Providing Transformer and Wiring for Air conditioner to be installed at Judicial Court Complex, Faridkot.
Estimate for P/F of Air Conditioner and electricity work in community hall MC Alawalpur
Repair and Overhauling Service - Window Air Conditioner Including Green Ac (DFM); Samsung; Yes; Buyer Premises
Repair and Overhauling Service - Window Air Conditioner including Green AC; BLUE STAR; Yes; Buyer Premises
Repair and Overhauling Service - Window Air Conditioner Including Green Ac (DFM); Voltas; Yes; Buyer Premises
Repair and Overhauling Service - Window Air Conditioner Including Green Ac (DFM); Voltas; Yes; Buyer Premises
Repair and Overhauling Service - Window Air Conditioner Including Green Ac (DFM); Voltas; No; Buyer Premises
Split Type Flame Proof Air Conditioner Units Hot and Cold with Capacity of 2 TR
Supply of Tower type split Air Conditioners, Supply of Hard drawn Copper Refrigerant Piping, Supply of Nitrile rubber insulation, Supply of Cable Tray for refrigerant piping sutaiable, Supply of Powder coated MS Stand, Supply of Powder coated MS ... split Air Conditioners , ...
Voltas1.5 Ton 3 Star Cold Window AC With Stabilizer, Exhaust Fan, Paper A4, Piolet Pen V7, Hedge Cutter, Gun Maintenance register printer, Attendece register printed, Massage log register printed, Paper FS BOQ Title boq bid
Providing and Installation of Inverter Split Air Conditioners with heating and cooling, 2.0 TR, Five Star rated capacity for TBI-1486
Electrical related work of reception renovation at PUDA Bhawan, sector 62, SAS Nagar Supply, Erection, Testing and Commissioning of Air Conditioners.
Electrical work in c/w Provision of Air conditioners in VDU Panel room of SMs at 88 Stations over FZR Division.
Supply and fixing of Air conditioners heavy duty in municipal corporation Patiala office. EST COST RS. 5.50 LCAS DT 10/11.08.2020
Electrical work in c/w Provision of Air conditioners in VDU Panel room of SMs at 88 Stations over FZR Division.
SITC of 6x5.5 TR Ductable split AC units in various TE Bldgs. Under BSNL ED-Jalandhar (Rate Contract)
Supply and replacement of existing AC units at DVOR and other places at Ludhiana Airport (2021-22).
Repair of Air Conditioner and complete in all respect. (2059-PW-60-other buildings-53-99-27-maintainence and repair of Judicial Court Complex residential buildings)
Procurement of Refrigerant Gas Mafron (M-22) for Air Conditioning System at GGSSTP Ropar
Rough Cost Estimate for Supply of Air Conditioner and Sound system for Municipal Council Morinda
STABILIZER AC UP TO 1.5 TON 12 A, SPLIT AIR CONDITIONER 1.5 TON, WASTE WATER PIPE 20 MTR, WORKBENCH 30D X 84W X 30H, WORKBENCH 30D X 72W X 30H
C/o 03 Nos. Class Rooms of 120 Capacity each in science block at SLIET Longowal. SH: Provision of 04 Nos. Cassette AC in the Class Room
PROVISION OF CENTRAL AIR CONDITIONING AND ADDITION ALTERATION TO EE HALLS AT DALHOUSIE UNDER GE AF PATHANKOT
Providing and Installation of Air Conditioning in Khem Singh Gill Committee room (Directorate of Extention Education) at PAU, Ludhiana
ROOF MOUNTED AIR CONDITIONING SYSTEM WITHOUT TROUGH TO SPECN NO. RDSO/2007/EL/SPEC/0055 REV 2. MAKE OWN
Custom Bid for Services - Annual maintainance of Air Conditniors Similar Category ANNUAL MAINTENANCE SERVICE FOR Centralised air conditioning system
1.5 Ton All weather Air Conditioner with 4 KVA stabilizer incl installation and all required mtrl
Electrical wiring and Provisioning for Air Conditioners in cubical rooms of PG Block of Boys Hostel No.8 at the GADVASU, Ludhiana
Providing P.H. Services and Providing and Installing Air Conditioners in Skill Lab at First Floor, Govt. Medical College, Patiala (Under Head 4210).
Air Conditioner Air Conditioner ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values CAPACITY/GENERIC Type of Air conditioner High wall Split AC High wall Split AC Technology of AC Inverter (Variable Speed) Inverter (Variable Speed) Nominal cooling capacity in Ton (kcal/hr) 1.5 Ton/4500 kcal/hr 1.5 Ton/4500 kcal/hr Coil Material Copper Copper Eco-friendly refrigerant true true Minimum length of copper pipe and suitable connecting electrical cable for installation and commissioning 3 metre - Packing LIst REMOTE & USER MANUAL INDOOR AND OUTDOOR UNIT - Any other Features GOOD QWALITY - CONFORMITY CERTIFICATION BEE Star Rating 3 3 Conformity to Indian Standard IS 1391 latest - WARRANTY Warranty on 1 1.0 1/3 Machine Warranty on Compressor 5 5.0 INSTALLATION Installation and commissioning With Installation and Commissioning With Installation and Commissioning * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Gurjeet Singh 140124, Superintending Engineer, Canal Power House Circle, BBMB, Nangal Township 2 28 EMD Required No ePBG Required No
Air Conditioner Air Conditioner ( 30 ) Technical Specifications Specification Specification Name Values Allowed Values CAPACITY/GENERIC Type of Air conditioner High wall Split AC High wall Split AC Technology of AC Inverter (Variable Speed) Inverter (Variable Speed) Nominal cooling capacity in Ton (kcal/hr) 2.0 Ton/6000 kcal/hr 2.0 Ton/6000 kcal/hr Coil Material Copper Copper Eco-friendly refrigerant true true Minimum length of copper pipe and suitable connecting electrical cable for installation and commissioning 3 metre - Packing LIst Remote control - Any other Features none - CONFORMITY CERTIFICATION BEE Star Rating 4 4 Conformity to Indian Standard IS 1391 latest - WARRANTY Warranty on Machine 1 1.0 1/3 Warranty on Compressor 5 5.0 INSTALLATION Installation and commissioning With Installation and Commissioning With Installation and Commissioning * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Shyam SS@123 147003, AEE/RAC, Administrative block, Diesel Loco Modernisation Works 30 15
Repair and Overhauling Service - REPAIR OF AC OF MARUTI SUZUKI CIAZ SIGMA BYBRID; REPAIR OF AC OF MARUTI SUZUKI CIAZ SIGMA BYBRID; Yes; Service Provider Premises
REPAIR AND MAINTENANCE OF DIFFERENT TYPE OF COOLERS, AIR CONDITIONERS, FREEZERS INCLUDING MISC WORKS UNDER AGE E/M-II OF GE (N) MAMUN
S/Fixing Split AC (Complete with fitting for Shaeed Bhagat Singh Park and Library) in Ward No.24
Repair and Maintenance Window and Split AC and AMC two years at Head Office Building MCA Ranjit Avenue.
SITC of Hi wall hydronic type Fan Coil Units(FCU) -) -3 nos & Ductable Split AC- 1no with etc.
Maintenance and Repairing of Window, Split and Ductable Air Conditioner of Municipal Corporation, Amritsar. (IInd Call) 970700
Air Conditioner ( PAC Only ) Air Conditioner ( 1 ) ( Under PAC ) Make voltas Model voltas183 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values CAPACITY/GENERIC Type of Air conditioner ... wall Split AC High ... wall Split AC Technology ...
Additions Modification and Automation of existing Heating Ventilation and Air Conditioning system installed at PUDA Bhawan Sector 62 at SAS Nagar
Provision of Air Conditioning of 2nd Floor at Girls Hostel (New Block), Guru Angad Dev Veterinary and Animal Sciences University, Ludhiana.
CWE/FZR-48/2020-21 Repair and maint of central Air Conditioning Plant of 159 GH under GE (East) Ferozepur Cantt
ROOF MOUNTED AIR CONDITIONING SYSTEM WITHOUT TROUGH Specification :-RDSO Specn No- RDSO/2007/EL/SPEC/0055, Rev.-2 with latest rev.
SUPPLYING INSTALLATION AND COMMISSIONING OF SPLIT TYPE VARIOUS CAPACITY AIR CONDITIONERS AND ALL OTHER WORKS CONTINGENT THERETO AT JUDICIAL COURT COMPLEX PHUL DISTRICT BATHINDA
MC AC REPAIR, MC SELF STARTER REPAIR, MC ALTERNATOR REPAIR, MC FUEL PIPE REPAIR, MC WHEEL ALIGNMENT AND BALANCING
Repair and Maintenance Window and Split AC and AMC two years at Head Office Building MCA Ranjit Avenue. 1980000
Providing and Fixing Air Conditioner and Water Geyser at Bhagwan Valmiki Tirath Sthal Distt. Amritsar (under Deposit Work)
SUPPLYIN INSTALLATION TESTING AND COMMISSIONING OF SPLIT TYPE AIR CONDITIONERS IN ADDITIONAL BUILDING IN PESTICIED LAB AT BATHINDA IN HOD ROOM STAFF ROOM GLASSWARE ROOM CHEMICAL ROOM GENERAL ROOM SAMPLE STORAGE ROOM AND OFFICE STAFF ROOM COMPLE
Refrigeration and Air Conditioning at 1FBSU, AF, Amritsar. (PB). dg. 2025-26. (Code Head:- 51/761/06) SH:- Robotic cleaning of ducts.
Installation of Air Conditioning System at the Passage Area of Ground Floor and First Floor of Udyog Bhawan Building Sector 17 Chandigarh
REPAIR AND MAINT TO SUMMER APPLIANCES SUCH AS AIR CONDITIONERS, WATER COOLERS, DESERT COOLERS, REFRIGERATORS, AC PLANT AND VOLTAGE STABILIZERS ETC AT MIL STN ABOHAR.