Loading…
Loading…
Tender Value
₹84.4 L
EMD Value
₹1.7 L
Closing Date
21 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKS 2
14 conditions · 3 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or "V" whichever is less; Where V=Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Electrical contractor license: - The contractor should have valid electrical contractor license issued by government and submit along with tender document. If valid electrical contractor license is not submitted along with tender document, then offer will be summarily rejected.
Technical Eligibility Criteria: (a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. The Definition of similar nature in this tender means "Any Electrical work related to HT/LT installations". (Authority: PCEE / NWR / JP letter No EL/50/0/SNW/Vol.I Dtd. 08.01.2016).
3 conditions · 1 needing a document upload
Bidder / Tenderer should submit GST registration certificate along with PAN card & Bank mandate while bidding / uploading tender documents
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
I / We have visited the works site and I / We am / are aware of the site conditions.
(i) Electrical work in connection with Extension of Sick line Shed at Coach Care Complex Jodhpur (ii) Electrical work in connection with Essential infrastructure facilities required for C&W at Merta Road (iii) Electrical work in connection with provision of new drop pit table with development of under frame related infrastructure in BGKT diesel shed.
25of2026-27~NWR
25of2026-27
Open
Works - General
12 Months
Jodhpur, Rajasthan
₹0
₹1.7 L
29 Sept 2026
29 Sept 2026
7 Oct 2026
109 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 84,36,883.96 | ||
| — | 1350.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x6 sq mm PVC insulated multi-strand ( 84 /.30 mm ) copper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm. as per specifications attached as required. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,66,819.5 | |
| — | 1700.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x4 sq mm PVC insulated multi-strand ( 56 /0.3 mm ) cooper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm. as per specifications attached as required. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,48,665 | |
| — | 2650.00 | — | — | ||
| Supply of material & wiring of sub-main with 2x2.5 sq mm PVC insulated ( 36 /0.3 mm ) multi-strand copper conductor cable in existing laid ( surface / recessed ) PVC conduit pipe and continuous running of PVC insulated copper earth wire of 1 Sq.mm. as per specifications attached as required (Inspection- Consignee , Inspection Charges - Nil | — | — | — | 1,82,002 | |
| — | 680.00 | — | — | ||
| Supply and Fixing of 20 mm dia medium class P.V.C. Pipe along with accessories as required in recess on walls/roof properly including cutting of wall /roof and making good the damages as per specifications attached. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 54,372.8 | |
| — | 2320.00 | — | — | ||
| Supply and Fixing of 20 mm dia medium class PVC Pipe along with accessories as required in surface on walls/roof properly with saddles and wooden gutties etc. complete as per specifications attached. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,21,544.8 | |
| — | 65.00 | — | — | ||
| Supply, install, test commission of 8Moduler metal flush box with suitable size cover &base frame as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 24,804.65 | |
| — | 43.00 | — | — | ||
| Supply, install, test commission of 4Moduler metal flush boxwith suitable size cover &base frame as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 12,369.38 | |
| — | 20.00 | — | — | ||
| Supply, install, test commission of 3Moduler metal flush box with suitable size cover &base frame as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 4,379.4 | |
| — | 22.00 | — | — | ||
| Supply, install, test &commission of 2 Modular metal flush box with suitable size cover &base frame as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 3,996.3 | |
| — | 75.00 | — | — | ||
| Supply, install, test &commission of Modular6amp, 5 Pin Socket asper specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 10,044.75 | |
| — | 95.00 | — | — | ||
| Supply, install, test commission of Modular6amp one way/SPSwitch, ISI marked asper specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 6,665.2 | |
| — | 40.00 | — | — | ||
| Supply, install, test commissioning of Modular 16 amp, 3/3(6Pin) Socket as per specification(Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 8,618.8 | |
| — | 40.00 | — | — | ||
| Supply, install, test commission ofModular16 amp one way/SP Switch , 2 Modular ,ISI marked including connection / wiring on lighting switch board asper specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 5,910 | |
| — | 52.00 | — | — | ||
| Supply, install, test &commission of Modular blank plate as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 646.88 | |
| — | 28.00 | — | — | ||
| Supply, install, test commission of Modular type Fan regulator (5step , 2 Modular)including connection/wiring on lighting switchboard as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 13,970.88 | |
| — | 350.00 | — | — | ||
| Recessed/Surface conduit wiring system-Supply of material and wiring of LP/TP/FP/Exhaust fan/ Bellpoint with single core multistrand copper conductor size 1.5 Sq.mm in PVC conduit pipe with 5/6 Amp modular type switch/ceiling rose/batten holder etc. As per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,45,691 | |
| — | 19.00 | — | — | ||
| Supply, testing, fixing &commissioning of Exhaust fan 200-300 mm sweep 1200-1440 RPM speed and as per specification attached. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 43,217.97 | |
| — | 520.00 | — | — | ||
| Supply of material & commissioning of PVC casing caping 25X12 mm with accessories for surface wiring as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 12,714 | |
| — | 6.00 | — | — | ||
| Supply, fixing, testing and commissioning of fabricated Feeder Pillar distribution box made of MS sheet 1.6mmthick size 600x300x600mmwith suitable MS stand Copper bus bar of 200Acapacity and 2x63A MCB 4pole as per spec (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 34,552.98 | |
| — | 190.00 | — | — | ||
| Assembling, fixing, hanging and making connection of Surface pendent mounted box type tube light fitting/street light fitting as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 13,680 | |
| — | 7.00 | — | — | ||
| Supply, fixing, testing and commissioning of VTPN DB 8-way enclosure with provision of incoming MCCB of 125A,IP 43/IK09, double door at suitable locations. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,07,932.86 | |
| — | 7.00 | — | — | ||
| Supply, Fixing of MCCB to be provided in the VTPN given above including supply of material as required & as per specifications attached- MCCB 4-pole 100/125A, 25 KA (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 97,187.3 | |
| — | 192.00 | — | — | ||
| Supply, Fixing of MCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached-MCB (SP-) 6-32 A (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 46,156.8 | |
| — | 24.00 | — | — | ||
| Supply, Fixing of RCCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached-RCCB - 25 A/30mA twp pole (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 60,828.72 | |
| — | 20.00 | — | — | ||
| Supply, Fixing of MCB TP 63A to be provided in the MCB DB including supply of material as required & as per specifications attached (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 41,737.2 | |
| — | 24.00 | — | — | ||
| Supply. fixing, testing and commissioning of SPN DB 8-way with provision of incoming MCB of 63A,IP 43/IK09, double door at suitable locations. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 61,512.72 | |
| — | 20.00 | — | — | ||
| Supply, Fixing of MCB to be provided in the MCBDB given above including supply of material as required & as per specifications attached-MCB(TPN)-63A (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 42,056.8 | |
| — | 8.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 63A,RCBO Four pole, 30mA with Earth leakage, overload and short circuit protection as per spec (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 28,826.56 | |
| — | 20.00 | — | — | ||
| Supply, install, test & commission of Ray roll plug socket 20amp SPN Ray Roll Plug socket including connection /wiring of "C" series 32 amps SP-MCB as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 17,917.8 | |
| — | 6.00 | — | — | ||
| "B" Class 50 mm dia GI pipe earth Station with digging pit & refilling with charcoal & salt as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 8,309.1 | |
| — | 6.00 | — | — | ||
| Inspection Chamber with cover as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 2,313.78 | |
| — | 60.00 | — | — | ||
| Supply & laying of earth connection from earth electrode with 4 mm GI wire properly fixed on wall with wooden gutties etc. as required. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 703.2 | |
| — | 14.00 | — | — | ||
| Supply and providing copper plate earthing 4.0 m deep size 600x600x3mm with 3.5m long G.I. "B" class pipe 38 mm for pouring water with 50 Kg charcoal and 10 Kg salt including RCC/masonry earth enclosure with pull out handle and 25x3 mm copper flat earth strip 4.0 mtrs long from earth pit bottom riveted to earth top . The earth value to be measured and marked on earth pit and as per specification attached. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,22,725.12 | |
| — | 140.00 | — | — | ||
| Supply and fixing copper earth strip 25x3 mm and as per specification attached. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 59,357.2 | |
| — | 4500.00 | — | — | ||
| Digging and filling of trench size 0.4 x 0.8 mtr as per spec ( trench work may be on kuchcha/ pucca land and all type of soil as per site requirement and without protective layer of brick). Surface of trench shall be made good in all respect and satisfaction of site engineer. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 1,83,105 | |
| — | 700.00 | — | — | ||
| laying cable in Air/Wall/Pole etc with fixture(02 nos. per mtrs) as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 17,024 | |
| — | 5000.00 | — | — | ||
| Supply and laying of HDPE pipe confirming to IS 4984:1995, 50 mm dia, wall thickness 3 mm, PN 6 under the road. The work involves laying of HDPE pipe and also laying cable in it as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 4,93,100 | |
| — | 2000.00 | — | — | ||
| Supply & laying of HDPE pipe of 75/80mmdia, PN4, PE63 . The work involves laying of cable in HDPE pipe as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 2,41,000 | |
| — | 1680.00 | — | — | ||
| Drilling of horizontal bore below track/road by pushing method for laying of RCC/HDPE/DWC pipe of various sizes (As per specifications) (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 23,92,756.8 | |
| — | 1680.00 | — | — | ||
| Supply & laying of HDPE pipe, dia 160 mm under road/ground/floor/railway track or as per site requirement in already excavated trench. (As per specification) (Inspection- RITES , Inspection Charges - To be borne by Railway) | — | — | — | 13,27,922.4 | |
| — | 61.00 | — | — | ||
| Supplying., laying of GI pipe size 50 mm dia. B class as per IS1239 for cable use as per specification enclosed (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 20,988.88 | |
| — | 2.00 | — | — | ||
| L.T. Panel-I Manufacturing, supplying, testing and commissioning of wall/floor mounted (as per site requirement) LT Distribution board with 01 No. 200 Amp. 4 pole 415 Volt, 50 Hz, thermal magnetic MCCB as incoming and 02 No.100 Amp. 4 pole MCCB, 03 Nos. 40 Amp. 4 pole MCCB as outgoing. .(As per Specification attached) (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 2,43,366.56 | |
| — | 390.00 | — | — | ||
| Supply installation of PVC Cable duct A45(H)x45(W) along with duct cover A45 in length of 1 meter standard Slot Grey of M/s L&T, Phoneix, Panduit or similar make (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 49,701.6 | |
| — | 700.00 | — | — | ||
| Supply, installation, testing & commissioning of (100 mm width x 50 mm depth x 1.6 mm thickness) perforated Hot Dipped Galvanized Iron Cable Tray (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections fixed with MS Angle frame duly painted of 35 mm x 5 mm thick and all hardware complete in all respect (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 4,54,300 | |
| — | 220.00 | — | — | ||
| Supply of material and wiring of shed TP/FP with 1.5 sq mm single core multi- stranded copper wire PVC insulated in conduit 1.5mm thick 19mm size white colour shall be fixed with junction box TEE and 1.5minsq PVC CU cable insulated multi stranded for earth wire and 5/6A,ceiling rose. The conduit shall be fixed with raw plugs/ tied including connection as per spec. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 27,816.8 | |
| — | 120.00 | — | — | ||
| Supply and fixing of PVC cable duct 40 x 60 (w x h) 1 M STD slot greenish gray of standard make as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 13,184.4 | |
| — | 120.00 | — | — | ||
| Supply, drawing, testing and commissioning of PVC copper wire 6 sqmm as per specification (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 4,465.2 | |
| — | 4.00 | — | — | ||
| Supply, erection, testing and commissioning of pre-cooling points having BCH 500 volt 63 A plug switch unit combined set (male-female both) including aluminium four pole bus bar chamber of 250 Amps capacity complete inside MS enclosure having suitable design for incoming and outgoing 3 ½ core 120 sq. mm XLPE cable with earthing of the pre-cooling point as per the detailed technical specification and site requirement this item includes the supply of 63 amp. MCCB 4pole. size of MS box 450 mm (W) x 600 mm (H) x 330 mm (D) as per site requirement and drawing. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 73,284 | |
| — | 9.00 | — | — | ||
| J' type cable route marker made of cast iron as per approved Railway drawing. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 2,009.97 | |
| — | 4.00 | — | — | ||
| Supply, Install, test & Commission of outdoor type Junction Box with Aluminium bus bar (Size-40X10) as per specification. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 25,425.52 | |
| — | 6.00 | — | — | ||
| Supply & Installation of OHE Power Presence/Absence Indicator with Hooter Each set Consisting of (i) Sensor mount with guard qty=01 No.(ii) Sealed Sensor qty = 01 No.(iii) Connecting Cable of Length 5 Meter qty = 01 No. (iV) Display cum power Supply unit for indication of power on off & Sensor failure with working input voltage 180 250 V AC qty = 01No. ( V) power Connecting cable with 3 Pin connector at one & 3 pin Socket at other and qty =01 No. (Vi) Hooter Qty = 01 No. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 4,31,172 | |
| — | 8.00 | — | — | ||
| Supply, fixing, testing and connecting of wall mounted heavy duty Air Circulator of 24''(600mm) size with built in 3 speed regulator, delivers Air 280Cu.m/min, similar to M/s Almonard make with all accessories complete confirming to IS specification with latest amendments. The Air Circulator is to be fixed by suitable MS clamps of size 50x50x6mm / flats of size 40x6mm with bolts and nuts etc., complete as desired by site engineer. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 78,568.88 | |
| — | 50.00 | — | — | ||
| Supply of material, fabrication, installation and commissioning of Rolling in Examination lighting MS box of suitable dimensions as per specifications attached at specified locations. (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 3,03,504.5 | |
| — | 1.00 | — | — | ||
| Supply, installation ,testing & commissioning of MDB with three phase electronic Energy meter, digital ampere meter with CT, selector switch, suitable digital voltmeter and indication lamp with following incoming & outgoing Incoming- MCCB 4 pole 400A,35KA 2 Nos. Outgoing- MCCB 4 pole 250A,35KA-06Nos as per spec (Inspection- Consignee , Inspection Charges - Nil ) | — | — | — | 3,41,956 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ACS1TO12newCOMPRESSED.pdf ACS01to12of GCC2022
ATTACHMENT
TD25of26-27.pdf
ATTACHMENT
SORclubbedNIT25of26-27.pdf
ATTACHMENT
ACS1TO12newCOMPRESSED.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .