Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹84,600Qualified Make: havells
Model: HAVELLS 150 WATT SON/MH 06 RABINDRANATH TAGORE PARISAR SAKET NAGAR BHOPAL MADHYA PRADESH 462023 | BHOPAL | MADHYA PRADESH | 462023 | Make: havells
Model: HAVELLS 150 WATT SON/MH | L1 | Qualified | |
| 2 | L2₹85,000+₹400 (0.47%)Qualified Make: crompton
Model: Crompton 150 Watt HPSV BALLAST 21 C INDUSTRIAL ESTATE OPP POLICE LINE GANGA NAGAR | Make: crompton
Model: Crompton 150 Watt HPSV BALLAST | L2 | Qualified | |
| 3 | L3₹89,100+₹4,500 (5.32%)Qualified Make: crompton
Model: Crompton 150 Watt HPSV BALLAST HOUSE NO 03 AGRAWAL ELECTRICAL AND FURNITURE GULMOHAR COLONY NAHAR SAYAD ROAD MANDSAUR MANDSAUR MADHYA PRADESH 458001 | MANDSAUR | MADHYA PRADESH | 458001 | Make: crompton
Model: Crompton 150 Watt HPSV BALLAST | L3 | Qualified | |
| 4 | L4₹89,313+₹4,713 (5.57%)Qualified Make: BAJAJ
Model: BAJAJ 162109 BJOS150 SV/MH 4G CHOTTI SRI GANGANAGAR RAJASTHAN 335022 | GANGANAGAR | RAJASTHAN | 335022 | Make: BAJAJ
Model: BAJAJ 162109 BJOS150 SV/MH | L4 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
9 Jun 2018, 2:00 pmClosed
Lamp Ballast for HPSV Lamps Lamp Ballast For HPSV Lamps ( 100 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Ballast for HPSV lamps (Excluding Tubular Flourescent Lamps) conforming to IS: 15882:2009 and all the ballasts specified in the standard shall meet the requirements of IS: 15885(Part-1):2011 latest and IS: 15885(Pa rt-2/Section-9): 2011 latest Yes - ISI Marked Yes Yes ISI marked if yes declare CM/L Number If 'No' write NA NA - Ballast Wattage (in Watts) 150 W 150 W Operating Voltage 220 Volt -240 Volt - Supply frequency (in Hz) 50 Hz +/-5% - CONSTRUCTIONAL Ballast constructional requirements as per IS:15885 (Part 1) shall apply Yes - 1/4 Winding material Copper wound - Supply current: At rated voltage
the supply current shall not differ by more than 10 percent from the value marked on the ballast when the latter is operated with a reference lamp Yes - Current wave form shall be as per Cl 9 of IS:15882:2009 latst Yes - Magnetic screening: The ballast shall be effectively screened against the influence of adjacent ferro- magnetic materials as pe Cl 10 of IS:15882:2009 latest Yes - Ballast setting: Power delivered at rated voltage as per Cl. 15.1 of IS:15882:2009 latest (Not Less than 95% and not more than 105% of the reference ballast when operated at the objective lamp voltage as given in IS:9974(Part2) Yes - Short Circuit current between 92% and 106% of rated voltage as per Cl. 15.2 of IS:15882:2009 latest Yes - Open circuit voltage between 92% and 106% of its rated voltage as per Cl. 15.3 of IS:15882:2009 latest Yes - Insulation resistance as per Cl. 11 of IS:15885 Part 1 : 2011 latest >/=2 M Ohm - Electric strength as per Cl. 12 of IS:15885 Part 1 : 2011 latest Yes - Rated Maximum operating temperature of ballast (Tw) (Ref. Cl. B.9.2 of IS:15885 part 105 deg C - 2/4 1:2011 latest) Ballast shall pass the thermal endurance test for winding of ballast as per Cl.13 of IS:15885 Part 1 :2011 latest Yes - Ballast shall pass High voltage test 5 KV for 5 Seconds Yes - Watt Loss 19 Watts maximum for 150 W Ballast - Cold resistance at 20 deg. C (Tolerance: t+5%
10%) - must declare 15% - Circuit power factor >/=0.85 - WARRANTY Guaranteed period of replacement 1 Year - CERTIFICATION Marking: Apart from IS requirement each ballast shall be marked with serial number of ballast
Watt Loss
Tw details Yes - Availability of Type Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to IS specifications as appliacable Yes - Test Report Number NA - Test Report Date NA - Name of Test Lab NA - Address of Test Lab NA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sauna Oraon 841221
Office of the Chief Administrative officer
2nd Floor
Electrical Branch
Administrative Building
Rail Wheel Plant
Bela
PO Arvind Nagar
100 15 EMD 3/4 Required No ePBG Required No
146133
GEM/2018/B/20847
Lamp Ballast for HPSV Lamps
15 days
Bihar; Saran
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Lamp Ballast for HPSV Lamps Lamp Ballast For HPSV Lamps ( 100 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Ballast for HPSV lamps (Excluding Tubular Flourescent Lamps) conforming to IS: 15882:2009 and all the ballasts specified in the standard shall meet the requirements of IS: 15885(Part-1):2011 latest and IS: 15885(Pa rt-2/Section-9): 2011 latest Yes - ISI Marked Yes Yes ISI marked if yes declare CM/L Number If 'No' write NA NA - Ballast Wattage (in Watts) 150 W 150 W Operating Voltage 220 Volt -240 Volt - Supply frequency (in Hz) 50 Hz +/-5% - CONSTRUCTIONAL Ballast constructional requirements as per IS:15885 (Part 1) shall apply Yes - 1/4 Winding material Copper wound - Supply current: At rated voltage | - | - | - |
| the supply current shall not differ by more than 10 percent from the value marked on the ballast when the latter is operated with a reference lamp Yes - Current wave form shall be as per Cl 9 of IS:15882:2009 latst Yes - Magnetic screening: The ballast shall be effectively screened against the influence of adjacent ferro- magnetic materials as pe Cl 10 of IS:15882:2009 latest Yes - Ballast setting: Power delivered at rated voltage as per Cl. 15.1 of IS:15882:2009 latest (Not Less than 95% and not more than 105% of the reference ballast when operated at the objective lamp voltage as given in IS:9974(Part2) Yes - Short Circuit current between 92% and 106% of rated voltage as per Cl. 15.2 of IS:15882:2009 latest Yes - Open circuit voltage between 92% and 106% of its rated voltage as per Cl. 15.3 of IS:15882:2009 latest Yes - Insulation resistance as per Cl. 11 of IS:15885 Part 1 : 2011 latest >/=2 M Ohm - Electric strength as per Cl. 12 of IS:15885 Part 1 : 2011 latest Yes - Rated Maximum operating temperature of ballast (Tw) (Ref. Cl. B.9.2 of IS:15885 part 105 deg C - 2/4 1:2011 latest) Ballast shall pass the thermal endurance test for winding of ballast as per Cl.13 of IS:15885 Part 1 :2011 latest Yes - Ballast shall pass High voltage test 5 KV for 5 Seconds Yes - Watt Loss 19 Watts maximum for 150 W Ballast - Cold resistance at 20 deg. C (Tolerance: t+5% | - | - | - |
| 10%) - must declare 15% - Circuit power factor >/=0.85 - WARRANTY Guaranteed period of replacement 1 Year - CERTIFICATION Marking: Apart from IS requirement each ballast shall be marked with serial number of ballast | - | - | - |
| Watt Loss | - | - | - |
| Tw details Yes - Availability of Type Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to IS specifications as appliacable Yes - Test Report Number NA - Test Report Date NA - Name of Test Lab NA - Address of Test Lab NA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sauna Oraon 841221 | - | - | - |
| Office of the Chief Administrative officer | - | - | - |
| 2nd Floor | - | - | - |
| Electrical Branch | - | - | - |
| Administrative Building | - | - | - |
| Rail Wheel Plant | - | - | - |
| Bela | - | - | - |
| PO Arvind Nagar | - | - | - |
| 100 15 EMD 3/4 Required No ePBG Required No | - | - | - |
Exempted
9 Jun 2018
29 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_146133.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .