Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.3 LAccepted-AOC RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹42.9 L+₹71,015 (1.68%)Rejected-Finance | L2 | Rejected-Finance Other than lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Feb 2023, 6:00 pmClosed
GE (AF) Halwara
GE (AF) Halwara
SPECIAL REPAIR TO INTERNAL WIRING IN DOMESTIC AREA AND GANTRIES OF WSAS AT AF STN HALWARA
2022_MES_571468_1
GE/HAL-58/2022-23
Open Tender
Civil Works
Item Rate
183 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS D CATEGORY b(i)
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹96,000
Yes
10 Feb 2023
27 Dec 2022
6 Feb 2023
27 Dec 2022
4 Feb 2023
21 Jan 2023
Amount
Taking down aluminium / copper point wiring with surface/ concealed stove enamelled steel/ PVC conduit or wooden batten ( light, fan, socket, or power ) including sunk in cast iron / pressed steel terminal boxes such as switches, ceiling roses, lamp holders, sockets, regulators, call bell, light fitting any sketch etc and making good disturbed surfaces of walls, floors etc complete all as specified and directed..
M & L for concealed Point wiring for light points with PVC insulated unsheathed FRLS two run of 1.5 Sqmm multi stranded copper conductor cable 1100 volts grade & one run of 1.5 Sqmm multi stranded copper conductor cable as continuous earth wire drawn in PVC conduit not less than 19/20 mm dia with all fittings shunk in MS Pressed steel terminal boxes suitable depth and 1.6mm thick (duly painted with two coat of anti corrosive paint outsite and Aluminium paint inside) with top cover 2.8 mm thick Hylem sheet cover for mounting of switches/sockets and fan regulators etc complete all as specified. Note:- Cost of cutting of chases wherever required in walls/ floors is deemed to be included in the unit rate of point wiring.
All as per item No. 2 above but for ceiling fan, one point controlled by one switch.
All as per item No. 2 above but for exhaust fan point, one point controlled by one switch.
All as per item No. 2 above but for socket outlet 5 Amps controlled by one switch on the same board.
All as per item No. 2 above but for one socket outlet 5 Amps controlled by one switch on independent board.
All as per item No. 2 above but for call bell point, one point controlled by one switch.
All as per item No. 2 above but for one light point controlled by two 2 - way switches with cable 1.5 sqmm size
All as per item No. 2 above but with 4.0 sqmm for one 15 Amps socket outlet on independent board and 2.5 sqmm PVC insulated multisranded copper conductor cable as continuous earth wire complete.
Supply and fixing Switch piano type one way 5 amps 240 volts complete.
Supply and fixing Bell push flush type 5 amps 240 volts complete.
Supply and fixing Socket outlet 5 pin 5 Amps flush type complete.
Supply and fixing Switch piano flush button single pole one way 15 amps 240 volts complete.
Supply and fixing Socket out let 2 in 1, 6 pin, 5 and 15 amps multi purpose flush type, 240 volts.
Supply and fixing electronic fan regulator stepped type, 240V flush type on the exiting phenolic laminated sheet etc.
Supply and fixing ceiling rose surface bakelite 3 terminals.
Supply & fixing Lamp holder PVC/ Polycarbonate insulated body with copper terminals, 240 volts with back plate for angle/batten fittings complete.
Supply and fixing retrofit LED lamp 9 watt light complete all as specified.
S&F LED light fitting 20 W, 4 Feet long 230V, Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete with all accessories internally pre-wired.and including connecting up with twin core twisted flexible copper conductor cable with suitable size as specified as in replacement complete all as specified.
All as per item No 19 above but LED light fitting 2 Feet long 10 Watt LED Batten light for mirror and as wall light application complete
S&F in repalcement of LED flat Bulkhead fitting 10 watt complete and fixing to wall / celing including fixing arrangement with clamps/ scrue/nuts/ bots /washers etc and connecting complete.
S&F in replacement of Building Security light fitting 35 W LED, new generation Energy Saving & Environment friendly long life versatile pressure die-cast aluminium IP-66 roadway luminars with high power LEDs as light source and electronic drive including mounting bracket, GI pipe 40mm dia medium grade for mounting bracket bent to shape upto 1.50 meter length and fixing arrangement with two Nos of MS clamps set, nut, bolts, washers, and applying two coats of aluminium paints over one coat of Zinc oxide primer complete all as directed.
S&F heavy duty 300mm sweep exhaust fan with 1.00mm thick louver shutters, turbo force 1400 RPM, single phase, totally enclosed heavy duty motor with copper winding including mouting brackets and frame, making holes in walls to fix exhaust fan, fixing wire mesh on outer side of exhaust hole and making good the wall surfaces including matching with the adjacent surfaces complete all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated cable of size 2 X 4 Sqmm + 1 X 4.0 Sqmm earth wire multi stranded copper conductor drawing into and including heavy duty 25mm dia surface PVC conduit and continuous earth wire complete and making good disturbed surfaces of wall/ floor etc. as in replacement including taking down existing wiring complete all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated cable of size 2 X 6 Sqmm + 1 X 6.0 Sqmm earth wire multi stranded copper conductor drawing into and including heavy duty 25mm dia surface PVC conduit and continuous earth wire complete and making good disturbed surfaces of wall/ floor etc. as in replacement including taking down existing wiring complete all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated cable of size 4 X 10 Sqmm + 1 X 10.0 Sqmm earth wire multi stranded copper conductor drawing into and including heavy duty 25mm dia surface PVC conduit and continuous earth wire complete and making good disturbed surfaces of wall/ floor etc.as in replacement including taking down existing wiring complete all as specified and directed.
S&F in replacement sheet metal enclosure with metal clad socket & plug including MCB SPN 32 Amp complete all as specified and directed.
S&F in replacment Loadline Vertical TPN DB prewired distribution board doble door, 12 way TPN-DPX 12-63, one No MCCB 200 Amps as incomer and 4 Nos of MCB SPN 40 Amp for outgoing as site required, double door type sheet metal enclosure 415V with 63 Amps rated standard busbar of suitable size plate and common neutral link without MCBs with blank plate suitable complete all as specified and as directed.
S&F in replacment sheet metal enclosure MCB SPN distribution board, 8 way, Double door with IP-43 protection single phase 240 volts, including suitable size copper bus bar and neutral link fixed flush concealed in wall including taking out old DB's and chases wall for fixing DB and making good distributed wall/surfaces to match with existing specification fixed in repairs complete all as specified and directed.
S&F in replacement 'B' series MCB SPN 63 amps, 240 volts, 50Hz.
S&F in replacement 'B' series MCB SP 6 to32 amps, 240 volts, 50Hz.
Supply and fix door bell, Ding Dong AC, 240 volts, single pole
Taking down carefully existing storage type water heater ( Geyser), disconnecting electric/water supply connections, dismantling (taking out/down) geyser vertical or horizontal type, any capacity, any make and transportation to MES yard, transporting back to site for installing and fixing in its original position complete all as specified.
Supply and replacement of water connection pipe, heavy duty PVC connection pipe size 15mm x 450mm for hot water connection for storage type water heater complete all as directed.
Taking down carefully existing ceiling fan and Exhaust fan any size/ sweep for depositing to MES Yard and re-hanging the same after complete rewiring including transportation and conneting the fan with 2 core flexible copper cable 23/0.0076 of required length connecting with ceiling rose and coverd with PVC round sheet complete all as directed.
M&L, connecting of 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 35 Sqmm nominal cross section 3.5 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers testing and commissioning complete all as specified including taking out existing unserviceable cable from trenches, floor, ducts, poles or roads complete all as directed (Earth work shall be measured and paid separately).
Excavation in trenches in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable etc. and getting out of excavated material complete all as specified and directed.
M&L for dry Sand cushioning to underground electric cable 8cm below and 15 cm above the cable all as specified in clause 19.75 of SSR Part-I Note:- (i) Sand shall be fine sand as specfied in clause 14.5 of SSR Part-I. (ii) Punned thickness shall be measured.
M&L Bricks laid in trenches flat with width equal to length of bricks for cable protection with well burnt sub class B bricks complete all as specified.
Returning, filling in approved excavated soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick all as directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as directed.
M & L for GI pipe 40mm dia bore light grade with all fittings for cable protection, and fixed complete to wall, panel, pole or laid in trenches and road crossing complete all as specified and directed.
S & F in repairs, installation, commissioning and testing Polycarbonate CPRI approved OEM made Meter Panel outdoor type. The Panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4 : Meter Panel type Wall Mounted type on Mounting Structure RAL 7016. The Meter Panel should be anti-acid, anti corrosive & Fully Transparent Door for meter Vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of his CPRI TEST REPORT IN POLYCARBONATE only also share panel assemble by OEM, channel partner or sister concerned assembly will not accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket should be internally embedded made of polyurethane. The manufacturer of panel shall submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1 complete all as specified and directed. The CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing. One Main Incomer MCCB 63A TPN 25KA Thermal /Magnetic Release with spreader link. MCCB/MCB Nob Operated by Flip Cover. Indicator Provided on each phase. Provn of Four Nos Single Phase Electric single phase Emergy Meters. Output supply by MCB DP 32Amp 4 Nos. Meter Enclosures & Enclosures Accessories as per RAL 7035. Ten Nos Terminal Blocks Provided for output Supply. Make- Hensel or equivalent as approved by GE. Note :- The rate quoted is inclusive of 4 Nos new single phase electric Energy meters)
M&L for earthing in repairs complete with Galvanised Iron earth plate electrode 60x60cmx6mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.50M below normal ground level, connected to galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR 2009 Part-I connected to earthing test point/transformer/panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1, PVC pit cover with frame, charcol, salt including provision of earth lead protected by 15mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering complete all as specified and directed by Engr-in-Charge.
Maintenance/serviceing of EOT 08 Ton capacity (electrically operated cranes) - 01 No complete all as specified and directed by Engr-in-Charge. The scope of work included is as under:- (i) Replacement of gear oil in gear boxes. (ii) Greasing the whole crane. (iii) Cleaning of gear boxes inside/outside with diesel before refilling. (iv) Checking the wheel condition. (v) If thruster breaks are used check the level of oil in it, If required to be refilled, refilling the same. (vi) Checking workability of the brake if required to replace, then replacement of the same. (vii) Checking the connections of motors and making it functional. (viii) Rewinding of the motors if required. (ix) Checking serviceability of couplers and replacment of same if required . (x) Replacment of unserviceable nut & bolts where required. (xi) Replacment of wire rope if required. (xii) Replacment of power cable if requied. (xiii) Replacement of brake shoe if required. (xiv) Replacmeent of limit switch if required. (xv) Checking step down transformer, single phase preventer, thermal block, MCB, HRC and DBR, if found unserviceable repalcement the same. (xvi) Checking of VFD installed, if found unsverviceable replacement of the same and check all the motions of VFD. (xvii) Checking the pendent, if element and push buttons found unserviceable replacement the same
All as per Sl item No 45 above but EOT 2 Ton capacity
All as per Sl item No 45 above but EOT 0.5 Ton capacity Notes for Sl No 45 to 47 above: 1. Gear/Transformer oil, grease, rewinding of motors and spare parts required for replacement shall be measured and paid separately under respective items as Supply only . 2. Parts replaced shall be identical to those provided by original manufacture. 3. Parts of minor nature such as screws & washers required at site are deemed to be included in the cost quoted. 4. Warrenty of crane for 01 year to be provided by the contractor through OEM/original manfacturer. 5. If crane is required to be shifted to OEM workshop for repair, rates are deemed to be included for dismantling and taking down , transportation to OEM workshop and back including refixing the same after reapirs and nothing extra is admissible on this account.
Material and labour for load testing of crane any type any make infront of Engr-in-Charge and Air Force authorities complete all as specified and as directed. Notes : (a) Load will be provided by AF authoriteis. (b) Load test certificate shall be provided by OEM/original manfacturer of crane.
Supply only Gear oil 90 No for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Transformer oil for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Grease for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Contactor 3 phase 24 Amp for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Contactor 3 phase 18 Amp for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Contactor 3 phase 12 Amp for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Contactor 3 phase 09 Amp for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Coupling for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Nut and bolts for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only VFD 15HP for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only VFD 5HP for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only VFD 3HP for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Rewinding of Hoist motor of capacity 10 HP to 7.5HP with super enamelled copper wire of size, gauge, weight and specification as that of exisiting material including insulation paper strips and thread etc complete all as specified and directed
Rewinding of electric motor of capacity 5 HP to 3HP with super enamelled copper wire of size, gauge, weight and specification as that of exisiting material including insulation paper strips and thread etc complete all as specified and directed
Rewinding of electric motor of capacity 3 HP to 0.5HP with super enamelled copper wire of size, gauge, weight and specification as that of exisiting material including insulation paper strips and thread etc complete all as specified and directed
Supply only Power cable 6 Sqmm x 4 core for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Power cable 4 Sqmm x 4 core for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Power cable 1.5 Sqmm x 4 core for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Step down transformer for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Single phase preventer for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Terminal block for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only 40 to 63 Amps TPN MCBs for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only DBR for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only wire rope 16mm for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only wire rope 12mm for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only wire rope 8mm for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only rope 6mm for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Thruster break 150mm for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Thruster break 100mm for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Break AC Shoe type 150mm for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Break AC Shoe type 100mm for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Break AC disc type 100mm for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Break shoe for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Limit switch HP for Hoist for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Limit switch LT & CT F/P for Hoist for Hoist for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Limit switch N/F/P for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Limit switch HP for Hoist for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Element of Limit switch for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Element of Push button for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Push button F/P station for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
Supply only Push button station N/F/P for EOT crane as per sample provided by OEM/original manfacturer and directed by Engr in charge.
BEHL AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .