Executive Engineer (Elect)/KBZ
OFFICE OF THE EX. ENGINEER (ELECT)-IV/KBZ TOURIST CAMP SITE, J.L. NEHRU MARG, DELHI-02
Supply installation Testing and Commissioning of 1 No. of Boom Barrier at main entrance L Block (L-24) Kirti Nagar under Karol Bagh Zone
2025_MCD_256161_1
NIT No 29/EEE/KBZ/MCD/2025-26
Open Tender
Electrical Works
Percentage
45 days
Karol Bagh Zone
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
₹5,900
11 Dec 2025
19 Nov 2025
25 Nov 2025
19 Nov 2025
25 Nov 2025
19 Nov 2025
Supply, installation, Testing and Commissioning of RFID/Fastag Based Automatic Boom Barrier complete in all respects (Civil/Electrical) A) Premium Quality Electromechanical Swing type Automatic Barriegate/ Boom Barrier: Boom of rectangular/oval/hexagonal shape made up of aluminium having minimum size of 100*40 mm, Telescopic Arm length - 3 to 6 meter, Microprocessor Based Controller, Noiseless operation with auto Cooling system with Reflecting LED light & Tapes in Length, Rated Power/Torque/Frequency:- 100-150W/ 50-60Kg, 50-100 Nm, 50/60Hz, CE/UL/BIS certified including following accessories as follows: a)PC Safety Anti accident Device, b)Dual Channel Loop Control Detector including Induction Coil for Auto close operation, c) 3 Way Opening switch controller (Push Button), d) Civil foundation works (PCC)(foundation of minimum size 450mmLx450mm Wx350mm D (100 mm above ground level)(NS using M15 grade concrete)) , e) The name of the MP/MLA/Councillor etc is to be written with their constituency with enamel paint of suitable size B) RFID Reader and Controller may be integrated as Per form factor of the system provided by the vendor. Tag Read Range : 15-20 meter ,Tag Write Range : 0-6 mtr Freq Range: Global 902~928 MHZ and 865~868 MHZ, Capability: Simultaneous multiple tag read capability Antenna : 12 dBi built in and Linear Polarized Reading Clue : Buzzer/LED/ Suitable indication Frequency Hopping : FHSS Software Programmable or Fixed, Power Output : 0-30 dBm or more, Working Mode: Auto running, interactive,Trigger Activating Mode Interface/Ports : RS 485/ RS 232/ Wiegand/TCP IP/RJ45 Protocols : ISO certified Working Temp : -20°C to +80°C, Humidity : Upto 95% or better,Regulatory: Compliance with CE & FCC & ROHS & MSME & BIS, Power Consumption : 1-2 Watt, Protection Grade: IP65, Mounting and casing : All weather proof Input Power : 100-240V, DC +9V adapter (1Set as 01 for Entry & 01 for Exit Total 02 Nos.) C) Single door controller for 02 Reader having the capability/ capacity to verify the vehicle tag in almost real time and should be able to maintain the records/ data of at least 5000 Vehicles. Controller should have the capability to integrate control boom barrier. Communication ports : RS485/TCPIP, Working Temperature : -20°C to +80°C, Operating Humidity : upto 95% or better, Capacity : upto 10,000 card data or more, Visual Indicator : LED / Indication for power, communication, etc. Power : 220-240 V AC / DC power with adapter Certifications : CE, FCC, ROHS (02 Nos.) D) RFID Windshield Tag workable in dense fog and heavy rain or bad weather Dimensions : 100x30mm +-5%, 110x40mm (+-5%) (Antenna Size) Operation Frequency : 860-960 Mhz Protocol : ISO certified CHIP, Memory: 32-bit, TID – 64-bit ,Unique TID – 96-bit EPC Memory, Memory : Blockable & Password protected Adhesive Application Integrated Circuit (Qty. 350 Nos.) E) SITC of Mounting pole for RFID Reader with Sufficient height (02 Nos.) F) Fastag Integration one time exclusive of cloud charges, Monthly Internet Charges ( Excluding 3 core x 1.5 sqmm cable)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal/ coke and salt as required).
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing 6A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
P/F of hot press sheet moulded compounded (SMC ) fire retardant ( Temp. resistance up to 200C) Ip -55 weather proof pole box of inner dimension 200X160X98mm complete with suitable arrangement for fixing of 2 nos. of 6 to 32 Amp. Single pole MCB & 63 a double pole isolator ( MCB and isolator excluded) with nutral link duly shorting on DIN channel with 2 nos of clamp wit ss back plate of suitable size with Danger Monograme & SDMC property printed on the cover ETC as required.
Providing and fixing name board made of MS Sheet 90x60 cm, 1mm thick with frame of MS angle 50x50x6mm, two diagonal braces at the back othe sheet of MS flat 40x6mm, total height of the board above ground level 2.40m, length of legs below ground 0.30 embedded in CC block 1:2:4 ( 1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) 30x30x45cm including excavation and removal of surplus earth with in 50m lead, applying priming coat of approval steel primar, painting with synthetic enamel paint of approved quality and lettering with enamel paint of approved colour (one side) as per drawing/direction Engineer-in-Charge
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
Tendernotice_2.pdf
PDF • 1.03 MB
Conditionravinder.pdf
Tender Documents • 0.41 MB
BOQ_295282.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .