LED/ Wipro Cat No - D923065.
S&F In replacement of old unserviceable light fittings LED tube light fitting 2x20 Watt (4 feet) industrial batten box type with bipin holders connector block complete with all accessories internally prewired and incl making fixing arrangement, suspended to ceiling with metal chain-02 Nos, 2 feet length, connecting up three core single wire incl 2x20 watt retrofit LED tube rod T8 polycarbonate to be fixed at any height of wall/ceiling complete all as specified and directed . Make: Crompton Cat part No/Product code No-IGP162LT8-16/ Havells Cat No- REGALBATTENT8UPTO2X22WDSBSWH/ Bajaj Cat No - 112236 BPTXn 2-20W LED 8F WH .
S&F in replacement of recesss mounting light fitting 2' x 2' of capacity 36 Watts powder coated white CRCA full glow suitable for false ceiling including making electrical connection from ceiling rose to light fitting complete all as specified and directed Make: C&S Cat . LTCRP36WLED2X2/ Havells Cat No- STRATO2X2PLR36WLED857MOD/ BAJAJ CAT No - 111778 BZRSQL 36W GZ WH .
S&F in replacement of old unserviceable LED Flood light fitting 30 watt capacity with SMD LED pressure die-cast aluminium housing with reflector including making electrical connection from ceiling rose to light fitting complete all as specified and directed. Make: Bajaj Cat No - 112716 BJFL 30W LED/ Wipro Cat No- D913065/ C&S Cat No - LTEFI30WHPLED
S&F Sub main wiring with two runs of single core FRLS PVC insulated and unsheathed multistranded, copper conductor cable of size 6.0 sqmm LT, 1100V grade, drawn through and incl adequate sizes PVC non metallic conduit of 20mm/approprite dia with accessories and fittings and one run of 6.0 sq mm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm/approprite dia shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe including taking down old sub main wiring complete all as specified and directed. Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate and shall not be measured seprately. Make of Cable- HPL/Havells /policab/Grandley Make of PVC conduit - Kinjal/atul/plaza Plast/Kalinga
S&F In replacement of old unserviceable Distribution board (DB) VTPN 4 way made out of sheet metal enclosure (CRCA sheet) dust and vermin proof IP 43 (double door) with 250 Amps rated copper bus bar neutral bar ,earth bar ,triple pole and neutral , with provision for 100A MCCB as incomer and MCBs TP/DP/SP as outgoer ,flush to wall complete all as specified and directed. MAKE- LEGRAND : Cat No 5077 45 or C&S Cat No - CSDBMCCB100DD04IP43S or INDOASIAN Cat No - 811888
S&F in replacement of unserviceable MCCB 100 Amp four pole, 415 volt, 25kA adjustable thermal and magnetic setting including necessary connection complete all as specified and directed. Make: Legrand cat part No.420055/ C&S Cat No - CSE1M125ATM4P-100/ Indo Asian Cat No- 830272 .
S&F in replacement of old unserviceable Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 12 way IP 43 (double door) with 100 Amps rated copper bus bar neutral bar ,earth bar ,single pole and neutral 250 volts ,flush to wall complete all as specified and directed MAKE- L&T Hagar Cat No - Y81122/ INDOASIAN Cat No - 811808/ LEGRAND cat No - 507612
S&F in replacement of old unserviceable Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way IP 43 (double door) with 100 Amps rated copper bus bar neutral bar ,earth bar ,single pole and neutral 250 volts ,flush to wall complete all as specified and directed MAKE- L&T Hagar Cat No - Y81082/ INDOASIAN Cat No - 811807/ LEGRAND cat No - 507611
S&F in replacement of old unserviceable MCBs double pole , 40 Amp 240 volt, C-curve 10 KA complete all as specified and directed.
S&F in replacement of old unserviceable MCBs single pole (SP), 10-32 Amp 240 volt C-curve 10 KA complete all as specified and directed.
S&F in replacement weather proof flat twin core cable aluminium conductor ISI marked , as per standard specifications, of size 10 Sqmm suitable for house service connection complete all as directed.
S&F energy efficient ceiling fans complete with blades, suitable size down rods, and connected accessories, 230 V, 1200 mm sweep. Min air delivery 225 CMM connecting with three core round lead 0.5 sqmm, three star rated including taking down existing ceiling fan complete all as directed. Make : Bajaj model - SPEEDSTER , Havells model - Samrat / Aeroking, Cromton and Orient Note:- Old U/S ceiling fan shall be deposite at MES store.
Taking down existing earthing of any description and M&L for new earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earthing wire 4mm dia size by means of GI bolts, nuts, check nuts and washers, earthing wire protected by GI pipe 20 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6) type C1 in chamber of size not less than 300x300x300mm (internal diamentions), RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover with angle iron 40X40X5mm frame etc complete all as specified and directed by Engineer-in-Charge. Note: The unit rate includes earthing wire and protection pipe upto maximum 7.5 metre from earth plate, earth point / test point.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil complete all as specifid and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.00 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.00 sq mm 4 core complete all as specified and directed.
M&L for river washed and screened dry sand for filling in trenches below and around underground cables for cushioning of cables etc complete all as specified and directed.
Supply & lay in trenches sub class `B’ bricks having compressive strength 75 Kg/ Sqcm for cable protection etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil complete all as specified and directed.
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Supply and lay in trench/floor/wall/hard standing GI pipe light grade 40 mm bore including its necessary fitting such as bends sockets etc for cable protection complete all as specified and directed.
Boring/drilling of wall or under road for passing of cable with protection pipe as per site requirement , complete all as specified and directed Note: Laying / fixing of pipe shall be measured and paid separately in connected item of this schedule
Alankar Traders
VINAYAK CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .