Loading…
Loading…
Tender ID
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
9 Mar 2026, 6:00 pmClosed
SE ETC Shahjahanpur
Electy Trans Circle Shahjahanpur
Work
2026_UPTCL_1118156_1
84 ETC(S)/2025-26
Open Tender
Electrical Works
Fixed-rate
60 days
Lakhimpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
A/c No. 0423002100107147 IFSC Code No. PUNB0042300
₹20,000
20 Aug 2026
19 Feb 2026
10 Mar 2026
19 Feb 2026
9 Mar 2026
19 Feb 2026
19 Feb 2026 - 9 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply of GE/ZIV/Siemens/ABB make Numerical Distance Protection Relay, having 16DI+20DO, Single FO port with IEC-61850 communication protocol, IRIG-B Port, Type P442/Equiv. OR as per site specification suitable for 132kV Line Protection Panel for 132 kv mohammadi- kapraha line , 132 kv mohammadi- ajwapur line , 132 kv mohammadi- kumbhi line | 3 | Nos | - | - |
| 2 | Supply of GE/ZIV/Siemens/ABB make Numerical backup impedance relay with directional OCEF, having 8DI+8DO, Single FO Port with IEC-61850 communication protocol, IRIG-B Port, Type P14DB, GE Make/Equiv.OR as per site specification Suitable for 400/220/132 KV Transformer Relay Panel for 132 kv mohammadi- kapraha line , 132 kv mohammadi- ajwapur line , 132 kv mohammadi- kumbhi line , 132 kv lakhimpur- gulariya line & 132 kv lakhimpur- khambharkera line | 4 | Nos | - | - |
| 3 | Supply of GE/ZIV/Siemens/ABB make Numerical Non-Dir OCEF Relay, having 6DI+8DO, Single RJ-45 Port with IEC-61850, Type 7SR511-1AA11-0AA0/P1A8/REF615 OR as per site specification suitable for 220/132/33KV Protection Panel | 4 | Nos | - | - |
| 4 | Supply of Single element, High-Speed Master Trip Relay, Aux supply 110VDC, 2NO+4NC OR as per site specification, HRC, HRF, Avana Make/Equiv., suitable for installed C&R Panel | 6 | Nos | - | - |
| 5 | Supply of DC fault supervision relay, Aux supply 110VDC, 2NO+2NCOR as per site specification, SRC LED Indication, Flush Mounting, Avana make/Equiv., suitable for installed C&R Panel for 132 kv lakhimpur- gulariya line & 132 kv lakhimpur- khambharkera line | 2 | Nos | - | - |
| 6 | Retrofitting of numerical Distance relay P442/Equivalent with proper mounting and re-wiring in existing panel with proper dressing, ferruling and termination. Complete configuration and testing of new relay with feeded parameters & checking the tripping of various faults with help of relay testing kit Omicron/Megger/Equiv. make as per guidance of UPPTCL for for 132 kv mohammadi- kapraha line , 132 kv mohammadi- ajwapur line , 132 kv mohammadi- kumbhi line | 3 | Job | - | - |
| 7 | Retrofitting of numerical backup impedance protection relay P14DB/Equivalent with proper mounting and re-wiring in existing panel with proper dressing, ferruling and termination. Complete configuration and testing of each new installed relay. Testing of faults with help of relay testing kit Omicron/Megger/Equiv. make as per guidance of UPPTCL for 132 kv mohammadi- kapraha line , 132 kv mohammadi- ajwapur line , 132 kv mohammadi- kumbhi line , 132 kv lakhimpur- gulariya line & 132 kv lakhimpur- khambharkera line | 4 | Job | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.18 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.16 MB
BOQ_2078174.xls
BOQ • 0.27 MB
report.pdf
PDF • 0.19 MB
report.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .