Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-AOC 381 2 SATYA VIHAR MANDIR MARG VIJAY PARK DEHRADUN 248001 UK | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.0 L+₹31,492.50 (0.86%)Rejected-AOC 63 MANDIR LANE BALLUPUR CHOWK DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC Being L2 | |
| 3 | L3₹37.1 L+₹47,352.50 (1.29%)Rejected-AOC 79B MIG PHASE 1 INDIRA PURAM G M S ROAD DEHRADUN UK PIN 248171 | DEHRADUN | UTTARAKHAND | 248171 | L3 | Rejected-AOC Being L3 | |
| 4 | L4₹39.8 L+₹3.1 L (8.48%)Rejected-AOC WING NO 7 2 10 PREMNAGAR DEHRADUN UK | L4 | Rejected-AOC Being L4 | |
| 5 | L5₹43.4 L+₹6.7 L (18.4%)Rejected-AOC | L5 | Rejected-AOC Being L5 |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
6 Mar 2021, 6:00 pmClosed
CWE Dehradun
HQ CWE Dehradun The Mall Road Dehradun Cantt
SPECIAL REPAIR TO SECOND FLOOR OF NAUSHERA COY BLDG NO (P-107) CA BN AT IMA DEHRADUN
2021_MES_419381_1
8728/IMA/29/E8
Open Tender
Civil Works
Item Rate
180 days
Dehradun
As per NIT
8 documents required · 8 mandatory
₹500
GE IMA Dehraun
₹97,000
Yes
17 Jun 2021
5 Feb 2021
8 Mar 2021
5 Feb 2021
6 Mar 2021
27 Feb 2021
Amount
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified and directed.
Dismantling of wall and ceiling board as in existing cup board of pre laminated particle board from existing position including racks, fitting and fixture complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but n.exc 4 Sqm each complete all as specified and directed.
Taking down chowkhat with shutter (without taking off shutters from frame) not exceeding 1.5 Sqm each complete all as specified and directed.
Taking down of shutter of any description exceeding 1.0 Sqm but not exceeding 2.0 sqm each complete and refixing in the same opening complete all as specified and directed.
Taking down chowkhat or frames not exceeding exc 1.5 Sqm but n. exc 4 Sqm each complete all as specified and directed.
Taking down of cement plaster of any description including racking our joints hacking for key and scrubbing down with water complete all as specified and directed.
M&L for RCC (1:2:4) type B1 (Using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns, floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
M&L for plain cement concrete (1:2:4) Nominal Mix (using 12.5 mm graded stone aggregate) as in road side kerb, side strip or gola, lacing courses, parapets and railings, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete including demolition of old brick work complete all as specified and directed.
M&L for Brick work with sub-class `B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth complete all as specified and directed.
Dismantling stone slab of any description set in cement mortar complete all as specified and directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc in fair finish surface complete all as specified and directed.
S&F Mild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
S&F in repair floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, 150mm long fixed in floor Complete all as specified and directed.
S&F 35 mm thick IInd class hardwood (teak wood) factory made Plain framed, paneled shutter (any number of panel) and panel of 12 mm thick teak plywood with teakwood grains on both sides faces complete all as specified and directed.
S & F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube complete all as specified and directed.
S & F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified and directed.
S & F MS butt hinges medium weight 100mm long (ISI marked) complete all as specified and directed.
M&L for Ist class hard wood teak plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S & F for butt hinges cast brass with mild steel hinge pin bright polished 100mm long (ISI) complete all as specified and directed.
S&F for 200 mm size brass tower bolt with cast sheet barrel of extruded section fixed with brass screws duty complete all as specified and directed.
S&F for 200 mm size Aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S&F Brass handle 150mm long complete all as specified and directed.
S&F Brass handle 200mm long complete all as specified and directed.
Supply and fixed aluminuium alloy handle fabricated type cast type anodized150mm long complete all as specified and directed.
M&L for 25 mm thick plain cement concrete type B-1 (1:2:4) 20mm graded aggregate as in sub floors etc complete all as specified and directed.
M&L for machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including cutting grinding and mirror finished polshing complete over and including 15mm screed bed in CM 1:6 complete all as specified and directed.
M&L for machine cut kota stone slab as in skirting/dado 18-20 mm thick over cement plaster with grey cement slurry mixed with pigment to match the shade of slab including mirror finished polishing complete including 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for granite stone work 18 to 20 mm thick in steps, jambs, pillars, window cills, cooking platforms and like of any shade for platforms, shelves and flooring laid over and including 20mm thick screed bed in CM (1:6) including pointing in coloured cement in CM (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and directed.
M&L for grinding, cutting & mirror polishing finish to existing marble/kota stone floor etc. complete all as specified and directed
M&L for non Skid ceramic joint less coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc., set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for marble work 18 to 20mm thick of any colour (table rubbed & polished) in steps, jambs, pillars, cills, flooring, shelves and the like over and including 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
S&F for steel cupboard shutters & frames with drawer including cabinet for drawer including open shoe rack (all size/dimension mentioned in drgs),locking arrangements mirror etc as shown on drgs No GE/PN/F/27 dt 9 Aug 2012 Sh ½ & 2/2 as per sample in qtr No SP1/1 (with open shoe rack) frame shall made out of 1.00mm thick M.S sheet. & shutter stiffener, drawers ,cabinet for drawer and open shoe rack made out of 1.00mm thick out of 1mm thick MS. sheet complete fixed with dash fasteners including two coats of anti corrosive paint , over one coat of red oxide primer on the surface in the contact with plaster /concrete, two coats of synthetic enamel paint, teak wood finished and a coat of red oxide primer (colour for outer & inner surfaces as per sample of cup boards and approved by GE), using spray machine on all exposed surfaces internally or externally complete all as specified on drgs and as per sample approved in the block P- 1/1 with open shoe rack all as specified and directed. Note:- One sample will be provided by the contractor for approval by GE before manufacturing in the bulk.
M& L for glazed ceramic tiles in vertical surface, size of tile 375x 250x 7 mm thick/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over and including 10 mm thick backing in CM (1:4) complete all as specified and directed.
S&F looking mirror 5.50 mm thick of size 1.4 x 0.60 mtr to existing frame/board including taking down existing unserviceable mirror from frame and all other accessories complete all as specified and directed.
Supply only Liquid water proofing compound complete all as specified and directed
Taking down of existing sunken slab treatment form the sunken portion and cleaning the surfaces by washing down with water and rubbish off the premises as per following specifications:-
(a) Cleaning and filling crevices, cracks and undulations cement sand mortar mixed with latex polymers such as Dr fixit Pidicrete URP or equivalent in ratio as recommended by manufacturer and then brushing the entire floor and walls of sunken area with neat cement slurry @ 3.00 kg/ sqm and laying 25 mm thick plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) over sunken slab portion and finishing the top surfaces even and smooth without using extra cement .
(b) Provision of 40mm dia PVC pipe spout projection 100mm beyond outer face of the wall of sunken floor to drain out water.
(c) Apply two coats of acrylic cementitious water proofing coating (Dr Fixit pidifin 2K manufactured by M/s Pidilite industries Ltd or equivalent make as approved by GE as per manufacturer recommendations) and followed by a overlay protective layer of 15 mm thick screed/ rendering in CM 1:3 along mixed with liquid water proofing at appropriate ratio of approved make on all surfaces of sunken area after preparations as mentioned above. Method of application for acrylic cementitious water proofing coating shall be followed as per manufacturers instructions.
Hacking out old broken glasses any thickness any size from metal frame including punching or drilling out old glazing pins and fixing new ones complete all as specified and directed.
M&L for sheet glass ordinary quality 3mm thick and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed.
Supply and fix frosted glass 3mm thick complete all as specified and directed.
M&L for preparation of new plaster surfaces on walls and applying a coat of 1.5 to 2 mm thick J K Wall / Birla putty / Asian (Damp block)white cement based wall care putty as per manufacture instructions complete all as specified & directed.
M&L for preparation of old plastered/un-plastered surfaces of wall by brooming down including cornices, pillar etc and applying one coat of white wash on walls complete all as specified and directed.
M&L for preparation of old plastered surface of wall and applying one coat of oil emulsion distemper complete all as specified.
M&L for preparation of new plastered surfaces and applying two coats of oil emulsion distemper (OBD) over a coat of primer complete all as specified and directed.
M/L preparation of old wooden surfaces over 10 cm width or girth including rubbing with sand paper of different sizes including filling thinner with fine cloth and spirit lak dana polishing up to desired finishing as directed by GE
Supply and fixing in repair CP grating 100mm dia and with hole complete all as specified and directed.
Supply and fixing in repair CP towel ring round. Make : Jaquar ESSCO cat No. AEC-1121 or equivalent of make specified in Particular Specification part-II.
Taking up or down steel tubing 15mm dia and connections complete all as specified and directed.
Taking up or down steel tubing 20mm dia and connections complete all as specified and directed.
S&F 15mm bore medium grade galvanized steel tubing (ISI marked) with all fittings (ISI marked) and jointed tested and fixed to wall and ceiling or laid in floor complete all as specified and directed.
S&F 20mm bore medium grade galvanized steel tubing (ISI marked) with all fittings (ISI marked) and jointed tested and fixed to wall and ceiling or laid in floors complete all as specified and directed.
S&F in repair PVC low level flushing cistern 10 Litre capacity syphonic action type white, including ball valve, float valve, handle and bracket complete all as specified and directed.
S&F in repairs vitreous china water closet (pedestal pan) with trap, including connection to drain and to flushing pipe, anti syphonage pipe connections to flushing cistern/pipe complete all as specified and directed including 100mm CI 'P' trap complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed.
M&L for 10 mm thick rendering in CM (1:6) on fare faces of brick wall or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Supply and fixing Chromium plated mild steel piano hinge of 30 mm flap width for cup board/cabinet shutters complete all as specified and directed.
Supply and fixing in repairs looking mirror 5mm thick of size 1.4x 0.60m with aluminum beading mounted on 6 mm thick commercial ply wood and surrounded with aluminium angle compete as directed and approved.
Supply and fixing in repairs wood finished powder coated MS drapery rod 25 to 32mm dia including necessary end brackets, finials and holding arrangement of power coated MS brackets complete all as direct.
S&F in repair 250mm long brass sliding bolt with sand or die cast brass hasp, staple (bolt type) & fixing bolt complete all as specified and directed.
S&F in repair CP brass wall hanger 6 peg set and fixed with screw complete all as specified and directed.
S&F in repair 15mm bore chromium plated basin inlet connection (angle valve) screwed for iron pipe & brass ferrule complete all as specified and directed. Make: ESSCO (Jaquar) cat No.SQT-526KN or equivalent of make specified in Particular Specification part-II.
S&F in repair 15mm Chromium plated basin mixer with U shaped round casted spot with 450mm long braided houses complete all as specified and directed. Make: ESSCO (Jaquar) cat No SQT-516KN or equivalent of make specified in Particular Specification part-II.
S&F in repair 15mm Chromium plated hot & cold wall mixture with, 115mm long bend pipe for connection to over head shower ( with bush and piston diverter fitting) with aerator complete all as specified and directed. Make ESSCO (Jaquar) cat No,SQT-517BKN or equivalent of make specified in Particular Specification part-II.
S&F in repair 15mm bore short body bib tap chromium plated with wall flange and aerator complete all as specified and directed. Make- Jaguar ESSCO cat part No SQT-511KN or equivalent of make specified in Particular Specification part-II.
S & F in repairs PVC down pipe 32 mm dia with CP waste coupling suitable for wash hand basin complete all as specified and directed.
S&F in repair over head shower round shape 100mm dia single flow (ABS body chromium plated with grey face plate) with rabbit cleaning system with including 115mm long shower arm complete all as directed. Make : ESSCO (Jaquar) Cat No. EQS-542N or equivalent of make specified in Particular Specification part-II.
Supply and fixing in repairs vitreous china WHB white oval type 580x400mm size of approved quality on top of platform complete all as specified and directed.
S&F in repair brass chromium plated towel rail 600mm long complete all as specified and directed. Make: ESSCO (Jaquar) Cat No. AEC-1111 or equivalent of make specified in Particular Specification part-II.
S&F in repair brass chromium plated soap dish complete all as specified and directed. Make: ESSCO (Jaquar) Cat No. AEC-1133 or equivalent of make specified in Particular Specification part-II.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out for the following dia of pipe.
S&F for 100 mm bore Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed
All as per item No 75 above but fixed to walls.
S&F for 75mm bore Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed.
S&F for 75mm bore Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall complete all as specified and directed.
S&F for cast iron 75mm diameter of outlet floor trap, with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) complete all as specified and directed
S&F for Cast iron 75mm diameter of outlet Nahani trap , with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1(using 20mm graded crushed stone aggregate) complete all as specified and directed
S&F for 100 mm/75mm bore pipe Stack clamps made out of 50mmX5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed
S&F in repair 15mm bore stainless steel jet spray with 1.00m long PVC tube flexible pipe with two steel check nuts complete all as specified and directed.
S&F in repair 15mm bore 2-way long body bib tap cast copper alloy chromium plated fancy type complete all as specified and directed. Make: ESSCO (Jaquar) cat No. MQT-512ANKN or equivalent of make specified in Particular Specification part-II.
M & L for flat iron as in holdfast fixed to back of chowkats with nails confirming to Fe-290 Gde E-165 complete all as specified and directed.
M & L for PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate for fixing hold fasts using necessary form work complete all as specified.
M & L for preparing wood or wooded based material steel & iron work new or old of any description treated with tar ends of posts, backs of chowkats, etc., area tarred exc 0.1 sq. m but n exc 0.5 sq. m each complete all as specified and directed.
All as per item No 86 above but treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc., area n exc 0.1 sq. m each, complete all as specified and directed.
S&F 600x600mmx4mm thick 'E' board classic factory finish as in false ceiling including supply and fixing 'Tee" grid frame work made of special section of MS galvanized sheet 0.30mm thick, bottom portion painted with cellular nitro painting, consisting angle cleats of size 25mm wide 1.6mm thick with flange fixed to RCC/CGI roofing with dash fastener or wraping the suspending wire around the existing wooden/steel purlin/rafter for suspending grid frame work of size 600mmx600mm suspended with 02 Nos, 1.60mm dia GI wire @ 600mm C/C on main Tee and fixed to T-grid with the help of level clip or as per manufacturer direction. The section consisting of main Tee 37mm x24mmx0.60mm thick, cross runner tee 37mm x24mmx0.60mm and perimeter angle 24mmx 24mmx0.50mm thick shall be fixed to wall with GI screw of 40mm long @ 450mm C/C along the perimeter of wall all as per manufacturer's instruction and including taking down existing boards any thickness including cover fillets etc complete all as specified and directed.
Taking down existing damaged gypsum board false ceiling, S&F new 12mm thick gypsum board on existing grid, smoothening the joint of new & old sheet, applying two coat of oil bound distemper complete all as specified and directed.
M & L for preparation of new wooden surfaces over 10 cm width or girth including rubbing with sand paper of different sizes, filler coat, including filling thinner with fine cloth and spirit lak dana polishing up to desired finishing complete all as specified and directed.
S & F stain less steel telescopic channel of best quality 450mm long fixed to drawer including necessary repair if any complete all as specified and directed..
Taking down carefully existing aluminum/copper surface/concealed point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces in CM 1:3 of walls, floors, ceiling etc including distempering to match with existing surfaces complete all as specified and directed.
M & L for point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FR-LSH having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area drawn in and including PVC conduit concealed and 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor cable FR-LSH as continuous earth conductor, connected to earth dolly by providing suitable lugs with inner and outer frame plate matching with surrounding with sunken steel boxes zinc oxide plated of suitable size for mounting modular switches, sockets etc complete for the following:- Note:- (i) Point wiring & earth wire shall be connected to each & every sunken box. (ii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates. (iii) Modular cover plate with frame and sunken steel boxes zinc oxide plated as per site requirements shall be included in quoted rates.
One light point controlled by one, one way 6 Amp modular switches.
One fan/exhaust fan point controlled by one, one way 6 Amp modular switch.
One 5 pin 5/6 Amps socket outlet point on the same board with other modular switch.
One bell point controlled by one, one way 6 Amp modular switch.
One 5 pin 5/6 Amps socket outlet point on independent board controlled by one, one way modular switch.
All as per item No 93 here in before but point wiring with 2.5 sq mm multi strand copper conductor cable for one five pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sq mm PVC insulated multi strand copper conductor cable as continuous earth wire.
M & L for point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FR-LSH having multi stranded copper conductor of 1.5 Sqmm nominal cross sectional area drawn in existing PVC conduit concealed and 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor cable FR-LSH as continuous earth conductor, connected to earth dolly by providing suitable lugs with inner and outer frame plate matching with surrounding with sunken steel boxes zinc oxide plated of suitable size for mounting modular switches, sockets etc complete for the following:- Note:- (i) Point wiring & earth wire shall be connected to each & every sunken box. (ii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates. (iii) Modular cover plate with frame and sunken steel boxes zinc oxide plated as per site requirements shall be included in quoted rates.
One light point controlled by one, one way 6 Amp modular switch.
One fan/exhaust fan point controlled by one, one way 6 Amp modular switch.
One 5 pin 5/6 Amps socket outlet point on the same board with other modular switch.
One bell point controlled by one, one way 6 Amp modular switch.
One 5 pin 5/6 Amps socket outlet point on independent board controlled by one, one way modular switch.
Description all as per item No 95 here in before but point wiring with 2.5 sq mm multi strand copper conductor cable for one five pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sq mm PVC insulated multi strand copper conductor cable as continuous earth wire .
S&F Modular switch single pole one way 6 Amp complete all as specified and directed.
S&F Modular switch single pole one way 16 Amp complete all as specified and directed.
S&F Modular socket outlet 2/3 pin combined 6 Amp 240 volts complete all as specified and directed.
S&F Modular socket outlet 2/3 pin combined 16 Amp 240 volts complete all as specified and directed.
S&F Fan regulator modular step type 120W 240 volts 2 module type fixed in repair complete all as specified and directed.
S&F Modular bell push flush type, 5 Amps complete all as specified and directed.
S&F Batten holder, PVC/polycarbonate type with back plate suitable for batten fittings fixed in repairs complete all as specified and directed.
S&F in repair switch piano, flush type, single pole one way 5 Amp complete all as specified and directed.
S&F in repair switch piano, flush type, single pole one way 15 Amp complete all as specified and directed.
S&F in repair socket out let, multipurpose, 2 in 1 5 pin, 5 Amp complete all as specified and directed.
S&F in repair socket out let, multipurpose, 2 in 1 5 pin, 15 Amp complete all as specified and directed.
S&F ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate /isolated body complete all as specified and directed.
S&F Wall mounted LED batten fitting, 22 W, 230 volts AC ,T-8, cool white not less than 1200mm extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver with and including 22 W LED tube rod complete and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to walls including taking down existing fitting all as directed. Make:-Havells Cat No-ENDURALINEARNEOBS22WLED840SPCHW or equivalent of make specified in Particular Specification part-II. Note:- Old serviceable light fittings will be deposited to AGE E/M MES store. The quantity of serviceable light will be assessed in the presence of Engineer-in-Charge.
S&F round/square surface mounted LED down lighter 18 watt with powder coated aluminium housing with integrated electronic driver and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to ceiling rose including taking down existing fitting complete all as directed. Make: Havells cat part No. ENDURANEOHESURFACE DDLS18WLED857S or equivalent of make specified in Particular Specification part-II. Note:- Old serviceable light fittings will be deposited to AGE E/M MES store. The quantity of serviceable light will be assessed in the presence of Engineer-in-Charge.
S&F aesthetically designed, 1'x1' cool white flat panel suitable for surface mounting which provide soft-light and glare free symmetrical illumination of fixture size 300x300x70 mm with and including 15 W LED complete, integrated electronic driver and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to ceiling including taking down existing fitting and carefully without damaging existing light fittings and connected items complete all as specified and directed. Make:-Havells, cat No-PLUTOSURFACE1X1PLS15WLED857S or equivalent of make specified in Particular Specification part-II.
S&F LED Study lamp wall mounted type 1 x2 watt LED lamp and all fixing arrangement, connection including taking down existing fitting complete all as directed. Philips Product Code 30975 or equivalent of make specified in Particular Specification part-II.
Wall mounted LED batten fitting, 1 x 10 watt ,230 volts AC,T-5 cool white not less than 581 mm extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver with and including 10 watt LED tube rod etc and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to walls including taking down existing fitting and depositing to E/M store yard all as directed. Make:-Havells,Cat No-ENDURALINEARNEOBS10WLED865SP CWH or equivalent of make specified in Particular Specification part-II. Note:- Old serviceable light fittings will be deposited to AGE E/M MES store. The quantity of serviceable light will be assessed in the presence of Engineer-in-Charge.
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan from site and keeping in safe custody for reuse at site complete as specified and directed by the Engineer- in charge.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete as specified and directed by the Engineer- in charge. Note:- Ceiling fan obtained from taken out shall be reused.
S&F sub main wiring with two single core PVC insulated unsheathed FR-LSH cable 1100 Volt grade, 16 Sq mm size with multi stranded copper conductor drawing into and including 20/25 mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 16 Sq mm FR-LSH cable with multi stranded copper conductor as a earth continuity and connected up to DB including taking down old unserviceable sub main wiring etc complete all as specified and directed. Note: (i) Note:- Four runs of 16 sqmm cable and one run of 16 sqmm cable as earth wire and one run of PVC conduit will be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc.
S&F sub main wiring with two single core PVC insulated unsheathed FR-LSH cable 1100 Volt grade, 10 Sq mm size with multi stranded copper conductor drawing into and including 20/25 mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 10 Sq mm FR-LSH cable with multi stranded copper conductor as a earth continuity and connected up to DB including taking down old unserviceable sub main wiring etc complete all as specified and directed. Note: (i) Four runs of 10 sqmm cable and one run of 10 sqmm cable as earth wire and one run of PVC conduit will be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc.
S&F sub main wiring with two single core PVC insulated unsheathed FR-LSH cable 1100 Volt grade, 6 Sq mm size with multi stranded copper conductor drawing into and including 20/25 mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 6 Sq mm FR-LSH cable with multi stranded copper conductor as a earth continuity and connected up to DB including taking down old unserviceable sub main wiring etc complete all as specified and directed. Note: (i) Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc.
S&F sub main wiring with two single core PVC insulated unsheathed FR-LSH cable 1100 Volt grade, 4 Sq mm size with multi stranded copper conductor drawing into and including 20/25 mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 4 Sq mm FR-LSH cable with multi stranded copper conductor as a earth continuity and connected upto DB including taking down old unserviceable sub main wiring etc complete all as specified and directed. Note: (i) Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc.
Supply and fix in replacement of metal body exhaust fan 300 mm sweep, 900 rpm 230 volts 50 Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc complete all as specified and directed.
S&F in repair MCB DB, sheet metal enclosures double door SPN 4 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter (Metal Door) type with blanking plates where required and IP 43 degree protection complete all as directed.
S&F in repair MCB DB, sheet metal enclosures double door SPN 8 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter (Metal Door) type with blanking plates where required and IP 43 degree protection fixed in repair complete all as directed.
S&F in repair MCB DB, sheet metal enclosures double door SPN 12 way with 200 Amps rated bus bar 240 volts 2 in 1 shutter (Metal Door) type with blanking plates where required and IP 43 degree protection fixed in repair complete all as directed.
S&F distribution boards epoxy powder coated TP & N 8 ways (VTPN MCCB DB) with metal door (IP 43 - IK 09 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and with provision for FP MCB/RCCB/RCBO 63/100 Amps as incomer and 24 SP MCBs or 4/8/ 12 TP MCBs (or any combination of SP/TP MCBs) outgoings complete including disconnecting and taking down existing DB complete all as specified and directed. Make: Legrand, Cat No-5077 32 or equivalent of make specified in Particular Specification part-II. (Note: Suitable RCCB and outgoing MCBs will be measured separately under relevant items of this schedule)
S&F distribution boards epoxy powder coated TP & N 12 ways (VTPN MCCB DB) with metal door (IP 43 - IK 09 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one FP MCCB 100/125 Amps as incomer and 24 SP MCBs or 4/8/ 12 TP MCBs (or any combination of SP/TP MCBs) outgoings complete including disconnecting and taking down existing DB complete all as specified and directed. Make: Legrand,Cat No-5077 48 or equivalent in L&T, ABB (Note: Suitable MCCB and outgoing MCBs will be measured separately under relavant items of this schedule)
S&F MCCB 100 Amps,4 pole 415 volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting having including taking out existing unserviceable MCCB complete all as directed.
S&F MCCB 125 Amps 4 pole 415 volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting having including taking out existing unserviceable MCCB complete all as directed.
S&F Sheet metal enclosure, single pole and neutral with two pin and earth plug and socket with and including one single pole MCB 20 Amps, 240 volts,10 KA complete fixed in repair all as directed.
S&F MCB SP 6 to 32 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete fixed in repair all as directed.
S&F MCB SPN 40 to 63 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete fixed in repair all as directed.
S&F MCB TPN 100 Amps, 415 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete all as directed.
S&F RCCB/RCBOs TPN 100 Amps, 415 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete all as directed
Supply and fix in replacement of Water heater (Geyser) storage type, electric, capacity 25 litres. five star rated AC SP 230 volts, 50 Hz, vertical mount type, shockproof and rustproof metal body, stainless steel inner container, high efficiency heating element, auto cut thermo state, pressure release safety system, fire retardant cable with 3 pin plug top, white colour including fixing accessories like fasteners, nuts, washers complete all as specified and directed. Make: Havells cat part No. GHWAMGTWH025 or equivalent of make specified in Particular Specification part-II.
Supply and fix in replacement LED lamp 15 watt 230 volts complete as specified and directed by the Engineer- in charge.
Taking down unserviceable storage type electric water heater (Geysers) after isolating electric and water supply of capacity 50 litres from site for de scaling the inner container with cleaning solution including re fixing in same position complete all as specified and directed.
Taking down un serviceable storage type electric water heater (Geysers) from site of capacity 25/35/50 ltr for necessary repair of inner tank water leakage with stainless steel welding and re fixing in same position or where directed and testing complete all as specified and directed.
S&F Stainless steel inner container (tank) of capacity 50 litres as per sample including taking down old unserviceable tank and testing complete all as specified and directed.
S&F Outer container for 50 litres tank capacity geyser as per sample including taking down old unserviceable outer cover and testing complete all as specified and directed.
S&F heating element 3 KW 230 volt, ISI marked, round /triangular type as per sample for storage type electric water heater including taking down existing unserviceable element complete all as specified and directed.
S&F indicating lamp 230 volt AC for geyser as per sample of Green & Red colour complete all as specified and directed.
S&F heavy duty PVC connection with 15 mm dia 450 mm long with CP brass nuts and leads PVC washer 02 Nos on each ends for geyser connection complete all as specified and directed.
S&F heavy duty PVC connection with 15 mm dia 600 mm long with CP brass nuts and leads PVC washer 02 Nos on each ends for geyser connection complete all as specified and directed.
S&F thermostat switch 220- 240 volt 16 Amp 0-75° /80° C ISI marked as per sample suitable for round/triangle type element and including taking down existing complete all as directed.
S&F metallic fastener screw 75mm long 6mm dia with bolt for hanging Geyser, complete all as directed.
S&F flexible copper cable of size 23/0.0076 with PVC insulated 2 core twisted 660 volts grade including taking down existing cable complete all as directed.
S&F PVC insulated and sheathed cable 03 core 2.5 sqmm stranded copper conductor fixed in repair complete all as specified and directed.
S&F multifunction safety valve cast copper alloy 15 mm dia ISI marked complete including taking down existing valve all as directed.
S&F non return valves cast copper alloy ISI mark 15 mm dia as per sample complete including taking down existing NRV all as specified and directed.
S&F stainless steel chromium plated assembly as per sample complete suitable for water heater of any make and capacity 50 complete including taking down existing assembly complete all as specified and directed.
Metal clad Industrial plug top ISI mark 3 pin 20 Amps with earth 250 Volts including taking down old one complete as specified and directed.
Supply and fix in replacement of ceiling fan 1200 mm sweep, 230 volts 50 Hz, energy saving model single phase, copper wound motor, five star, pearl white in colour complete with blade, down rod , canopy and connected with ceiling rose etc complete all as specified and directed.
Material and labour for earthing with galvanised steel earth plate electrode 60cmX60cmX 6mm thick buried directly in ground (earth pit not less than2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm thick GI wire by means of nuts, bolts, check nuts & washers of galvanized iron or steel, protected by 15mm bore light grade galvanised iron pipe and connected to main switch board, including all necessary excavation & earth work in hard dense soil including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternate layers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover10mm thick hinged to CI frame and 6mm MS rod for handle and necessary testing complete all as shown in electrical plate No 3 of SSR part-I all as specified and directed.
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. as required 4 mm dia galvanised iron or steel wire
Meher enterprises
ACE BUILDERS AND CONTRACTORS
M/S S P BUILDERS
Bhanu Prakash
M R Taders
OM TRADERS
M/S C S AITHANI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .