quantum of electrical shocks with facility for monitoring vital parameters.
Operational Requirements
1. Defibrillator should be Bi- Phasic, light weight and latest model
2. Should monitor vital parameters and display them
3. Should print the ECG on thermal recorders.
4. Should work on Manual and Automated external defibrillation (AED) mode.
6. Should be capable of doing synchronized &a synchronizedcardio version
BIDDER MUST HAVE TO SUBMITTED PART-III TECH BID PHYSICALLY IN TENDER ALONG
WITH SIGN AND STAMPED. FAILING IN WHICH, WILL BE STRAIGHTWAY REJECTED.
7. Can be operated from mains as well as battery
8. Should have defibrillator testing facility
Technical Specifications
Should be a Low Energy Biphasic defibrillator monitor with Recorder, having
1. capability to arrest all arrhythmia within a maximum energy of 360 Joules
Energy settings: Should be capable of delivering energy in increments of 1-2
2. joules up to 30J and increments of maximum 50J thereafter.
3. Charge control: Automatic if shock is recommended based on heart rhythm
Should have range of 1-360 joules with charging time of less than 5 seconds
4. for maximum energy.
5. Should have device status indicator for readiness of use
6. Should have facility of manual defibrillation upgradable to external pacing
Should have at least 6 inch high resolution colour monitor for ECG(3 to
7. Leads) with three waveform capability; upgradable to SpO2, NIBP & etCO2
Should monitor ECG through paddles, pads and monitoring electrodes and
8. Defibrillate through pads and paddles.
Should have Automatic Lead switching to see patient ECG through paddles
9. or leads
Should measure and compensate for chest impedance for a range of 25 to
11. Should have a built in 50mm strip printer/ thermal recorder and 3 channel
BIDDER MUST HAVE TO SUBMITTED PART-III TECH BID PHYSICALLY IN TENDER ALONG
WITH SIGN AND STAMPED. FAILING IN WHICH, WILL BE STRAIGHTWAY REJECTED.
ECG recorder
Should have external & internal paddles with paddles contact indicator – for
12. good paddle contact.
13. Single Adult and pediatric paddles should be available.
Should have event summary facility for recording and printing at least
14. events and 50 waveforms.
Should be capable of printing Reports on Event summary, configuration, self-
15. test, battery capacity etc
16. Should have facility for self-test/check before usage and set up function
17. Should have user-friendly color-coded operation
Environmental factors
The unit shall be capable of being stored continuously in ambient
1. temperature of 0 -500C and relative humidity of 15-90%
Shall meet IEC-60601-1-2: 2001(Or Equivalent BIS) General Requirements of
2. Safety for Electromagnetic Compatibility.
Power Supply
Power input to be 120-240VAC, 50/60Hz. Power cable should be fitted with
1. Indian plug and adapter.
2. Resettable over current breaker shall be fitted for protection
Should have a Rechargeable Battery capable of usage for at least 90minutes
OR30 Discharges of 270 joutes with 3 hours of monitoring OR at least
BIDDER MUST HAVE TO SUBMITTED PART-III TECH BID PHYSICALLY IN TENDER ALONG
WITH SIGN AND STAMPED. FAILING IN WHICH, WILL BE STRAIGHTWAY REJECTED.
shockes of 200 joules without monitoring.
Standards, Safety and Training
1. Should be FDA approved product
2. Manufacturer should have ISO certification for quality standards
Electrical safety conforms to standards for electrical safety IEC-60601-1
GeneralRequirements and IEC60601-2-25Safety of Electrocardiograms. (OR
3. EQUIVALENT BIS Standard)Drop Test-Withstands 1 meter drop to any edge,
corner or surface.
Should conform to international test protocols on exposure to shock forces
4. and to vibration forces.
Should meet IEC 529 Level-2 (IP2X) for enclosure protection solid foreign
5. object ingress.
Should meet IEC 529 Level 3 (IP3X)(spraying water) for enclosure protection,
6. water ingress.
Should have local service facility. The service provider should have the
necessary equipments recommended by the manufacturer to carry out
7. preventive maintenance test as per guidelines provided in the
service/maintenance manual.
Documentation
1. User Manual in English
2. Service manual in English
BIDDER MUST HAVE TO SUBMITTED PART-III TECH BID PHYSICALLY IN TENDER ALONG
WITH SIGN AND STAMPED. FAILING IN WHICH, WILL BE STRAIGHTWAY REJECTED.
List of important spare parts and accessories included in the warranty with
3. their part number and costing
List of important spare parts and accessories not included in the warranty
4. with their part number and costing
5. Certificate of calibration and inspection from factory
Warranty and After Sales Service:
All spare parts and consumables should be available with supplier or
1. principal
Should have local service facility .The service provider should have the
2. necessary
Equipments recommended by the manufacturer to carry out preventive
3. maintenance test as per guidelines provided in the service/maintenance
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
TECHNICAL BID-LN03.pdf
TENDER CONDITION LN-003.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].