Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.8 LAccepted-Finance 15 JOGENDRA NATH GHOSAL ROAD P S BELGARIA KOLKATA 700 057 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700057 | 1 | Accepted-Finance ADMITTED | |
| 2 | 2₹16.5 L+₹1.7 L (11.4%)Accepted-Finance | 2 | Accepted-Finance ADMITTED | |
| 3 | Rejected-Technical | - | Rejected-Technical NIT CRITERIA NOT FULFILLED, NOT IN CATEGORY | |
| 4 | Rejected-Technical | - | Rejected-Technical NIT CRITERIA NOT FULFILLED, NOT IN CATEGORY |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
30 Sept 2021, 6:00 pmClosed
Garrison Engineer
GE I P Fy ISHAPORE, PO NAWABGANJ, DIST 24 PGS N WB-743144
As per tender documents
2021_MES_463777_3
8679/2021-22/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE I P FY ISHAPORE
Class E Category c(I)
6 documents required · 6 mandatory
₹500
GE I P FY ISHAPORE
₹36,000
Yes
18 Oct 2021
16 Sept 2021
1 Oct 2021
16 Sept 2021
30 Sept 2021
16 Sept 2021
16 Sept 2021 - 23 Sept 2021
Amount
INTERNAL ELECTRIFICATION
Repair, maintenance and servicing of packaged type AC unit of capacity incl taking out existing packaged type AC unit carefully by disconnecting existing electrical connection, removing aside, packing and cleaning with blower & soap solution making dust free to the system, tightening all nuts, bolts, screws, oiling blower motor, checking of all electrical connection, checking for leakage etc and re-fixing the AC in existing place properly all as specified and directed.
Repair, maintenance and servicing of solar type street light including mantenance of batteries and filling distilled water all as specified and directed.
Repair, maintenance and servicing of Smoke detector machine during contract period including fire alarm control panel complete with display board of 160 character, display with touche keypad, mother board with CORTEX 32 processor, inbuilt RS -485 networking circuit for peer to peer networking,inbuilt USB 2.0 port for upload and download the configeretation tools, two Nos, inbuilt programmable relays, 04 Loop card circuit, power supply board with fully protected SMPS operation from 120 to 220V AC ± 10%, 50/60Hz, Battery Back up 24V DC with inbuilt charger, panel of IP-50 rating, operational : MODBUS converter for BMS integration, graphical software, software for TCP/IP Module, Provision for autodialer, loop card with capacity of 254 devices of both detector and modules in any combination, SLC supports both both Class A and Class B wiring complete all as specified and as directed.(Without spare parts).
M&L for repair/replacement addressable multi sensor heat cum smoke detectors with base and binary coded address setting, dual LED's for 360 degree visibility, sleek low profile housing design, regular 100mm base, IP -42 rating all as specified and as directed.
M& L for taking down, repair and re-fixing properly above item no 1.04
M&L for fepair/replacement addressable manual call point resettable type, with back box with binary coded address setting and status LED for 360 degree visibility of IP-50 rating complete all as specified and as directed.
M& L for taking down, repair and re-fixing properly above item no 1.06
M&L for fire alarm conventional horn, wall mounted type, rated at 90dB @ 1Minute for audiable annucition complete all as specified and as directed.
M&L for for addresssable fault isolater module capable of mounting shorted loop circuit and automatically restore communications when shorted conditions are corrected complete all as specified and directed.
Supply and fixing as in repair for gun metal globe or gate valve class-1 (pressure rating) conforming to IS-778 with iron wheel head screwed both ends for GI tubing complete all as specified for 20/25 mm bore of tubingas per requirement complete all as specified and directed.
Supply and fixing as in repair for gun metal globe or gate valve class-1 (pressure rating) conforming to IS-778 with iron wheel head screwed both ends for GI tubing complete all as specified for 50mm bore of tubing complete all as specified and directed.
M/L GI Tubing 50 mm bore medium grade of following size laid in trenches/fixed on wall, floor, ground including all accessories complete all as specified and directed.
M/L GI Tubing 20 mm bore medium grade of following size laid in trenches/fixed on wall, floor, ground including all accessories complete all as specified and directed.
Supply and fixing PVC water storage tank of capacity 2000 ltr, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as specified and directed
Supply and fixing stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 15 mm dia complete allc as specified and directed.
Disconnecting the defective/worn out hermetically sealed unit (compressor) from the system and S&F in replacement of the defective compressor by new one with suitable capacity /model and re-connecting the compressor to the system properly for window type AC 1.5 Ton capacity and testing complete all as specified and directed.
M&L for Gas mafron 22/Freon 22 charging in the system including replacement of capillary tube and strainer for proper cooling of AC 1.5 Ton capacity complete all as specified and directed.
Disconnecting and repair replacement the blower motor from the system , reconnecting the blower motor of the system properly, making electrical connection for proper functioning of AC 1.5 Ton capacity complete all as specified and directed.
Supply and fixing suitable starting capacitor for different make of air conditioners of 1.5 Ton capacityas required at site after taking out old worn out starting capacitor complete all as specified and as directed.
All as per Item No 1.19 above but running capacitor
Supply and fixing suitable cooling coil assembly for different make of air conditioners of 1.5 Ton capacityas required at site after taking out old cooling coil assembly complete all as specified and as directed.
Taking out existing AC (Window type) carefully by disconnecting existing electrical connection, removing aside, packing and cleaning with blower and soap solution making dust free to the system, tightening all nuts, bolts screws, oiling blower motor, checking of all electrical connection, checking for leakage etc and re-fixing the AC in existing place properly other 1.5 Ton capacity complete all as specified and directed.
Material & labour for single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 250 volts, 20 Amps, 10 kA including taking down the old one complete all as specifiedand as directed.
Taking out existing AC (Split type unit) carefully by disconnecting existing electrical connection, removing aside, packing and cleaning with blower & soap solution making dust free to the system, tightening all nuts, bolts, screws, oiling blower motor, checking of all electrical connection, checking for leakage etc and re-fixing the AC in existing place properly of the following capacity all as specified and directed of Size 1Ton/1.5 Ton Capacity :
All as per Item No 1.24 but capacity of 2 Ton
Vacuum leak testing, flushing and gas charging including supply of Gas for AC with Mafron -22 / Freon-22 refrigerant and testing complete all as specified and directed of size 1 Ton /1.5 Ton Capacity
All as per Item No 1.26 but capacity of 2 Ton
S&F blower motor fan of suitable type/model of reputed firm/company of capacity 2 ton
All as per Item No 1.28 but capacity of 1.5 Ton
Replacement of remote control electronic circuit board of AC of capacity 1.5 Ton all as specified.
M & L for Taking down unserviceable condensing coil suitable for AC 2 Ton capacity and replacing by new one as Specified and directed,
Taking down unserviceable starting capacitor suitable for AC 1.5 or 2.0 Ton capacity and replacing by new one complete all as specified and as directed.
All as per Item No 1.32 above but running capacitor
M & L for Taking down unserviceable condensing coil suitable for AC 1.5 Ton capacity and replacing by new one as Specified and directed,
M&L forTaking down carefully unserviceable compressor unit from base by dismantling all electrical/gas connection and replacing by new sealed compressor unit complete excluding vacuuming and gas charging and connecting all electrical and gas pipe connection and testing complete all as directed for the AC 2 Ton capacity.
All as per Item No 1.35 above but of capcity 1.5 TR
S&F copper tube for connection from outdoor unit to indoor unit for sifting of split type AC catered in Schedule ‘A’ here-in-before, complete all as specified and directed for dia :- ½” dia
All as per Item No 1.37 but dia 3/8” dia
M&L disconnecting the unserviceable hermatically sealed compressor from base by Dismantling all electrical/gas connection complete from the system repairing, rewinding and overhauling the defective compressor parts and reconnecting the compressor to the system properly. including vacumming gas M-22/F-22 refrigerant connecting all as directed/specified by Engr-in-charge.
Material and labour for gas mafron 22/freon 22/134a charging in the system including replacement of capillary tube and strainer for proper cooling .
Supply and fixing suitable starting capacitor for water coolers after taking out old worn out starting capacitor complete all as specified and as directed.
All as per Item No 1.41 above but running capacitor
Supply and fixing of blower motor of required size after taking out old blower motor complete all as specified and as directed.
Servicing/cleaning with blower & soap water solution making dust free to the system tightening all nuts, bolts, screw etc, oiling to blower motor and re-fixing the water cooler in existing places properly to make sure that there is not extra unwanted sound and vibration created from water cooler complete all as specified and directed.
Taking down exhust fan any sweep with disconnecting the electric connection complete all as specified and directed.
Dismantiling the winding of Exhaust fan of 450mm Sweep for rewinding with suitable size of super enamelled copper wire including necessary heat varnishing over hauling complete reassembling and testing all as specified and as directed.
All as per item No 1.46 above but 300 mm Sweep
Fixing only exhaust fan and connecting up including provision of of cable from ceiling rose or connector to fan.
Dismantiling the winding of Pedestal fan of 450mm Sweep for rewinding with suitable size of super enamelled copper wire including necessary heat varnishing over hauling with replacement of ball bearing complete reassembling, testing and refixing all as specified and as directed.
Dismantiling the winding of Pedestal fan of 600mm Sweep for rewinding with suitable size of super enamelled copper wire including necessary heat varnishing over hauling with replacement of ball bearing complete reassembling,testing and refixing all as specified and as directed.
Taking down fan, sealing cable end, dismantiling fan blades and removing fan and blades to store complete all as specified and directed.NOTE : Spares for replacement will be measured and paid separately under appropriate items.
Dismantiling the winding of ceiling fan of 1200 mm sweep for rewinding with suitable size of super enamelled copper wire including necessary heat varnishing over hauling complete reassembling and testing all as specified and as directed.
Supply only ball bearing 6201/6202 suitable for 1200mm sweep celing fan complete all as specified and as directed.
Supply only Rubber Bush suitable for 1200 mm Sweep celing fan complete all as specified and as directed.
Supply only Condensor 2.15 Mfd for 1200 mm Sweep celing fan complete all as specified and as directed.
Supply only Canopy 1200 mm Sweep celing fan complete all as specified and as directed.
Supply only Condensor Stand 1200 mm Sweep celing fan complete all as specified and as directed.
Supply GI nuts bolt and washer 1200 mm Sweep celing fan complete all as specified and as directed.
Material & labour for painting of ceiling fans any sweep complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dusts etc including writing of MES No complete all as specified.
Hangining only ceiling fan and connecting up including provision of of cable from ceiling rose or connector to fan
Material & Labour for replacement of fan regulator resistance type 230 Volt suitable for any type of ceiling fan sweep with modular afn regulator including taking down the old one complete all as specified and directed.
Taking down carefully aluminium / copper point wiring with surface / concealed PVC conduit or wooden batten (light, fan, socket, bell, or power) including sunk in cast iron / pressed steel terminal boxes except fitting such as switches. Ceiling roses, lamp holders, sockets, regulators, call bell, light fitting any sketch etc and making good disturbed surfaces of walls , floors etc complete.
Taking down carefully aluminium sub main wiring on wooden batten / PVC surface conduit/Casing Capping complete of any size.
Taking down main switches and distribution board of any size complete.
M & L for point wiring with FRLS, PVC insulated, unsheathed, 1100 volts grade, single core, multistranded, copper conductor 1.5 Sq mm cable drawn through and including surface PVC casing caping medium grade not less than( ISI marked) with all fitting and fixing accessories including sunk in cast iron / pressed steel terminal boxes (duly painted two coats of anticorrosive paint out side and two coats aluminium paint inside) with 3 mm thick hylum laminated bakelite sheet cover for mounting switches, sockets, fan regulators etc including provisioning of FRLS, PVC insulated, unsheathed 1100 volts grade, single core, multi stranded copper conductor cable of size 1.0 Sq mm as continuous earth wire and connecting to common earth dolly complete for One light / bell / fan point controlled by one switch. :-
All as per Item No 1.65 but one socket outlet 5 Amps controlled by one switch on same board.
All as per item No 1.65 but one socket outlet 5 Amps controlled by one switch on independent board.
All as per item No. 1.65 above but with 2.5 sq mm multi stranded copper conductor cable for one 15 Amps socket outlet controlled by one switch on independent board and 1.5 Sq mm multistranded copper conductor cable as continuous earth wire complete.
M & L for Switch piano flush type pole one way 6 Amps, 250 V, ISI Marked complete all as specified and as directed.
M & L for Switch socket combination 2 / 3 pin 5 Amps, multipurpose, 240 V flush type, controlled by one switch 6 Amps complete all as specified.
M & L for Switch socket combination, multipurpose, flush type, 5 Amps / 16Amps, flush type controlled by one switch 16 Amps, 240 volts, ISI Marked complete all as specified and as directed.
M & L for PVC / polycarbonated isolated body, ceiling rose, surface, 3 terminals, 65 x 20 mm size complete all as specified and as directed.
Material & Labour for Sheet metal enclosure MCB DB Triple pole and neutral, 4 way, 415 volts with 200 Amps rated bus bar double door type complete all as specified.
Material & Labour for Sheet metal enclosure MCB DB SPN, 2 way, 415 volts with 200 Amps rated bus bar type complete all as specified.
Material & Labour for Sheet metal enclosure MCB DB SPN, 4 way, 415 volts with 200 Amps rated bus bar double door type complete all as specified.
Material & Labour for Sheet metal enclosure MCB DB SPN, 8way, 415 volts with 200 Amps rated bus bar double door type complete all as specified.
Material & Labour for Sheet metal enclosure MCB DB SPN, 12 way, 415 volts with 200 Amps rated bus bar double door type complete all as specified.
Material & labour for MCB Single pole, 240 volts, 10 kA, 'C' curve of capacity 6 to 32 A.
M&L for MCB Single pole, 240 volts, 10 kA, 'C' curve of capacity 40 to 63 A.
Material & labour for MCB SPN, 240 volts, 10 kA, 'C' curve of capacity 6 to 32 Amps.
Material & labour for MCB SPN, 240 volts, 10 kA, 'C' curve of capacity 40 to 63 Amps.
Material & labour for MCB, 4 pole, TPN, 415 volts, 10 kA, '`C`' curve 6 to 32 Amps capacity all as specified and as directed.
Material & labour for MCB, 4 pole, TPN, 415 volts, 10 kA, '`C`' curve 40 to 63 Amps capacity all as specified and as directed.
Material & labour for MCCB, 4 pole, TPN, 415 volts, 16kA, 100 Amps capacity adjustable type housed in factory made sheet steel enclosure including connecting to existing panel board and connecting up complete all as specified and as directed.
Material & labour for MCCB, 4 pole, TPN, 415 volts, 36kA, 200 Amps capacity adjustable type housed in factory made sheet steel enclosure including connecting to existing panel board and connecting up complete all as specified and as directed.
Material & labour for MCCB, 4 pole, TPN, 415 volts, 36kA, 350 Amps capacity adjustable type housed in factory made sheet steel enclosure including connecting to existing panel board and connecting up complete all as specified and as directed.
Suply only retrofit 2 ft LED PL Lamp 18 W.
S&F in repair industrial LED batten suitable for 1x20 W retrofit T8 LED tube light rod 1200mm including all accessories all as specified and as directed. Crompton Cat No - DMLN1LT8-16 or equivalent as in the list of makes.
Ditto above itm No 1.88 but batten suitable for 2x20 W. Make Havells Cat No - LHFYBYG2IB1W036 or equivalent as in the list of makes.
S&F Linear LED T8 tubular lamp of 20 W with extruded aluminium body PC diffuser and inbuilt driver complete all as specified and directed.
Material and labour for integrated LED Batten type 1X20W, 230V tube light fitting energy efficient surface and wall mounted led batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. Make - Crompton LDL-36-CDL or equivalent as in the list of makes
All as per above but of suspended linear type/hanging type. Make - Crompton LCPL54-36-CDL or equivalent as in the list of makes
Material & labour wiring for circuit / submain wiring along with earth wire with the cable FR LSH, PVC insulated, un sheathed, copper conductor, multistranded, 1100 volts grade single core cables drawn through and including non metalic PVC casing & Capping and accessories surface / concealed in walls all as specified of the sizes.4 x 6.0 Sq mm + 2 x 4.0 Sq mm complete all as specified andas directed.
All as per item No 1.93 above but size 2x 6Sqmm + 1 x 4Sqmm
All as per item No 1.93 above but size 2x 4Sqmm + 1 x 2.50 Sqmm
S&F in repair for 2x2 recessed mounted LED fitting 42W for replacement of Unserviceable recessed mounted CFL Fitting 4x36W polycarbonate housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. Make: Havells cat part No VENUSNEOTW2X2PLR42WLEDTWA or equivalent as in the list of makes
Material and labour for LED street light for replacement of Unserviceable HPSV/LPMV Bldg securuty lights with 45W +/- 5 % Top Maintainable LED Bldg security light/Street Light luminaire with System efficiency of 115 lm/W. LED Street Light shall be made up of Die Cast aluminium housing suitable to mounted on 40 mm OD bracket arm. Make - Havells Cat No ENDURACITYLINERNEXGENSL45 WLED757SASYBOPC or equivalent as in the list of makes
Material & Labour for earthing with copper earth plate of size 60×60cm ×3.15mm thick electrode thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using 4mm dia galvanised wire as earthing lead as shown in electrical plate No. 5 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:2:6 type C-1 using 20 mm graded stone aggregate, pit, funnel, 20 mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8 mm dia TMT bar @150 c/c both ways, one lifting handle made out of 10 mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick incl testing on completion, complete all as specified and directed.
Deduct the total amount of Credit against Sch A, B/F from Ser Page No =(-) Rs 28475.00 Note: The amount is fixed and shall be deducted from total amount of BOQ quoted by the bidder to arrive at Contract Agreement amount.
M/s. Bijoy Engineering Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .