| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹12.4 L+₹1.7 L (15.6%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹12.5 L+₹1.8 L (16.4%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹12.7 L+₹2.0 L (18.7%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹13.0 L+₹2.3 L (21.4%)Rejected-AOC ALSAFA COLONY SOPORE SOPORE ALSAFA COLONY 193201 SOPORE BARAMULLA JAMMU KASHMIR 193201 | BARAMULLA | JAMMU AND KASHMIR | 193201 | L5 | Rejected-AOC Rejected |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
18 May 2020, 6:00 pmClosed
GE 969 EWS
GE 969 EWS C O 56 APO
REPAIR MAINT OF INTERNAL WIRING INCLUDING FITTING AND FIXTURES AT URI GRN UNDER GE 969 EWS
2020_MES_341409_1
CANO 969/WS- /2020-21
Open Tender
Civil Works
Item Rate
270 days
Uri
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE 969 EWS
₹30,000
Yes
29 May 2020
28 Apr 2020
20 May 2020
28 Apr 2020
18 May 2020
12 May 2020
Amount
Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc, Complete all as specified and directed by Engineer-In-Charge.
M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor for One light point/fan point/Ex fan point controlled by one 5 Amps switch one way, Complete all as specified and directed by Engineer-In-Charge.
All as per ser item no.2 above but one 3 pin 5 Amp switch socket outlet on independent board.
All as per ser item no.2 above but one 3 pin 5 Amp switch socket outlet on same board with accessories.
M&L for point wiring in PVC casing caping with 2.5 sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor, Complete all as specified and directed by Engineer-In-Charge.
S&F switch piano Flush type, single pole, one way 6 amp 240 volts, Complete all as specified and directed by Engineer-In-Charge.
S&F switch piano Flush type, single pole16 amp 240 volts, Complete all as specified and directed by Engineer-In-Charge.
S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type Complete all as specified and directed by Engineer-In-Charge.
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type Complete all as specified and directed by Engineer-In-Charge. Make : Anchor / Bajaj / Havells.
S&F Switch socket combination 2 in1, 3 pin,5 Amps flush type,universsal Complete all as specified and directed by Engineer-In-Charge.
S&F Switch socket combination 2 in1, 3 pin,5 and 15Amp flush type,universsal Complete all as specified and directed by Engineer-In-Charge.
S&F switch modular single pole one way 6 amp 240 volts,1 Module, Complete all as specified and directed by Engineer-In-Charge.
S&F switch modular single pole one way 16 amp 240 volts,1 Module, Complete all as specified and directed by Engineer-In-Charge.
S&F Modular socket 6A - 2/3 pin combined 2 module, Complete all as specified and directed by Engineer-In-Charge.
S&F Modular socket 6A /16A- 2/3 pin combined 2 module, Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs Modular Bell Push 6 Amp , One module Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs Bell electric, Ding Dong AC 230 Volts, single pole Complete all as specified and directed by Engineer-In-Charge.
S&F stepped type modular fan regulator ,120 W, 1/2 module, Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet Complete all as specified and directed by Engineer-In-Charge.
Supply and fixing in repairs ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body, Complete all as specified and directed by Engineer-In-Charge.
Supply and fixing in repairs Plug top 15A 24V Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs distribution board, TPN, 4 Way, Double door Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs Distribution Board, SPN 12 Way, Double door Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs Distribution Board, SPN 8 Way, Single door Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs MCB SP 6 to 32 Amps, 240 Volts, B Curve Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs MCB SPN 6-32A Amps 240 Volts B Curve Complete all as specified and directed by Engineer-In-Charge.
S & F in repairs MCB,SPN 40 Amps 240 Volts B curve, Complete all as specified and directed by Engineer-In-Charge.
S & F in repairs MCB, TPN 40 Amps 415 Volts C curve, Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs exhaust fan/brisk air fan of size 200 mm sweep, non matallic Complete all as specified and directed by Engineer-In-Charge. Make : Havells code No. Ventil Air - DX White or eqvlnt in CG/Bajaj.
S&F in repairs LED Lamp 10 W. Make : Havells/Philips / Bajaj/Crompton, Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs LED Lamp 15 W. Make : Havells/Philips / Bajaj/Crompton, Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs 10W LED Complete all as specified and directed by Engineer-In-Charge. Make : Havells/ BAJAJ/PHILIPS/CG.
S&F in repairs surface and wall mounted LED batten, exttruded aluminium housing provided for efficient heat discipation with polycarbonate diffuser and intergrated electronic driver including LED tube 1x20W, 230 Volt Complete all as specified and directed by Engineer-In-Charge. Make : Havells/Philips / Bajaj/Crompton.
S&F in repairs LED Mirror Light "Eco Smart Linea" 18 Watts made of extruded engineering plastics suitable for surface mounting on a ceiling or wall Complete all as specified and directed by Engineer-In-Charge.Make : Havells/Philips/ Bajaj/Crompton
S&F in repairs 18 W LED panel round/square type, slim, compact, auminum die cast edge lit panel. recess/ceiling mounted square/round fixture with opal diffuser and separate electronic driver including connecting cable of suitable size complete all as specified and as directed by Engr-in-Charge. Make : Havells/Bajaj/Philips/CG.
M & L for sub main wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc incld taking down old u/s sub main wiring.Complete all as specified and directed by Engineer-In-Charge. Note: Two runs of 6 sqmm and one run of 6 sqmm earthing cable and one run of casing capping shall be measured as one RM.
S&F in repairs 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 6 sqmm Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 10 sqmm Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 16 sqmm Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs 1.5 sq mm copper conductor (multistranded), fire retardent low smoke , single core PVC insulated, unsheathed, 1100 volt grade cable conforming to IS- 694 part I Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs 2.5 sq mm copper conductor (multistranded), fire retardent low smoke , single core PVC insulated, unsheathed, 1100 volt grade cable conforming to IS- 694 part I Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs 4.0 sq mm copper conductor (multistranded), fire retardent low smoke , single core PVC insulated, unsheathed, 1100 volt grade cable conforming to IS- 694 part I Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs heating element including rubber gasket & washer etc of capacity 1.5 KW suitable for existing make and shape Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs heating element including rubber gasket & washer etc of capacity 2 KW suitable for existing make and shape. Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs thermostat including rubber / PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 / 35 / 50 ltrs. Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs PVC connecting pipe 18" long with brass adopters for cold/hot water and connecting up with complete for 25 /35 / 50 ltrs capacity Geysers. Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs indication lamp for 25 / 35 / 50 ltrs capacity Geysers. Complete all as specified and directed by Engineer-In-Charge.
M&L for servicing of geysers of any capacity by opening of entire geyser and cleaning all the sludges, blockages, dust, etc Complete all as specified and directed by Engineer-In-Charge.
Taking down the ceiling fan from site and removing its allied smaller parts such as bearings/bushes, etc and refixing the same in its original position with all the parts i.e. down rod, canopies, fan blades, new spilt pins, screws, nuts and spring washers complete including, flexible cord of 24/0.2mm with necessary connector (for blade/body) as required after rewinding Complete all as specified and directed by Engineer-In-Charge.
All as per item No.50 above but exhaust fan of any sweep, Complete all as specified and directed by Engineer-In-Charge.
M&L for rewinding the ceiling fans using super enamelled copper conductor of suitable gauge including insulation, varnishing, packing, etc complete reinstalling after winding Complete all as specified and directed by Engineer-In-Charge.
M&L for rewinding the exhaust fans using super enamelled copper conductor of suitable gauge including insulation, varnishing, packing, etc complete reinstalling after winding Complete all as specified and directed by Engineer-In-Charge.
S&F in repairs ball bearing suitable for ceiling fans of any sweep. Make :SKF/NBC
S&F in repairs ball bearing suitable for exhaust fans of any sweep. Make :SKF/NBC
M&L for cleaning and painting of ceiling fan with one coat of synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc including taking down Complete all as specified and directed by Engineer-In-Charge.
M&L in repairs for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, returning, filling in and removal etc
M/s FAYAZ AHAMD WANI AND SONS
M/s Mohammad Shafi Malik
M/S DALJIT SINGH TULLA
M/S GHULAM NABI KHUROO AND CO
Javeed And Co
m/s mohd rafiq lone
M/S PARADISE TRADERS AND CO
M/S Khan Hussain & Co.
M/S MUKHTAR CONSTRUCTION CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .