Loading…
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹28.5 L
EMD Value
₹57,036
Closing Date
28 Oct 2026, 3:00 pmDue tomorrow
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
EE/ELD-12, DDA
O/o EE/ELD-12, DDA Paschim Vihar, New Delhi-110063.
Supplying and Replacement of Feeder Pillar of Lighting Network and Pump etc. in various Parks/Green Belts under HD-2, Horticulture Zone.
2026_DDA_931307_1
49/EE(E)/ELD-12/DDA/2026-27
Open Tender
Electrical Works
Percentage
60 days
Horticulture Division
as per tender notice
11 documents required · 11 mandatory
₹0
₹57,036
Yes
22 Oct 2026
22 Oct 2026
29 Oct 2026
22 Oct 2026
28 Oct 2026
22 Oct 2026
22 Oct 2026 - 28 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and Replacement of Floor Mounted (Light Panel) LT Feeder Pillar Cubical type Double Door of size 1000 (H) mm x 900 mm (W) x 300 mm (D) duly compartmentalized and with general arrangement made out of 2.5 mm thick (12 Gauge) CRCA Sheet having hinged gasket covers and screwed knobs with double locking arrangement & Locking Hooks and separate Rain Protection Covers with extension of 100 mm in Width & Depth and supported with MS Angle Iron legs and Bottom Frame of size 40 mm x 40 mm x 6 mm x 1 mtr. long grouted with 1:3:6 CC Foundation and should be 0.7 mtr. above Ground Level. Legs should be open, connections, inter-connections with suitable size of FRLS PVC Insulated Copper Conductor using thimbles, ferrules wherever required, Painting with Primer, Numbering, Identification Plate of Component embossed and/or printed in Metal including Supply & Fixing of following accessories complete etc. as required (as per drawing approved by Engineer-in-Charge) including rebate for dismantle material.
a) 125 A, 36 kA Ics=100% Icu and Operational Voltage 690 V, 4 Pole MCCB- 1 No. (Incomer).
b) 6 A to 32 A ratings, SP MCB, “C” curve, 10 KA breaking capacity- 4 Nos.
c) 6 A to 32 A ratings, DP MCB, “C” curve, 10 KA breaking capacity- 4 Nos.
d) 63 A, FP MCB, “C” curve, 10 KA breaking capacity- 1 No.
e) Electronic/Analogue Timer of model FM1/Quartz Daily 110 VAC-240 VAC Base/DIN Mounting in the Panel with Toggle Switch for Auto/Manual- 1 No.
f) 3-Pole Power Contactor of AC3 Rating 40 Amp, MNX 40 type- 1 No.
g) Voltmeter (0-500 V) 96 mm x 96 mm Square type with Selector Switch- 1 No.
h) Ammeter (0-30 A) 96 mm x 96 mm Square type- 1 No.
i) Phase Indication Lamp (RYB) with Fuses- 1 Set.
j) 200 mm x 150 mm MV Danger Notice Plate of 2 mm thickness- 1 No.
k) 150 A, 4-Strip Al. Bus-Bar of minimum 400 mm long and of size 30 mm x 5 mm with sleeve and nut-bolts- 1 Set.
l) 30 Amp, 4-Way Neutral Link/Connector- 2 Nos.
m) Lamp Holder for Lighting arrangement inside Feeder Pillar- 1 No.
n) Earthing Stud- 2 Nos.
o) Lifting Hook on the Top of Feeder Pillar- 2 Nos. | 25 | Set | 46,923 | ₹11,73,075 |
| 2 | Supplying and Replacement of Floor Mounted (Pump Panel) LT Feeder Pillar Double Door of size 1000 (H) mm x 900 mm (W) x 300 mm (D) duly compartmentalized and with general arrangement made out of 2.5 mm thick (12 Gauge) CRCA Sheet having hinged gasket covers and screwed knobs with double locking arrangement & Locking Hooks and separate Rain Protection Covers with extension of 100 mm in Width & Depth and supported with MS Angle Iron legs and Bottom Frame of size 40 mm x 40 mm x 6 mm x 1 mtr. long grouted with 1:3:6 CC Foundation and should be 0.7 mtr. above Ground Level. Legs should be open, connections, inter-connections with suitable size of FRLS PVC Insulated Copper Conductor using thimbles, ferrules wherever required, Painting with Primer, Numbering, Identification Plate of Component embossed and/or printed in Metal including Supply & Fixing of following accessories complete etc. as required (as per drawing approved by Engineer-in-Charge) including rebate for dismantle material.
a) 125 A, 36 kA Ics=100% Icu and Operational Voltage 690 V, 4 Pole MCCB- 1 No. (Incomer).
b) 6 A to 32 A ratings, SP MCB, “C” curve, 10 KA breaking capacity- 2 Nos.
c) 6 A to 32 A ratings, DP MCB, “C” curve, 10 KA breaking capacity- 3 Nos.
d) 63 A, FP MCB, “C” curve, 10 KA breaking capacity- 1 No.
e) 3-Phase Submersible Pump Controller (MU-G7.5) with Single Phase Preventer up to 7.5 Hp Pump Set, Relay Range 13 to 22 Amp- 1 Set.
f) Electronic/Analogue Timer of model FM1/Quartz Daily 110 VAC-240 VAC Base/DIN Mounting in the Panel with Toggle Switch for Auto/Manual- 1 No.
g) 3-Pole Power Contactor of AC3 Rating 32 Amp, MNX 32 type- 1 No.
h) Voltmeter (0-500 V) 96 mm x 96 mm Square type with Selector Switch- 1 No.
i) Ammeter (0-30 A) 96 mm x 96 mm Square type- 1 No.
j) Phase Indication Lamp (RYB) with Fuses- 1 Set.
k) 200 mm x 150 mm MV Danger Notice Plate of 2 mm thickness- 1 No.
l) 150 A, 4-Strip Al. Bus-Bar of minimum 400 mm long and of size 30 mm x 5 mm with sleeve and nut-bolts- 1 Set.
m) 30 Amp, 4-Way Neutral Link/Connector- 2 Nos.
n) Lamp Holder for Lighting arrangement inside Feeder Pillar- 1 No.
o) Earthing Stud- 2 Nos.
p) Lifting Hook on the Top of Panel Board- 2 Nos. | 20 | Set | 55,456 | ₹11,09,120 |
| 3 | Supplying, Fabrication and Replacement of Wire Mesh Protection Frame for Existing Feeder Pillar, constructed from 8 SWG MS wire mesh with a Nominal size of 75 mm x 25 mm Rectangle. The Frame dimensions are 1.5 mtr. (Width) x 1.00 mtr. (Depth) x 2.00 mtr. (Height). It includes a Base Frame made of 40 mm x 40 mm x 6 mm MS Angle Iron, MS Strip Supports of 40 mm x 6 mm, and 0.5-meter-long leg supports of the same Angle Iron, all as per the approved drawing. Additionally, provide a suitably sized door, Supply and Fix a godown lock with locking arrangement, painting, and grouting with 1:2:4 Cement Concrete Foundation, as approved by the Engineer-in-Charge, complete as required including rebate for dismantle material. | 10 | Each | 23,313 | ₹2,33,130 |
| 4 | Supplying of following sizes of XLPE (Cross Linked Poly Ethylene) Insulated PVC Sheathed Alumimium Conductor Armoured Power Cable of 1.1 KV grade including connection, testing etc. as required including rebate for dismantle material.
2C x 16 sq. mm | 180 | Meter | 192 | ₹34,560 |
| 4.01 | 4C x 25 sq. mm | 180 | Meter | 333 | ₹59,940 |
| 5 | Laying of one number PVC Insulated and PVC Sheathed/XLPE Power Cable of 1.1 KV grade of following size in the Existing RCC/HUME/METAL Pipe as required.
Up to 35 sq. mm | 360 | Meter | 47 | ₹16,920 |
| 6 | Supplying and Laying of following size DWC HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS: 14930, Part-II complete with fitting and cutting, jointing etc. direct-in-ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia. (OD-63 mm & ID-51 mm nominal) | 340 | Meter | 289 | ₹98,260 |
| 7 | Earthing with GI Earth Pipe 4.5 meter long, 40 mm dia. including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required including rebate for dismantle material. | 16 | Set | 6,892 | ₹1,10,272 |
| 8 | Providing and Fixing 25 mm x 5 mm GI Strip on surface or in recess for connection etc. as required including rebate for dismantle material. | 64 | Meter | 258 | ₹16,512 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.12 MB
NIT49.pdf
Tender Documents • 1.41 MB
BOQ_978650.xls
BOQ • 0.26 MB
PressNoticeNIT49.pdf
Additional Documents • 2.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .