Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹3.8 L+₹29,300 (8.31%)Rejected-Finance 37 TILAK NAGAR MATHURA 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹4.6 L+₹1.0 L (29.3%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
20 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh K K Soni AE (Civ) AGE I R and D Manali
AGE I R AND D MANALI PIN 175103 PH 01902255014
REPAIR/REPLACEMENT OF WINTER APPLIANCES AT DGRE RDC, UNDER AGE (I) R and D, MANALI
2025_MES_705235_1
AGE(I)/MNL-03/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
DGRE RDC MANALI
As per NIT and tender documents
5 documents required · 5 mandatory
₹300
AGE(I) R and D MANALI
₹10,000
Yes
1 Jul 2025
24 Apr 2025
28 May 2025
24 Apr 2025
20 May 2025
8 May 2025
Amount
Taking down geyser storage type of capacity 50 Liters and dismantling the complete accessories cleaning of inner copper tank outlet/inlet tubes reassembling, complete all as specified and directed by Engineer-in-Charge.
Taking down geyser storage type of capacity 25 Liters and dismantling the complete accessories cleaning of inner copper tank outlet/inlet tubes reassembling, complete all as specified and directed by Engineer-in-Charge.
M&L in replacement solar geysers heating element 3 KW 240 Volt, complete all as specified and directed by Engineer-in-Charge.
M&L in replacement geysers heating element 2KW 240 Volt, complete all as specified and directed by Engineer-in-Charge.
M&L in replacement geysers heating element 1.5KW 240Volt, complete all as specified and directed by Engineer-in-Charge.
M&L in replacement geysers heating element suitable for 25 litre geyser incl thermostate coil type and cutout switch 240Volt, complete all as specified and directed by Engineer-in-Charge.
M&L in replacement geysers heating element suitable for 50 litre geyser incl thermostate coil type and cutout switch 240Volt, complete all as specified and directed by Engineer-in-Charge.
Supply and fixed in replacement single pole and neutral enclosure with three plug pin and socket complete with one single pole MCB SP 20Amps 10KA 220 Volt 50Hz, complete all as specified and directed by Engineer-in-Charge.
M&L for replacement thermostat switch for geysers with temperature range 25 degree centigrade to 85 degree centigrade, complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of copper chromium plated connection 18" long with two brass adopter heavy duty ISI marked & connecting, complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of inner storage tank for geysers of 50 Liters capacity, complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of inner storage tank for geysers of 25 Liters capacity, complete all as specified and directed by Engineer-in-Charge.
M&L in repair outer cover for geyser 50 liter capacity complete incl bottom cover plate and all connected items, complete all as specified and directed by Engineer-in-Charge.
M&L in repair outer cover for geyser 25 liter capacity complete incl bottom cover plate and all connected items, complete all as specified and directed by Engineer-in-Charge.
M&L in repair glass wool for geyser of capacity 25/50 litre, complete all as specified and directed by Engineer-in-Charge.
M&L in repair for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/recessed as required 2x4.0 sq. mm 1x2.5 sq. mm earth wire, complete all as specified and directed by Engineer-in-Charge.
M&L in repair for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/recessed as required 2x6.0 sq. mm 1x4 sq. mm earth wire complete all as specified and directed.
Repair/ replacement of exhaust fan of size 230 mm incl re- winding, greasing & replacemnt of beraing, complete all as specified and directed by Engineer-in-Charge.
Repair/ replacement of exhaust fan of size 450 mm incl re- winding, greasing & replacemnt of beraing, complete all as specified and directed by Engineer-in-Charge.
M/s A.K. ENGINEERS (BID ID -3296340)
M/S SUKHMANI ENGINEERS (BID ID -3300845)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .