Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹37.2 L+₹1.7 L (4.84%)Rejected-AOC 796 AZAD NAGAR ROORKEE UK 247 667 | HARIDWAR | UTTARAKHAND | 247667 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹47.3 L+₹11.9 L (33.4%)Rejected-AOC PREM NAGAR GALI NO 3 RAJPUTANA SALEMPUR ROORKEE DISTT HARIDWAR UK | ROORKEE | HARIDWAR | UTTARAKHAND | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹66,600
Closing Date
21 Dec 2020, 6:00 pmClosed
G E ROORKEE
G E ROORKEE
ADDN ALTN TO BLDG NO P 1039 AT BEG AND C ROORKEE ADDN ALTN TO TECHNICAL BLDG AT BEG AND C ROORKEE PROVN OF COVERED STORAGE SHED IN BLDG NO P 516 AT BEG AND C ROORKEE AND PROVN OF A GUARD ROOM AT DHILLON MARG AT BEG AND C ROORKEE UNDER GE ROORKEE
2020_MES_397263_1
8391/974/E8
Open Tender
Civil Works
Item Rate
120 days
ROORKEE CANTT
AS PER NIT
6 documents required · 6 mandatory
₹500
G E ROORKEE
₹66,600
Yes
14 Jan 2021
23 Nov 2020
23 Dec 2020
23 Nov 2020
21 Dec 2020
7 Dec 2020
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soil complete all as specified and directed.
Removing excavated surplus soil at a distance n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surfaces (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for approved earth brought from out side the MOD land for filling under floor complete all as specified and directed.
M&L for plain cement concrete(1:3:6) Type C2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M&L for brickwork with old size sub class ‘B’ bricks in cement mortar (1:4), straight or curved on plan exc 6m mean radius complete all as specified and directed.
M&L for cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in cills, copings, bed blocks, apex stones including necessary form work etc complete all as specified and directed.
S&F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
M&L for preparing wood and wood based materials surfaces, new or old, of any description and girth, not otherwise described and treated with creosote oil complete all as specified and directed.
S&F Ist class hard wood 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc, sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), supplied and fitted to chowkat complete all as specified and directed.
S&F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 Sqm in each pane complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.00mm, fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S&F 75 mm size stainless steel hinges (ISI Marked) and fixed complete all as specified and directed.
S&F 150mm size brass barrel tower bolts with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and directed.
S&F 150 mm long brass handles, cast type, polished bright and fixed complete all as specified and directed.
M&L for 75 mm thick cement concrete (1:5:10) type E-2 (usins 40mm graded aggregate) as in sub base for laying further floor finishes and the like complete all as specified and directd.
M&L for double charged virified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 Sqm but n.exc 0.42 Sqm, laid in floors etc over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of colour of tiles complete all as specified and directed.
All as per serial item No. 21.00 above but on vertical surfaces as in dado/skirting complete all as specified and directed.
M&L for 12mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in two coats, Ist coat 10mm thick in cement mortar (1:6) and IInd/finishing coat 5mm thick in cement mortar (1:4) on other than fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for coloured glazed ceramic tiles of size 350x 250x 7 mm or 450X 350X 7mm thick in vertical surface, laid over and including 10mm thick rendering coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of colour tiles complete all as specified and directed.
M&L for hard core of broken bricks, broken to gauge n.exc 63 mm, laid in any thickness including watering and well ramming to a true surface complete all as specified and directed.
M&L for 75mm thick cement concrete (1:3:6) type C-2, (using 40mm graded stone aggregate) as in plinth protection, finished even and smooth without using extra cement complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed.
S&F rolled mild steel joist, channel, angle, or tee sections, fixed independently without connecting plates etc (cut to ordinary lengths i.e. within 20mm of the length) as indicated conforming to FE-410 -W grade E-250 complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for providing and fixing in position, suspended false ceiling using GI exposed ceiling suspension system of grid size 600mm x 600mm with main runner 32x 15mm, cross T 32mm x15mm and wall angle 20mm x14mm, using 3.2mm thick (high pressure steam cured), pre-painted, UV film coated, self-embossed reinforced heavy duty fiber cement board of pearl texture variant confirming to IS-14862: 2000, placed in GI grid system duly suspend with 4mm dia GI/ MS bar hanger fixed with steel dash fastner or iron purlin from the roof/ wooden/iron purlin with adjustment clip, providing provision for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runner to be secured to structural soffit by hanger @ 1200mm C/C. The last hanger at the end fitting 1200mm cross T to be interlocked between main runners @ 600mm C/C, so as to form 600mm x600mm grid complete all as specified and directed.
S&F 100 mm size mortice latch with two levers (vertical type), mild steel body complete all as specified and directed.
S&F solar control film 25 micron reflective type dark tinted, sticked to glass plane as per manufacturer's instructions all as specified and directed.
M&L for preparing new wooden or wood base surfaces of any description, width or girth including cleaning surafces and applying two or more coats of french polish to give glossy finish including a coat of wood filler complete all as specified and directed.
Excavation in post holes (or similar holes) each n.exc 0.5 Cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25 cm and removal of surplus soil to a distance n.exc 50 m and making good surface complete all as specified and directed.
S&F mild steel work as in posts/struts (angle, flat, nut boits etc) in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc including necessary welding conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including a coat of primer with red oxide complete all as specified and directed.
S&F glavanised two strand steel barbed wire 2.24 mm dia, barbed with 2mm dia berbs at 75mm spacing, straining and fixing to any type of standard rails with straning bolts including secureing or tying at crossings with and provn of galvanised mild steel wire staple or pins etc complete all as specified and directed.
Supply only mild steel galvanised chain link fencing of any size complete all as specified and directed.
Fixing only chain link fencing including line wires any mesh, size and fixed to any type of standard rails, straining bolts etc including provn of binding wire complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm (Nominal area) PVC insulated, unsheathed FRLS multi stranded copper conductor single core cable, drawn through and including PVC non metallic concealed conduit of 20 mm dia (ISI marked) with all accessories including sunk mild steel 1.6 mm thick terminal boxe with 3 mm thick bakelite sheet top cover (ISI marked) complete including PVC insulated and unsheathed single core multistranded copper conductor cable of size 1.5 Sqmm of green colour as earth continuity conductor connected to common earth and earth dolly including cutting chases etc and making good surfaces in cement mortar (1:4) and applying decorative finishes to match with the existing surfaces of walls/celing etc complete all as specified and directed for the following :-
One ceiling fan and exhaust fan point controlled by one one way switch .
One socket point on independent board controlled by one one way switch .
All as per Serial item No. 43.00 above but with 2.5 Sqmm (Nominal area) PVC insulated and PVC unsheathed FRLS multi stranded copper conductor single core cable for 15 Amps 3/5 socket power point including single core multistranded unseathed copper conductor cable of size 1.5 sqmm of green colour for earth continuity complete all as specified and directed.
S&F switch piano flush type polycarbonate 5/6 Amps single pole one way complete all as specified and directed.
S&F switch piano flush type polycarbonate 15/16 Amps single pole one way complete all as specified and directed.
S&F socket outlet flush type polycarbonate 2 in 1, 3 pin 5 Amps complete all as specified and directed.
S&F socket outlet flush type polycarbonate 2 in 1, 3/5 pin 5/15 Amps complete all as specified and directed.
M&L for ceiling rose of polycarbonate 3 terminal brass flush type 6 Amps, 230 Volts AC (ISI marked), fixing on 3 mm thick sunmica hylum plastic laminated round sheet of 75mm dia complete all as specified and directed.
S&F electronic fan regulator 100/300 Watt, 230 Volts, step type (5 steps) socket type, hum free complete all as specified and directed.
S&F MCB DB, SPN 4 way, IP-43 double door, flush to wall complete all specified and directed. Make- Legrand Cat No. 507620 or equivalent model in Havells /ABB /C&S
S&F MCB SPN 32 Amps, AC 230 Volts, 'C' curve with 10 KA breaking capacity including necessary lugs Lugs/Thimbles etc complete all as specified and directed.
S&F MCB SP 6-32 Amps, AC 230 Volts, 'C' curve with 10 KA breaking capacity including necessary lugs Lugs/Thimbles etc complete all as specified and directed.
S&F LED tube light fitting 1x18/20 Watt with 1220mm LED tube rod T8, suitable for single phase 230 Volts, 50 Hz AC supply with all accessories internally prewired including connecting up with three core flexible copper conductor cable of size 0.5 Sqmm (Nominal area) complete all as specified and directed. Make - C&S Cat no. LTDC01220WLED/WD or equivalent model in Philips /Havells/ Wipro
S&F reccess mounting light fitting 2'x2' of capacity 36 watts, powder coated, white CRCA full glow suitable for 600x600 mm POP false ceiling including making electrical connection from ceiling rose to light fitting with three core flexible copper conductor cable of size 0.5 Sqmm (Nominal area) complete all as specified and directed. Make - C&S Cat no. LTCRP36WLED2x2 or equivalent model in Philips /Havells/ Wipro
S&F energy efficient ceiling fan, 1200mm sweep, 40 watt power consumption, 350 RPM, 218 air delivery, BEE five star rating fan, colour in Bianco, Aerodynamic blade, 230 Volt and hanging clamp of suitable size made out of MS flat iron of size not less than 50x5 mm, nut-bolt and washer complete all as specified and directed by Engineer-in-charge. Make : Havells or equivalent in USHA/Bajaj
S&F exhaust fan 250/300 mm sweep, metal body with louvers including cutting hole in existing brick wall for fixing exhaust fan and making good in cement mortar (1:4) including applying decorative finishes to match the existing surfaces complete all as specified and directed.
S&F water cooler electric driven, single phase having nominal cooling capacity 40 Ltrs and storage capacity 80 Ltrs with the following fittings and fixtures complete all as specified and directed:- (a) Push type bib cock- 02 Nos. (b) Float valve - 01 No. (c) Waste water tray and waste water pipe- 01 No. (d) PCC foundation for mounting water cooler of dimensions and specifications as directed at site. (e) Plumbing work as required including stop valve, GI pipe medium grade, PVC connection etc as required for proper functioning of water cooler will be deemed included in the scope of this item and nothing extra to be paid. Make :- Voltas, Blue-star, LG, Carrier
S&F Voltage stabilizer of capacity 2 KVA for auto correction of line voltage 160 Volt - 250 Volt range, single phase, wall mounted type, with digital Voltmeter complete all as specified and directed. Make :- Microtek, Luminus, V-Guard
S&F Desert cooler 4000 Cum/Hr, metal body made out of 16 gauge CGI sheet with angle iron base frame made of angle iron of size 25x25x5mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Make of Fan Motor :- Crompton, Bajaj, Usha
M&L for repair, rewinding, testing and commissioning of 100 KVA capacity transformer complete all as specified and directed. Note :- (i) Disconnecting defective transformer outdoor type platform mounted of capacity 100 KVA both from HT/LT sides, and then drain out of complete transformer oil, opening of top cover with due care and removal of all HT/LT existing winding connections from bushing and then lifting of core by means of tripod and chain pulley for inspection and ascertain it’s serviceability state after keeping it aside. Removal of all sludge and unwanted material from tank and core, lowering of core assembly after carrying out required repairs to the winding and core. (ii) The cost of transportation from work site to work shop and back shall be deemed to be included in the quoted rates. (iii) The cost of rewinding of primary and secondary windings of existing gauge and size shall be deemed to be included in the item rate. (iv) The cost of dehydration/filtration & other necessary repair as directed shall be deemed to be included in the quoted rates. (v) Additional transformer oil for top-up, if required will be filled by contractor and shall be deemed to be included in the quoted rates. (vi) Before Quoting rates the tenderers may visit the site to access the nature of repair required.
M&L for XLPE insulated screened PVC bedded galvanised steel strip or armoured eletric power cable ( heavy duty) with aluminium conductor 11000 Volt grade with cross sectional area 95 Sq mm 3 core complete all as specified and directed Make :- Havells, Polycab, Gloster
Supply, laying and testing 95 Sqmm 3.5 core, 1100 Volts, heavy duty XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power aluminium conductor cable complete all as specified and directed
Supply, laying and testing 70 Sqmm 3.5 core, 1100 Volts, heavy duty XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power aluminium conductor cable complete all as specified and directed
Supply, laying and testing 10 Sqmm 2 core, 1100 Volts, heavy duty XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power aluminium conductor cable complete all as specified and directed
Supply and laying sand river for cushioning in layers of 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified and directed. Note:- Thickness of sand cushioning to be measured as 18.00 cm after punning for payment purpose
Supply and laying brick protection cable cover using sub class ‘B’ bricks laid flat adjacent to each other across the length of cable laid dry complete all as specified & directed by Engr-in-charge.
S&F cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed.
S&F in replacement of following items in existing LT panel etc as under complete all as specified and directed. (i) MCCB 250A, 36kA, 3 pole-01 Nos (make-L&T cat No. DN2- 250D or equivalent model in Schneider /ABB. (ii) MCCB 200A, 50 kA, 3 pole-01 No (make-L&T cat No. DN1- 250N or equivalent model in Schneider /ABB. (iii) MCCB 100A, 36 kA @400V, 3 pole-01 No (make-L&T cat No. DU- 100H or equivalent model in Schneider /ABB. (iv) MCCB 63A, 10 kA@415V, 3 pole-01 No (make-L&T cat No. DU-100 or equivalent model in Schneider /ABB. (v) Change over Switch 160 A, 415V, 4 pole-01 No (make-L&T cat No. CO2-160 or equivalent model in Schneider /ABB. (vi) Digital Voltmeter 0-500V-01 No (vii) Digital Ammeter 0-300A-01 No (viii) LED phase indicators-01 Set (RYB)
M&L for repair/ testing to earthing complete including PCC masonry pit of 300x300x300mm interier dimentions in PCC (1:2:4) type B1, RCC cover with anglr iron frame complete all as specified and directed by Engineer-in-Charge.
Supply only carbon di oxide type fire extinguiser of 9 Ltrs capacity all as directed by Engineer-in-Charge.
Supply only CO2 type 5 Kg all as directed by Engineer-in-Charge.
Supply only dry chemical powder type 10 Kg pack all as directed by Engineer-in-Charge.
Supply only Fire buckets filled with dry river sand all as directed by Engineer-in-Charge.
Supply only Fire ceilling hook complete all as directed by Engineer-in-Charge.
Supply only Fire beater complete all as directed by Engineer-in-Charge.
Supply only Shovel GS complete all as directed by Engineer-in-Charge.
S&F electric motor siren conforming to IS:1941, suitable for three phase 415 Volt supply with motor not exceeding 3.75 KW power and able to deliver 143 DB noise level complete all as directed by Engineer-in-Charge.
M&L for repair, servicing, testing and commissioning of DG set 100 KVA complete all as directed by Engineer-in-Charge compersing of the following:- (i) Taking out Engine head cover and replacement of Gasket. (ii) Tuning of Fuel injection pump. (iii) Replacement of Engine oil, Oil filter, Fuel filter, Air filter, Fan Belt, Radiator coolant etc. (iv) Checking, testing and rectification of Governor and AVR pane. (v) Replacement of 12V starter unit and battery 180Ah. (f) Checking, testing and rectification of Piston cylinder and Piston Ring. (vi) Checking, testing and rectification of Control panel, Announciator panel and emergency control system. (vii) Cleaning of Fuel tank and replacement of Fuel pipes. NOTE :- (i) Before Quoting rates the tenderers may visit the site to access the nature of repair required. (ii) Cost of material and spare parts required for fully functioning of the DG Set shall be of existing make and model are deemed to be included in the quoted rate.
Supply, laying and testing 120 Sqmm 3.5 core, 1100 Volts, heavy duty XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power aluminium conductor LT cable complete all as specified and directed
S&F 80mm bore GI pipe, light grade, laid as protection pipe of cable complete all as specified and directed by Engineer-in-Charge.
M&L repairs to AMF panel complete with replacement of power contactor 3 pole, incoming MCCB, HRC fuse, Volt meter, Ammeter, relays etc complete all as specified and directed by Engineer-in-Charge compersing of the following:- (i) Power Contactor 150A, 4 pole, 415V- 01 No (Make-Meta-MEC LS Cat No. GMC-150/4 or equivalent model in Schneider /ABB. (ii) HRC Fuse Size-1, 160A, 415V-06 Nos (Make-Havells Cat No. HCD-01 or equivalent model in Schneider/ABB. (iii) Under voltage relay 3 phase, 3 wire, 415 VAC as per existing make and model-01 No. (iv) Multifunction meter digital type with 4 line display.
S&F Air termination aluminium conductor single pointed 12 mm dia 300 mm long rod omplete all as specified and directed by Engineer-in-Charge.
S&F Aluminium strip 25x3 mm including fixing on roof/wall on porcelain insulators 600 apart from each other screwed with 02 Nos screws of suitable size complete all as specified and directed.
S&F Galvanised iron strip 32x6mm fixed to wall/ground for making ground conductor complete all as specified and directed.
M&L for Test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed with 3 Nos, 8mm dia & 25mm long hexa head screws complete all as specified and directed by Engineer-in-Charge.
M&L for earthing of machinery/ equipment Installed at power house/substation using MS galvanized plate of size 600 x 600 x 6 mm as earth electrode burried directly in natural ground (depth of earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to 32 x 6 mm galvanized MS strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board including PCC masonry pit of 300x300x300mm interier dimentions in PCC (1:2:4) type B1, RCC cover with angle iron frame, charcoal dust and common salt 15cm in layers all round the earth plate, 20mm dia GI watering pipe, a funnel with wire mesh to be provided on top of watering pipe complete all as shown on electric plate No 3 of SSR 2009 including testing after completion complete all as specified and directed.
M&L for earthing of machinery/ equipment Installed at power house/substation using copper plate of size 600 x 600 x 6 mm as earth electrode burried directly in natural ground (depth of earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to 20x3 mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board including PCC masonry pit of 300x300x300mm interier dimentions in PCC (1:2:4) type B1, RCC cover with angle iron frame, charcoal dust and common salt 15cm in layers all round the earth plate, 20mm dia GI watering pipe, a funnel with wire mesh to be provided on top of watering pipe complete all as shown on electric plate No 3 of SSR 2009 including testing after completion complete all as specified and directed.
M&L for cutting groves of size 25 mm deep and 5 mm wide in existing PCC floor for incerting copper strip of size 25 x 3 mm in true vertical position for making anti-static copper strip grid of size 750x750mm, filling of cement mortar (1:1) in the grooves for fixing copper strips, cleaning the grooves and connecting copper strips to copper earthing strips complete all as specified and directed by Engineer-in-Charge for complete building having following construction:- (a) Rooms- 06 Nos of size 3.80X4.00 Mtrs (b) Varandah-01 No. of size 47.00X3.00 Mtrs. (c) Cost of Copper strip 25x3mm thick for making grid shall be deemed to be included in the quoted rate by the contractor. (d) Copper Strip 32x6mm thick of required length for connecting anti-static flooring to earthing strip is deemed to be included in the quoted rate by the tenderer.
M & L for taking out Submersible pumpset of capacity 40 HP from bore-well by dismantling column pipe, transportation for re-winding at work shop and lowering along with column pipe and electrically connecting with water proof joint after repair. The repair work comprises of the following :- Motor :- Dismantling carefully, centrifugal , vertical submersible electric motor three phase , 415 volts, of any make and model from site of installation, transporting the same to workshop , removing all brunt / worn out coil, clearing of stator slots , insertion of insulating paper in the slots of appropriate size and rewinding with super enamelled copper wire ISI marked with existing size , applying two coat of insulating varnish, ovening including all winding materials, transporting back the same and reinstallation of motor at site complete and re-assembling it after testing. Submersible Pump:- Dismantling the submersible pump, checking for repair, replacement of bushes, cleaning impellor, lathe work as per requirement and re-fixing the same at its original position complete to the entire satisfaction of Eingr-in-Charge.
M&L repair, overhauling and servicing of centrifugal pump set of capacity 25 HP including the following :- (i) Dismantling pump from foundation by un-bolting couplings, removing suction and delivery pipes. (ii) Cleaning and greasing of all moving parts. (iii) Cleaning of silt from casing and impellor. (iv) Replacement of old damaged ball bearing. (v) Re-fixing the pump at its original position, levelling, connecting suction and delivery pipes complete. (vi) Testing of pump set for required water discharge. (vii) Servicing and greasing of electric motor by disconnecting all electrical connections and re-connecting the same after repair.
S&F calcium based granuals dosing pump complete all as specified and directed by Engineer-in-Charge compersing of the following:- (i) Agitator cum Pumpset 0.5 HP for injecting chemical 5 LPH at 15 Mter head, PVC tank of capacity 100 Ltrs. (ii) Suitable dia of PVC connection pipes from pumpset to delivery water supply line fixed along the wall with suitable clamps. (iii) Supply only Calcium base granular water dis-infectant/Calcium hypochlorite in 45 Kgs container -02 Nos (Make-Aquafit, Purichlor)
S&F 50mm bore GI pipe medium grade including all GI fittings such as union. Sscket, bends etc, fixed to wall or laid in floor complete all as specified and as directed by Engineer-in-charge.
S&F 50 mm size gun metal glob or gate valve with iron wheel hand screwed both ends for iron pipe all as per latest IS specifications complete all as directed by Engineer-in-Charge.
S&F 150mm size sluice valve, cast iron body, class PN 1.6 with iron wheel and spindle complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of Star delta starter operating on 3 phase 415 volts suitable for 25 HP Moter complete all as specified and directed.
S&F Submersible cable 3 core 16 sqmm, PVC insulated seathed, multi stranded copper conductor, flat suitable for bore well complete all as specified and directed.
M&L for construction of brick masonry valve chamber of internal size 650x650x650mm with old size sub class 'B' bricks in cement mortar (1:6) with 3mm thick MS sheet cover and angle iron 40x40x6mm frame with locking arrangement duly painted with one coat of bitumen paint over a coat of red oxide primer including necessary earth work in soft/loose soil, returning filling and removing of surplus soil, cement concrete work in PCC (1:2:4) type B1, plastering in cement mortar (1:4) including 2 coats of snowcem complete all as specified and directed by Engineer-in-Charge.
KOHLI BUILDERS
M/S Konark Electric Sales Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .