Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.6 CrAccepted-AOC | ₹9.6 Cr | 1 | Accepted-AOC Decided in ULHPPC |
| 2 | 2₹10.5 Cr+₹97.8 L (10.2%)Rejected-Finance 14 G F BLK B 5 MODEL TOWN DELHI DELHI 110009 | NORTH WEST DELHI | DELHI | 110009 | ₹10.5 Cr+₹97.8 L (10.2%) | 2 | Rejected-Finance Decided in ULHPPC meeting |
| 3 | 3₹11.0 Cr+₹1.4 Cr (14.9%)Rejected-Finance KHASRA NO 265 281 288 VILL PARSAUN DASNA P O JINDAL NAGAR DISTT HAPUR UP 201015 | HAPUR | HAPUR | UTTAR PRADESH | 201015 | ₹11.0 Cr+₹1.4 Cr (14.9%) | 3 | Rejected-Finance Decided in ULHPPC meeting |
| 4 | 4₹11.2 Cr+₹1.7 Cr (17.7%)Rejected-Finance | ₹11.2 Cr+₹1.7 Cr (17.7%) | 4 | Rejected-Finance Decided in ULHPPC meeting |
| 5 | 5₹11.5 Cr+₹1.9 Cr (20.2%)Rejected-Finance | ₹11.5 Cr+₹1.9 Cr (20.2%) | 5 | Rejected-Finance Decided in ULHPPC meeting |
Tender Value
₹9.6 Cr
EMD Value
₹19 L
Closing Date
1 Dec 2020, 5:00 pmClosed
SE Contracts
Shakti Bhawan, Sector-6, Panchkula
Creation of 66KV S/Stn. Sector-16 Part, HSVP, Jagadhari District Yamuna Nagar.
2020_HBC_145787_1
EPC-D 09 PD and C Dated 24.09.2020
Open Tender
Electrical Works
Turn-key
450 days
Sector-16 Part, HSVP, Jagadhari
As per Tender Documents
8 documents required · 8 mandatory
₹11,800
HVPNL
₹19 L
Yes
5 Jul 2021
25 Sept 2020
8 Dec 2020
25 Sept 2020
1 Dec 2020
25 Sept 2020
12.5/16MVA, 66/11kV T/Fs (to be provided by HVPNL)
25/31.5 MVA, 66/11kV T/Fs (to be provided by HVPNL)
Time synchronization equipment
66 kV SF-6 Breaker along with 20% extra SF-6 Gas
66 kV Isolator with E/Switch
66 kV Isolator without E/Switch
66 kV Surge Arrestor
66 kV CTs for Line & Bus Coupler (600-300-150/1-1-1A)
66 kV T/F CT (300-200-150/0.577-1-1A)
66 kV CVT for line
66 kV NCT (300-200-150/1A)
11 kV NCT (1800-900/5A)
11 kV 15 Panel Board (2000A) with one SEM on each T/F I/C Panel (including one no. bus sectionalizer panel)
11 kV 13 Panel Board (1250A) with one SEM on each T/F I/C Panel (including one no. bus sectionalizer panel)
66kV C&R Panels a) Bus Coupler Protection and Circuit Breaker Panel (Without Auto Reclose)
b) Line Protection and Circuit Breaker Panel (Without Auto Reclose)
c) Transformer Protection and Circuit Breaker Panel (Without Auto Reclose)
9000KVAR 11kV Automatically Switched Capacitor Bank along with allied equipment (controlled by one VCB)
4600 KVAR 11kV Automatically Switched Capacitor Bank along with allied equipment (controlled by one VCB)
220V 100AH Battery (VRLA)
220 V 100 AH Battery charger & D.C.D.B.
415 V LT AC Distribution Board 300 A
11/0.4 kV Station T/F 200 KVA
(a) 1.1 kV Copper Control Cable unarmoured for 66kV bays of size 7Cx4mm2, 4Cx4mm2, 2Cx4mm2,2Cx6mm2, 3Cx2.5mm2, 16Cx2.5mm2, 10Cx2.5mm2 & 7Cx2.5mm2 including junction box etc. refer Section-6 of copper & control cable & Section-7 for switchyard erection.
(b) Stainless steel MK (200 TB)
11 kV Power Cable XLPE 1C x1000mm2 for T/F to 11kV incomer with termination kit for both ends.
11 kV Power Cable XLPE 3C x 400sq mm for Capacitor Bank with termination kit for both ends
11 kV Power Cable XLPE 3C x 185sq mm for Capacitor Bank with termination kit for both ends
11 kV Power Cable XLPE 3C x 50 sq mm for station T/F with termination kit for both ends.
650/1100 Volts 3.5 core 240 mm2 aluminium power cable from Aux. T/F to ACDB
650/1100 Volt 3.5 core 70 mm2 aluminium cable for oil filtration set.
650/1100 Volt 4core 16mm2 unarmoured with copper power cable for MLDB and other cable required as per contract for 66kV bays.
Earthing Mat Material. The earth mat will be designed/ quoted for soil resistivity of 50ohm. In case soil resistivity is more than 50ohm then the earth mat will be designed for actual soil resistivity. The payment of extra material to be used for earth mat shall be made on pro rata basis. The approximate area of earth mat to be laid is given in the corresponding columns of the substations. However, item will remain a Lot item. (8200 sq.mm)
Fire Fighting equipments as per section-6 i. 22.5 Kg Capacity FE CO2 type, Trolley Mounted
ii. 25 Kg Capacity FE DCP type, Trolley Mounted
iii. DCP 10 Kg Capacity, Wall mounted
iv. FE CO2 6.5 Kg Capacity, Wall mounted
v. DCP 5 Kg Capacity, Wall mounted
vi. Foam Type 9 Litre Capacity, Wall mounted
vii.Water CO2 9 Litre, Wall mounted
viii. Fire Buckets (12 Nos. with stand in one set)
i. Complete lightning of control room building, switch yard area, road and street as per section-7 of the specification. Supply and installation of 2 fittings of 240W LED lamps with all accessories for Complete lighting of outdoor Switch yard area as per clause 16.0 of section 7 of the specifications.
ii. Supply and installation of 35W LED tube on tubular steel poles along with the boundary wall at a distance of 30 meter as per as per clause 16.0 of section 7 of the specification
iii. Complete lighting of road and street by providing 90W LED lamps on tubular steel poles at a distance of 15meter along the roads and streets as per as per clause 16.0 of section 7 of the specification.
iv. Supply and installation of post top lantern 40W LED Lamps with all complete accessories at the entrance gate of sub-station.
v. Supply and installation of 40W LED Lamps with all complete accessories on corners of control room building.
Complete Substation automation system of 66/11kV substations including hardware (along with transducers) for 8 No. 66kV present bays and software (for present bays as well as 2 No. future line bays) along with associated equipment for the bays (bay as defined in the technical specification, sec-sub-station automation system) as per technical specification Note: signals from protection relays in 11kV incomer would also be wired to substation automation system (SAS)
i. High wall type split AC unit of 2 Ton capacity for SCADA room (as per technical specification)
ii. High wall type split AC unit of 2 Ton capacity for C&R panels in electrical room.
Bolted type 11kV Single tension string assembly with 3 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and tension clamp sets suitable for twin tarantulla conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators (type of insulator whether disc or polymer insulator to be identified at the time of bidding and quoted accordingly which will not be altered at later stage by the bidder).
66 kV Bolted type single tension string assembly with 6 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connection and tension clamp set suitable for single zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators (type of insulator whether disc or polymer insulator to be identified at the time of bidding and quoted accordingly which will not be altered at later stage by the bidder).
66 kV bolted type single suspension string assembly with 5 numbers Anti FOG type disc insulators (E&M strength 9000 kg) per string with all hardware accessories including ball & socket connections and suspension clamp set suitable for single zebra conductor. Alternatively the bidder may quote silicon polymer composite insulator string in place of Disc Insulators (type of insulator whether disc or polymer insulator to be identified at the time of bidding and quoted accordingly which will not be altered at later stage by the bidder).
Boltless C-Type Wedge connectors matching with conductor size.
Copper lugs glands, PVC ferrules for control cabling.
Fibre cleats, Aluminium clamps, bolts, nuts, washers etc., for fixing control cables in trenches.
Galvanized iron perforated tray with side coupler plate bolts, nuts, washers and clamps etc. of size 75x25x2 mm, 150x25x2mm, 100x25x2mm etc. & G.I. Conduits of 50mm/100mm dia from equipment to main trench as per Section-7, Switchyard erection.
ACSR Zebra Conductor
AAC Tarantulla Conductor
7/3.15 GS Earthwire ( to be supplied by HVPNL , item lying in DD store, panipat)
Spacers for Twin Tarantulla Conductor
U-bolt 20mm dia
Mandatory spares for hardware/ mechanical/ Electrical auxiliaries to be supplied. 10 % of the finally approved quantities for item mentioned from Sr. No. 51 to 53.
‘Lattice type steel structure for 66kV S/Stn. Sector-16 Part,HSVP Jagadhari. Supply of material, preparation of fabrication drawing, galvanizing and delivery of lattice type steel structure for tower and beams for 66/11KV switchyard fabricated from steel conforming to IS:2062 including nuts-bolts gusset plates foundation bolts and other accessories as per drawings supplied by the owner. Main S/Stn. tower and beam a). Tower type CT-4
b). Tower type CT-5
c). Tower type CT-6
d). Tower type CT-8
e). Beam type CB-6
f). Beam type CB-7
g).Tower type DT-2
h). Tower type DT-3
i).Beam type DB-2X
Equipment Structure a) 66 kV CT Drg. No. HTD/ST-88R
b) 66 kV NCT Drg. No.HTD/ST-145 (if required )
c) 66 kV CVT Drg. No. HHW/ST-66
d) 66 kV Surge Arrestor Drg. No. HTD/ST-89
e) 66 kV Isolator Drg. No. HTD/ST-87R
f) 66 kV L&E Switch Drg. HTD/ST-87R
g) 11 kV NCT Drg. HTD/ST-149( if combined structure used )
1. EARTH WORK 1.1) Earth filling with good earth (as per satisfaction of Executive Engineer/Civil Works Division), laying in layers (as per specification), dressing, including carriage, irrespective of lead, loading, unloading, watering and compaction in layers with roller including compensation of earth complete in all respect.
2. FOUNDATIONS Supply of labour, T&P, material and construction of RCC footings & pedestals etc. for steel gantry and equipment structures complete in all respects as per technical specifications & drawings attached with the tender document including cost of excavation, concreting, cement, reinforcement steel, form work, grouting, holding down bolts, backfilling etc. and other items not mentioned herein but required for the completion of work. A. GANTRY TOWERS 66kV side i) CT-4
iii) CT-6
33kV side i) DT-2
B. EQUIPMENT 66kV side i) 66KV LA
ii) 66KV CVT
iii) 66KV NCT
iv) 66kV CT
v) 66kV L&E & Isolator
11kV side i) 11kV NCT
3. BREAKER FOUNDATION Design, engineering, supply of labour, material, equipment & const. of foundations for 66kV SF-6 circuit breaker including all associated works PCC, RCC, structural steel, steel reinforcement & any other item not specifically mentioned herein but reqd. for completion of work as per tech. spec.
4. CAPACITOR BANK FOUNDATIONS Design, Engg. & supply of labour, material & construction of foundations for following rating capacitor bank with capacitor unit (with allied equipments) & series Reactor etc. including chain link fencing 1.8M height around cap. bank complete in all respect including any other items not specifically mentioned herein but required for completion of job as per technical specification. i) 9000KVAR 11kV Capacitor Bank
ii) 4600KVAR 11kV Capacitor Bank
5.TRANSFORMER FOUNDATION Design, Engg., supply of labour, material and construction of T/F foundation including radiator foundations etc. complete transformer foundations including all associated works, RCC, PCC, Reinforcement steel, misc. structural steel and other items not mentioned herein but required for the completion of work as per technical specifications and HVPNL drawing. In case additional foundation is/are required as per approved equipment drawing, the same shall be constructed by the successful bidder without any extra cost to HVPNL. Such drawing(s) shall, however, be got approved from HVPNL. i) 11/0.4kV 200KVA Station T/F
Construction of transformer foundation including all associated works, RCC, PCC, reinforcement steel, misc. structural steel and other items not mentioned herein but required for completion of work as per technical specifications & drawing attached. In case extra foundation(s) has/have to be constructed (as per approved T/F drawing) to complete the job, nothing extra would be paid on this count. i) 25/31.5MVA, 66/11kV T/F foundation
ii) 12.5/16 MVA 66/11 kV T/F Foundation
6. CABLE TRENCHES Supply of labour, material such as cement, reinforcement steel, GI angles, flats, PCC & brick pillars below cable trenches for construction of Out-Door Cable Trenches (ODCT) of required depth/ type with pre-cast RCC covers including associated works like Cable Trench Culverts crossings for roads and sump- pit-cum-pump chamber with 2HP motor of reputed make, starter, volt meter, amp-meter etc. as per approved Trench layout plan, HVPNL drgs. & tech. specs. complete in all respect.
7. SITE SURFACING 7.1) Providing, supplying and laying 100mm thick PCC (1:4:8) using 20mm nominal coarse aggregates and spreading 100mm thick layer of 40mm nominal size uncrushed/crushed/ broken stone pebbles over the PCC including construction of toe wall (exposed wall plastered with cement mortar 1:5) to hold 40mm single size uncrushed/ crushed/broken stone pebbles wherever required in the bays covered under the present scope as detailed in the GELO & instructions of concerned Executive Engineer/Civil Works Division.
7.2) Providing, supplying & laying two layers of uncrushed/crushed/broken stone/ pebbles gravel fill. The first layer after compaction shall make min. 50mm thickness course/layer of 40mm nominal size, including dressing, rolling & compaction complete as per specs., GELO and instructions of XEN/CWD.
8. ROADS & PCC PAVEMENT Supply of labour, material and construction of cement concrete roads and walkways/shoulders from NH/SH/etc. to Switch yard/Switch house building as per GELO/CLO as per sectional detail drawing no. HCD/SK-181 R1 and technical specification. i) 6.0M wide
ii) 3.66M wide
iii) PCC in front and rear of parking area of SH Building as per tech. specification and drawing HCD/SK-172.
9. ROAD CULVERTS Design, Engineering and const. of Pipe culvert(s) at suitable locations under the approach road (from main PWD/ HUDA/Municipal/Village road to the sub-station entry point) including, cost of labour, material complete in all respects as per I.R.C. Standards.
10. BOUNDARY WALL 10.1 Supply of labour, material and construction of front, C & U/C boundary walls including main gate foundations as per GELO/CLO, technical specifications. & HVPNL drg. HCD/TS-1176 R1 including excavation backfilling, lean & DPC complete in all respect. i) 6 ft. high with GI barbed wire on angles at top.
ii) 4½ ft. high front wall with grill at top.
iii) 4½ ft. side wall with GI barbed wire
10.2 Supply of labour, T&P, material and construction of front, side & U/C boundary walls including main gate(s) (brickwork below DPC level) as per GELO/CLO, tech. spec. & HVPNL drawings complete in all respects.
11. U/C FENCING & GATES Providing & fixing chain link fencing including foundations, GI angle iron posts and gate(s) complete as per electrical layout & tech. spec. & as per drawing attached.
12. DRAINAGE–CUM-RAIN HARVESTING SYSTEM 12.1) Supply of labour, material for construction of 1 no. recharge structure with bore well as per HVPN drawings & specs. complete in all respect. The location of recharge structure shall preferably be located on corner(s) of the substation and shall be got decided from the concerned XEN/Civil Works Division on the basis of surroundings of the substation(s). In case ground water table is less than 8m from FGL, rain harvesting well shall not be constructed (the drainage system with sump pit is to be constructed as per item mentioned below).
12.2) The successful bidder shall evolve design & drawing for drain, manholes with RCC covers and settlement tank including preparation of drainage layout drawing for disposal of rain water from building’s roof top & switch yard (s/stn.) area into bore well in such a way that there shall be no ponding of water on the roof and switch yard (s/stn.). The layout so developed shall be got approved from the employer. The location of sump-pit-cum-pump chamber shall preferably be located on corner(s) of the s/stn. and shall be got decided from the concerned XEN/Civil Works Division on the basis of surroundings of the substation(s). The successful bidder will also supply labour and material for construction of 1 no. sump-pit-cum-pump chamber as per HVPNL drgs. & provide one no. non clog pump(s) of 5HP of reputed make capacity with main switch, starter, volt meter, Amp. Mtr. etc. (for each sump pit) for disposal of excess water to outfall point. Any other item(s) not mentioned herein but is/are required for completion of works shall be done by the successful bidder without any extra cost to the employer.
13. CONTROL ROOM BUILDING Supply of labour, material & construction of control room building complete in all respect as per tech. specs. & approved drgs. attached including exterior & interior acrylic emulsion paint, all internal services like water supply including supply & providing of 5000ltr. capacity triple layered Sintex/Diplast PVC tank, sewerage system, staircase, electrification including wiring, modular switches, maximum 20W 4ft. long LED tubes with fittings minimum 1960 lumens, ceiling/exhaust fans & 4 no. 2T split ACs, finishing, plinth protection, indoor trenches, trench covers, soakage pit near the switch house building, connection of sewerage system to Soakage pit/Sewerage system of local authorities (as applicable), connection to main water supply system of local authority/ submersible bore (as applicable) etc. & any other item not mentioned herein but reqd. for completion of works. The successful bidder shall also provide water supply connection from bore well/HUDA/Municipal /Public Health or Panchyat water supply scheme (as per available source of portable water) to the control room bldgs. without any extra cost of HVPNL.
14. RCC M-20 inclusive of labour, material, shuttering, Steel reinforcement etc. complete in all respects to compensate excess quantity required to be executed due to difference in existing ground level and the formation level to be fixed after contouring or difference on account of revised drg issued at the time of construction and the tender drg.
15. RCC ANTI-FIRE WALL Construction of RCC anti fire wall of suitable height between 66/11kV T/Fs as per HVPNL drawing no. HCD/TS-1106 R1(COM) and all associated works including supply of labour, material, cement, reinforcement steel, steel form work etc. as per tech. spec.
sumaja electroinfra pvt ltd
SALASAR TECHNO ENGINEERING LIMITED
Modern Transformers Pvt. Ltd.
Telmos Electronics
HITECH ERECTORS PVT. LTD.
SRIHARI CONSTRUCTIONS
Hartek Power Private
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .