Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Fully strengthen the air heater plates and conduct a satisfactory trial; Buyer
Repair
Maintenance
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling the old air heater tubes of Boiler No 01 size 63 5 mm OD x 2 64 mm thickness fabricating and errecting new tubes in accordance with the dra..
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling the old air heater tubes of Boiler No 02 size 63 5 mm OD x 2 64 mm thickness fabricating and errecting new tubes in accordance with the dra..
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Dismantling the old air heater tubes of Boiler No 03 size 63 5 mm OD x 2 64 mm thickness fabricating and errecting new tubes in accordance with the dra..
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; a Dismantling old columns beam channels etc B Manufacturing and installing new columns beam channels; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Installing 16 inch 18 inch manholes with blinds; Buyer
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Constructing a bed for the pump fitting the pump and motor and conducting a trial run of up to Twenty HP; Buyer
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting weak corroded pipe lines up to 12 and providing satisfactory leak proof trials; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting weak corroded tees up to 12 and providing satisfactory leak proof trials; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting weak corroded nipples up to 12 and providing satisfactory leak proof trials; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting a weak throated cross member up to 12 and providing satisfactory leak proof trials; Buyer
and Installation of Plant Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting a weak throated band up to 12 and providing satisfactory leak proof trials; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting a weak throated flange up to 12 and providing satisfactory leak proof trials; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Dismantling fabricating and erecting a weak sloping reducer up to 12 and providing a satisfactory leak proof trial; Buyer
and Installation of Plant/Systems/Equipments (Version 2) - Industry Unit; Removing the old corroded platform and replacing it with a new one; Buyer