Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹74.6 L+₹8.2 L (12.4%)Rejected-AOC DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | L2 | Rejected-AOC L2 | |
| 3 | L3₹75.1 L+₹8.7 L (13.2%)Rejected-AOC JAGAHARIMURA AGARTALA WEST TRIPURA | AGARTALA | WEST TRIPURA | TRIPURA | L3 | Rejected-AOC L3 | |
| 4 | L4₹76.7 L+₹10.3 L (15.5%)Rejected-AOC JATANBARI KARBOK GOMATI TRIPURA | L4 | Rejected-AOC L4 |
Tender Value
₹68.0 L
EMD Value
₹1.4 L
Closing Date
2 Jan 2023, 2:00 pmClosed
DGM, ED-II, Bordowali
ED-II, Bordowali, Agartala
SHIFTING OF ELECTRICAL UTILITY and CONSTRUCTION OF VERTICAL FORMATION 33kV and 11KV COMPOSITE OVER HEAD LINE ON 11.0Mtr LONG STEEL TUBELAR POLE FROM SIDDHI ASHRAM TO BYPASS ROAD INCONNECTION WITH WIDENING OF ROAD BY PWD UNDER ELECTRICAL SUB-DIVIS
2022_POWER_35496_1
DGM/ED-II/TSECL/2022-23/19, dt. 19.12.2022
Open Tender
Electrical Works
Item Rate
180 days
Under ESD-III, Bordowali.
Please refer Tender documents.
8 documents required · 8 mandatory
₹5,900
Yes
TSECL Settlement Centralised Account
₹1.4 L
Yes
O/O the AGM, EC-I, Agartala
17 Mar 2023
20 Dec 2022
3 Jan 2023
21 Dec 2022
2 Jan 2023
27 Dec 2022
21 Dec 2022 - 24 Dec 2022
26 Dec 2022
Amount
(Supply & Erection)
Supply of 11.0Mtr Long Steel Tubelar Pole
Supply of Saty Set Complete
Supply of Stay Insulator(11KV)
Supply of Stay Standard Wire
Supply of 0.30Mtr. Long SP Top Line Cross-arm (made of 100x50x50x6mm Channel)
Supply of fabricated 1.50Mtr. Long SP Bottom Line Cross-arm (made of 100x50x50x6mm Channel)
Supply of fabricated 1.80Mtr. Long SP Guard Cross-arm (made of 65x65x6mm Angle)
Supply of fabricated fabricated 1.80Mtr. Long DP Top Line Cross-arm (made of 100x50x50x6mm Channel)
Supply of fabricatedof 2.20Mtr. Long DP Bottom Line Cross-arm (made of 100x50x50x6mm Channel)
Supply of fabricated 2.50Mtr. Long DP Guard Cross-arm (made of 65x65x6mm Angle)
Supply of fabricated 1.80Mtr. Long DP horizontal belt Cross-arm (made of 65x65x6mm Angle)
Supply of fabricated 2.50Mtr. Long DP diagonal belt Cross-arm (made of 65x65x6mm Angle)
Supply of fabricated 5-Wire LT C-Cross arm, made of 50x50x6mm MS Angle.
Supply of fabricated1.10Mtr. Long SP Line Cross-arm (made of 75x40x40x6mm Channel)
Supply of fabricated 1.40Mtr. Long SP Guard Cross-arm (made of 65x65x6mm Angle)
Supply of fabricated 1.65Mtr. Long Cross-arm (made of 50x50x6mm Angle) for Cross-arm belt.
Supply of fabricated 1.50Mtr. Long Cross-arm (made of 50x50x6mm Angle) for Cross-arm belt.
Supply of fabricated 1.2Mtr. Long DP Line Cross-arm (made of 75x40x40x6mm Channel)
Supply of 11KV Disc Insulator(Polymeric), 45 KN.
Supply of 11KV Disc Insulator,75 KN
Supply of 11KV Disc Fittings(B&S, 2U Bolt)
Supply of 11KV Disc Fittings(B&S, 3U Bolt)
Supply of 11KV Polimeric Composite Pin Insulator
Supply of 33KV Polimeric Composite Pin Insulator
Supply of LT Shackle Insulator
Supply of Straps with Nuts&Bolt
Supply of ACSR Conductor (6/1/3.35mm), RABBIT
Supply of ACSR Conductor (6/7/4.72+1.57mm) (DOG)
Supply of GI Wire (8SWG)
Supply of 120 sqmm . 3-Core, 11KV XLPE Power Cable
Supply of end termination jointing kit for 120 sqmm . 3-Core, 11KV XLPE Power Cable
Supply of 4sqmm PVC cable
Supply of MS Clamp for Stay Set
Supply of MS Clamp for Cross-Arm
Supply of MS Nut & Bolts (Assorted size)
Supply of LT 1.1KV Grade, 3.5Core, 120-240sqmm LT XLPE Power Cable End termination Kits
Supply of 100mm GI Pipe(Medium Class
Supply of 110mm dia HDPE Pipe
Dismantling of (Single Conductor) ACSR 6/1/2.59mm dia 'WEASEL' including Coiling etc. Complete as required.
Dismantling of 1 KM (Single Conductor) ACSR 6/7/4.72/1.57 mm dia 'DOG' including coiling etc. Complete as required.
Dismantling of shackle insulator of size 75mm x 90mm /100mm x 15mm with straps & bolts/U clamp on pole
Dismantling of 11 KV Pin insulator along with Pin.
Dismantling of 33KV pin insulator along with Pin.
Dismantling of 11 KV Single Disc insulator set along with necessary fittings.
Dismantling of Disc insulator Set for 33KV line along with necessary fittings
Dismantling of M.S.Angle Cross-Arm bracket of 2/3/4 wire ,upto 11 OOMtr. Long of 50 x 50 x6mm/ 65 x65 x 6 mm
Dismantling of "C" type bracket for LT 3-wireof 50 x 50 x6mm/ 65 x65 x 6 mm
Dismantling of "C" type bracket for LT 5-wire of 50 x 50 x6mm/ 65 x65 x 6 mm
Dismantlling of Angle Cross-Arm, 1.0 to 1.6 Mtr. Long 65X65X6mm
Dismantlling of MS channel Cross-Arm,0.3 to 1.6 mtr long 75X40X40X6mm
Dismantlling of MS channel Cross-Arm Cross-Arm, 2.2 to 2.8 mtr long 75X40X40X6mm
Dismantlling of MS channel Cross-Arm Cross-Arm, 0.6 to 2.8 mtr long 100X50X50X6mm
Dismantlling of MS channel 'V' Cross-Arm65X65x 6 mm MS angle/75X40X40X6mm MS channel
Dismantling of M.S.Channel Cross-Arm exceeding 2.8 Mtr. Long 100 x50 x 50 x 6 mm
Dismantling of 7.5mtrs & 8Mtr. length of P.C.C POLE at any kind of soil , including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect
Dismantling of 9.0mtrs length of P.C.C POLE at any kind of soil including excavation of earth, refilling the pit with with soil upto the ground level, ramming and making complete in all respect
Dismantling of 7.0mtrs,8mtrs & 9mtrs length of Steel Tubular POLE at any kind of soil . Including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in the ground level, ramming and making complete in all respect
Dismantling of 10mtrs, 11 mtrs & 12mtrs length of Steel Tubular POLE at any kind of soil including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect.
Dismantling of Rig Pole/Joist Pole/Rail Pole upto the length of 13mtr. at any kind of soil . Including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect.
Carriage of 7.5mtrs/ 8.0mtrs length of P.C.C Poles by Mechanical Transport from Site to Workshop Vis-a-vis, including loading, unloading and stacking as required, a) Upto the lead range of 25KM, i) For maximum 5 (five) poles
Carriage of 9.0mtrs length of P.C.C Poles by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis,including loading, unloading and stacking as, a) Upto the lead range 25KM, i) For maximum 4 (four) poles
Carriage of. of 7.5mtrs /8.0mtrs / 9.0mtrs length of Steel Tubular Poles by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required, a) Upto the lead range 25 KM , i) For maximum 8 (eight) poles
Carriage of 1 O.O mtrs/ 11.0mtrs I 12.0 mtrs length of Steel Tubular Poles by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required, a) Upto the lead range 25 KM, i) For maximum 6 (six) poles
Carriage of Rig pole/ Joist Pole I Rail Pole upto the length of 12.0mtrs by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required, a) Upto the lead range 25KM (For max. five poles)
Carriage of materials such as Cable.AAC, AAAC, ACSR, G.l.Wire,Cross-Arm,Stay Set.Insulators etc., by Mechanical Transport from the Electrical SubDivisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required, upto the lead of 25KM & 50KM, a) Upto the lead range 25KM
Erection of 10 mtrs, 11 mtrs & 12mtrs length of Steel Tubular POLE at any kind of soil upto a depth of 1/6 th of pole height, including excavation of earth refilling the pit with soil upto the ground level,ramming and making complete in all respect.
Erection of Stay set direct in earth complete with 19mm x 1800 mm long stay rod, anchor plate of size 300 x 300 x 8 mm ,thimble, turn buckle, 7/3.15 mm dia G.I Standed stay wire and stain insulator etc. with Supply of M.S.Clamp,Nuts & Bolts etc. as required. and making complete in all respect
0.30Mtr. Long SP Top Line Cross-arm (made of 100x50x50x6mm Channel)
1.50Mtr. Long SP Bottom Line Cross-arm (made of 100x50x50x6mm Channel)
1.80Mtr. Long SP Guard Cross-arm (made of 65x65x6mm Angle)
1.80Mtr. Long DP Top Line Cross-arm (made of 100x50x50x6mm Channel)
2.20Mtr. Long DP Bottom Line Cross-arm (made of 100x50x50x6mm Channel)
2.50Mtr. Long DP Guard Cross-arm (made of 65x65x6mm Angle)
Erection of 1.10Mtr. Long SP Line Cross-arm (made of 75x40x40x6mm Channel)
Erection of 1.40Mtr. Long SP Guard Cross-arm (made of 65x65x6mm Angle)
Erection of 1.65Mtr. Long Cross-arm (made of 50x50x6mm Angle) for Cross-arm belt.
Erection of 1.50Mtr. Long Cross-arm (made of 50x50x6mm Angle) for Cross-arm belt.
Erection of 1.2Mtr. Long DP Line Cross-arm (made of 75x40x40x6mm Channel)
Erection of 1.40Mtr. Long DP Guard Cross-arm (made of 65x65x6mm Angle)
Erection of 1.80Mtr. Long DP horizontal belt Cross-arm (made of 65x65x6mm Angle)
Erection of 2.50Mtr. Long DP diagonal belt Cross-arm (made of 65x65x6mm Angle)
Erection of 5-Wire LT C-Cross arm, made of 50x50x6mm MS Angle.
Erection of 33KV pin insulator along with Pin
Erection of 11 KV Pin insulator along with Pin.
Erection of Disc insulator Set for 33KV line along with necessary fittings.
Erection of 11 KV Single Disc insulator set along with necessary fittings
Erection of shackle insulator of size 75mm x 90mm /100mm X 15mm with straps & bolts/ U-clamp on poles (Excluding the cost of straps / U- clamp, Nuts & bolts).
Laying & Stringing of 1 KM (Single Conductor) ACSR 6/1/3.35 mm dia 'RABBIT' including hoisting & binding etc. Complete as required.
Laying & Stringing of 1 KM (Single Conductor) ACSR 6/7/4. 72/1. 57 mm dia 'DOG' including hoisting & binding etc. Complete as required.
Laying & strining of 1 KM (Single Conductor) , 10/8SWG GI wire including hoisting & binding etc. Complete as required.
Erection of 11 KV protective Guarding by GI wire 8 SWG as per technical speciñcation. across road/ River IT elecom line etc. in horizonta formation complete .
Erection of 33KV protective Guarding by GI wire 8 SWG as per technical speciñcation. across road/ River/ Telecom line etc. in horizonta formation complete
Erection of protective Guarding/ Cross lacing for 415/240Volt line BY GI wire 98/10SWG as per technical specification. across road/ River/ Telecom line etc. in horizontalNerticle formation complete with Spool/Reel insulator.
Earthing with G. I pipe 2.5mtr. Long and 40mm dia, including excavation, refilling with alternate layer of salt & Charcoal as per drawing (including supply of G.l.Pipe, Salt & Charcoal, Gi wire, nuts &bolts, etc. as required)
Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Trench Size: Width-350mm, Hieght-1200mm Sand(couhioning): Hieght-250mm, Width-350mm/ Protection: Double layer Bricks Upto 120 sq. mm
Laying of one number PVC insulated and PVC sheathed I XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Upto 120 sq. mm
Jointing of outdoor heat shring type End termination jointing kit for 11KV XLPE, 120sqmm, 3-Core UG Cable.
Coiling of excess Single/3core/3~ Core, upto to 400sqmm, HV/MV, XLPE insulated, armoured power Cable direct into earth including excavation of earth upto a depth of 1500mm (Size pit should be 2250mmX2250mm or as per site requirement.) including 1st class brick protection of two layer flat brick soling , 300 mm. Fine sand (Local quary) for cushioning/bed and refilling and ramming the excavated soil as per direction of Engineer in charge.
Dismantling Single Phase Service Connection with PVC cable from nearby Electrical pole to Premises i/c. G.l.Wire,Reel Insulator
Dismantling Three Phase Service Connection with PVC cable from nearby Electrical pole to Premises i/c. G.l.Wire,Reel Insulator.
Laying of 8 SWG GI wire at 300mm below the ground level for earthing of Sub-Station equipments from the earth electrode
Febrication of Cross-Arms by MS Channel/MS Angle as per specification
Maintaining adequate clearance from overhead live conductors by Trimming of tree branches for Way Leaves
Carriage of materials such as Cable.AAC, AAAC, ACSR, G.l.Wire,Cross-Arm,Stay Set.Insulators etc., by Mechanical Transport from the Electrical SubDivisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required, upto the lead of 25KM & 50KM, a) Upto the lead range 25KM
Gouting of ST pole /Stay set with CC of ratio 1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size)complete with excavation , riffiling of earth, ramming along with centering & shuttering as reqd. @ 0.273 Cum per ST pole & 0.119Cum per stay set as per TSECL specification.
Applying priming coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Painting with aluminium paint of approved brand and manufacture to give an even shade
Manually digging /drilling horizontally or diagonali direction for road crossing I Water supply line/Telcomunication line/Gas Pipe line etc. including Laying of 64 to 200mm dia GI pipe direct into the earth at a depth of minimum 11OOmm below the ground surface with out effecting the existing road including excavation earth for entry pit as per site condition and direction of Engineering ln Charge
Laying of one number PVC insulated and PVCsheathed I XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Laying and fixing of one number PVC insulated andPVC sheathed XLPE power cable of 1.1 KV gradeof following size on wall surface as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Cartage of Power Cable from TSECL store or Stack sites by Mechanical Transport including loading, unloding and stacking/positioning by Light Crane up to work site: Weight of 3-Core. 6.35/11 kV XLPE Cable, Flat Strip(Kg/Km): 150sqmm(4700Kg), 185sqmm(5300Kg), 240sqmm (6300Kg), 300sqmm (7200Kg), 400sqmm (8700Kg), Above 120sqmm to 400sqmm
Reallignment of existing power cable / Repair, maintanance & replacement of damaged power cable(11&33KV Voltage grade) including excavation of earth, lift out of damaged power cable, bricks etc. and laying & commssioning of new power cable with supply of sand for coushnìng/bed for cable, laying of lift out bricks for protection of cable including refiliing of excavated earth and prpoer ramming (Cost including cartage of new cable from ESO stack yard to site and site to ESO stack yard.) Trench Size: Width-500mm, Hieght-1200mm I New Sand(couhioning): Hieght-300mm, Width-500mm. Above 150 sq. mm up to 400sqmm
ADHIR DEBNATH
KAJAL DAS
RATAN PAUL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .