Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.4 CrAccepted-AOC 309 10 SURESHWAR TECHNO IT PARK PREMISES CO OP SOC LTD NEW LINK ROAD BORIVALI WEST MUMBAI 400092 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400092 | ₹50.4 Cr Quoted ₹50.3 Cr | L1 | Accepted-AOC Qualified L1 AOC |
| 2 | L2₹51.7 CrRejected-Finance THIRD FLOOR AMIT CRYSTAL SENAPATI BAPAT ROAD PUNE 411 016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹51.7 Cr | L2 | Rejected-Finance Not L1 Hence Reject Tender |
Tender Value
₹48.0 Cr
EMD Value
₹24 L
Closing Date
30 Jan 2023, 6:00 pmClosed
Executive Engineer, Public Works Division, Pune 1.
Executive Engineer, Public Works Division, Pune 1.
72-1 Construction of EVM and VVPAT Storage Godown at Ravet, Dist. Pune - (Including Electrical Work).
2023_PWDRP_865710_1
E-Tender Notice No. 72 for 2022-2023
Open Tender
Civil Works - Buildings
547 days
Ravet Pune
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
₹24 L
Chief Engineer, Public Works Region, Pune 1.
29 Mar 2023
10 Jan 2023
1 Feb 2023
10 Jan 2023
30 Jan 2023
10 Jan 2023
17 Jan 2023
Amount
CIVIL WORK Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 millimetre , removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 millimetre in thickness.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming , watering including shoring and strutting etc. complete. (including all leads & lifts) By Mechanical Means
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming , watering including shoring and strutting etc. complete. (including all leads & lifts) By Mechanical Means
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming , watering including shoring and strutting etc. complete (including all leads & lifts) By Mechanical Means
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including tri millimetre ing and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (including all leads & lifts). By Mechanical Means
Providing and laying Cast in situ/Ready Mix cement concrete in Mix-10 of trap metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade)
Providing and laying Cast in situ/Ready Mix cement concrete Mix-25 of trap metal for Reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced cement concrete columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade)
Filling in plinth and floors with approved excavated material in 15 centimetre to 20 centimetre Layers including watering and compacting etc. complete.
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete.Only labour rate considered
Providing and laying Cast in situ/Ready Mix cement concrete Mix-25 of trap metal for Reinforced cement concrete columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Ground floor
First Floor
Second floor
Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in Mix-25 of trap metal for Reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying /pumping, compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Ground floor
First Floor
Second floor
Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete Mix-25 of trap metal for Reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Ground floor
First Floor
Second floor
Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap metal for Reinforced cement concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Ground floor
First Floor
Second floor
Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in Mix-25 of trap metal for Reinforced cement concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Ground floor
First Floor
Second floor
Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in Mix-30 of trap metal for Exposed concrete pardi of required thickness including aluminium centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) Ground floor
First Floor
Second floor
Third Floor
Providing and casting in situ / ready mix Plain cement concrete Mix -20 grade of trap metal for coping to head walls / parapet including centering, form work, compaction and curing etc. complete. with Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) enabled Concrete Batch Mix Plant (Pan Mixer) with fine agreegates of required specifications (Natural sand / Vertical shaft impact (VSI) sand finely washed etc) Ground floor
First Floor
Second floor
Third Floor
Providing and fixing during laying in Reinforced cement concrete Slab rectangular 2 millimetre thick mild steel sheet fan hook box of size 180 millimetre x100 millimetre with required depth with holes or notches as required, bottom and top sides of 1.6 millimetre mild steel sheet fixed with 3.5 millimetre dia. round headed screws together with 12 millimetre diameter mild steel bar bent to shape with hooked ends for fan hook and painting to exposed surface. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing in position Thermo Mechanically Treated (TMT) FE-500 bar reinforcement of various diameters for Reinforced cement concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted / welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Ground floor
Third Floor
Supply and Installation of Dpi Flux translucent roof with standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 18 millimetre thick of 1200 millimetre (min.) width with angular daylighting concept. Panels shall have minimum seven layers in a truss bridge design for higher flexibility & strength. Panels with opaque and translucent clear combination as per required lux level and design requirements with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall have an additional IR Blocking features for enhance thermal comfort. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with a continuous aluminium I Beam holding the base of the standing seam along the length of the panel & fixed with purlin with self-drilling hex head screws offering best stability with a pull-out load of min. 21000N (21KN) tested as per ISO 6892:1998 and IS 1608: 2005., as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.9 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineer in charge. Colour: As per approval. The 18 millimetre thick panels shall be used for a roofing height of upto 25 metres. Third Floor
Providing and fixing turbo ventilator of 24" diameter including cutting skylight, pasting with non shrinkable sealant at joint of skylight etc. complete as directed by Engineer-In-Charge. Third Floor
Providing Autoclaved Aerated Concrete Block masonary of conforming to Indian Standard : 2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Ground floor
First Floor
Second floor
Third Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing internal cement plaster 12 millimetre thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. Ground floor
First Floor
Second floor
Third Floor
Providing and applying plaster with plaster of paris in 6 millimetre thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1kilogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Ground floor
First Floor
Second floor
Third Floor
Providing internal cement plaster 20 millimetre thick in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete. Ground floor
Third Floor
Providing and applying laying Aggregate plaster in granite / marble stones, as decorative finish to give granite / marble like appearance to concrete, brick or block surfaces in all position including preparation of surface smoothly, evenly by racking of joints in case of Brick or block work including backing layer of 12 millimetre thick with cement mortar 1:3 with 2% integral cement water proofing compound, roughening for wall keying hardening and drying the surface for a minimum five days gaps including second coat of cement lime mortar into a proportion 1:4 preparing the surface for three coat of marble finish plaster giving a thin coat of white cement and two parts of course calcite powder, applying the mortar with steel float on the surface in proper evenness applying at coat of white cement and lime to set a smooth finish then applying a thin coat of slurry made of white cement and black oxide colour in required proportion by the steel float to get black streaks on the surface and curing the surface for two days including all materials and labour etc. complete. Ground Floor
First Floor
Second floor
Third Floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. Ground floor
First Floor
Second floor
Third Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kilogramme /15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Reco millimetre ended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Ground floor
First Floor
Second floor
Third Floor
Providing water proof bedding for flooring of Bath and Water Closet 25 millimetre thick in cement mortar 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12 millimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1 kilogramme per bag of cement laying brick bat coba of required thickness in cement mortar 1:5 with waterproofing compound 1 kilogramme per bag of cement grouting and finishing the top layer with 20 millimetre thick brick bedding in cement mortor 1:3 with waterproofing compound 1 kilogramme per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. Ground floor
First Floor
Second floor
Third Floor
Smart Care Preapply HDPE 80 for Raft and Uncofined Retaining Walls 1- Supplying and Installing of Asian Paints Smarteare 1.50 millimetre thick pro applied HDPE fully bonded membrane or equivalent make having puncture resistance of HOON as per ASIMI 154), tensile strength of 21 Mpa, and hydrostatic head resistance not less than zom water head as per ASTM D 545 elongation of 500% as per ASTM D412, peel adhesion to concrete of 1200 N/m as per ASTM D 901, Lap peel adhesion 450N/m as per ASTM D1876. The size of the membrane should be 1.2 metre x 20 metre. The pre-applied, fully bonded HDPE sheet membrane shall be loosely laid on PCC and gets bonded to the underneath of the poured concrete of base/ raft slab and confined retaining wall. The fully bonded HDPE sheet membrane shall consist of a high performance PE film, self adhesive polymer layer and unique particulate layer with pressure sensitive adhesive, which bonds fully to the poured concrete of base slab/confined retaining wall. The membrane shall have minimum of 75 millimetre side laps and end laps which shall be sealed with double sided adhesive tape, plc complete as per manufactures specification and Instructions. This shall include cleaning & removal of all the dust, dirt, oll, grease, coment laltance, loose particle & prepare the P.C.C. Substrate for laying of waterproofing system, as directed by Engineer Incharge and covering 10 years Guarantee against leakages on Court fee stamp paper of Rs. 500/- etc. complete. Third Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar 1:3 admixed with approved water proofing compound and finally top finishing with average 20 millimetre . thick layers of same mortar added with jute fiber at 1kilogramme per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 millimetre x 300 millimetre . making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Ground floor
Third Floor
Providing and applying required coats of a water based Evercrete Deep Penetrating Sealer (DPS) on cement concrete surface like roads, beams, and columns, plastered walls, basements, roofs, potable water tanks etc to react with cement and to penetrate concrete structure thereby making it resistant to chemicals / chlorides water to make it dust proof and to act as a water resistant at the same time which Strengthens the treated surface and reduce the curing period etc complete. - Note -- for item One Number 7 to 4 prior approval of Superintending Engineer will be necessary Third Floor
Providing fine cement finish 1.5 millimetre thick over green plaster surface including scaffolding curing etc. complete. Ground floor
Third Floor
Providing and laying Polished Kota stone flooring With Hand-Cut Polished Kota Stones 25 millimetre to 30 millimetre thick and required width in plain/diamond pattern on bed of 1:6 Cement mortar including cement float, filling joints with neat cement slurry, curing, cleaning and Mirror Polishing etc. complete Note- Water absorption for kota stone should not exceed 0.05%.( Item to be used with prior permission of Superintending Engineer ) Ground floor
First Floor
Second floor
Third Floor
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 millimetre to 30 millimetre thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. Ground floor
First Floor
Second floor
Third Floor
Providing and laying vitrified rustic matt stone finish tiles having size 590 millimetre to 605 millimetre x 590 millimetre to 605 millimetre of 8 to 10 millimetre thickness and confirming to Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and laying vitrified rustic matt stone finish tiles having size 590 millimetre to 605 millimetre x 590 millimetre to 605 millimetre to 8 to 10 millimetre thickness and confirming to Indian Standard. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and laying vitrified matt fininsh tiles having size 590 millimetre to 605 millimetre x 605 millimetre of 8 to 10 millimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and laying vitrified matt finish tiles having size 590 millimetre to 605 millimetre x 605 millimetre of 8 to 10 millimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 millimetre to 20 millimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing incement mortar 1:3 curing and cleaning etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and laying in situ cement concrete Mix -30 with tremix treatment for 200 millimetre thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 millimetre wide and 20 millimetre deep with necessary refilling with bitumen ( excluding reinforcement) with coarse and fine aggregate (natural sand/ Vertical shaft impact (VSI) grade finely washed crushed sand) etc. complete. Ground floor
First Floor
Second floor
Third Floor
Fire Door 45 millimetre 1HR FRL (60/60) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2.Providing 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). with prior approval of concerned Superitending Engineer.a) Door Frame: Supplying frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 kilogramme per cubic metre) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 60 millimetre spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10 millimetre x 4 millimetre affixed in the slit of the Frame for fire and smoke sealing, etc. complete. - Ground floor
First Floor
Second floor
Third Floor
Fire Door 45 millimetre 1HR FRL (60/60) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2.Providing 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). with prior approval of concerned Superitending Engineer.b)Shutter : Providing of 65 millimetre thick asbestos free composite - 3 criteria - fire, heat and smoke check Accoustic Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9 millimetre Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x32 millimetre with 32 millimetre thick infill of ceramic fiber (density 128kilogramme s/CMT), vermaculite mix faced with 6 millimetre Fire retardant High Density ply, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of In tumescent paint of minimum 200 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10 millimetre x4 millimetre concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping. Ground floor
First Floor
Second floor
Third Floor
Fire Door 45 millimetre 1HR FRL (60/60) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2.Providing 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). with prior approval of concerned Superitending Engineer.c) Vision Panel:1 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside the shutter structure with 10 millimetre inside the shutter on all sides with U- glazing. An additional insulated powdercoated 'Z' channel of 16 swg MS sheet to be fixed for reinforcement of the joints. With clear fire resistant glass panes 11 millimetre thick having minimum 120 minutes fire Description Ground floor
First Floor
Second floor
Third Floor
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 millimetre x 40 millimetre x 5 millimetre with oil painting, etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing Strong Room Door of specified size of GODREJ Make with Grill Gate, Godrj Air Ventilator (HevyDuty), Godrej Air Exhust Fan and Godrej V-Cage (FanCover) incuding conveying, loading, unloading etc. complete as directed by Engineer-In-Charge. Ground floor
First Floor
Second floor
Third Floor
Supply and installation of Suniti make 2.0 metre x 2.4 metre size metal doors with fire rating of 120 mins. Frame 100 millimetre x 50 millimetre x1.5 millimetre Galvanised Iron sheet with back plate provision of 3 millimetre pre drilled for hinges and fasteners. Shutter 46 millimetre thick made from 2nos of 1 millimetre thick GI sheet with infill of Rockwool or Honeycomb craft paper. Hardware used shall be Geze/Yale/Coburn. The entire system shall be powder coated with Pure polyester Matt finish exterior grade UV resistant powder coating of nominal 45-50 microns dft etc. complete as directed by Engineer-In-Charge Ground floor
First Floor
Second floor
Third Floor
Solid Core Flush door Single leaf Providing and fixing factory made solid core flush door in single leaf 35 millimetre thick, decorative types, of exterior grade, as per detailed drawings, conforming to Indian Standard .:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame). Commercial Hard Wood shutter. Ground floor
First Floor
Second floor
Third Floor
Solid Core Flush door Double leaf Providing and fixing factory made solid core flush door shutters in double leaves 35 millimetre thick,decorative type of exterior grade, as per detailed drawings, conforming to Indian Standard. : 2202– 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame) Commercial Hard Wood shutter. Ground floor
First Floor
Second floor
Third Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetre thick for door frame/ dado/ window boxing etc. On cement mortar 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing 30 millimetre thick Poly vinyl chloride FLUSH L DOOR SHUTTER consisting of panel of hollow Poly vinyl chloride profile of 20 millimetre thickness consisting frame made out of mild steel tubes of 19 gauge thickness and size of 19 millimetre x 19 millimetre inserted inside the hollow section of stiles rails top ?and bottom rails and two 19x 19 millimetre Mild Steel tubes inserted horizontally inside the hollow profile section using 4/5 millimetre sheet using screws hollow profile shall be lipped with 10 millimetre (5 millimetre x 2 millimetre ) thick x 20 millimetre width on stiles and rails using solvent cement. The inner panel shall be laminated with 5 millimetre thick termite proof waterproof plain /prelam Poly vinyl chloride sheet using solvent cement on the both sides of the panel including stainless steel fixtures and fastening etc. Complete as per direction of Engineer incharge, manufacturers specification and drawing. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 millimetre with lock plate of 3.15 millimetre thickness reinforced with 35 x 35 x 5 millimetre angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 millimetre and 3.15 millimetre respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 millimetre minimum size and shape with square bar, suspension shaft of minimum 32 millimetre diameter, hood cover of mild steel sheet not less than 0.9 millimetre thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (Indian Standard 62481979) (With mechanical gear) Ground floor
First Floor
Second floor
Third Floor
Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 millimetre minimum size, crossings of mild steel flats of size 18 x 5 millimetre T or E section for runner of minimum 40 x 6 millimetre size for flange, M.S. flat for top runner of minimum size 40 x 12 millimetre with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 millimetre max. spacing of vertical channels be 100 millimetre enclosed gate position and clear space of 150 millimetre between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (Indian Standard : 105211983). Ground floor
Providing & fixing of Casement fixed window of approved make with DGU. The extruded aluminium sections of Alloy 6063 tolerances confirming to DIN standard from approved raw material V2 / V4 as directed by Engineer in charge. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kilogramme per One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimetre x 1.22 millimetre box type, 5 millimetre thick sheet glass louvers, of approved quality etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15 millimetre Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20 millimetre , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 millimetre with 15 millimetre wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 millimetre and 600 millimetre Cross Tees with a web height of 32 millimetre and a load carrying capacity of 7.7 kilogramme s/M2 and minimum pull out strength of 100 kilogramme s.. The T Sections have a Galvanizing of 90 grams per square metre and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing in position Gypsum board false ceiling with 12.5 millimetre thick Gypsum boards, screwed/fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 millimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Ground floor
First Floor
Second floor
Third Floor
METAL FALSE CEILING WITHOUT SUSPENSION SUPPORT FROM TRUE CEILING: Providing & fixing horizontal level suspended metal ceilings comprising of Metalworks F-H 600 Hook-on corridor system manufactured by Armstrong Ceiling Solutions with Rectangular panels made of 0.7 millimetre thick Galvanised Steel (GI) of 120gsm, post coated to Global White colour, suitable for Interior applications and architectural finishes, double grid concealed system and butt joint panels. The panel width shall be 300 millimetre , length ranging from 1500 millimetre to 2660 millimetre . General Specifications:Entire system to be designed for Interior applications, and concealed Grid, Butt joint panels. Panel Specifications: Material: The F-H 600 rectangular Hook-on panels to be made of galvanized steel (GI) of minimum 120gsm hot dipped galvanization (both sides included) as per IS 277 (2003), zero or minimum spangled, in minimum base material thickness of 0.7 millimetre as per in IS:513 (1994). Dimensions: The panel Length varies between 1500 millimetre to 2660 millimetre , panel Width shall be 300 millimetre . The dimensional tolerances for length shall be ±1.0m up to 1000 millimetre L; ±1.5 millimetre between 1001 to 2000 millimetre L; ±2.0 millimetre between 2001 to 3000 millimetre L. The dimensional tolerances for width shall be±0.5m up to 300 millimetre W. Dimensional Tolerances for panel Thickness / panel width / panel length - to be measured in accordance with TAIM standards. Edge detail: the panels shall ha+A3ve Square Edge, with a 3 millimetre (W) x 8 millimetre (H) black foam gasket glued at the edges, typically on one long and one short side. All adjacent panels shall touch each other forming a butt joint and concealed grid visuals. Upturns: The short side of the panel shall have vertical upturns of minimum 30 millimetre (H) and shall be bent appropriately bent as per the manufacturer’s specifications for providing hook-on ends. The long side shall have inside horizontal bends of 5-15 millimetre for rigidity and vertical upturns of 40 millimetre (for length ranging from 1251-2660 millimetre ). Surface Finish: Plain: The panels shall be in plain unperforated finish (without any acoustical backing / felt). Colour and finishes: The panel surface shall be electrostatically powder coated (post coat) on visible side after mechanical production, using RoHS compliant powder, to achieve coating thickness ranging from 60-80µ and architectural quality finish. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM Ground floor
First Floor
Second floor
Third Floor
Providing and fixing 40 millimetre diameter and 1.5 millimetre thick Stainless steel hand railing in Stainless Steel 304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 millimetre diameter and vertical pipe of 38 millimetre dia at 0.60 metre centre to centre or as required and horizontal pipes of 25 millimetre dia in three rows, all pipes of 2 millimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimetre dia above newel post of 75 millimetre diameter etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper. Ground floor
Providing and laying in trenches 15 millimetre diameter Chlorinated Poly vinyl chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Ground floor
Providing and laying in trenches 20 millimetre diameter Chlorinated Poly vinyl chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Ground floor
Providing and laying in trenches 25 millimetre diameter Chlorinated Poly vinyl chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Ground floor
Providing and laying in trenches 32 millimetre diameter Chlorinated Poly vinyl chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Ground floor
Providing and laying in trenches 40 millimetre diameter Chlorinated Poly vinyl chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Ground floor
Providing and fixing on walls/ceiling/floor 20 millimetre diameter Chlorinated Poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing on walls/ ceiling/ floor 25 millimetre diameter Chlorinated Poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing on walls/ ceiling/ floor 32 millimetre diameter Chlorinated Poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing on walls /ceiling/ floor 40 millimetre diameter Chlorinated Poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and making ISI Mark ferrule connection of 32 millimetre diameter to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. Ground floor
First Floor
Second floor
Third Floor
Providing, laying and fixing poly vinyl chloride pipe of 110 millimetre . dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing poly vinyl chloride Rain water pipes of 110 millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to I.S. 13592-1992 including proper rainwater receiving recess with poly vinyl chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on cement concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the poly vinyl chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing, laying and fixing poly vinyl chloride pipe of 75 millimetre diameter with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing 15 millimetre diameter screw down bib/ stop tap of brass including necessary socket union nut complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing 15 millimetre diameter concussion push button type brass/gun metal self- closing tap including necessary socket complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing screw down 15 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing screw down for 25 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing 10 centimetre Poly vinyl chloride nahani trap with grating etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing 25 millimetre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber]. Ground floor
Providing and fixing 1st class Ivory glazed earthenware Orissa Type Water Closet Pan 580 millimetre diameter including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 millimetre thick, 10 liter poly vinyl chloride flushing cistern with all necessary pipe connection etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing Ivory european type wall-hung, of size 360 millimetre x 360 millimetre x 575 millimetre with flush valve of approved make including soil pipe, vent pipe upto outside face of wall, 100 millimetre diameter cast iron plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing Ivory glazed urinal of series with Pressmatic auto closing valve of having 32 millimetre diameter poly vinyl chloride flush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc.complete as directed by Engineer in charge. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing Table top Ivory wash basin of size 120x635x405 millimetre rubber plugs and brass chain, with pillar cock, Chromium plated Angular stop cock long thread, continental including stainless steel bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing chromium plated towel rod 16 millimetre diameter and 75 centimetre in length including all accessories complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing 450 millimetre x 550 millimetre size superior type Belgium mirror with 16 millimetre dia. nickel plated towel rod etc. complete. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing poly vinyl chloride Rain water pipes of 160 millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to I.S. 13592-1992 including proper rainwater receiving recess with poly vinyl chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on cement concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the poly vinyl chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Ground floor
Providing and fixing 15 centimetre x 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Ground floor
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round glazed stoneware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced cement concrete Cover medium duty 140 kilogramme with frame etc complete. Ground floor
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round glazed stoneware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced cement concrete Cover medium duty 140 kilogramme with frame etc complete. Ground floor
Providing and fixing 40 millimetre diameter Ball cock medium type with Poly vinyl chloride float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Third Floor
Providing and fixing machine cut mirror polished 18 millimetre to 20 millimetre thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish. Ground floor
First Floor
Second floor
Third Floor
Providing soak pit of size 120 centimetre x 120 centimetre x 120 centimetre including excavating and filling with brick-bats. Ground floor
First Floor
Second floor
Third Floor
Providing and fixing chromium plated sink cock with raised J" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete." Ground floor
First Floor
Second floor
Third Floor
Providing and fixing chromium plated BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Ground floor
First Floor
Second floor
Third Floor
Providing and laying concrete pipes of Indian Standard Non-pressure class of 300 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Ground floor
Providing and fixing reinforced cement concrete cover of size 60 centimetre x 45 centimetre with frame over inspection chamber etc. complete.Medium duty (100 kilogramme ) Ground floor
Third Floor
Providing and fixing 90 centimetre x 60 centimetre Granite plate engraving 10 centimetre height letter, figures including painting the lefters/figures with approved colour and shade complete. Ground floor
Providing and fixing 45 centimetre wide mild steel ladder of 40 millimetre x 6 millimetre mild steel flat stringers and steps of 18 millimetre diameter mild steel bar for water tank including fixing it in (1:2:4) Mix-15 cement concrete block 60 centimetre x 30 centimetre x 30 centimetre and painting the ladder complete. (Anti Corossive Paint) Ground floor
Third Floor
Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 centimetre and one number stainless steel 304 hinged rail 76 centimetre & three no Stainless 304 of (Grab Bar) 60 centimetre all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete as per the direction of Engineer-In-charge. Ground floor
First Floor
Second floor
Third Floor
RWH - Recharge Pit Providing and constructing recharge pit of 2.0 metre deep and 1.0 metre dia of pre-cast Reinforced cement concrete rings with 6.5" meter x 25 metre deep borewell at the floor of recharge pit including installation of combination of solid/perforated Poly vinyl chloride casing pipe wrapped around with netlon mesh including 300 millimetre thick sidefilling around outside of Reinforced cement concrete rings (annular space) with 40 millimetre size boulders including filling of recharge pit up to 0.5 metre depth with 25-75 millimetre clean washed gravels from bottom up followed by 0.5m depth of 10-25 millimetre of clean washed stones followed by 0.5 metre of washed river fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) media layer including covering with Reinforced cement concrete slab, manhole frame & cover, Poly vinyl chloride rungs, Poly vinyl chloride end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge. Ground floor
Conveyance of material/debris at a distance of 10 Kilometre as directed by the Engineer-In-Charge. Ground floor
Free Standing Table @ 1500Lx600Dx750HT Providing and fixing Table of Size 1500 x 600 x 750 millimetre . Top: made from 25 millimetre Prelaminated Particle board. All edges are covered by 2 millimetre . Thk. Poly vinyl chloride edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18 millimetre both side prelaminated particle boards.All edges are covered by 0.8 millimetre Poly vinyl chloride edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. millimetre . with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 millimetre prelaminated particle board,
Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery
Full Height Steel Storage @ 750Lx450Dx2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 millimetre thick & Top in 2 millimetre thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing.
Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25 millimetre to 450 millimetre section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete.
Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc.
Dismantling the Reinforced cement concrete Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete.
Providing and casting in situ / ready mix Plain Cement Concrete Mix-20 grade of trap metal for coping to head walls / parapet including centering, form work, compaction and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) with SCADA with fine agreegates of required specifications (Natural sand / Vertical shaft impact (VSI) sand finely washed etc)
Providing and erecting Y type barbed wire fencing with seven rows of wire with 2.45 millimetre diameter galvanised iron pipe ( Rezan/ concentiDeleted ire 0.75 millimetre diameter ) with hot dip and galvanised iron coated hooks as per drawing supported on mild steel angle 50 x 50 x 6 millimetre at 2.5 metre centre to centre including fixing and fastening with wire, painting mild steel angles with one coat of red lead primer and two coat of oil paint etc. complete.
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at optimum moisture content , carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ Vertical shaft impact (VSI) grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 millimetre , , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in- charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete.
Providing and laying in-situ Mix-40 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate ( natural sand/ Vertical shaft impact (VSI) grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6 metre X 0.6 metre centre to centre, admeasuring 80 millimetre at bottom and 40 millimetre at top with depth of 75 millimetre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.
Providing and casting in situ or precast tapering Reinforced cement concrete M-20 Barrier type Kerb without gutter ( as per IRC 86 1983) embedded 125 millimetre below ground level over M-10 PCC finished neatly with cement mortar 1:2, setting the same in cement mortar 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant
Providing and fixing in position Thermo Mechanically Treated (TMT) FE-500 , 25 millimetre diameter dowel bars precoated with anticorrosive epoxy paint of required Dia. 60 cms. Long and at 30.00 centimetre C/C and wherever directed including handling, straightening, necessary cutting supported by Thermo Mechanically Treated (TMT) FE-500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete.
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete.
Preparing Instant Lawn :- Excavating the ground to a required depth of 20 centimetre. Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil/silt & manure in 3:1 proportion to a height of 20 centimetre Mixing soil and Manure thoroughly well, leveling, with required slope, light watering, on previous night, rolling, on surface, Fixing readymade lawn turf, rolls, or slabs of required variety as directed. ramming on it for proper fixing & maintaining till well established by watering, weeding, clipping or mowing etc. complete.
Preparing flower Bed:- Excavating the ground to a required depth of 30 centimetre. Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soi & manure in excavated area in 3:1 proportion to a required height of 30 ems. Mixing garden soil and manure thoroughly, well, leveling, watering on previous night. Planting seedlings of required annuals 25 ems. apart Maintaining till well established by watering, weedings, Stirring replacing of casualties etc, Complete.
Planting large flowering/Shady trees :- (Minimum Height to 2 Mtr.)Digging pit with size 0.9 mete x 0.9 metre x 0.9 metre Removing & conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material up to a hight of 0.30 metre and remaining height of 0.60 metre with fresh garden soil & manure in in 3:1 proportion. Mixing soil and manure thoroughly well, leveling, as directed, watering previous night. Planting two or three year old,minimum 2.0 metre hight, healthy tree sapling as per specifications. Maintaining till well established by watering, weedings, Stirring of soil, staking, replacing of casualties etc. complete.
Providing and stacking of Foxtail palm of height 240-270 centimetre bottom girth 35- 40 centimetre well developed in big size HDPE bags as per direction of the officer-in-charge.
Providing and Laying factory made coloured chamfered edge Cement concrete grass paver blocks of required strength,thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 millimetre thick compacted bed of fine fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.), compacting and proper embedding/laying of inter locking paver blocks into the fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) and cutting of paver blocks as per required size and pattern, finishing and sweeping extra fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) and complete as per manufacturer spsecifications & direction of Engineer-in-Charge. 60 millimetre thick CC paver block of M-35 grade concrete with approved colour and design & pattern.
Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gram per square metre total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 millimetre Base Metal Thickness ( BMT ) (0.5 millimetre TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 millimetre effective cover width and nominal 25-30 millimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 millimetre center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kilogramme / One Square Metre)
Providing and fixing of colour coated Zincaluminium( R ) AZ150 ( min 150 gram per square metre total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 millimetre Base Metal Thickness ( BMT ) (0.5 millimetre TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated withAluminium-Zinc alloy (55% aluminiu millimetre 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyster paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 millimetre , comprising of nominal 25 millimetre exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 millimetre effective cover width and nominal 25-30 millimetre deep ribs with sublet square fluting in the five pan at nominal 180-250 millimetre center- to-center. The end rib shall be designed for anti-capacity groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 kilogramme / One Square Metre) 600 millimetre girth (Surface Width).
Providing and fixing in position aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 millimetre thick clear float glass etc. complete. b) Powder Coated
Providing and fixing White Glazed Earthenware full stall type Urinal with poly vinyl chloride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 millimetre diametre poly vinyl chloride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall
Providing and laying Cast in situ/Ready Mix cement concrete in Mix-20 of trap metal for Reinforced cement concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade)
Providing and fixing 20 to 25 millimetre thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 millimetre depth, filling the joints with 6 millimetre size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete )
Providing and fixing 20 to 25 millimetre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 millimetre between rough shahabad and Reinforced cement concrete walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 millimetre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete)
Providing and applying required coats of a water based Evercrete Deep Penetrating Sealer (DPS) on cement concrete surface like roads, beams, and columns, plastered walls, basements, roofs, potable water tanks etc to react with cement and to penetrate concrete structure thereby making it resistant to chemicals / chlorides water to make it dust proof and to act as a water resistant at the same time which Strengthens the treated surface and reduce the curing period etc complete. - Note -- for item One Number 7 to 4 prior approval of Superintending Engineer will be necessary
Providing and fixing reinforced cement concrete cover of size 90 centimetre x 45 centimetre with frame over inspection chamber etc. complete. Heavy duty (225 kilogramme )
ELECTRICAL WORK Estimate No. :115460-1 of 2022-2023 Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC
Supplying and laying HMS PVC conduit FRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW
Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG MA/BW
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type blanking plate one module duly erected on provided plate & box.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as per specification No WG-PW/CW
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires modular type switch earthing and required accessories as perspecification No WG-PW/CW
Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 770 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing polystyrene diffuser having system lumens output of Min. 1500 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens min. efficacy of 120 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 4 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades wire mesh duly erected complete.
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying, erecting, testing and commissioning of self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP WCR/WC22
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
Supplying, installing, testing and commissioning of 2kVA capacity online pure sine wave with backup time of 30 Min. PWM & IGBT based UPS with 0.8 to unity output pf single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/80Ah to 88Ah tubular battery with battery terminal wire duly charged with 36 months warranty complete.
Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting and marking FPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB.
Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 4 ways/phase (12 poles) with door 1.2mm thickness surface/flush mounted IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 4 ways /12 Poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 8 ways /24 poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting triple pole and neutral distribution board (TPNDB) SP/TP MCBs total 12 ways /36 poles with door 1.2mm thickness surface/flush mounted IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting triple pole and neutral distribution board (TPNDB) 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles) with door 1.2mm thickness surface/flush mounted on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Providing and erecting 4 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no. line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing and erecting 3 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withst and capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing and erecting 4 Pole MCCB 415V 200A rated short-circuit breaking capacity25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no.
Providing and erecting floor/wall mounting MCCB panel board with door suitable for four pole incoming 250A 4 ways four pole outgoing up to 100 A MCCBs on iron frame as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)
Supplying and erecting 525 V 3 phase 50 Hz. MPP type capacitor having minimum overcurrent capacity of 1.8 In peak inrush current capacity 300 In and minimum life 150000 hours kVAr bank of metalised polypropylene condensers (MPP) with the standard capacities of 2 3 5 7 10 12.5 and 15 kVAr units of P.F. correction for operation on 3 phase 50 Hz. with externally discharging resistances earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee.
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation) half round reinforced cement concrete pipe of IS 458 2003 NP-2 class of 150 mm internal diameter in proper line level and slope including providing and fixing collars in cement mortar 1 2 and curing etc. complete.
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete.
Providing and erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Estimate No. :115460-2 of 2022-2023 Supplying and erecting triple pole mini feeder pillar with 500V 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles self locks gasket having IP54 IK10 protection and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying and erecting GI sheet 1.6mm (16 SWG) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in Marathi Hindi and English erected at position for HV/EHV (11000 Volts) installation with compliance to IS 2551-1982
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting self-locking arrangement with keys in duplicate made of brass of grade 1 compliance to IS 729-1979 duly erected flush with surface of panel / cupboard
Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 3x240V 50 Hz with optical & RS 232 port backlit LCD measure & display trivector energy load survey TOD tamper detection & logging power ON /OFF events instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE insulated galvanised steel formed wire armoured (strip) cable 22 kV(E) 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Providing and erecting Heat shrinkable out door termination kit for 11 kV (UE)/ 22 kV (E) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete.
Supplying and erecting end pole D. P. Structure for 11/0.415 kV 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100mm x 116 mm x 11 m Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 400 Amps as incomer & 6 Nos.200 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set L.A. A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box Transformer Belt etc.as per drawing (min. 124 Kg. iron work) with necessary clamps Nut-bolts. V cross arm top clip insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP (GOD+LA+DO+N+TF+FP+DB)
Supplying, installing, testing and commissioning of 3 phase 22/0.433 kV 50 Hz. 160 kVA Mineral oil immersed and naturally cooled outdoor type aluminium wound Non-sealed transformer delta/star connected with additional neutral brought out on load side temperature rise should not exceed 40? by thermometer in oil and 45 by the resistance method in winding at full load rating using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +2.5 to -5 in steps of 2.5% having 4 number of tap positions with standard accessories complete with test certificate with losses below 704 Watts at 50% load 2048 Watts at 100% load as per IS 1180 (part 1) 2014 with necessary permissions of Electrical Inspector as per specification no SS- TR-NSL.
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 900 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class GI pipe with angle iron supports chain link wire mesh (jali) complete supported on channel iron erected in foundation and painted complete as per specification no SS-AS/DLD
Providing printed instruction chart for treating persons suffering from electric shock printed in English & Marathi and duly laminated complete.
Providing pair of duly tested rubber hand gloves as per IS 47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream medicine for use on wounds due burn crepe bandage gauge bandage medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use scissors anti-septic solution etc. (All above contents shall be of standard makes)
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete.
Providing Round bottom fire bucket of 9 Litres capacity as per IS 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark on provided stand/ wall hook complete.
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Estimate No. :115460-3 of 2022-2023 Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing having system lumens output of Min. 4400 Lumens min. efficacy of 110 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.95 operating range of 140-270V inbuilt surge protection of 10 kV Life class of 50 000 Hrs. at L70B50 including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing having system lumens output of Min. 12000 Lumens min. efficacy of 120 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.90 operating range of 140-270V inbuilt surge protection of 4 kV Life class of 50 000 Hrs. at L70B50 including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying, erecting and marking SPMCB 0.5A to 5A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete.
Supplying and erecting 16 m (clear height) motorized high-mast (Top-150mm Bottom-410 mm) hot dipped galvanized material with average minimum thickness 65 micron made from high tensile structure grade steel as per BSEN -10025 S 355/E350 & 3 mm thickness with base plate 25 mm thick x OD 570 mm grade as per IS-2062 pole made in single section & submerge arc welded with lowering & raising motorized unit wire rope stainless steel 316 grade 2 nos. 7x19 construction 6 mm SG-DG U clamps double drum winch assembly 350 kg 5x2.5 sq.mm flexible copper cable with lantern carriage assembly suitable for max. 16 nos. luminaires and its control gear box lightning arrestor arrangement for fixing aviation light high-mast with serial number factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete. specification no. OH-PL/HM (excluding luminaries)
Providing and erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer 24hr astronomical time switch with minimum 5 years battery backup IP 54 and IK10 protection 25 A TP contactor for automatic switching of luminaires 2 no. 9A contactors and raise/lower push button and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles self lock gasket and slanting top erected on CC foundation complete.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [HIGH MAST-2 FEEDER PILLAR-2 & STRRET LIGHT CONTROL PANEL-1]
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel concrete excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 16 m aising lowering high mast).
Estimate No. :115460-4 of 2022-2023 Supplying and erecting iron work sheetmetal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. (75mm X75mm X 5mm = 5.75 Kg/mtr Channel required for external hydrant box framing total hydrant valve - 12nos. Qty required for one hydrant valve 5.6 mtr hence 5.75 X 5.6 X 12nos. = 389.85kg 4 nos Pumproom header support - 4 pumps X 4 mtreach pump = 7mtr X 5.75= 41 Kghence total = 431 Kg)
Supplying, erecting & terminating FR XLPEinsulated galvanised steel formed wirearmoured (strip) cable 1100 V 4 core 16sq. mm. copper conductor completeerected with glands & lugs on wall/trusses/ pole or laid in provided trench/pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 50 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing and erecting hot dippedgalvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories.
Providing and erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying, installing, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 1800 to 2280 LPM at 80 to 60 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 37kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal type single stage centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325. (c) M.S. fabricated Common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/EP
Supplying, installing, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type multi stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete as per specification no. FF-MFP/JP
Supplying, installing, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following Horizontal type single stage centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade) mechanical seal conforming to IS 1520. Water cooled with radiator diesel engine conforming to relevant IS standard complete with auto starting mechanism 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v 50Hz AC supply diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding residential silencer instruments and protection as per standard specification stop solenoid for auto stop in the event of fault with audio indications etc. as required. M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/SSC/DP
Supplying, installing, testing and commissioning of Supplying erecting testing & commissioning of fire pump control panel (FCP) of cubical construction floor mounted type fabricated from minimum 2 mm thick CRCA sheet compartmentalised with hinged lockable doors with enclosure protection class IP54 duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) cable alley interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories mountings and internal wiring with adequate size copper conductor cable earth terminals numbering etc. complete in all respect suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories wiring & cabling along with allied accessories with following incoming and outgoings suitable for automatic & manual operation on 415V 3 phase 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows Main fire pump(MFP) having capacity of 22kW 1no (1 working) Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby alternate run per start in auto mode) comprises of the following features & switchgears Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU's starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. ADD ON A2 For addition of capacity of main electric motor driven fire pump MFP (1 working) for hydrant system is more than 22kW add as follows in the basic cost of Item no 13-5-1 towards increased capacity switchgears and motor starters for main & jockey pumps along with necessary accessories for main & jockey fire pumps MFP=(1working) JP = (1working + 1standby alternate run per start in auto mode) For main electric motor driven fire hydrant system pump of 55kW capacity & relevant capacity jockey pump add Rs… ADD ON B3- For addition of fire sprinkler system to basic fire hydrant system control For main electric motor driven fire hydrant system pump of 37kW capacity & relevant capacity jockey pump add Rs….
Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system.
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Supplying and erecting 100 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV
Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia cast iron double flange ball type NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV
Supplying and erecting 150 mm dia cast iron double flange ball type NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating as per specification no. FF-VL/GV
Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating as per specification no. FF-VL/GV
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and installing one piece moulded HDPE / fibre water tank for negative suction only having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and erecting 63mm dia reinforced rubber lined (R.R.L.) hose pipe 15m in length fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia for supplying water in fire tank complete as per specification no. FF-FA/FMC
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT
Supplying and erecting 20/25mm dia gun metal air release cock with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting 100 mm dia. pressure gauge 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve erected with provided G.I. pipe elbow etc. complete as per specification no. FF-FFA/PG
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve G.I. nipple elbow etc complete as per specification no. FF-FFA/PS
Supplying and erecting brass orifice plate having 6 mm. thickness 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve hose pipe hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8 x6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying, installing, testing and commissioning of FR XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, erecting, testing and commissioning of 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
Supplying, erecting, testing and commissioning of 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC
Supplying, erecting, testing and commissioning of rust free microphone floor stand of chrome plating/powder coating or S.S. material 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete.
Supplying, erecting, testing and commissioning of rust free microphone table stand of chrome plating/powder coating or S.S. material up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete.
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.0 sq. mm speaker wire complete.
Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler 15 mm (½ ) dia. NBCM Body chrome finished 68r C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR.
Supplying, erecting, testing and commissioning of vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.
Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Making cement concrete foundation in 1 2 4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
Supplying and erecting ISI mark GI pipe 32 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP.
Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete.
Making trench in hard murum/Tar road having 0.9 m depth and minimum 0.3mtr width for laying provided cables of voltage range 3.3 kV to 11 kV complete as per specification No. CW-EXN-CTR
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel central processing unit with the 8 loop capacity and capable of supporting upto 250 devices and detectors per loop with on-board LCD display with min 16 lines of text operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition suitable provision for network connectivity interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908 2021 IS 2189 2008 EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
Supplying, installing, testing and commissioning of addressable optical smoke detector single/twin LED’s with 360 degree view suitable for low voltage 15 to 32 V DC two wires supply in-built locking mechanism to check the removal and pilferage of the detector in built isolation mode start up current 300µA and alarm condition current shall be maximum 6.5 mA operating temperature 0°C to 50°C humidity 0-95% RH IP 41 conforming to IS 2189 2008 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD.
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors in built isolation mode suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS 2175 - 1988 reaffirmed 2000 IS 15908 2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type) made of addressable break glass plastic square in shape surface/flush mounted with Break Glass massage embedded on the glass complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 reed relays EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 Reed relays FF-AFAS/MM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement arranty conforming to IS 5051Part 2 (Sec 1 to 3) 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908 2021 with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54 conforming to IS 2189 2008 IS 15908 2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying and erecting 200 mm dia cast iron double flange ball type NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV
Supplying and erecting 1000 mm long 25 mm dia. Stainless steel flexible Dropper pipe (hose) for dropping sprinkler below false ceiling. Pipe shall have 16 bar rating and with union/reducer coller clamps etc. as required. Pipe shall have UL listing.
Supply & fixing of approved type rosette plates (Recessed type in two piece) for Sprinklers below false ceiling area and the finish shall be powder coated and color shall be as approved by Engineer-in-charge
Supplying & installation auto glow (Viewing upto 15 mtr length) fire signages viz fir hydrant Fir Ex inguishers Fire Exit Fire door Fire house box ect. Size of 300x100 mm
Supplying & installation auto glow (Viewing upto 15 mtr length) fire signages viz fir hydrant Fir Ex inguishers Fire Exit Fire door Fire house box ect. Size of 450x150 mm(NCSR)
Supplying & installing auto glow (Viewing upto 15 Mtr length) fire signages viz Fire Hydrant Fire Extinguishers Fire Exit Fire Door Fire Hose Box etc. Size of 600 X 200 mm [NON-CSR]
Providing Round bottom fire bucket of 9 Litres capacity as per IS 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark on provided stand/wall hook complete.
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Estimate No. :115460-5 of 2022-2023 Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629 1985 to be used for fabrication of boxes panel boards etc. including cutting bending drilling welding riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629 1985 to be used for fabrication of boxes panel boards etc. including cutting bending drilling welding riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
Supplying, erecting, testing and commissioning of manually operated opposed blade duct mounted flanged volume control dampers of required sizes in GI construction with operating mechanism mounting arrangement rubber refrigerant kits etc. complete.
Supply, fabrication, installation and testing of flexible canvas connections constructed between ductable unit/dampers/ducting of suitable size with fire resist flexible double canvas sleeve complete.
Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°.
Supply Installation Testing and Commissioning of approved make Exhaust air fan of capacity 30000 CFM for extract air complete with Ceiling suspended forward / backward curved DIDW centrifugal fan sheet as specified. Fan shall be suitable for operation on 415/230 ± 10% volts 50 Hz 3/1 phase AC power supply. [basement]
Supply Installation Testing and Commissioning of approved make Exhaust air fan of capacity 21500 CFM for extract air complete with Ceiling suspended forward / backward curved DIDW centrifugal fan sheet as specified. Fan shall be suitable for operation on 415/230 ± 10% volts 50 Hz 3/1 phase AC power supply. [1st+2nd fl]
Supply Installation testing & Commossioning of Fresh Air/Exhaust Air Louvers constructed in Extruded Aluminium .Blade inclined at 45 degreee
Estimate No. :115460-6 of 2022-2023 Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC
Supplying and erecting 10m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete.
Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK
Supplying and fixing 12 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for termination of optical fibre cables in provided U rack complete as per specification no. WG-NAS/LIU
Supplying, fixing, and configuring 1-port mini-GBIC SX MM fibre transceiver (up to 550m, support 3.3V power) erected in provided rack complete.
Supplying and erecting LSZH armoured multimode optical fibre cable with 6 fibres, core dia 50/125 µm (OM3), suitable upto 10 GBPS, ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-COC/OFC LSZH
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying, Erecting and Commissioning of push button telephone instrument desk top unit as per specification complete
Supplying and erecting 50 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying, Erecting and Commissioning of digital (hybrid) type EPABX of 6 x 16 extension complete.
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying and fixing 3 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring 20 Ports + 4 SFP combo, Layer 2, GB managed ethernet switch, with web view/CLI erected in provided rack complete
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no.WG-NAS/PP
Item No. 56 - Blank
Supplying and erecting Supplying erecting testing & commissioning of NVR32 Channel professional series 4K HD Network Video Recorder . Smart H.265+/H.265/Samrt H.264+. Max 320Mbps Incoming Bandwidth .Up to 12MP Resolution for Preview& Playback Bit Rate 16Kbps20Mbps per channel . 2HDMI/2VGA simultaneous video output to enhance the storage eliability when the network break down . Quad-Core embeded processor . 8 SATA III Ports Up to 6 TB for each HDD for 48TB Storage 2 RJ45 port (10/100/1000Mbps) Independent of Joint Networking. Analytical Features Like - ANPR People Count Face Detection Missing/Abondoned Objects Tripwire and Intrusion alarms Smart FAN to achive High Cooling Effect .Automatic Network the video data stored on the camera. (3 years warranty)
Supply Installation and commissioning of 42 Full HD VGA DVL 2 x HDMI LAN USB RGS n out Avin Component in vwii roady speakers professional full HD dispiay complete with mounung hardware and software 200 tumpiete included to create your own content manage conlent with suggested PC or mobile device A professional dispiay backed by three years onsite/oftsite warranty and dedicated B26 support (3 yeaS warrantv]
Surveillance hard disk 4 TB storage apacity with SATA support 6GB/s NCQ 64 MB cache 3.5 inches (3 years warranty)
Estimate No. :115460-7 of 2022-2023 Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP
Supplying and erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying and erecting automatic control panel for 3 Phase 415 volt A.C Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP S.P.P. Combined ammeter/ voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc.
Supplying and erecting non return valve 40 mm dia in position made of gun metal complete.
Supplying and erecting 40 mm. dia. gun metal sluice valve at position with necessary materials complete.
Supplying and erecting ISI mark GI pipe 40 mm. dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
Supplying, erecting and marking FPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying and erecting four pole ON LOAD change over switch 415V 40A open execution having staggered termination phase barrier shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit rotary handle operational current category AC23A complying to IS/IEC 60947-3 Part-1/3.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP
Estimate No. :115460-8 of 2022-2023 SITC of Electric Traction Goods Lift with Rated capacity - 3000Kg Goods/44 Passengers · Floors - G+3 floor (4Stops/4 Landings) · Travel - 3 to 4.2 mtrs (12 MTR) Location of Lift Machine - MRL Rated speed - 1.0mps VS· Doors type - COPO/TOPO Doors with frame having clear opening of 1800mm wide x 2000mm high made from SS 304 grade sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames· Lift car enclosure made from SS 304 grade sheet of 1.5mm thick with hairline finish with frame made from MS girders bracing of adequate size with minimum safety factor of 5 with Toe Guard Apron with necessary false ceiling with adequate LED lights blower/fan for ventilation & SS chequered plate flooring handrails mirror emergency light etc.· COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI scrolling UP/DN LED indicator & with/without attendant key switch OWD with audio-visual alarm VAS in Marathi Hindi & English with intercom system with telephone instrument in Lift car LMR & FCC/ground floor Clear Car size of 2000mm wide x 3000mm deep x 2000mm high · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI Lift car arrival & next travel direction audio-visual indication at all landings· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system with IBMS compatible having necessary port control panel duly wired with proper size & strength copper wire for power & control circuit with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class ARD complete with necessary SMF VRLA batteries Fireman controller having fireman switch at fire Landing CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18 FHD TV monitor to be kept in FCC/LMR as directed by Engineer In Charge.· Lift Machine of Gearless PMSM of suitable kW with Traction pulley OSG electromagnetic brakes entire assembly mounted on adequate size girders duly
ADD ON FOR LIFT - For Lift having 1800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade landing door [Four panel] this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators extension of guide rails shaft wiring with trunking travelling cables main hoisting ropes/belts & OSG rope landing doors with all accessories etc necessary for the normal safe functioning of lift installation complete.
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting and marking DPMCB 6 A to 32 A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting and marking FPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying, fixing, and commissioning 4 pole RCBO 32/40A with overcurrent rated short-circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block /wooden board with 3 years warranty.
Supplying and erecting Ceiling rose /Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendant holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box.
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials testing & recording the results as per specification no. EA-EP
Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete.
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Estimate No. :115460-9 of 2022-2023 Supplying, installing, testing and commissioning of cassette type room Air conditioning unit 2.8TR to 3.3TR capacity with refrigerant R32/R410A 415V 50 Hz A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit dust filter noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying, installing, testing and commissioning of cassette type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room Air conditioning unit 2.5TR to 2.7TR capacity having ISEER minimum 5.00 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32/R410A having copper condenser dust filter self diagnosis feature stabilizer free operation noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying, installing, testing and commissioning of cassette type room Air conditioning unit 4TR to 4.4TR capacity with refrigerant R32/410A 415V 50 Hz A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit minimum dust filter noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater/AC system.
Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Estimate No. :115460-10 of 2022-2023 Providing and erecting 4 Pole MCCB 415V 200A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withst and capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying and erecting SS enclosure for MCCB suitable for 125A to 200A MCCB.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
diesel generating set with alternator of 125 kVA output continuous rating 3 Phase 415 V 50c/s 0.8 p. f. A.C supply a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours along with standard accessories self-excited self-regulated screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 % with performance class G2 and maximum fuel consumption 21.4 Ltr/hr 75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters switchgears indicators connected with suitable wires/cables the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet sound absorbing material to restrict sound level up to 75 dB at 1.0 m provided with first filling of oil diesel not less than 230 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
microprocessor based AMF panel suitable for diesel generating set of above 100 kVA up to 125 kVA capacity Three phase 415 Volts 50Hz A.C. with all standard features safeties etc as per specification no. GEN-AMF.
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables pipes & clearing the site by removing debris & making the site as required complete.[3.95X1.7X0.5=3.35]
Making cement concrete foundation in 1 3 6 cement concrete (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).[3.95X1.7X1=6.71]
Estimate No. :115460-11 of 2022-2023 Supplying, installing, testing and commissioning of 20 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 60 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnecting wires / cables up to solar ON GRID inverter proper base plate canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB MCB etc. wiring up to solar Inverter in casing and capping display board sign board two distinct earthing lightning arrester liaisoning charges remote monitoring system with maintaining card/chip for 5 years including net charges for RMS System complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG.
Providing and erecting 3 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying and erecting SS enclosure for MCCB suitable for up to 100A MCCB.
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws wall fasteners supports nut bolts etc. complete with compliance to IS 720 2010
Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 3x240V 50 Hz with optical & RS 232 port backlit LCD measure & display trivector energy load survey TOD tamper detection & logging power ON /OFF events instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.
Supplying and erecting AC three phase LT CT multifunction net meter DLMS compliance of accuracy class 0.5 3 x 240V 50Hz with backlit LCD display optical port & RS 232 port (measures import kWh kVAh export kWh kVAh Net kWh kVAh V I kW 6 months history of energy load survey TOD tamper detection & logging power ON/OFF events instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.
Supplying and erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Shubham EPC Private Limited
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid