| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | ₹15.8 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹15.8 L+₹1,087 (0.07%)Rejected-Finance | ₹15.8 L+₹1,087 (0.07%) | L2 | Rejected-Finance Not lowest bidder |
| 3 | L3₹16.7 L+₹86,127 (5.44%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | ₹16.7 L+₹86,127 (5.44%) | L3 | Rejected-Finance Not lowest bidder |
| 4 | L4₹19.0 L+₹3.1 L (19.8%)Rejected-Finance SHOP NO 13 MOHINI MARKET KISHORE BAGH MANDORE JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | ₹19.0 L+₹3.1 L (19.8%) | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹15.0 L
EMD Value
₹29,920
Closing Date
3 Apr 2023, 6:00 pmClosed
Garrison Engineer, Banar
Garrison Engineer, Banar, Jodhpur-342027
REPAIR/MAINT OF SOLAR LIGHTS, HIGHT MAST LIGHTS AND CONNECTED ITEMS IN AA BANAR
2023_MES_578902_2
8822/77/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Banar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer, Banar
₹29,920
Yes
20 Apr 2023
13 Mar 2023
5 Apr 2023
13 Mar 2023
3 Apr 2023
20 Mar 2023
Amount
M&L for cleaning of solar street light panel of any capacity located at elevated height up to 6 Mtr on pole, cleaning from dust, dirt, leaves, bird dropping including cleaning of glass plate with soft and warm water, soap solution or glass cleaning solution to make the fully functional solar street light fitting complete all as specified. Note:- The recored of cleaning will be maintained by contractor duly singed by Engineer-in-charge.
Supply and fixing in replacement of Solar Charge Controller 5/10 Amp with protection circuits suitable for 12 to 36 watt Solar Light complete all as specified. System: 12V Nominal Capacity: 50Wp Max Regulation: Low Loss, Shunt Type OVD: Output Voltage Drop<200mV at 2.1A Load IVD: Input Voltage Drop<330mV at 10A Charge LVD: Low Voltage Disconnect, 10.8V HVD: High Voltage Disconnect,14.2V LVR: Low Voltage Reconnect, 12.3V HVR: High Voltage Reconnect, 14.15V Battery Charging Type: PWM Protections: Short Circuit and Overload at load Reverse polarity of battery and panel
Supply and fixing in replacement of PIR Motion Sensor 170uA suitable for 12 to 36 watt Solar Light Standard Detection 5m complete all as specified. Lens Color : White Conditions Concerning target 1. The temperature difference between the target and the surroundings should be superior to 4 deg C 2. Movement speed : 1.0m/s 3. Target concept is human body ( Size 700x250mm)
Supply and fixing in replacement Motion Sensor Cap for solar lights of any watts complete all as specified.
Supply & fixing in replacement of Lithium Battery 12.8/28.6 Ah with BMS Circuit and other necessary wires and connectors suitable for 16 to 36 watt Integrated Solar Lights complete all as specified.
Supply & fixing in replacement of Rocker Switch 6Amp for solar lights complete all as specified.
Material and labour for replacement of lead acid maintenance free Solar battery , 12 volt, 150 AH suitable for solar street lights complete all as specified.
Supply and fixing in replacement of Lithium based Energy Efficient Integrated Solar Street Light of 24 Watt” in Single FRP body with duly Polyurethane coating (Camouflage color) , encases with Monocrystalline Solar PV Panel of 53/55Wp , Lithium Battery 11.1/12.8V, 28.6AH with inbuilt BMS, IP 66 & IK08, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function (first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 12-14kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required. Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant. Note: Old Solar panel shall be deposited to MES store yard as directed by Engr-in-Charge.
Supply and pouring the electrolite suitable for solar street lights battery of capacity 120/150 AH upto 5 mtr height and check the specific gravity of electrolite, maintaine the adequate specific gravity including adding the sulphuric acid if required complete all as specified.
Supply and fixing in repair PVC insulated 3 core 1.5 Sqmm stranded copper conductor cable for connecting from solar battery to voltaic solar panel and light fitting testing and commissioning complete all as specified.
M&L to carryout repair to high mast light at height up to 13 mtr, servicing of light carrying with and gear box alongwith SWR rope complete with replacing the minor parts like nut bolts, SWR rope and connected items complete all as specified.
Supply and fixing in replacement of power contactor of 415 volts 50Hz, 50 Amp capacity with 230 volts operated coil on existing panel of highmast control panel complete all as specified.
S&F in replacement of automatic street light switch for 3 phase 415 Volt, load of 8 KW using infrared sensor technology based nature switch & voltage Monitoring system (VMS) for automatic switching of street lights. Nature switch operation should be based on natural light Lux* level. Required illuminance level for switching ON is < 60 Lux and for switching off > 10 Lux. The sensor should also have part night operation facility of min. 4 hrs to max 12 hrs. The sensor along with suitable 3 Nos power contractors rating 25-32 Amp each and 03 Nos incoming MCB's & 3 Nos outgoing MCB's of 20-32 Amp each & circuit wiring (Copper) of min 10 Sqmm with lugs and auto manual option (i.e. Sensor by Pass option) should be enclosed in a pole /wall mountable enclosure made of Rust proof, electric shock proof, termite proof and RF grade SMC junction box confirming to IP 66 complete all as specified.
Supply and fixing in repair PVC insulated 5 core 4.0 Sqmm stranded copper conductor cable for connecting from highmast control panel to light fittings by inserting the cable through highmast pole inside complete all as specified.
Supply and fixing in replacement of LED driver suitable for flood lights fitted on high mast lights of 150 Watt capacity complete all as specified.
Supply and fixing in replacement of surge protctor for flood lights fixed on highmast light pole of 150 Watt complete all as specified.
Supply & Fixing in replacement of medium class tubular galvanized pole 6 mtr long of X-section/dia 75 mm with 16 mm thick MS base plate of size 250mmx250mmx with 4 Nos 25 mm hole and foundation bolt of 20mmx750mm long complete with excavation earth work including PCC 1:3:6 type C-2 using 40mm graded stone aggregate for foundation of size 300x300x900mm and PCC 1:2:4 type B-1 using 20mm graded stote aggregate for coping of size 300x300x450mm complete all as specified.
Supply and fixing in replacement of LED flood light fitting 100 watts (with total lumen output not less than 10000 lumens/Watt) with ingress protection IP 66 and external SPD of capacity 10 KV in addition to inbuilt SPD of electronic driver, having Pressure die cast housing with high efficient output emitter LED for better distribution, protection with heat resistant toughened glass with individual LED lenses complete including MS clamps of suitable size for fixing on High Mast/Pole complete all as specified.
Material and labour for replacement of Solar LED street light fitting , 26 watt , operating voltage 12 volts, system efficiency 100 watt, IP 65 protection for solar street light complete all as specified.
G R CHOUDHARY AND SONS
Anil Builders
Sachiyay maa Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .