Providing, Installation, testing and commissioning of 250 KVA Voltage stabilizer and Submersible Pump Set 2000 GPH 100 MH at Filtration Plant Chatyar Khadala Base,
2019_PHE_89461_1
e-NIT PHE/MDR/40 of 2019-20
Open Tender
Miscellaneous Works
Item Rate
10 days
RAJOURI
Please refer Tender documents.
3 documents required · 3 mandatory
₹250
Yes
revenue head 0215 water sanitation
Yes
21 Jan 2020
31 Dec 2019
9 Jan 2020
31 Dec 2019
8 Jan 2020
3 Jan 2020
Amount
Fabrication/ Manufacturing of 250 KVA Voltage Stabilizer. Oil cooled unbalance Type 415Volt, Complete with Transformer Oil in Copper windings capable of operating on unbalanced Voltage. Capacity : 250KVA Phase : 03 Make : Confirming to relevant ISO With all latest amendments Input voltage : (160-380 ) volt Out put voltage : 415 volts +/- 1% Type : Manually operated Correction Rate : 12 to 35 V/sec Regulation : +/- 1% Frequency : 48 to 52 Hz Cooling Method : Oil Cooled Efficiency : 95% High & Low cut off : Installed with standard Capacity By pass change over Switch : Yes MCCB : Heavy Duty Single phase preventer : Yes Material of Construction : The Core should be first quality ( CRGO) Silicon Steel core : Conducting conductor should be off 99.95% of Electrolytic Copper MS Steel thickness of container 14/16 SWG Transformer Oil to be used shall be of best quality Conforming of IS 335 with latest amendments. Voltage stabilizer shall be mounted on 02 pairs of H/D MS wheels for making shifting/ fixing easy. : Voltmeter/Ampere meter Good quality ISI make of Required Specification : Toggle Switch 03 No for input/output reading of each face : Rotary Switches Of suitable Amp range each of 08steps 01 for Line voltage 02 for step down voltage 05 for step up voltage Heavy duty terminal block for input/output terminal Paint : Painting shall be enamelled steel grey / Green Colour
Installation, testing & commissioning of 250 KVA voltage stabilizers by way of carriage/ shifting of stabilizer from stacking place to site of work on MT and HL. P/F of Copper cable of standard ISI make(as per site condition) for making connections from main switch to Voltage stabilizer for all the three phases in three leads with neutral & then from stabilizer to buss bar fuse system with proper thimbling duly crimpled by using crimpling tool & proper insulation. Conducting of whole electric circuit with the help of conduit pipes, PVC flexible pipes, bends etc. Filling of transformer oil up to required level after heat treatment/dehydration to make it moisture free. Job includes cost of material and Fitting charges.
Providing, of multi stage submersible pump set 2000 GPH x 100MH (Head Range +10-25), coupled with suitable motor. The recommended make of Pump should be Kirloskar/ KSB/ LUBI along with recommended make of motor. The pumping Machinery should confirm relevant ISO with all latest amendments. The equipment shall also be accompanied with test certificates and performance curves.
Installation, testing and commissioning of Submersible Pump Set 2000 GPH X 100 MH at pumping station Chtyar Khadala Base, along with allied works by way of fabrication of 50mm dia GI pipe nipples 10 feet and 20feet long welded with MS flanges-50mm dia at both ends-10nos & 6nos respectively , for making delivery of the pump. Fabrication of GI pipe nipple with threads at one end & MS flange at other end & fastening the threaded end of nipple with the delivery of pump. Fabrication of gantry by way of making of base frame of MS channel and plates of required size. Grouting the base frame at bore well site, fab/erection of G.I. pipe nipples at both ends of the base frame, welding of pipe nipple of required size at top. Fabrication of MS clamps 50mm dia. - 02 sets for holding submersible pump & nipples. Providing of chain pulley block heavy duty of capacity 02 ton -01 no. Providing /Fitting of 6 mm square three core sub cable for making of electrical connection from motor to control panel with proper thimbling & insulation. Coupling of pump motor with the help of coupling pulley. Lowering of pump motor set along with GI pipe nipples and submersible cable into the Bore well with the help of chain pulley block, ropes & skilled/unskilled labours. Providing/Fitting of MS bends 50mm dia. with MS flanges. Providing/Fitting of 50mm dia sluice valve & check valve 50mm dia-01no each with MS flanges, nut/bolts & washers, and interconnecting with the raising main with all allied welding work. Providing /Fitting of 10 HP automatic submersible control panel having protection devices -01 no. Providing/Fitting of nut/bolts, washers, tapes & sundry items required at site .Complete job includes cost of material, labour charges & carriage charge.
Testing and commissioning of submersible pump motor set all other allied electromechanical works. Checking of all electrical connections, tapping and tightening all other connections. Plugging of leaking joints if any by way of welding, replacement of gaskets and tightening of nuts and bolts. Testing the machinery on full load. Complete job.
PERFECT ELECTRICAL WORKS
BEE AAR ENTERPRISES
NATIONAL ELECTRO-MECH COMPANY
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .