Loading…
Loading…
3,078 results • Best match
Installing one additional outdoor unit of 20 HP in existing 60 HP VRF System and recommissioning the VRF Type Air Conditioning System installed in the M.P.S.J.A. Jabalpur.
Replacement of blue star make old reciprocating chillers with new EEF green screw chillers for air conditioning system of VFD room of 1x500 MW SGTPS MPPGCL Birsinghpur.
Annual maintenance contract for 02 nos. air conditioning fitted in operator cabin of PC2000-8 hydraulic shovel of Jayant Project for period of one year(365 days).
Annual maintenance contract for maintenance of air conditioning system of 01 no Komatsu D475A-5EO dozer sl.no 30204 and Komatsu Wheel dozer sl.no 50453 at Jayant Project.
Annual Maintenance contract for maintenance of DTAC Air conditioning system of operator cabin of BEML Equipment i.e. 09 nos BD355 Dozers for a period of 01 year.
Annual Maintenance Contract for maintenance and repair of Air Conditioning system fitted in Operator cabin of Komatsu D475A Dozer Sl no T-30266 at NWS Nigahi Project.
Annual maintenance contract for maintenance of air conditioning system of operator cabin in 06 Nos. BWS-70KL water sprinkler for the period of one year (365 days).
AMC of operation and maintenance of Central Air Conditioning Plant installed at Sanjay Gandhi Memorial Hospital at S.S. Medical College Rewa (M.P.) (For One Year) SECOND CALL
Facility Management Services - LumpSum Based - Hospitality; servicing of a commercial centralized air- conditioning ducted cooling system; Consumables to be provided by service provider (inclusive in contract cost)
Procurement of spares and refrigerant gas for Split AC and HVAC System installed at SWAS System and main TG Building at 2x600MW SSTPP, MPPGC, Dongalia
CERTAIN REPAIR MAINT OF DEEP FREEZER, WATER COOLER, WINDOW SPLIT AC ETC IN ZONE B AND C AREA UNDER AGE EM OF GE (EAST) JABALPUR
E/I of Split AC for District Judge Court room, ADJ court room, Special Judge court room and Rest Room for Various Courts District Ratlam.
Supply, erection and installation of Industrial Grade split AC in CAAQMS , UPS room and pollution control monitoring room of 210 MW Unit, ATPS, MPPGCL, Chachai.
Fitment of new split AC inplace of window type AC in operator cabin of both 24 96 Dragline KRISHNA AND BALRAM working at Nigahi Project.
For Providing Comprehensive Maintenance and Servicing of Air-Conditioners (Split Type, Window Type and Cassette Type) at EinC office P.W.D. Nirman Bhawan, Bhopal (For the Year 2023-24, 2024-25 and 2025-26)
PROVIDING ANNUAL COMPREHENSIVE MAINTENANCE CONTRACT (C MC) OF WINDOW TYPE SPLIT TYPE , AND DUCT ABLE AIR CONDITIONERS INSTALLED AT STATE INFORMATION COMMISSION BUILDING ARERA HILLS BHOPAL (FOR ONE YEAR 2020-21)
PROVIDING ZONAL TENDER FOR INSTALLATION SHIFTING, SERVICING REPAIRING OF ALL TYPE AIR CONDITIONERS INSTALLED IN VIP BUILDING / GOVT. BUILDINGS AND ELECTRICAL WORK AS REQUIRED UNDER E/M DIVISION JABALPUR DISTT. JABLPUR.
Annual maintenance contract (AMC) for maintenance of Window/split air conditioners, water coolers, refrigerators, installed at different establishment of NCL HQ. Singrauli for Two years including supply of spares / consumables / materials
Custom Bid for Services - Biennial Job Contract for maintenance of air conditioners water coolers refrigerators deep freezers and geysers in VSTPS Township Similar Category Operation and Maintenance Power House/Power Plant
Air Conditioner Air Conditioner ( 5 ) Technical Specifications Specification Specification Name Values Allowed Values CAPACITY/GENERIC Type of Air conditioner High wall Split AC highwallsplitac Technology of AC Non- Inverter (Fixed Speed) non- inverter(fixedspeed) Nominal cooling capacity in Ton (kcal/hr) 1.5 Ton/4500 kcal/hr 1.5ton4500kcalhr Coil Material Copper copper Eco-friendly refrigerant true N/A Minimum length of copper pipe and suitable connecting electrical cable for installation and commissioning 3 metre N/A Packing LIst na N/A Any other Features na N/A CONFORMITY CERTIFICATION BEE Star Rating 5 5 Conformity to Indian Standard IS 1391 latest N/A ISI Marked true N/A CM/L No (BIS License No) 0.0 N/A 1/4 WARRANTY Warranty on Machine 1.0 1, 2, 3, 4, 5 Warranty on Compressor 5.0 N/A INSTALLATION Installation and commissioning With Installation and Commissioning withinstallationandcom missioning * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anand Kumar Pandey 480447, Regional Stores, WCL Pench Area P.O CHANDAMETA Distt. Chhindwara, M.P 480447 5 25 EMD Required No ePBG Required No
For Providing Supplying, Installation and Testing of Air-Conditioning with Electrification and Supply Cables at Institute of State Agriculture Extension and Trainning , Barkhedi Bhopal (MP).
Supply, installation, testing and commissioning of Water Cooler and Water Purifier and Air Conditioner at Zone No. 01, Ward No. 05, Bhopal. Third Call
PROVIDING FOR AMC (ANNUAL MAINTENANCE COMPREHENSIVE) OF 25 Nos. OLD SPLIT TYPE AIR CONDITIONER (EACH 2TRFOR 2 YEARS) AT CIVIL COURT KATNI DISTT. KATNI.
ANNUAL REPAIRING AND 3 (THREE) YEARS MAINTENANCE OF AIR CONDITIONER, WATER COOLER AT IDA BUILDING AND STAFF BANGLOW NO.1 AND 2 IDA INDORE
Repairing or Servicing of Split or Window Air Conditioner installed in Upper Rest House, Erector Hostel, CE Office and other offices of STPS, Sarni.
SUPPLY, INSTALLATION, TESTING, COMMISSIONING OF VRV VRF AIR CONDITIONER AND AUDIO SYSTEMS INCLUDING 03 YEARS COMPREHENSIVE MAINTENANCE WITH SPARES AT PRITAMLAL DUA SABHAGRAH INDORE
Procurement of 04 no. of Air Conditioner of 5 star rating and 2 Ton capacity each in the office hall at MHPS MPPGCL Shivpuri
PROV AND FIXING OF DEFFECTIVE MCB DBS AND MCB MCCB AND CABLE FOR AIR CONDITIONER UNIT AT TREASURY AND ACCOUNT OFFFICE PARYAWAS BHAWAN BHOPAL
Hiring of 01 No New LMV vehicle with Air Conditioner for official use with maintenance work at various EHV substation under Testing DN Chhindwara
INSTALLATION OF AIR CONDITIONER UNITS WORK AT MRIGNAYANI EMPORIUM, B-8, STATE EMPORIA COMPLEX, BABA KHARAK SINGH MARG, NEW DELHI (UNDERTAKING GOVT. OF M.P.)
Annual maintenance contract for repair and maintenance of Plant type Air Conditioner system fitted in 01 number REL850E Drill working at Nigahi Project, NCL.
Annual maintenance contract for repair and maintenance of Plant type Air Conditioner system fitted in 01 number REL850E Drill working at Nigahi Project, NCL.
REPAIRING AND TWO YEARS MAINTENANCE OF INTERNAL ELECTRIFICATION AND SPLIT TYPE WALL MOUNTED AIR CONDITIONING WORK AT SCHEME NO. 54 CHAIRMAN / CEO BUNGLOW NO. 1 AND 2 INDORE
Operation and Maintenance contract of HVAC system of 600MW Air conditioning Main Plant, VFD Room and Services Building at SSTPP, MPPGCL khandwa for a period of 12 months
Procurement of refrigerant gas R 134a and R 22 for central AC compressor and ESP air conditioning plant of unit no 1 to 5 at SGTPS MPPGCL Birsinghpur
Annual Maintenance Contract for maintenance and repair of air conditioning system fitted in Hydraulic Excavator TATA ZX650 working at Nigahi Project, NCL for a period of one year.
Quotations are invited in electronic form for hiring of 1 No New Petrol Car 3 plus 1 with air conditioner, Maruti Dzire or other equivalent Latest Model 2024 and duly registered in taxi quota
Misc. Electrical works. SH- Procurement of various type of AC, Water Cooler, Water purifier i/c buy back of window, split AC at R.B. Airport, Bhopal.
Supplying and Installation of split type Air Conditioners for VVIP Room No. B-3, B-2, B-1, A-2, A-4 and A-5 at circuit house Satna, Distt. Satna (M.P.)
Repairing and Maintenance of Air Conditioners(installed at different places at EandM field Nigahi Project) and 20 Nos. Water Cooler (installed at EandM Field and CHP) for 01 Year at Nigahi Project.
MOEI AND FANS INCLUDING STREET LIGHT RMO OF PUMP SET, RMO OF DG SET, SUB STATION AND AC AT NIRMAN SADAN, CGO BLDG., BHOPAL. (SH: PROVIDING AIR CONDITIONERS FOR ROOM NO. 313).
Annual maintenance contract for 04 Nos. of air conditioners fitted in operator cabin of IDM 30 drills ( Sl .no 05, 06, 08 and 09) of Jayant project for one year (365 days).
E-TENDER FOR PROPOSED CONSTRUCTION OF CBO-2, CBO-5 AND CUSTOMER ZONE WITH MODERNIZATION and AIR CONDITIONING AT PLOT NO. - A, SCHEME NO. - 74C, SECTOR - C, VIJAY NAGAR, INDORE M.P
Providing, fixing of head sluice gate at Barkhua Tank and Oiling, greasing of Automatic tilting gates at Rajiv Repair and maintenance of air conditioners at the office of the E-in-C, MPWRD, Bhopal, C.E. E/M and S.E., E/M, WRD, Bhopal
ANNUAL REPAIRING AND MAINTENANCE OF 2 (TWO) YEARS AIR CONDITIONER AND WATER COOLER AT IDA BUILDING AND STAFF BANGLOW NO.1 AND 2 IDA INDORE
SUPPLY, INSTALLATION, TESTING, COMMISSIONING OF INTERNAL ELECTRIFICATIOIN AND AIR CONDITIONER INCLUDING 3 YEARS REPAIRING AND COMPREHENSIVE MAINTENANCE WITH SPARES AT CHAIRMAN BUNGALOW-CUM-OFFICE INDORE
CONSTRUCTION OF DIGITAL LIBRARY AND 6 NO. STUDY HALL FOR STUDY OF STUDENTS WITH FULLY AIR CONDITIONER IN SIDHI TOWN UNDER MUNICIPAL COUNCIL SIDHI (M.P.)
Repairing Servicing of Split,Window Air Conditioner installed in Upper Rest House, Erector Hostel, CE Office, CAAQMS PH 4 and other offices of STPS, Sarni
SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF VRV/VRF SYSTEMS AIR CONDITIONER WORK INCLUDING 24 MONTHS MAINTENANCE WORK AT THIRD FLOOR BOARD ROOM IDA BUILDING INDORE
PROVIDING ELECTRIC MAINTENANCE OF NEW V.C. ROOM, SUPPLYING INSTALLING OF AIR CONDITIONER IN COLLECTORATE OFFICE BUILDING AND MAINTENANCE OF GAD RESIDENTIAL BUILDING DINDORI DISTT. DINDORI.