Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC D NO 58 22 34 9 PYDIMAMBA NILAYAM BUTCHIRAJUPALEM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.0 L+₹1.5 L (5.50%)Rejected-Finance | L2 | Rejected-Finance Hence L2 | |
| 3 | L3₹32.5 L+₹6.0 L (22.4%)Rejected-Finance | L3 | Rejected-Finance Hence L3 | |
| 4 | L4₹33.9 L+₹7.4 L (27.8%)Rejected-Finance | L4 | Rejected-Finance Hence L4 | |
| 5 | L5₹36.3 L+₹9.8 L (36.8%)Rejected-Finance | L5 | Rejected-Finance Hence L5 |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
22 Sept 2020, 12:00 pmClosed
NITIN SHARMA
GE SERVICES
REPAIR REPLACEMENT OF INTERNAL WIRING, FITTING AND FIXTURES WATER COOLERS AIR CONDITIONERS, EXTERNAL PERIMETER LIGHTING AND EXTERNAL WATER SERVICES AT NAOB V
2020_MES_371257_2
GE SERVICES TOKEN 05 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
RAMBILLI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
DGNP
₹74,000
18 Dec 2020
7 Sept 2020
23 Sept 2020
7 Sept 2020
22 Sept 2020
7 Sept 2020
7 Sept 2020 - 7 Sept 2020
Amount
INTERNAL ELECTRIFICATION
M & L for taking down the ceiling fan / Exhaust fan/cabin/wall fan/table fan/pedestal fan of any size from various building/locations and opening the same for servicing by cleaning each part with air blower/vacuum cleaner and cloths including replacement of worn out nuts, bolts, screws, washers, split pin rubber pad and oiling greasing and refixing testing complete all as specified and as directed by Engr-in-charge.
M & L for Rewiding of ceiling fan/exhaust fan/wall fan/cabin/table fan/pedestal fan of any make with super enameled copper wire of suitable existing size gauge, insulating, varnishing, heating and reassembling and refixing in buildings locations where ordered all as specified and directed by Eng-In-Charge incl testing on completion of the following type of fans.
Ceilinjg fan of size 1200mm sweep
Exhaust fan of size 300mm sweep
Exhaust fan of size 450mm sweep
Wall/cabin fan of any sweep
M & L for replacement of the following items of under Sch item No. 3 :-
Gun metal bush for ceiling fan of any make & sweep.
Ball bearing for ceiling/wall/pedestal/cabin /table Exahust fan of any make and sweep
Rotar shaft for -do-
Rubber seal for -do-
Split pin for -do-
Condenser 1.5 MFD for fans as required
Condenser 2.5 MFD for fans as required
Canopy for ceiling fan of any make and sweep
Flexible wire 23/0.0076 twin core copper conductor
Flexible wire 40/0.0076 three core
MS bolt with nut 10mm dia 75mm long
MS clamps for down rod complete with nut bolt and rubber pad for ceiling fan of any size & make
Down rod for ceiling fan made of GI pipe med gde 15mm dia of length as requred including threading, cutting, drilling including nut bolt, clamp and washer, rubber pads, cotter
Fan blades with screws, nuts and washers for ceiling fans of any make and sweep as required
M & L for complete painting of ceiling fan of any make and sweep with two coats synthetic enameled paint(spray painting) of existing colour or ordered colour on one coat of red oxide primer after scratching and making/preparation of clean and smooth surfaces by applying putty all as specified and as directed by Engr-in-charge including wiring of Sr No. 01,SM and MES No fan as directed.
All as per above item No. 23 but of exhaust fan any size.
Taking down carefully aluminium/ copper point wiring (light, fan, socket, bell or power) from surface / concealed conduit including fittings such as switches, ceiling roses, lamp holders, pendants, sockets, regulators etc but without taking down surface / concealed conduit and conduit fittings and making good disturbed surfaces complete.
Material and labour for point wiring with PVC insulated 1.5 sqmm FR multistrand copper conductor cable (Phase - Red, Neutral - Black) 1100 volts grade drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings and fixing accessories including sunken galvanized pressed steel terminal boxes of thickness 1.12 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting electrical fittings, fixtures, accessories etc and 1.0 sqmm FR multistrand copper conductor cable (Green) as continuous earth wire complete for the following :-
One light point controlled by one switch.
One fan point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board.
One socket outlet 6 amp controlled by one switch on indepdendent board.
One bell point controlled by one bell push.
One light point controlled by two, two way switches.
Material and labour for point wiring with PVC insulated 2.5 sqmm fresh multistrand copper complete conductor cable (Phase - Red, Neutral - Black) 1100 volts grade drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings and fixing accessories including sunken galvanized pressed steel terminal boxes of thickness 1.12 mm covered with 3 mm thick phenolic laminated white sheet cover and 2.5 sqmm FR multistrand copper conductor cable (Green) as continuous earth wire complete for one 16 amp socket outlet controlled by one switch on independent board.
Taking down carefully old aluminium/copper submain wiring from surface / concealed conduit without taking down conduit and conduit fittings complete.
Material and labour for submain wiring alongwith earth continuity conductor with PVC insulated FR multistrand copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed/surface reqd at site including rigid non metallic PVC conduit, medium grade, ISI marked ivory colour with all conduit accessories of following nominal sizes:-
2x2.5 sq mm + 1x2.5 sq mm (earth) in 20 mm dia conduit.
2x4 sq mm + 1x4 sq mm (earth) in 20 mm dia conduit.
2x6 sq mm + 1x6 sq mm (earth) in 25 mm dia conduit.
4x10 sq mm + 2x10 sq mm (earth) in 25 mm dia conduit.
Supplying and fixing switch piano flush button single pole one way 6 amp (duly marked for light, fan, plug etc on body of switch) complete.
Supplying and fixing switch piano flush button single pole one way 16 amp complete.
Supplying and fixing socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete.
Supplying and fixing bell push, flush type, 6 amp 240 volts complete.
Supplying and fixing switch flush type, 6 amp, single pole, two way complete.
Supplying and fixing socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete.
Supplying and fixing ceiling rose 63 x 25 mm three terminals complete.
Supplying and fixing door bell, AC, 240 volts, single pole complete.
Supplying and fixing angle holder, insulated polycabonate body with back plate complete.
Supplying and fixing hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete.
Supply and fix modular switch 1 way 6A, 1 module
Supply and fix modular switch 1 way 16A, 1 module
Supply and fix modular bell push 6A, 1 module
Supply and fix modular switch 2 way 6A, 1 module
Supply and fix modular socket, 6A-2/3 pin combined 2 module
Supply and fix modular socket, 6A/16A-2/3 pin combined 2 module
Supply and fix fan step regulator, 120 W-2 module
Supply and fix modular switch socket combination 16A,6pin, 3 module
Supply and fix surface and wall mounted LED batten 40W, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver all as specified and directed by EIC.
Supply and fix surface and wall mounted LED batten 20W with polycarbonate housing & integrated electronic driver all as specified and directed by EIC.
Supply and fix surface and wall mounted LED batten 9W with polycarbonate housing & integrated electronic driver all as specified and directed by EIC.
Supply and fixing 5W LED fitting all as specified and directed by EIC
Supply and fixing trim LED 20W fixed on wall /surface including accessories all as specified and directed by EIC
Supply and fixing 15W LED bldg security light including with GI bracket with MS clamps, nut-bolts all as specified and directed by EIC.
Supply and fixing environmental frendly, ultra modern , energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire 10W comprising of high brightness LEDs
Supply and fixing LED 20W downlights made of extruded aluminium housing and high powe LED as as light source with clear diffuser and separate electronic driver all as specified and directed by EIC.
Supply and fixing LED 36W, 2'x2' edge-lit luminaire suitable for armstrong/grid ceiling complete for low ceiling applications all as specified and directed by EIC.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete.
Supplying and fixing powder coated, CRCA steel sheet MCB distribution board (minimum thickness 1.2 mm & constructed as per IS : 8623), degree of protection IP 43 - IK 09 with metal double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required of following ratings & ways:-
SPN, 240 volts, 4 ways
SPN, 240 volts, 8 ways
SPN, 240 volts, 12 ways
TPN, 415 volts, 4 ways
Supplying and fixing as per load requirement 'C' series MCBs of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:- Note for MCBs & MCB DBs:- MCBs & MCB DBs shall be of the same make. MCB DBs shall be fixed on wall in flush pattern by cutting the wall and making good disturbed surfaces.
Single pole 6 to 32 Amp
Double pole 10 to 32 Amp
Double pole, 40 to 63 amp
Four pole 40 to 63 Amp
Supplying and fixing tripple pole and neutral, powder coated, CRCA steel sheet MCB distribution board constructed as per IS 8623 suitable for MCCB incomer upto 125 amp, 4 way, 415 volts, degree of protection IP 43 - IK- 09 with metal door, recess mounted, having 200 amp insulated tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required. Make- Legrand cat ref no 607790 or equivalent in L&T (Hager) or Moeller HPL as approved as approved.
Supplying and fixing MCCB four pole, 125 amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs etc complete. Make - Legrand cat ref no 625329 or equivalent in L&T or Moeller HPL as approved.
Supplying and fixing in renewal 20 amp, single pole and neutral, industrial type socket outlet, with 2 pole and earth, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 16/20 amp as required.
Supply and fix 63 Amps industrial wall mounted socket three phase, neutral and earth pin, 415volts, AC, 50Hz all as specified and directed by Engr-in-Charge.
Supply and fix 63 Amps industrial plug three phase, neutral and earth pin, 415volts, AC, 50Hz all as specified and directed by Engr-in-Charge.
Supplying and fixing rigid non metallic PVC conduit medium grade ISI marked ivory colour along with accessories in recess including cutting the wall and making good disturbed surfaces of following sizes:-
20 mm dia
25 mm dia
Supplying and fixing rigid non metallic PVC conduit medium grade ISI marked ivory colour along with accessories in recess including cutting the wall and making good disturbed surfaces of following sizes:-
100 mm x 100 mm x 60 mm deep.
180 mm x 100 mm x 60 mm deep.
Supply only the following items for day today complaints:-
Switch piano type 6Amp single way
Switch piano type 16Amp single way
Socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type
Socket outlet 2 in 1, 3 pin 6 & 16 amp flush type
Insulation tape industrial type
Switch bell push single way
Bell ding dong
Starter 230V for 18W/20W/36W/40W
Tube rod 36W T8 FTL
Electronic ballast suitable for FTL lamp 1x36W
LED tube fitting 22W including LED rod
LED bulk head fitting 10W
Tube rod 24W
Electronic ballast suitable for FTL lamp 2x24W
Flexible wire 1.5Sqmm 2 core
AIR CONDITIONING & REFRIGERATION Servicing/repairing of the following cooling appliances from its existing position and refixing of the same after repairing including/cleaning filter removing internal dust by using air blower and vacuum cleaner, oiling, greasing wherever required including checking / testing after completion all as specified and as directed. Note : Unserviceable/defective items which is required to be replaced shall be measured and paid separately.
Water coolers 120/80 ltr & 120/150 ltr
Split type AC 1.5 ton/2 ton capacity
Window type AC 1.5 ton/2 ton capacity
Refrigerator 165/310 ltr capacity
Deep Freezer
Finding the leakage in refrigerant system by nitrogen pressure test etc and rectifying the leakage by brazing including installation and complete testing of the following cooling appliances all as specified and directed.
Water cooler 120/80 ltr & 120/150 ltr
Split type AC 1.5 ton/2 ton capacity
Window type AC 1.5 ton/2 ton capacity
Refrigerator 165/310 ltr capacity
Deep Freezer
M&L for Charging of refrigeration gas (R-22/134a/ HCFC ete ) to existing Window AC/ Split AC /Deep Freezer/Deepe/Refrigerator of any description, any make & in any position to makeup required pressure all as directed.
M&L for replacement of the following parts/items of split/window type AC 1.5 ton / 2.0 ton capacity, water cooler 80 ltr / 150 ltr capacity, refrigerator 165 ltr / 310 ltr capacity, and desert coolers etc complete all as specified and as directed.
Starting capacitor of 80/100 mfd capacity Make: Asian/Keltern/Unistar/EPSCO/Keal
Starting capacitor of 100/120 mfd capacity Make : Asian/Keltern/Unistar/EPSCO/Keal.
Running capacitor of 4.5 MFD
Running capacitor of 30 MFD/36 MFD capacity .Make : Asian/Keltron/Unistar/EPSCO/Keal
Starting capacitor of capacity 10 MFD/20MFD. Make : Asian/Keltern/Unistar/EPSCO/Keal
Running capacitor of 4 MFD. Make : Asian/Keltron/Unistar/EPSCO/Keal
Thermostat switch for water cooler Make : Renutral/Shriram/Indfoss
Ditto all as above but AC 1.5 ton/2.0 ton capacity, Split/window type Make : Renutral/Shriram/Indfoss
Ditto all as above but for Refrigerator Make : Renutral/Shriram/Indfoss
Wiring kit for water cooler
Wiring kit for window type / split type AC
PVC air filter for split AC
PCB for Cooling Only 2/1.5 TR Split Ac.as per existing make
Brass service valve for split type A/C of size 5/8” or 3/8'' dia service valve all as approved (Make : CAM)
Refrigerator Freezer coil & freezer coil type/roll bound type complete suitable for 165 ltr. to 230 ltr. capacity
Brass Nipple 15 mm dia for inlet and out let connection of water cooler
Drain Pipe PVC flexible 1¼” dia with one end circle clip
CP brass Push cock, 15 mm. Dia.
M&L for replacement of 3 core flexible copper cable of size 40/0.0076 with thimble etc complete all as specified and as directed.
S&F in repair plug top 3, pin 5 Amp complete all as specified
S&F in repair plug top 3, pin 15 Amp complete all as specified
M&L for replacement of burnt compressor including dismantling the unserviceable burnt after disconnecting suction/discharge side copper tube bolts rubber pads and washers connecting copper tubing by welding blazing nut flaring and repairing of gas leakage if any and complete in the following cooling appliances all as specified and as directed.
Water cooler 80-150 ltr per hours cooling capacity.
Window type AC/split type AC of 1.5 ton capacity
Split type AC 2.0 ton capacity
Refrigerator 165 ltr capacity
Refrigerator 310 ltr capacity
Deep Freezer 200 to 315 ltr capacity
M&L for replacement of blower fan motor of existing size and capacity in cooling unit of split type AC capacity 1.5 TR/ 2.0 TR complete all as specified and as directed by EIC.
M&L for replacement of Condensor fan motor of existing size and capacity in outdoor unit of split type AC capacity 1.5 TR/ 2.0 TR complete all as specified and as directed by EIC.
M&L for replacement of cooper tube of size 1/4" or 3/5'' dia for cooling unit to condensing unit for split Acs all as specified and as directed by EIC.
Ditto all as per item No.149 above but of size 1/2'' or 5/8" dia
M&L for replacement of insulation for cooper tube of size 1/4" or 1/2" or 3/8" or 5/8" dia for cooling unit to condensing unit for split Acs all as specified and as directed by EIC.
M&L for writing/making SL, SM, MES Nos with black/white paint with stencil on indoor and outdoor unit of split Acs window type Acs water cooler desert coolers, stabilizers of any make and any c capacity all as specified and as directed by EIC.
M&L for replacement of metal clad socket outlet 3 pin of capacity 20 Amps 240V complete all as specified and as directed.
M&L for replacement of metal clad plug top of capacity 20 Amps, 240V complete all as specified and as directed.
M&L for replacement of float valve 15mm bore of brass with L type nipple & polythene float valve complete all as specified and as directed.
PERIMETER LIGHTINGS
Disconnecting & taking down old existing unserviceable HT/LT cable of any description and in any position i.e surface/wall or buried in ground complete all as specified and directed by Engineer-in-Charge.
Supply and laying of cables XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 3.5 core of following sizes are as under:-
XLPE UG aluminium conductor of size 3.5 core 120 Sqmm
XLPE UG aluminium conductor of size 3.5 core 70 Sqmm
XLPE UG aluminium conductor of size 3.5 core 50 Sqmm
XLPE UG aluminium conductor of size 3.5 core 35 Sqmm
XLPE UG aluminium conductor of size 4.0 core 25 Sqmm
XLPE UG aluminium conductor of size 4.0 core 16 Sqmm
Supply and laying of cables XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 volts grade cross sectional area 120 Sqmm 3 core
Excavation in trenches n. exc 1.5 mtr in depth and not exc. 1.5 mtr in wide and getting out in soft/loose soil for laying of cables all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exc 25 cm all as directed.
Removing of surplus soil n. exc. 50 M and depositing where directed at a level not exc. 1.5 M above the starting point all as directed.
M&L sand cushioning using sand dry course locally available and to be laid in layers before and after the cables are laid all as specified and directed.
PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for pole and stay complete all as specified and directed.
PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of pole etc including form work complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover, class HVP, Type 1 with peak, size 300mmx180mmx40mm all as specified and directed by Engr-in-Chage.
Supply and laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250mmx150mmx40mm all as specified and directed by Engr-in-Chage.
Taking out existing unserviceable rusted GI tubing of any size from pole/ trenches for necessary replacement all as specified and directed.
S&F 80 mm bore light grade GI tubing with necessary fitting fixed to pole or wall or in trenches for protection of electric cable all as specified and directed.
Dismantling and taking down carefully defective/non fuctional street light fittings of CFL/post top lantern etc from its existing position and refixing the same after repairing/replacement of unserviceable spare parts including re-assembling and testing complete all as specified and as directed. (Note : Spare parts/component of street light and other light fitting shall be measured and paid seprately under respective items)
Supply only new spare parts of light fittings complete all as directed of followings :-
T-5 CFL Lamp suitable for fixing on 4X24 Watt T-5 CFL fitting of rating 24 watt complete. (Make- Bajaj/Phillips/Havells)
Electronic ballast 2x24 watt suitable for T-5 CFL fittings.
Junction box made out of MS steel of size 300x300x150mm complete with 100 Amp 3 phase & one neutral rated aluminium bus bar with MS clamp of size 35x6mm MCB single 5 to 32 Amps inside box and fixed on pole with MS clamps, nut bolt and washers as specified and directed by EIC.
Supply & fixing of street light bracket (with two sets of clamp,nuts & bolts) made out of 50 mm medium grade GI pipe bend to shape and with fixing arrangement duly welded all as directed, length of pipe should not be less than 1.2 mtrs
Bi-pin holder suitable for 24W tube rod
Rigid non-metallic PVC conduit 20mm dia exclusive of boxes (junction/terminal)
Weather proof flat three core cable copper conductor cable of size 1.5Sqmm
Supply and fix pre-stressed concrete pole, 9.0 metres long, 102 mm x 172 mm at top and 102 mm x 279 mm at bottom, class 10 all as specified and dircted and Engr-in-Charge.
Material and labour lightning arresters 11000Volts, explusion type complete with all fittings, transmission class, discharge capacity 65 kilo amp all as specified and directed by Engr-in-Charge.
M&L painting of LT/HT PCC pole any type of size externaly above foundation and junction box including all MS work with one coat of off light oil bond distamper after scraping /cleaning well the existing surface complete all as specified and directed by EIC. Note : The item includied in the painting 3 Nos 30 cm wide bands blue syntthic enamel paint in alternate layer upto 1.5 mtr high above foundation and writing the pole Number all specified and directed by Engr-in-Charge
Supply, jointing and testing Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm,11000 volt grade complete with all acessories including taking down old joint Make : Birla 3m, Denson
Supply, jointing and testing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm,11000 Volts complete with all acessories including taking down old joint Make : Birla 3m, Denson
Supply, jointing and testing Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm
To find out the electric flault in HT under ground cable by fault locating kit provided by Deptt and technician to be hired by the contractor for find out the exact fault location as per safety manner and earth work upto 6m depth is also inclusive in quoted rate wherever reqd all as specified and directed by Engr-in-Charge. Note:- Technician should be well knowledge and experience in fault locating kit for using all command and controls.
All as per item No 191 above but LT under ground cable .
Disconnecting & taking down old existing unserviceable MCCB of any description and in any position complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing MCCB, 250 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 35/36 KA with adjustable load setting from 70 % to 100 % complete all as directed.
Supplying and fixing MCCB, 200 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 36 KA with adjustable load setting from 70 % to 100 % complete all as directed.
Supplying and fixing MCCB, 160 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 36 kA with adjustable load setting from 70 % to 100 % complete all as directed.
Disconnecting & taking down old existing unserviceable MCB of any description and in any position complete all as specified and directed by Engineer-in-Charge.
Supply & fixing post top lantern light fitting moulded plastic capsul with housed ballast, lamp holder baffler for glare control suitable for 1X18 Watt lamp including taking down unserviceable existing complete all as specified.
Supply and fix pin type porcelin, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade all as specified.
Material and labour for aluminium conductor, steel reinforced any size and dismantling of existing conductors all as specified and directed by Engr-in-Charge.
Material and labour for servicing of mechanically operated, mounted on insulator and steel frame gang operated device of capacity upto 400Amps with operating mechanism worked from ground level, tighting of insulaters, aluminium conductor and petrolium jelly to be used in connecting knifes and contacts and scrapping of rusted mounting structure and one coat of weather proof paint to done on structure complete all as specified and directed by Engr-in-Charge. Note:- After serviceing of GOD meggaring should completed all components and testing to be complete as per electricity rule.
Supply and Fixing energy conservation T5 lamp roadway lighting luminaire muncel gray shede finish with clear acrelic bowl & accessories 4x24 watt 240 volts 50 HZ with IP66 protection complete with T5 lamp including twincore weather proof aluminium conductor connection cable 2.5 sqmm of lenggth not less than 3.5 mtrs long all as directed .Make Bajaj Type BTSLF424MS
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected ot galvanised earth strip 25x3 mm dia by means of bolt, nuts, washers of galvanised iron or steel, earth strip protected by and including GI pipe 15mm dia bore (medium grade) and connected to main test point as directed including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:1½:3) type A-1 cover slab of size 54 x54 x 5 cm reinforced with 8mm dia TMT bars @ 150 mm C/C both ways with one handle for lifting, made out of 8mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20mm bore GI pipe (medium grade) for watering, charcoal and salt in alternate layers, including necessary excavation and earth work in any type of soil complete all as shown on electrical plate No 3 of SSR Part-I and testing complete all as specified and as directed.
Material and labour for fixing 4mm dia GI wire on electric pole/ connected to distribution board all as specified and directed by Engr-in-Charge
DISTRIBUTION TRANSFORMERS
Dehydration of transformer oil using on line filteration plant to eliminate foreign particles and to improve dielectric strength upto 60 KV at 4mm electrode gap and to bring acidity withing permissible limits all as specified and directed by Engr-in-charge. Note:- Dehydration machine to be provided at site for progessing of work.
Supply and filling new transformer oil brought in sealed barrel having strength of 60 KV at 4 mm gap all as specified and directed by Engr-in-Charge. Make : Power oil or equivalent.
Disconnecting transformer , opening the top cover, draining out transformer oil to clean barrel for reuse and carrying out the following works for undermentioned capacity of transformers :- (a) Dismantling of all attachment viz breather assy, conservator, oil temperature gauge, HT/LT bushing etc and keeping aside for re-use / replacement. (b) Cleaning of complete transformer tank oil fins, removing of sludge’s and making the inside surface of tank dry by blowing of hot air as directed by the Engineer-in-charge. (c) Replacement of unserviceale/defective parts of transformer (Except rewinding) all as directed by Eng-in-charge. Note: Spare parts shall be measured and paid separately under relevant item of Sch’A’ here-in-after.
For 63 to 100 KVA Transformer
For 200KVA Transformer
Disconnection of both HT and LT connection from cable end box, taking down the disconnected transformer(Outdoor type) from platform,and transportation of unserviceable transformer complete unit to workshop including loading/unloading of capacity 200KVA 11/0.433 KV.
(a) Disconnecting and taking down faulty / defective copper wound transformer , opening the top cover, draining out unserviceable insulation oil and carrying out the following work :- (b) Rewinding of HT / LT leg coil complete using copper wire of appropriate gauge, size and turn as existing with double paper coated insulation including all requisite insulating materials like packing sleeves, separator, tapes etc. as specified and existing, heating, varnishing the core and winding assembly after framing up top and bottom steel structure of transformer all as specified and directed. ( HT / LT Leg coils copper wound shall be measured and paid separately under relevant item of Sch ‘A’ here-in-after). (c) Replacement of all insulating materials other than incorporated for rewinding of LT/HT coils as existing . (d) Fixing of HT porcelain bushing with studs, nuts, washers 3 Nos and LT porcelain bushing with studs, nuts and washers 4 Nos and connection with primary and secondary winding main terminals all as directed and specified. ( HT/LT bush with stud, nuts, washers shall be measured and paid separately under relevant item of Sch’A’ here-in-after) (e) Fixing only existing serviceable accessories as obtained from Ser No 3(a) after proper cleaning, minor repair etc all as required and directed (f) Replacement of all gasket materials in top cover, HT, LT bushing using rubberized gasket sheet 4.0/6.0 mm thick duly pasted with gasket cement. (g) Replacement of unserviceable bolts, fixing of existing serviceable bolts, nuts, washers of different size and tightening properly. (h) Repositioning of core and winding assembly inside the tank, assembling the complete unit and filling of transformer oil and subsequent testing complete all as directed. (j) Shifting the transformer to its original side including reconnection of HT/LT cables and including subsequent testing complete all as directed.
All as described in Sch ‘A’ item No. 212 here-in-before but of capacity 63 KVA 11/0.433 KV but using copper winding wire/strips of appropriate gauge/size for rewinding. (HT/LT Leg coils (copper wound) shall be measured and paid separately under relevant item of Sch ‘A’ here-in-after).
Supply of HT Porcelain Bushing with Brass stud, nuts and washers for transformer cap 63KVA 11/0.433 KV for incorporation against Sch’A’ item No 3&4 here-in-before.
Supply of LT Porcelain Bushing with Brass stud, nuts and washers (Set of 04) for transformer cap 63KVA 11/0.433 KV for incorporation against Sch’A’ item No 5
Supply only for fixing in repair of LT Porcelain Bushing with Brass stud, nuts and washers for transformer cap 200 KVA ,11/0.433 KV
Supply only for fixing in repair of ruber insersion sheet 4mm thick for top cover and other joints for transformer capacity up to 200 KVA, 11/0.433 KV
M&L for painting of transformer complete unit outside surface using 1st Quality synthetic enamel paintone coats over existng paint after necessary cleaning for transformer of capacity up to 250 KVA.
Supply only for fixing in repair of air breather for transformer complete for transformer of capacity 63KVA to 200 KVA.
Supply & fixing of Silica gel in granular form fo transformer air breather all as directed
M&L for extension of GI Strip of size 32 x 6 mm for transformer neutral and body earthing with suitable size nuts, bolts and washers complete.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections incl nuts, bolts, washers and incl welding, bending (cold or hot), drilling holes, for bolts any shape or size as indicated or directed and inclusive of one primer coat of red oxide and two coats of aluminium paint complete all as specified.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected ot galvanised iron strip of size 32 x 6mm earth lead by means of bolt, nuts, washers of galvanised iron or steel, earth strip protected by and including GI pipe 40mm dia bore (light grade) and connected to main test point as directed including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:1½:3) type A-1 cover slab of size 54 x54 x 5 cm reinforced with 8mm dia TMT bars @ 150 mm C/C both ways with one handle for lifting, made out of 8mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20mm bore GI pipe (medium grade) for watering, charcoal and salt in alternate layers, including necessary excavation and earth work in any type of soil complete all as shown on electrical plate No 3 of SSR Part-I and testing complete all as specified and as directed.
DG Sets
Servicing of DG set capacity 160kVA make cummins and taking out the defective/unserviceable parts and re-assembling the same after repair/replaced and testing complete all as specified and directed. (Note : U/S spare parts shall be measured and paid separately as supply only here in after).
Diesel filter
Oil filter
Oil pressure gauge
Hose pipe set with clamps & clips complete
Ampere meter
Volt meter
Air filter
Fan belt
Repairing of self starter by replacement & bearing, field coil, GM bushes varnishing & testing as directed.
Repair & over hauling of injector Nozzle including calibration 110-125 KVA DG set in authorised factory and testing by pressure machine on required pressure as specified & directed.
All as per item No. 225 above but DG set 10 KVA Make :- Kirlosker
Diesel filter
Oil filter
Hose pipe set with clamps & clips complete
Air filter
Fan belt
Ampere meter
Volt meter
Repair & over hauling of FIP including replacement of defective parts as required including calibration in authorised factory/dealers & testing complete all as directed.
Repairing of dynamo including replacement of armature field coil, GM bushes, heating, varnishing, testing complete all as directed.
Taking out carefully unserviceable fuel injector pump assembly of 160kVA DG set of 1500 RPM Make:- CUMMINS/KIRLOSKAR/KEC/CROMTON, cleaning/ oiling/servicing fuel injector pump assembly , recalibration of Fuel Injector Pump after replacing unserviceable nozzles/Bearing bush with roller/ Delivery valve with washer and spring/Roller Bearing. /Bearing end plate etc.,re-assembling and fixing the same in position and testing the Fuel Injector Pump assembly all as specified and directed by Engineer-in-Charge.
Repairing and reconditioning of battery 180 AH 25 plates by replacement of plate, separator including battery terminal complete all as specified and directed by EIC.
Supply and filling lubrication oil SAE-40 ( 20 W- 40 grade) of Make SERVO OF IOC/HINDUSTAN PETROLEUM/BPCL/ CASTROL) as approved by GE.
Replacement of asbestos ropes with new asbestos rope of existing size of exhaust pipe 160 kVA D.G. Set.
Replacement of asbestos ropes with new asbestos rope of existing size of exhaust pipe 7.5 to 10 KVA D.G. Set.
Dismantling of oil sump and decanning old engine oil from DG set upto 7.5 kVA to 10 kVA capacity and cleaning the oil sump chamber by removing settled particals, sludge etc for pressure vacume including rectify the leakage by welding including refixing the same by replacement new nuts, bolts clamps all as specified and directed.
Dismantling of oil sump and decanning old engine oil from DG set upto 160 kVA capacity and cleaning the oil sump chamber by removing settled particals, sludge etc for pressure vacume including rectify the leakage by welding including refixing the same by replacement new nuts, bolts clamps all as specified and directed.
Disconnecting, and taking out carefully old unserviceable rectifier of any make and capacity,suppling and fixing new rectifier of existing make suitable for 7.5 kVA to 160 kVA DG set complete all as specified and directed.
EXTERNAL WATER SUPPLY
Taking out defective submersible openwell pump set of capacity 7.5HP from open well/UG sump for repair by lifting GI tubing of size 65 mm from up to 40feet to 10 to 15feet depth after disconnecting electrical and pipe line connection, complete by means of chain pully block or other T & P, transporting to workshop including repair/replacement of worn out parts, servicing and overhauling complete with oilling/greasing, lubricating the parts and reassembling and painting of submersible pumpset with motor with one coat of synthetic enamel paint after clearing and scrubbling and shifting back to openwell/ UG Sump, lowering commissioning and testing on full load complete all as specified and directed by Engineer-in-charge. Note:- (i) The rate quoted for this item shall includes labour charge only for maint repair and replacement of defective / UNSV spares / accessories. Spares are to measured and paid separately under subsequent items. (ii) Cost of other minor items/spares such as nut, bolts washers, gaskets, paints etc which are not covered under Sch 'A' but required for effective functioning of the plant shall be deemed to included in this item.
Supply only following items / parts for 7.5HP submersible openwell pump set.
(a) Thrust bearing
(b) Gun metal bearing bush.
(c) Stainless steel studs and nuts
(d) Impeller
(e) Seal
(f) Impeller key
(g) Rotor sleeve
Dismantling the motor of submersible openwell pumpset of capacity 7.5HP, removing the existing burnt out winding and rewinding with PVC copper winding wire of existing gauge and weight including replacement of all insulation material, "O" rings and filling of cooling oil with oil seal and terminal lead for AC, 3Phase, 415volts grade and other petty items required for making motor functional and motor reassembling and testing complete all as directed by Engineer-in-Charge
Desilting of open /shallow well dia of 25 feet and 25 feet depth at Rambilli premises by bailling out of water from the well through pump set, removing the silt (mud/sand etc) from the floor of the wells and deposting not exceeding 50 metre, cleaning the inside vertical surface of the wells with wire brushes including removing the large growth and removing the large floating of suldge on the water completely including one coat of wash of inner surfaces all as specified and directed.
Taking up of unserviceable / rusted tubing and connections of 15mm bore from excavated trench / walls / floors / ceiling etc complete all as directed.
All as per item No. 266 herein before but for 20 mm bore pipe
All as per item No. 266herein before but for 25 mm bore pipe
All as per item No. 266herein before but for 40 mm bore pipe
All as per item No. 266 herein before but for 50 mm bore pipe
Supply and laying GI tubing of 15 mm bore galvanized medium grade of any length including all fittings such as bend, elbow, tee and union on floors/ walls/ceilings complete
All as per item No. 271 herein before but for 20 mm bore pipe
All as per item No. 271 herein before but for 25 mm bore pipe
All as per item No. 271 herein before but for 40 mm bore pipe
All as per item No. 271 herein before but for 50 mm bore pipe
Supply and laying GI tubing of 15 mm bore galvanized medium grade of any length including all fittings such as bend, elbow, tee and union in trenches complete
All as per item No. 276 herein before but for 20 mm bore pipe
All as per item No. 276 herein before but for 25 mm bore pipe
All as per item No. 276 herein before but for 40 mm bore pipe
All as per item No. 276 herein before but for 50 mm bore pipe
Cutting the existing GI steel tubing 25mm bore and screwing the cut ends (or length) screw on pipe to form connector in trenches, floors or on walls and ceiling for alterations or addition and rejointing including connecting up with GI union complete all as specified
All as per item No. 281 above but for 40mm bore pipe
Replacement of unserviceable gun metal globe or gate valve of brass heavy duty ISI marked with iron wheel head, butterfly handle screwed both ends for iron pipe of 15 mm bore complete in place of all as directed fixed in wall and ground.
All as per item No. 283 here in before but for iron pipe of 20mm bore
All as per item No. 283 here in before but for iron pipe of 25mm bore
Cutting the existing damaged 50mm dia GI/HDPE pipe line in position supply and inserting by reducing the dia of pipe tee/elbow testing including necessary earth work in sludgy soil, dewatering and refilling the same in layers complete all as specified and directed by Engr-in-charge
M & L for construction of brick masonary (230 mm thick wall) valve pipt of size 450 x 450 x700mm inner dimension including necessary earth work , PCC 1:4 8, 75 mm thick Type D-2 using 40 mm graded stone aggregate as in foundation , brick wall build in CM 1:6, rendering 15 mm thick with CM 1: 6 externally upto 15 CM below GL and CM 1:4 internally and providing MS Sheet cover 3.15 mm thick welded with hinges including necessary locking arrangement and complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level )with top edge of earth plate not less than 1.5 mtr below GL connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part I connecting to earth points and testing on completion with and including 15 mm bore light grade GI protection pipe (7.5 mtr long) for earth lead including P C C 1:2:4 type B1 chamber pit with pre cast R C C1:2:4 type B1 cover slab40 mm thick reinforced with 6 mm dia MS bar C/C 100 mm both ways with lifting hook made out of 6 mm dia MS rod, watering arrangement with GI light grade 20 mm bore watering pipe with funnel, wiremesh, common salt, charcoal filling necessary excavation in any type of soil complete all as specified.
Replacement of submersible PVC insulated cable of 650/1100 volts grade 3 core 6sqmm with flexible copper conductor water resistant quality ISI marked in replacement.
Replacement of PVC water tank of 1000 Ltrs cap, rotational moulded polyethylene water storage tank (cylindrical vertica with closed top) hoisted and fixed in position including dismatling of existing tank all as specified and directed by Engr-in-Charge.
Replacement of HDPE pipe 50mm bore of pressure rating 6kgf/sqcm laid in trenches including connected accessories all as specified and directed by Engr-in-Charge.
All as per item No. 291 herein before but for 32 mm bore pipe
All as per item No. 291 herein before but for 25 mm bore pipe
Replacement of ball brass valves 25mm dia, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified and directed by Engr-in-Charge.
All as per item No. 294 herein before but for 20 mm bore pipe
Supply and fixing PVC connection 15mm dia 450mm long including clamps and nuts all as specified.
JAI ENTERPRISES
VARADHI ENTERPRISES
VINAYAK BUILDTECHS
R AND A ASSOCIATES ENGINEERS CONTRACTORS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .