Near Roadways Pilibhit
The Increasing Capacity of over loaded Distribution Transformers from 100 KVA to 250 KVA at location of Surbhi colony Pilibhit Khalsa Rice mill Puranpur Aman Banquet Hall Bisalpur and Bamroli Bilsanda Bisalpur in Summer Plan Bussiness Plan 2022-23
2022_MVVNL_692113_1
T-03/EDCP/2022-23
Open Tender
Miscellaneous Works
Item Rate
30 days
Puranpur, Bisalpur
As per tender form
3 documents required · 3 mandatory
₹1,180
EE EDD
₹2,500
24 Sept 2022
23 Apr 2022
30 Apr 2022
23 Apr 2022
30 Apr 2022
23 Apr 2022
180 days
Amount
Safe carriage of following materials from Store Centre-Pilibhit to Surbhi colony 11 KV Chatri chauraha feeder under 33/11 KV S/S store Centre-Pilibhit including loading & unloading up to 0-5 Km.
11/0.4 KV, 250 KVA T/F.
Other Material As:- (1) LT PVC Cable 1x240 sq. mm- 48 mtr. , (2) Al lugs for suitable 240 sq mm cable- 12 nos., (3) 3 phase D O Fuse – 1 no.
Opening/Dismantling of all connections from 100 KVA transformer and safe carriage from site to store centre-Pilibhit including loading & unloading.
Construction of 250 KVA T/Fs plinth for 250 KVA T/F of size 5 fit x5 fit x5 fit with the help of first class bricks, cement & coarse sand as per norms. Filling the structure completely by brick blast & plastering work of walls Including CC work on top in ratio 1:2:4 by cement, stone grit & sand and grouting of 2 nos. M.S. channel of size 50x50x5 mm on the top of T/Fs plinth whole work should be done as per RESSPO norms complete in all respect. (All Material will be provided by Contractor own his cost).
Mounting of 250 KVA T/F on newly constructed plinth, laying of cable jumpering and making all HT/LT connections complete work in all respect.
Fabrication and grouting of wire mesh fencing of 28 fit running length in rectangular shape height 2 meter with M.S. angle of size 50x50x06 mm. including gate at one side as per norms complete work and painting of same with 2 coats of red oxide and 2 coats of synthetic enamale paint. (All Material will be provided by Contractor own his cost).
Earthing of T/Fs by boaring type up to water level by providing GI pipe and making connection from boaring site to body and neutral of T/F. (All Material will be provided by Contractor own his cost).
Safe carriage of following materials from Store Centre-Pilibhit to Khalsa rice mill 11 KV town feeder no.-4 under 33/11 KV S/S Puranpur town including loading & unloading up to 0-50 Km.
11/0.4 KV, 250 KVA T/F.
Other Material As:- (1) LT PVC Cable 1x240 sq. mm- 48 mtr. , (2) Al lugs for suitable 240 sq mm cable- 12 nos., (3) 3 phase D O Fuse – 1 no.
Opening/Dismantling of all connections from 100 KVA transformer and safe carriage from site to store centre-Pilibhit including loading & unloading.
Construction of 250 KVA T/Fs plinth for 250 KVA T/F of size 5 fit x5 fit x5 fit with the help of first class bricks, cement & coarse sand as per norms. Filling the structure completely by brick blast & plastering work of walls Including CC work on top in ratio 1:2:4 by cement, stone grit & sand and grouting of 2 nos. M.S. channel of size 50x50x5 mm on the top of T/Fs plinth whole work should be done as per RESSPO norms complete in all respect. (All Material will be provided by Contractor own his cost).
Mounting of 250 KVA T/F on newly constructed plinth, laying of cable jumpering and making all HT/LT connections complete work in all respect.
Fabrication and grouting of wire mesh fencing of 28 fit running length in rectangular shape height 2 meter with M.S. angle of size 50x50x06 mm. including gate at one side as per norms complete work and painting of same with 2 coats of red oxide and 2 coats of synthetic enamale paint. (All Material will be provided by Contractor own his cost).
Earthing of T/Fs by boaring type up to water level by providing GI pipe and making connection from boaring site to body and neutral of T/F. (All Material will be provided by Contractor own his cost).
Safe carriage of following materials from Store Centre-Pilibhit to Bamroli 11 KV Bamroli feeder under 33/11 KV S/S Bilsanda including loading & unloading up to 0-60 Km.
11/0.4 KV, 250 KVA T/F.
Other Material As:- (1) LT PVC Cable 1x240 sq. mm- 48 mtr. , (2) Al lugs for suitable 240 sq mm cable- 12 nos., (3) 3 phase D O Fuse – 1 no.
Opening/Dismantling of all connections from 100 KVA transformer and safe carriage from site to store centre-Pilibhit including loading & unloading.
Construction of 250 KVA T/Fs plinth for 250 KVA T/F of size 5 fit x5 fit x5 fit with the help of first class bricks, cement & coarse sand as per norms. Filling the structure completely by brick blast & plastering work of walls Including CC work on top in ratio 1:2:4 by cement, stone grit & sand and grouting of 2 nos. M.S. channel of size 50x50x5 mm on the top of T/Fs plinth whole work should be done as per RESSPO norms complete in all respect. (All Material will be provided by Contractor own his cost).
Mounting of 250 KVA T/F on newly constructed plinth, laying of cable jumpering and making all HT/LT connections complete work in all respect.
Fabrication and grouting of wire mesh fencing of 28 fit running length in rectangular shape height 2 meter with M.S. angle of size 50x50x06 mm. including gate at one side as per norms complete work and painting of same with 2 coats of red oxide and 2 coats of synthetic enamale paint. (All Material will be provided by Contractor own his cost).
Earthing of T/Fs by boaring type up to water level by providing GI pipe and making connection from boaring site to body and neutral of T/F. (All Material will be provided by Contractor own his cost).
Safe carriage of following materials from Store Centre-Pilibhit to Aman banquet hall 11 KV Tikunia feeder under 33/11 KV S/S Bilsanda including loading & unloading up to 0-60 Km.
11/0.4 KV, 250 KVA T/F.
Other Material As:- AL. LT PVC Cable of size 1x240 Sq. mm. & Arial Bunch Cable of size 3x95+1x70+1x16 etc.
Safe carriage of release 100 KVA transformer from site to store centre-Pilibhit including loading & unloading.
Construction of 250 KVA T/Fs plinth for 250 KVA T/F of size 5 fit x5 fit x5 fit with the help of first class bricks, cement & coarse sand as per norms. Filling the structure completely by brick blast & plastering work of walls Including CC work on top in ratio 1:2:4 by cement, stone grit & sand and grouting of 2 nos. M.S. channel of size 50x50x5 mm on the top of T/Fs plinth whole work should be done as per RESSPO norms complete in all respect. (All Material will be provided by Contractor own his cost).
Mounting of 250 KVA T/F on newly constructed plinth, laying of cable jumpering and making all HT/LT connections complete work in all respect.
Fabrication and grouting of wire mesh fencing of 28 fit running length in rectangular shape height 2 meter with M.S. angle of size 50x50x06 mm. including gate at one side as per norms complete work and painting of same with 2 coats of red oxide and 2 coats of synthetic enamale paint. (All Material will be provided by Contractor own his cost).
Earthing of T/Fs by boaring type up to water level by providing GI pipe and making connection from boaring site to body and neutral of T/F. (All Material will be provided by Contractor own his cost).
M/s Mishra Traders
NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .