Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC D NO 9 947 66 DOCTORS COLONY SHIVAJI PLEM VISAKHAPATNAM 530017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹7.8 L+₹8,270 (1.07%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹8.7 L+₹1.0 L (13.3%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹9.9 L+₹2.2 L (28.0%)Rejected-Finance | L4 | Rejected-Finance Being not L1 |
Tender Value
₹9.4 L
EMD Value
₹18,900
Closing Date
9 Dec 2021, 6:00 pmClosed
Shri Akash Agrawal, IDSE AEE AGE (I) R and D NSTL
AGE (I) R and D, NSTL Complex, Visakhapatnam 530027
8357 REPAIRS / REPLACEMENT OFDAMAGED COMPONENTS AND ACCESSORIES OF CENTRAL / PACKGE TYPE , SPLIT / WINDOW TYPE ACs AND WATER COOLERS IN VARIOUS TECHNICAL BUILDINGSAT DRDL KLINGA UNDER AGE (I) RnD NSTL, VISAKHAPATNAM
2021_MES_487575_1
AGE I R AND D NSTL VIZAG 8357
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Visakhapatnam
Class E Category c i
7 documents required · 7 mandatory
₹500
AGE I R and D NSTL Visakhapatnam
₹18,900
Yes
10 Feb 2022
11 Nov 2021
11 Dec 2021
11 Nov 2021
9 Dec 2021
25 Nov 2021
Amount
M & L for cleaning/ servicing the cooling coil of AHU of 140 TR AC plant at VIB - I and MCC Bldg (4 units) by air pressure method using air blower and cleaning the cooling coil with suitable cleaning agent, cleaning the AHU base tray completely and applying one coat of synthetic enamel paint inside the base tray, including greasing to AHU blower shaft bearing for smooth functioning, cleaning the AHU filter, replacement of unserviceable V belts etc. all as directed. Note:- V belts shall be measured and paid separately as supply only under respective items of this Schedule.
ll as per Item No. 1 herein before but for 60 TR capacity plant at MS Bldg (02 unit)
All as per Item No. 1 herein before but for 300 TR capacity plant at VIB - II, MPPTF, ASH - I & ASH - II (3 units)
M&L for cleaning/ servicing of cooling tower, natural draught type/ FRP type of 140 TR AC plant VIB - I and MCC Bldg including cleaning of wooden/ PVC/ FRP louvers by scraping inside and outside, cleaning of water tank, cleaning and replacement of damaged/ choked nozzles, replacement of PVC pipe n. exc. 3 mtr in length; arranging, refixing in position of all louvers in correct manner and applying one coat of black bituminous paint inside and outside of water tank, replacement of float valves with new one, cleaning of CT Fan blades, replacement of corroded nuts and bolts as per existing size including replacement of damaged/ broken louvers and unserviceable nozzles all as specified and as directed.
M&L for complete leak testing the entire central AC plant of any capcity above 60TR and up to 140 TR per unit consisting of compressors, condensers, chillers, AHUs with connected chilled piping, expansion valves and all accessories by flushing out the refrigerant gas present in the system, pumping Nitrogen gas at requisite pressure, locating leak positions, rectifying the leaks, including pressure testing and holding the pressure for 48 Hrs for observation for any pressure drop in the system and flushing out the complete system on rectification of leaks if any, vaccumising & de-hydration the complete system with heavy duty vaccum pump and removal of moisture and other foreign particles from the system complete including checking of all safety controls and parameters, testing & commissioning of the AC plant after charging the refrigerant gas all as directed by the Engineer-in-Charge. [Note: Supply only refrigerant gas will be measured and paid separately]
M&L for complete leak testing the entire central AC plant of any capcity above 140 TR and up to 300 TR per unit consisting of compressors, condensers, chillers, AHUs with connected chilled piping, expansion valves and all accessories by flushing out the refrigerant gas present in the system, pumping Nitrogen gas at requisite pressure, locating leak positions, rectifying the leaks, including pressure testing and holding the pressure for 48 Hrs for observation for any pressure drop in the system and flushing out the complete system on rectification of leaks if any, vacuumising & de-hydration the complete system with heavy duty vacuum pump and removal of moisture and other foreign particles from the system complete including checking of all safety controls and parameters, testing & commissioning of the AC plant after charging the refrigerant gas all as directed by the Engineer-in-Charge. [Note: Supply & charging refrigerant gas will be measured and paid separately]
Descaling of 60 TR (3 x 22 TR) capacity at K - 4 Bldg Package AC Plant complete condensors (outdoor unit) , evaprators (indoor unit), with connected chilled/gas piping, expansion valves and all accessories complete with descaling chemical and filters with fresh water all as specified and directed.
Material & Labour for complete leak testing the entire Package AC plant system consisting of 60 TR (3 x 22 TR) capacity consisting of variour makes for compressors, condensors, evaprators, with connected chilled/gas piping, expansion valves and all accessories complete with Nitrogen gas, locating leaks positions, rectifing the leaks and flushing out the complete system including pressure testing and holding the pressure for 48 Hrs for observation for any pressure drop in the system and rectifying complete and filling the regrigrent gas to desired pressure and testing complete all as directed by the Engr in charge
Removal of complete corrosion of body and electrical connections of Package Plant 3 x 22 TR (Blue Star) and applying two coats of synthetic enemel paint over a coat of redoxide primer without damaging the existing auxilaries/ pipe lines and electrical connections and complete fxing of the compressor / condnser unit fan controll units and testing complete all as specified and directed.
M&L for Disconnecting electrically and mechanically mono-block pump set of 30 HP capacity of any make from the existing position by arranging dummy plates to suction and delivery line, removing from the existing position, opening up, varnishing to stator winding with class I varnish, heating/ baking the same, removal of damaged motor bearing, cleaning the rotor and re assembling the motor, cleaning the impeller of pump, supply & replacement of shaft bearings, gland rope, gland bolts & nuts, greasing the pump bearing, fixing back at original location with proper alignment, connecting and testing complete all as specified..
All as per Item No. 10 herein before but of 5 / 7.5 HP capacity
M & L for disconnecting/ Dismantlig (electrically & mechanically) 3 phase, 440 volts, 50 Hz electrical motor from the monoblock pump set of 30 HP capacity and shifting to workshop, opening the motor end cover, taking out rotor, taking out burnt stator winding, cleaning the stator and rewinding the motor with appropriate gauge, weight and turns of super enamelled copper wire using proper insulating material, varnishing with Class-I varnish, heating/ baking, reassembling the motor completely and brought back to site, fixing back duly coupled with the pump in prope aignment, connecting and testing complete all as specified. Note: Insulation of windng shall be Class 'B' upto 7.5 HP and Class 'F' for 10 HP and above.
All as per Item No 12 here-in-before but of 5/7.5 HP Capacity .
Supply only Wedge (V) Belts B - 134 for compressor & motor/ AHU & motor. [Make: Fenner/ Yule/ ContiTech]
Supply only Wedge (V) Belts B - 95 for compressor & motor/ AHU & motor. [Make: Fenner/ Yule/ ContiTech]
Supply only Wedge (V) Belts B-2253 LP /B87 for compressor & motor/ AHU & motor. [Make: Fenner/ Yule/ ContiTech]
S&F in repairs Single phase preventer Heavy duty relay for protection against single phasing, phase reversal condition, unbalance condition, with inbuilt timer working on 440V, 50Hz power supply complete all as specified and directed. [Make: Minilec 3NA-30-323 or equivalent in Siemens]
S&F in repairs Starter Push Button switch with 1 NO + 1 NC complete working on DC/ AC supply up to 16 Amps capacity all as specified and as directed. [Make: L&T ESBEE/ Siemens]
S&F in repairs 4 pole contactors AC operated rating at 415 Volts, AC1 45 Amps rating with 2NO + 2NC auxiliary contacts with operatabe coil voltage 24 volts to 415 volts AC/DC with front/ side mounted Add On blocks as per site requirement. [Make: ABB/ Siemens/ Schneider/ L&T]
All as per Item No. 20 herein before but of AC1 rating 30 Amps.
All as per Item No. 20 herein before but of AC1 rating 60 Amps.
S&F in repairs Thermal Overload relay, 18 to 42 Amps, direct mounted on contactors. [TA42DU series of make: ABB or equivalent in GE/ L&T]
S&F in repairs Thermal Overload relay, 22 to 80 Amps, direct mounted on contactors [TA75DU series of make: ABB or equivalent in GE/ L&T]
Supply only Refrigerant gas 'R- 22' in manufacturer's sealed cylinder.
Supply only Refrigerant gas 'R- 134a' in manufacturer's sealed cylinder. Note for Sl. item No 25 & 26:- (i) Empty cylinder will be returned to contractor on completion of work (ii) Net weight of refrigerant gas shall be measured and paid under these items
Supply only compressor oil all as directed by Engr in charge
S&F 25 mm bore ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed in repairs. [Make: Leader/ Zoloto/ Lakshmi/ Sakthi]
M&L for carrying out repairs to PCB board with flexible cards by replacing the damaged/ worn-out electronic components/ ICs with heat sinks, programming automation complete for Central AC plants of various capacities from 70 TR to 160 TR complete including testing and commissioning all as directed.
S&F in repairs pneumatic safety valve for condensers of central AC plants of capacity 35 / 40 / 60 / 80/ 120 / 140 TR. [Make: Castle/ Brassolite/ Henry]
S&F in repairs flow control limit switch/ sensor as per the existing make/ model complete all as specified and as directed. [Make: Castle/ Rapid controls/ Honeywell]
Supply and fixing of water pressure meter dial type up to 7 Kg/cm2 complete all as specified and directed. Make: Guru/Danfoss
Supply and fixing of temperature meter dail type with stop valve 0 to 30 degree centigrade with complete acessories by removing of the old unserviceable meter complete all as specified and directed. Make: H- guru / danfoss/ universal
Removal of the damaged HP cut out, supply and fixing of High Pressure cut out on the compressed / pressurised gas lines complete all as specified and directed.
Removal of the damaged LP cut out, supply and fixing of Low Pressure cut out on the compressed / pressurised gas lines complete all as specified and directed.
Removing of the defective unserviceable temperature sensor and supply and fixing of temprature sensor / thermostat controller along with necessary controll wiring and acessories. Make: Simens/ Honey well
Removing of the defective unserviceable humidity sensor and supply and fixing of humidity sensor/ controller along with necessary controll wiring and acessories. Make: Simens/ Honey well
M&L for painting the entire Package screw type plant of the following capacities consisting of compressor units, condenser units,control panel, LT Panel (Power supply) , pumps and suction/disharge pipe lines by scrapping and cleaning the old painted surfaces, removing grease/ oil stains with cleaning agents and applying two coats of synthetic enamel paint of approved tint all as specified and as directed. (i) VIB - II, MPPTF, ASH - I & ASH - II Package Plant 300 TR (Blue star)
All as per Item No. 38 herein before but MS bldg 60 TR capacity
All as per Item No. 38 herein before but VIB - I and MCC Bldg 140 TR capacity
Supply and replace Balancing valve, of suitable size, 3 way moduling valve alongwith thermostat actuator and necessary control wiring complete all as directed.
Supply only sealed compressor unit working on 230 Volts AC supply suitable for 1.5 TR window/ split type AC of any make/ model. [Make: Carrier/ Hitachi/ Tekumseh/ Usha/ Voltas/ Blue Star]
Supply only sealed compressor unit working on 230 Volts AC supply suitable for 2 TR window/ split type AC of any make/ model. [Make: Carrier/ Hitachi/ Tekumseh/ Usha/ Voltas/ Blue Star]
Supply only cooling coil unit suitable for 1.5/2 TR split type AC of any make/ model. [Make: As per OEM]
Supply only Copper condenser unit suitable for 1.5/ 2 TR split type AC of any make/ model. [Make: As per OEM]
Supply only starting capacitor of 45 mfd capacity for 1.5 TR capacity window/ split type AC. [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only starting capacitor of 50 mfd capacity for 2 TR capacity window/ split type AC. [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only suction valve of size 5/8" as required
Supply only discharge valve of size 1/4" as required
Supply only blower motor double shaft, single/double speed, single phase, AC 230 V of 1/6 to 1/4 HP capacity to suit the existing window type AC all as directed. [Make: As per OEM]
Supply only blower motor single shaft, single/double speed, single phase, AC, 230 V of 1/8 to 1/5 HP capacity to suit the out door unit of split type AC all as directed. [Make: As per OEM]
Supply only blower motor single shaft, single/double speed, single phase, AC, 230 V suitable for indoor unit of split type AC of 1.5/ 2.0 TR capacity all as directed. [Make: As per OEM]
Supply only fan blade set suitable for window/ split type AC of any capacity.
Supply only remote control with PC board complete suitable for existing model of split type AC of any capacity. [Make: As per OEM]
Supply only fan motor capacitor of 2 mfd capacity [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only fan motor capacitor of 4 mfd capacity [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only fan motor capacitor of 6 mfd capacity [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only set of MS Powder coated mounting brackets for 1.5/ 2.0 TR AC Outdoor unit, heavy duty including necessary expansion fasteners.
Carrying out repairs to PCBs of indoor/ outdoor unit of split type AC of any make/ capacity complete all as directed.
Disconnecting and Taking down outdoor unit of split Acs of 1.5/2 TR capacity, dismantling the shell, scrapping old painted steel surfaces to remove rust and painting the surfaces with two coats of synthetic enamel paint and assembling, refixing the unit and connecting up complete all as specified and directed.
Supply only power transformer suitable for split/window Acs coplete all as specified and directed.
Supply only 1/2''X1/4'' dia copper pipe including tubular heat/cold resistant rubber pipe / foam type insulation complete all as specified and directed. Note:- 01 Meter of 1/2''copper pipe,01 Meter of 1/4'' dia copper pipe,01 Meter PVC corrugated pipe shall be measured as one unit length.
Supply only fare nuts of size 5/8'' made out of brass complete all as specified and directed.
All as per above item No. 63 but 1/2'' complete all as specified and directed.
All as per above item No. 63 but 1/4'' complete all as specified and directed.
Supply only 5/8''X1/4'' dia tubular heat/cold resistant nitrile rubber pipe / foam type insulation complete for fixng from indoor to outdoor units of split AC all as specified and directed. Note:- 01 Meter of 5/8''internal dia ,01 Meter of 1/4'' internal dia shall be measured as one unit length.
Supply and Valve dummy caps made up of Brass of size 5/8"
Supply and Valve dummy caps made up of Brass of size 1/2"
Supply only PVC Pipe of 65 mm dia of density 6kg/mtr for fixing between indoor and out door units inside the walls of appropriate lengths and closing the balance holes with PCC/Birla white/Glass putty and making the surface finishes even as directed by the engineer in charge
Supply only sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 Volts all as specified. [Make: Legrand/ Standard/ L&T]
Supply only metal plug top 15 Amps. [Make: Anchor/ Cona/ GM]
M & L for rewinding of Outdoor/ indoor motor of split type AC or blower motor of window type AC
Supply only starting capacitor of 60 mfd capacity for water cooler. [Make: Usha/ Universal/ Elcaps/ Tibcon/ Keltron]
Supply only condenser fan motor, single shaft 1/35 HP capacity, working on single phase, 230V AC for water cooler. [Make: As per OEM]
Supply only fan blade set suitable for water cooler of any capacity.
Supply only 15mm dia PVC flexible pipe 600mm long complete for water cooler of any capacity. [Make: Prayag/ Water Tec]
Supply only Nitrogen gas in manufacturer's sealed cylinder for leak testing. [Note:- (i) Empty cylinder will be returned to contractor on completion of work. (ii) Net weight of Nitrogen gas ishall be measured and paid.]
LAKSHMI SAI CONSTRUCTIONS
suresh electricals
COOL CONTROL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .