Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.7 LAccepted-AOC 22 1685 ST JACOB CHURCH LANE PAMBAIMOOLA EDACOCHIN ERNAKULAM KERALA 682010 | ERNAKULAM | ERNAKULAM | KERALA | 682010 | ₹45.7 L Quoted ₹46.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹49.6 LRejected-AOC 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | ₹49.6 L | L2 | Rejected-AOC L2 |
| 3 | L3₹49.9 LRejected-AOC | ₹49.9 L | L3 | Rejected-AOC L3 |
| 4 | L4₹50.2 LRejected-AOC DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | ₹50.2 L | L4 | Rejected-AOC L4 |
| 5 | L5₹50.3 LRejected-AOC | ₹50.3 L | L5 | Rejected-AOC L5 |
| Sl No | Description | Qty | Unit | ZOOM ENTERPRISES L1 | MS BUILDERS L7 | WELTRONENGINEERINGSERVICES L2 | Phejays Agencies L5 | M/S AARJAY ASSOCIATES L6 | Bell Builders L3 | ELAN ENGINEERS L4 | Green Ray Enterprises L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Comprehensive maintenance of addressable fire alarm Morely make system installed at CNAI functionality of all components, cleaning all device, replacement of defective spares / components, comprising of following complete all as specified and as directed :-
(a)Microprocessor based control Panel 2 Loop - 02 No.
(b) Electronic siren - 02 Nos
(c) Manual call points - 40 Nos.
(d) Repeater Panels - 02 Nos.
(e) 36 AH Battery - 02 Nos | 11 | Per month | 12,000 ₹1.3 L | 6,000 ₹66,000 | 11,000 ₹1.2 L | 12,000 ₹1.3 L | 9,500 ₹1.0 L | 7,500 ₹82,500 | 7,000 ₹77,000 | 8,000 ₹88,000 |
| 2.00 | All as per item Sl No 02 here-in-before but at TSK comprising of following complete all as specified and as directed:
(a)Microprocessor based control panel 2 Loop - 01 No.
(b) Electronic siren - 03 Nos
(d) Manual call points - 54 Nos.
(e) Repeater Panels - 02 Nos.
(f) 36 AH Battery - 02 Nos
Note for item No 1 & 2 :-
a) Contractor shall maintain all the documents and produce to the concerened Engineer in Charge as and when required /preparation of RAR
b) Contractor shall give the demo and training for all duty staffs about the fire alarm System. The unit rate quoted is deemed to be included for the same
(c)Spares required for replacement, shall be measured seperately as 'supply only' under respective items. | 11 | Per month | 12,000 ₹1.3 L | 9,000 ₹99,000 | 6,000 ₹66,000 | 8,000 ₹88,000 | 6,500 ₹71,500 | 10,000 ₹1.1 L | 8,500 ₹93,500 | 10,000 ₹1.1 L |
| 3.00 | Supply only addressable manual call point resettable type complete all as specified and as directed | 10 | Each | 3,000 ₹30,000 | 9,000 ₹90,000 | 5,000 ₹50,000 | 8,000 ₹80,000 | 7,000 ₹70,000 | 10,000 ₹1 L | 5,500 ₹55,000 | 4,000 ₹40,000 |
| 4.00 | Supply only detectors complying with and type certified to EN - 45 Addressable type multisensor smoke detector with heat and smoke combination with base with self built intelligence as per IS: 11360 complete all as specified and as directed | 15 | Each | 2,800 ₹42,000 | 4,000 ₹60,000 | 5,000 ₹75,000 | 3,500 ₹52,500 | 5,000 ₹75,000 | 5,000 ₹75,000 | 6,500 ₹97,500 | 6,600 ₹99,000 |
| 5.00 | Supply and fix battery maintanance free 12 Volt 36 Ampere hour complete all as specified and as directed | 3 | Each | 7,000 ₹21,000 | 2,500 ₹7,500 | 6,000 ₹18,000 | 3,000 ₹9,000 | 5,000 ₹15,000 | 1,500 ₹4,500 | 7,500 ₹22,500 | 7,700 ₹23,100 |
| 6.00 | Supply and laying fire alarm cable of 2 core 1.5 sqmm FRLS armoured copper conductor cable complete all as specified and as directed | 480 | RM | 145 ₹69,600 | 80 ₹38,400 | 90 ₹43,200 | 60 ₹28,800 | 75 ₹36,000 | 100 ₹48,000 | 150 ₹72,000 | 120 ₹57,600 |
| 7.00 | Material and labour for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for filling of road cuttings etc complete all as specified and as directed | 4.5 | Cum | 6,000 ₹27,000 | 4,000 ₹18,000 | 5,000 ₹22,500 | 3,500 ₹15,750 | 4,600 ₹20,700 | 3,000 ₹13,500 | 4,500 ₹20,250 | 4,400 ₹19,800 |
| 8.00 | Supply and fix single phase surge protection device type 1 & 2 tested for lighting impulse current 10/350 micro second 50 KA for phase to neutral and 125 KA for neutral to earth, surge protection device tested for nominal discharge current 8/20 micro second 20 KA phase to neutral voltage protection level,<=1.4kv, encapsulated spark technology for line to neutral for type 1 and metal oxide for varistor for type 2 line to neutral. LED indication in line to neutral pole in type 1 and flag indication in type 2 line to neutral, response time for type 1 is less than 100 nano second and type 2 is less than 25 nano second, DIN rail mounted complete all as specified and as directed | 14 | Each | 16,000 ₹2.2 L | 3,000 ₹42,000 | 3,000 ₹42,000 | 2,500 ₹35,000 | 3,700 ₹51,800 | 4,000 ₹56,000 | 2,500 ₹35,000 | 2,200 ₹30,800 |
| 9.00 | Material and labour for earthing with copper earth plate of size 600 x 600 x 3.15 mm thick buried directly in ground not less than 2.25 metre below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150 mm in layers, connected by copper strip of size 20 x 3 mm thick, soldered and riveted to earth plate. GI earth strip will be protected by using 40mm bore GI pipe (light grade) earth plate to transformer body, LT feeder pillar box, and neutral of transformer etc complete. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20 mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 metre etc complete all as specified and shown in electrical plate No 3 of SSR Part I - 2009.
Note: - Earth lead with copper strip of size 20x3mm up to 7.5 metre is deemed to be included in the unit rate quoted. | 12 | Each Set | 14,000 ₹1.7 L | 12,000 ₹1.4 L | 13,000 ₹1.6 L | 18,000 ₹2.2 L | 14,000 ₹1.7 L | 13,000 ₹1.6 L | 12,500 ₹1.5 L | 12,200 ₹1.5 L |
| 10.00 | All as per item No 9, here-in-before but using galvanised earth plate of 600 x 600 x 6 mm with iron strip 32×6mm as earthing lead complete all as specified and as directed | 4 | Each Set | 7,000 ₹28,000 | 5,000 ₹20,000 | 6,000 ₹24,000 | 4,500 ₹18,000 | 6,500 ₹26,000 | 6,000 ₹24,000 | 5,500 ₹22,000 | 5,500 ₹22,000 |
Tender Value
Refer Docs
EMD Value
₹96,120
Closing Date
29 Jul 2025, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
COMPREHENSIVE MAINT OF STREET LIGHT, SECURITY LIGHT, LAMP AND REPAIR/REPLACEMENT OF MISC EQUIPMENT HOT/EOT CRANES, FIRE ALARM ETC AT NAD AREA UNDER AGE B/R ALWAYE
2025_MES_718762_1
8518/E8
Open Tender
Electrical and Maintenance Works
330 days
ALWAYE
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹96,120
Yes
12 Feb 2026
5 Jul 2025
31 Jul 2025
5 Jul 2025
29 Jul 2025
21 Jul 2025
5 Jul 2025 - 6 Jul 2025
Amount
Comprehensive maintenance of addressable fire alarm Morely make system installed at CNAI functionality of all components, cleaning all device, replacement of defective spares / components, comprising of following complete all as specified and as directed :- (a)Microprocessor based control Panel 2 Loop - 02 No. (b) Electronic siren - 02 Nos (c) Manual call points - 40 Nos. (d) Repeater Panels - 02 Nos. (e) 36 AH Battery - 02 Nos
All as per item Sl No 02 here-in-before but at TSK comprising of following complete all as specified and as directed: (a)Microprocessor based control panel 2 Loop - 01 No. (b) Electronic siren - 03 Nos (d) Manual call points - 54 Nos. (e) Repeater Panels - 02 Nos. (f) 36 AH Battery - 02 Nos Note for item No 1 & 2 :- a) Contractor shall maintain all the documents and produce to the concerened Engineer in Charge as and when required /preparation of RAR b) Contractor shall give the demo and training for all duty staffs about the fire alarm System. The unit rate quoted is deemed to be included for the same (c)Spares required for replacement, shall be measured seperately as 'supply only' under respective items.
Supply only addressable manual call point resettable type complete all as specified and as directed
Supply only detectors complying with and type certified to EN - 45 Addressable type multisensor smoke detector with heat and smoke combination with base with self built intelligence as per IS: 11360 complete all as specified and as directed
Supply and fix battery maintanance free 12 Volt 36 Ampere hour complete all as specified and as directed
Supply and laying fire alarm cable of 2 core 1.5 sqmm FRLS armoured copper conductor cable complete all as specified and as directed
Material and labour for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for filling of road cuttings etc complete all as specified and as directed
Supply and fix single phase surge protection device type 1 & 2 tested for lighting impulse current 10/350 micro second 50 KA for phase to neutral and 125 KA for neutral to earth, surge protection device tested for nominal discharge current 8/20 micro second 20 KA phase to neutral voltage protection level,<=1.4kv, encapsulated spark technology for line to neutral for type 1 and metal oxide for varistor for type 2 line to neutral. LED indication in line to neutral pole in type 1 and flag indication in type 2 line to neutral, response time for type 1 is less than 100 nano second and type 2 is less than 25 nano second, DIN rail mounted complete all as specified and as directed
Material and labour for earthing with copper earth plate of size 600 x 600 x 3.15 mm thick buried directly in ground not less than 2.25 metre below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150 mm in layers, connected by copper strip of size 20 x 3 mm thick, soldered and riveted to earth plate. GI earth strip will be protected by using 40mm bore GI pipe (light grade) earth plate to transformer body, LT feeder pillar box, and neutral of transformer etc complete. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20 mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 metre etc complete all as specified and shown in electrical plate No 3 of SSR Part I - 2009. Note: - Earth lead with copper strip of size 20x3mm up to 7.5 metre is deemed to be included in the unit rate quoted.
All as per item No 9, here-in-before but using galvanised earth plate of 600 x 600 x 6 mm with iron strip 32×6mm as earthing lead complete all as specified and as directed
All as per item No 9 here-in-before but using galvanised earth plate of 600 x 600 x 6mm with iron strip 25×4mm as earthing lead complete all as specified and as directed
Supply and fix earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required copper earth strip 20 x 3 mm with saddles/fasteners/ insulators and fixing screws etc. complete all as specified and as directed
All as per item No 12 here-in-before but GI strip 25 x 4mm buried in ground or on wall/pole etc complete all as specified and as directed
All as per item No 12 here-in-before but GI strip 32 x 6mm buried in ground or on wall/pole etc complete all as specified and as directed
Material and labour in replacement of test terminal block made of gun metal or phosphorus bronze size 75mmx75mmx25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws complete all as specified and as directed
Material and labour 40mm bore galvanised steel tubing, light grade, fixed on the top of the roof with socket/clamps or by welding etc. for fixing single point air termination rod for lightening conductor support as required at site including removing of the old rusted pipe complete as specified and as directed.
All as per sl item No 16 here-in-before but for 50 mm dia bore complete all as specified and as directed
Material and labour for steel tubular swaged poles complete with cast iron base plate, final tapper plug, bolt, nuts and screws as specified type 410 SP-31, 9 metre long and applying one coat of aluminium paint over a coat of red oxide primer,arrangement for fixing air termination rod and earth strip including dismantling old one complete all as specified and as directed.
All as per sl item No 18 here-in-before but for SP 55 of 11 mtrs complete all as specified and as directed
Supply and fix in replacement of air termination single pointed copper rod 12mm dia 300mm long for lightning protection complete all as specified and as directed
Supply and fix in replacement of air termination single pointed aluminium rod 12mm dia 300mm long for lightning protection complete all as specified and as directed
Supply and fix in replacement of air termination single pointed aluminium rod 12mm dia 1 metre long complete all as specified and as directed
Material and labour for stay assembly complete with accessories comprising 20mm dia galvanised stay rod threaded end with nut 215cm long. 6mm thick MS stay plate of size 300x300mm, 2 Nos galvanised bolts, all as shown in electrical plate No 1 of SSR Part 1 including necessary earth work excavation & plain cement concrete etc and taking out old stay assembly complete all as specified and as directed
Supply and fix in replacement of galvanised stay wire of size 7/2.5 mm as required at site including necessary clamps, nut and bolts complete to hold the existing lightning arrestor pole in positioncomplete all as specified and as directed
Material and labour for stringing aluminium conductor steel reinforced on tubular poles as suspension conductor for lightening protection system including removing of the existing old conductor complete all as specified and as directed
Supply and fix in repair Loop type insulator, vitreous porcelain, white, brown or green, Small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as specified and as directed
Material and labour for testing earth resistance between conductor and earth value for the building and lightining conductors including writing the date of testing, next due date of testing on the space provided. Testing will be done twice in a contract period after completion of 6 months from the first testing complete all as specified and as directed (Note :- After testing twice the quantity will be measured as one job).
Routine servicing, maintanance of DG sets upto 20 KVA of any make to be carried out including supply & replacement of lubricating oil filter elements, fuel filter elements, air cleaner element inner & outer with necessory 'O' ring, engine oil, making good any leakages of oil, greecing the shaft fan motor, bearings and testing complete all as directed Note :- Engine oil shall be measured and paid separately.
All as per Sl No 28 here-in-before but of capacity 160 KVA complete all as specified and as directed
All as per Sl No 28 here-in-before but of capacity 500 KVA complete all as specified and as directed
Material and labour for dismantling of self starter 12/24V from engine and transporting to workshop for repair, opening cleaning and replacing defective bushes, bentex pinion ball bearing,plunger assembly, solenoid switch,carbon brushes,brush spring including varnising of coils heating, drying etc for DG set of 30 KVA capacity complete all as specified and as directed
Servicing /overhauling of Turbo charger by replacing Turbo charger kit incluidng testing on completion of 30 KVA capacity Gen set complete all as specified and as directed
Supply and replace fan belt suitable for 20 KVA capacity Gen set complete all as specified and as directed
Material and labour for removing the old engine oil from the diesel engine sump of various DG sets,cleaning the oil sump thoroughly,supply and fill new engine oil multi grade OMD-110/20W 40/SAE 40 in replacement of old engine oil complete all as specified and as directed
Supply and fix in repair AVR unit suitable for 20/30 KVA DG Set as per existing make and model complete all as specified and as directed
Material and labour for repairs to rectifier unit of alternator and replacing defective diods, surge arrestor and its wiring and testing complete of 30 KVA DG Set complete all as specified and as directed
Material and labour for servicing of DG panel, cleaning, checking of electric connections, replacing defective components, meter, relays, indicating lamps, and all other control systems for the proper functioning of the panel of DG set 500 KVA complete all as specified and as directed
All as per item No 37 here-in-before but for 160 KVA
All as per item No 37 here-in-before but for 82.5 KVA
All as per item No 37 here-in-before but for 20 KVA
Supply and fill coolent for radiator for any type of DG set complete all as specified and as directed
Material and labour for servicing of 20/30 KVA, 380 Volts online UPS by servicing of all parts, making all electrical connections, applying petrolium gelly to battery terminals, repair/replacement of battery leads, repair of parts, make the UPS functional complete all as specified and as directed
Supply and fix in repair burnt/unserviceable printed circuit board of UPS suitable for 30 KVA capacity at site as per Unicorn make and model including dismantling old one complete all as specified and as directed.
All as per item No 43 here-in-before but for 20 KVA capacity at site as per Powerone make and model
Supply and fix in repair capacitor suitable for online UPS of 30 KVA capacity at site as per Unicorn make and model including dismantling old one complete all as specified and as directed
All as per item No 45 here-in-before but for 20 KVA capacity at site as per Powerone make and model
Supply and fix in repair 3 phase Inverter mother board of UPS suitable for 20 KVA capacity at site as per Powerone make and model including dismantling old one complete all as specified and as directed
All as per item No 47 here-in-before but 30 KVA capacity at site as per Unicorn make and model
Supply and fix in repair sealed lead acid battery of 12 volts, 65 Ampere hour including taking down old unserviceable battery complete all as specified and as directed
Supply and fix in repair 3 phase sensing transformer of UPS suitable for 20 KVA capacity at site as per Powerone make and model including dismantling old one complete all as specified and as directed .
All as per item No 50 here-in-before but 30 KVA capacity at site as per Unicorn make and model
Supply and fix in repair 3 phase Insulated Gate Bipolar Transistor drive card of UPS suitable for 20 KVA capacity at site as per Power one and model including dismantling old one complete all as specified and as directed
All as per item No 52 here-in-before but 30 KVA capacity at site as per Unicorn make and model
Servicing/Maint of electric/hand operated travelling crane removing old grease, dust, rust, cleaning with kerosene and apply new grease in all moving parts/bearings upto 5 ton capacity complete all as specified and as directed
Supply and replace clutch assembly for 3 ton capacity of HOT crane complete all as specified and as directed
Supply and replace gear arm suitable for 3 ton capacity of HOT crane complete all as specified and as directed
Load testing of electric / hand operated crane by transporting dummy load from NAD factory to the site where cranes load to be tested and vice versa of capacity upto 5 Ton complete all as specified and as directed. Note :- Load test to be done by Govt approved firm/rep and test certicate to be submitted to the Engr-in-Charge.
Supply and fix manual overhead crane hoist including operating chain upto 3 ton cap complete all as specified and as directed
Supply and fix manual overhead crane operating chain upto 3 ton cap, crane height 5 to 18 mtrs, with locking arrangement including dismantling old one complete all as specified and as directed
Material and labour for painting of EOT/HOT cranes and their all components & machines as per MES colour code with one coat synthetic enamel paint including preparation of surfaces, writing of date of testing, due date of testing, capacity,SM/MES No etc, welding work on hand railing and brackets where broken of capacity upto 5 Ton complete all as specified and as directed
Supply and fix, 5000 litres capacity rotational moulded polyethylene water storage tanks (ISI marked) (cylindrical; vertical; with closed top) hoisted & fixed in position including taking down the unserviceable old one complete all as specified and as directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, laying of pipes, cables, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed
Supply and spreading locally available dry M-Sand for covering and cushioning of UG cable in trenches complete all as specified and as directed Note:- Punned thickness only shall be measured. Sand cushioning shall be done as specified in MES schedule.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and as directed
Supply laying and testingg XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm x 3.5 core including taking out old unserviceable items complete all as specified and as directed
All as per item No 67 here-in-before but for cross-sectional area 25 sq. mm x 4 core complete all as specified and as directed
All as per item No 67 here-in-before but for cross-sectional area 10 sq. mm x 4 core complete all as specified and as directed
All as per item No 67 here-in-before but for cross-sectional area 10 sq. mm x 2 core complete all as specified and as directed
Supply and fix 3 core flexible Aluminium cable 4 sqmm from cable junction box to street light fitting with and including ERW Steel conduit of 20 mm dia with clamps, nuts, bolts etc complete all as specified and as directed
Supply and fix outdoor type, weather proof, thermoplastic polycarbonate cable junction box of size not less than 260x210x120mm, IP-67/69 in accordance with IEC60529, with 5 pole terminal suitable to terminate 2 / 4 core 25 sqmm cables with metric knock outs on side walls including dismantling old one complete all as specified and as directed
All as per item No 72 here-in-before but of size not less than 210x160x100 mm complete all as specified and as directed
Supply and fix in repair MCB SPN 6 to 32 Amps, 220 volts, 10 KA, 'C' Series including dismantling old one complete all as specified and as directed
Supply and fix street lights 90 watt, aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection. Efficacy ≥ 120LPW with 10KV SPD including dismantling old one complete all as specified and as directed
All as per item No 75 here-in-before but of 60 watt complete all as specified and as directed
All as per item No 75 here-in-before but of 45 watt complete all as specified and as directed
All as per item No 75 here-in-before but of 30 watt complete all as specified and as directed
Supply and fix GI Bracket 40mm dia made out of medium grade pipe of 1.2 mtr length in bending 120 degrees shape including clamp of flat iron with nut bolts washers including taking down old unserviceable bracket complete all as specified and as directed.
Supply and fix 10 watt IP 65 Rated pyramid tripod type LED bollard with soft 360 degree light distribution including fixing arrangement including dismantling old one complete all as specified and as directed.
Supply and fixing 25 Watt new generation, Post-Top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, Spun aluminium landscape luminaire with high power (Surface Mounted Device) LED as lighting source with IP65 Protection including dismantling old one complete all as specified and as directed.
Supply and fix new generation, energy saving environment friendly, long life LED Flood light 150 watt mae up of pressure die cast aluminium housing with high power LEDs and secondary lenses with IP 66 protection. System eficiacy > 110 LPW with 10kv built in surge protection device including dismantling old one complete all as specified and as directed.
Supply and fixing new generation,10 Watt sturdy LED Bollard of 1 mtr height with excellent light output through its Polymethyl methacrylate window, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, landscape luminaire with high power LED as lighting source with IP65 Protection, fixed to ground by means of 4 Nos M10 Bolts including dismantling old one complete.
Supply and fix 25 watt all in one solar LED Street light fitting with inbuilt lithium battery , monocrystalline solar panel of 45Wp, Eficiacy of 120 Lumen/watt, MPPT + AC-DC LED driver, 30 AH lithium ferro phosphate (Life P04) Battery, 2 days backup, hybridwith 10KV -5KA SPD Operating voltage 180 V-230 V, Passive Infrared motion sensor (Active Passive Infrared sensor light glows to 100% for 30 seconds upon motion detection returns to 30% after that) suitable for mounting on pole including dismantling old one complete all as specified and as directed.
Supply and fix 20 watt all in one solar LED Street light fitting with inbuilt lithium battery , monocrystalline solar panel of 40Wp, Eficiacy of 120 Lumen/watt, MPPT + AC-DC LED driver, 12.8v/24 AH lithium ferro phosphate (Life P04) Battery, 2 days backup, hybridwith 10KV -5KA SPD Operating voltage 180 V-230 V, Passive Infrared motion sensor (Active Passive Infrared sensor light glows to 100% for 30 seconds upon motion detection returns to 30% after that) suitable for mounting on pole including dismantling old one complete all as specified and as directed.
Supply and fix 60 watt all in one solar LED Street light fitting with inbuilt lithium battery , monocrystalline solar panel of 90Wp, Efficacy of 120 Lumen/watt, MPPT + AC-DC LED driver, 12.8v/42 AH lithium ferro phosphate (LifeP04) Battery, 2 days backup, hybrid with 10kv -5ka SPD Operating voltage 180 V-230 V, Passive Infrared motion sensor (Active Passive Infrared light glows to 100% for 30 seconds upon motion detection returns to 30% after that) suitable for mounting on pole including dismantling old one complete all as specified and as directed.
Supply and fix LED Street light driver 30 watt to 100 watt as per existing one complete all as specified and as directed
Supply and fix hot dipped GI Octagonal pole of 6 mtrs long with single arm, complete arrangement suitable for mounting of LED Street light fitting, with bottom dia 130mm, top dia 70mm with 3mm sheet thickness with and foundation nut, bolts complete includin necessary earthwork excavation and PCC as per OEM Drawings including dismantling old one complete all as spcified and as directed.
All as per item No 88 here-in-before but of size 5 mtrs complete all as specified and as directed
Material and labour for decorative swaged pole with bottom dia 114mm, top dia 60mm with height swaged at 2500 mm with total length 5.5 metres, die cast base of dia 340mm, decorative casting rings with arm and fixing arrangement including erection of pole, nut, bolts etc including dismantling old one complete all as specified and as directed.
Supply and fixing 60 watt new generation decorative street light, downwards having 360 degree beam angle, energy saving and environmental friendly long life aesthetically designed with symmetrical light distribution, with IP66 Protection along with tight fixture with inbuilt 5KV surge protection, including dismantling old one complete all as specified and as directed.
Supply and fixing 35 watt new generation, modern look, post-top, long life aesthetically designed with symmetrical light distribution, with high power LED as lighting source with IP66 Protection perfect synchronization with functionality and aesthetics including dismantling old one complete all as specified and as directed.
Supply and fixing 45 watt circular LED post-top, offering excellent uniform illumination and aesthetics in one go. made up of die cast aluminium body landscape luminarie with high power LED as lighting source unique ring shape LED engine ensuring soothing, glare free light distributionwith IP66 Protection including dismantling old one complete all as specified and as directed.
Material and labour for aesthetically designed decorative hot dipped galvanised mild steel step pole with grey powder finish compactable for all post top range, window- plasma cut and duly chamfered opening window of 300x110mm for terminal connections and mounting accessories. Window cover is fitted with allen screws to the pole, decorative sleek casting ring to increase aesthetical appeal of 3.5 metre including erecting of pole and fixing arrangement including dismantling old one complete all as specified and as directed.
Supply and fix new generation energy saving and environmental friendly long life LED high bay light 150 watt in PDC housing suitable for industrial application, lumen efficiency not less than 140 lumen/watt and upto150 lumen/watt with IP66 Protection including fixing arrangements Hanging chains etc, including dismantling old one complete all as specified and as directed.
Supply and fix in repair energy saving and environmental friendly new generation, decorative IP 66 LED spike light 15 watt including dismantling old one complete all as specified and as directed
WELTRONENGINEERINGSERVICES (BID ID -3375855)
Bell Builders (BID ID -3376171)
ELAN ENGINEERS (BID ID -3376018)
Phejays Agencies (BID ID -3376044)
M/S AARJAY ASSOCIATES (BID ID -3376137)
MS BUILDERS (BID ID -3375785)
Green Ray Enterprises (BID ID -3376140)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid