Loading…
Loading…
114 results • Best match
Hiring of Consultancy Services - Percentage based - Technology Consultants; GIS Expert, Architect -Software Solution, Topographical survey and soil Investigation; Yes; Hybrid(As specified in scope of work)
Hiring of Consultancy Services - Percentage based - Technology Consultants; GIS Expert, Topographical Survey and soil Investigation, Architect -Software Solution; Yes; Hybrid(As specified in scope of work)
Monthly Basis Cab & Taxi Hiring Services - Sedan; 2000 km x 320 hours; Local
Construction of boundary wall & Entry Gate and other associated works like Soil Testing, Topographically Survey, Preparation of architectural and structural drawings, Vetting of Drawings from IIT/NIT, Preparation of DPR etc.
Construction of boundary wall & Entry Gate and other associated. Soil Testing, Topographically Survey, Preparation of architectural and structural drawings, Vetting of Drawings from IIT/NIT, Preparation of DPR etc. at Fatehgarh Sahib, Punjab.
Construction of boundary wall & Entry Gate and other associated. Soil Testing, Topographically Survey, Preparation of architectural and structural drawings, Vetting of Drawings from IIT/NIT, Preparation of DPR etc. at Lalru, Patiala, Punjab.
pabx system-EPABX Experience with Gov. Required 5 Year (s) Pabx System-EPABX ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values EXTENSION AND TRUNK/JUNCTION EPABX system Implementation Tech nology/Architecture Hybrid ( Microprocessor based also supporting SIP extension ) Conventional ( Card/microcontroller based ), Hybrid ( Microprocessor based also supporting SIP extension ), Server Based ( Switching through Call Server Application ) Number of Analogue Extensions/FXS Ports 96 As per GeM Catalogue. (or higher) Expandable Upto (TDM/FSX Ports) 128 As per GeM Catalogue. Number of Digital Extensions 4 4, 8, 16, 24, 32, 64, 128, NA Number of Analogue Junction/FXO ports 8 As per GeM Catalogue. Number of SIP Extensions NA As per GeM Catalogue. SIP Extensions expandable upto NA As per GeM Catalogue. Number of SIP Trunks NA 4, 96, 256, NA 1/11 MAIN DISTRIBUTION FRAME(MDF) MDF(Number of pair) 100 As per GeM Catalogue. Integrated Protection Module(IPM) true true, false If YES, number of Integrated Protection Module(IPMs) 100 As per GeM Catalogue. CARDS CARDS Type of Cards Supported BRI, PRI, E1, E&M, Radio Interface, GSM BRI, GSM, NA Number of Ports per Card Supported 24 1, 2, 4, 6, 12, NA GATEWAYS Type of Gateways Supported PRI, E1 - Number of Ports per Gateway Supported 24 - CONSOLE Type of Operator Console Key phone based PC based, Key phone based, Server Based, NA Number of Operator Console 1 As per GeM Catalogue. SERVER SPECIFICATIONS REQUIREMENTS Total Number of Servers Included in the Supply NA As per GeM Catalogue. "Number of Hot Standby Servers out of Total Servers, included in the Scope of Supply" 0 - Server Form Factor NA - Rack Size (RU)/Space Required for each Server NA - Processor Make NA - Processor Configuration & Description NA - Total Number of processor NA 1, 10, NA Number of Redundant Processors Included in the Total Number of Processor NA 1, NA Number of Cores per Processor NA As per GeM Catalogue. Type of RAM NA - RAM Size (in GB) NA 4, 128 2/11, NA T ype of Hard Disk Drive NA - Capacity of Hard Disk Drive (in TB) NA As per GeM Catalogue. Hot Swap Components Power Supply Unit Power Supply Unit, Fans, HDD, NA Network Interface USB - SOFTWARES Applcation Software Type/Capabilities Call Server Software Call Server Software, Hot StandBy Server Software, Unified Communication Server Software, Network Management Server Software, NA Type of Licence NA Perpetual, Subscription Based, NA Name of Softwares Na - Name of the OEM Panasonic - OEM Model/Part Number NA - Software Description NA - Software Version NA - Date of Launch of Version NA - Free supports/updates during validity of license NA - SOFTWARE FEATURES Analog Extention/FXS ( If Yes, Number of Software/Licences shall be Commensurate Equal to the Number of Analog Extension/FXS Offered under ""EXTENSION AND TRUNK/JUNCTION"" ) NA ( For Convensional PBX ) YES, NO, NA ( For Convensional PBX ) "Digital Extension ( If Yes, Number of Software/Licences shall be Commensurate Equal to the Number of Digital Extension Offered under NA ( For Convensional PBX ) YES, NA ( For Convensional PBX ) 3/11 ""EXTENSION AND TRUNK/JUNCTION"" )" "Analog Junction/FXO ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of Analog Junction/FXO Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NA ( For Convensional PBX ) YES, NA ( For Convensional PBX ) "SIP extension ( If Yes, Number of Software/Licences shall be Commensurate Equal to the Number of SIP Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" NA ( For Convensional PBX ) YES, NA ( For Convensional PBX ) "SIP trunk ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" NA ( For Convensional PBX ) YES, NA ( For Convensional PBX ) "PRI Trunk ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of PRI Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NA ( For Convensional PBX ) YES, NA ( For Convensional PBX ) "Radio Interface ( If Yes, Number of Software/Licences shall be Commensurate Equal to the Number of Radio Interface Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" NA ( For Convensional PBX ) YES, NA ( For Convensional PBX ) 4/11 "GSM ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of GSM Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NA ( For Convensional PBX ) YES, NA ( For Convensional PBX ) "E1 Trunk ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of E1 Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NA ( For Convensional PBX ) YES, NA ( For Convensional PBX ) "E&M ( If Yes, Number of Software Licences shall be Commensurate Equal to the Number of E&M Offered under ""EXTENSION AND TRUNK JUNCTION"" )" NO YES, NO GENERAL FEATURES of EPABX SYSTEM Number of Conference Participants Supported 8 8, NA Number of Direct Station Selection Keys per Console 24 - Number of Media Channel/Ports Supported 24 8, 512, NA Number of IP-TDM Concurrent Calls(2 users per call) Supported NA As per GeM Catalogue. Call Buffer Memory System true true, false If Call Buffer Memory Available, Number of Records 100 100, 250, 500, 1000, 2000, NA Hot Standby Redundant CPU false true, Number of Hot Standby CPU Cards NA 1, NA 5/11 Hot Standby Redundant PSU (Power Supply Unit) false true, Number of Hot Standby Redundant PSU Cards NA 1, NA Inbuilt Voice Mail for EPABX System false true, false If Voice Mail Available, Number of Voice Mail Channels NA 4, NA Available for Voice Mail, Number of Hours of Recording NA 4, NA Auto Attendant Facility false - If Available, Number of Auto Attendant Channels NA - ASMDR/CDR true true, false Voice Logger NA Inbuilt, Inbuilt External Connecting facility, NA If YES, Number of Simultaneous Calls that can be Recorded in Voice Logger NA - Security Feature(for server based) NA - Supported Functionalities (for server based) NA - Supported Codecs NA - Any other features NA - SYSTEM/EXTENSION/AT TENDANT CONSOLE FEATURES System Features Automatic Route Selection facility, DID facility(Direct inward dialing), DOD facility(Direct outward dialing), DISA facility(Direct inward station access), DOSA facility(Direct outwards station access), Multi Level Voice DISA facility, Privacy of Call, Facility for connecting recorded voice answering, ASMD R/CDR, Programmable class of service for As per GeM Catalogue. 6/11 (STD/ISD/LOCAL) dialing as per need, Caller ID information for both internal and external callers (over Analogue, ISDN PRI), unique authorization codes for every users, Automatic call back, Call waiting, Music-on-hold facility, Call budgeting, Least cost routing, Mix-mode dialing, Provision for remote logins, Interactive Voice Response System(IVRS), Extensio n to Extension dialing Extension Features Call forwarding, Consultatio n Hold, Brokers Call, Automatic call transfer, Conference call, Call pick up, Call re routing, Auto call disconnection, Dynamic STD Lock, Paging on key phone, Background music, Password control, Virtual Telephony, Howler Tone, Call parking, Auto answer/Auto off, Emergency call facili ty, Missed/Dialed/Receiv ed Call Lists, Last Caller Call back, Password display suppression, Personal Identification Number, Hotline, Preset Conference Calls, Direct Call billing in rupees, Call billing printout, Calling line ide ntification(CLI), Remote Maintenance, Other Extension features As per GeM Catalogue. Attendant Console Features Answering an incoming call, Call queuing, Serial Call, Call waiting display, Automatic Call Distribution, Call Hold, Trunk Answering an incoming call, Trunk offering, Night 7/11 offering, Night service, Head phone connectivity, Other Attendants console Features service, Other Attendants console Features Voice Prompts and Announcement false - If yes, Number of Levels of IVRS NA 1, 3, 5, 7, NA POWER SOURCE Supply Voltage 230V AC, 50HZ 230V AC, 50HZ, 48V DC, NA Provision for Inbuilt Battery Charging Arrangement for providing Battery Backup YES - FCBC NO YES, minimum current Rating of FCBC at chrging voltage of 48V (Ampere) NA 10A, 12.5A, 25A, 50A, NA Protection against over current and accidental reversal of polarity on the input side and against over current, over voltage on the output side YES - OPERATING CONDITIONS Minimum Operating Temperature (Degree C) 5 10, 0, 10 Maximum Operating Temperature (Degree C) 45 35, 40, 45, 50, 55 Operating Humidity (RH) (% ) 85 80, 85, 90, 95 TEST REPORT DETAILS AND TESTS TEC approval as per the latest TEC specifications YES - TEC approval Certificate number Panasonic/2008/789 - Availability of the test report from Central Government/NABL ILAC acredited lab to prove conformity to the specification including Environmental Test Sequence false - 8/11 Test reports consist of verification of all the features & functional parameters & environmental tests true - conformity to Dry Heat for 16 hours at maximum specified temperature degree C in accordance with IS:9000/part-3/sectio n-5/1977 latest true true, false conformity to Cold Test for 4 hours at minimum specified temperature degree C in accordance with IS:9000/part-2/sectio n-4/1977 latest true true, false conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH in accordance with IS:9000/part-5/s ection-1/1991 latest true true, false INSTALLATION AND MAINTENANCE Installation and Commissioning Without With, Without Chemical Earthing to achieve resistance 2ohm true true, false Yes is better Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System yes - OPERATION & MAINTENANCE SUPPORT The scope of supply include one set of operation and maintenance manual for each equipment YES - Operation & Maintenance terminal NA(for conventional EPABX) - Training provided to buyers true true, Details of training On site training for 3 days On site training for 3 days, On site training for 5 days, NA 9/11 Packing List yes - SERVICES Warranty 1 1, 9, 10 Higher is better Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System, yes - Compliance to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Amit A Patil 140603, K Area, Zirakpur, Near Dhakoli Village, Rajpura, 1 15
Soil testing for SBC of Bldgs a Determination of safe bearing capacity of soil by standard penetration test method upto 10 metre, Design the structural Drg and Architectural Drg alongwith detail estimate for the Bldgs of Size 22 mtr x 10 mtr x 05 ... and Architectural Drg ...
Construction of boundary wall & Entry Gate and other associated work i.e. Soil Testing, Topographically Survey, Preparation of architectural and structural drawings, Vetting of Drawings from IIT/NIT, Preparation of DPR etc. at Tanda, Hoshiarpur, Punjab.
Product Lead, Engineering Lead, Delivery Lead, Project Manager, Application_ Database Architect, Database Admin_ Data warehouse Developer, DevOps, Sr. Business Analyst, Micro services Architect_Lead Developer, Sr. Java Developer, Sr. Frontend Developer, Java Developer, Full Stack Developer, UI_UX Designer, Android Developer, Frontend Developer, Database Admin _ Data warehouse Developer, Quality _ Security Engineer
Manpower Outsourcing Services - Fixed Remuneration - Others; PARK SUPERVISOR; HIGH SCHOOL OR DIPLOMA IN AGRICULTURE, Manpower Outsourcing Services - Fixed Remuneration - Others; PRADHAN MALI; HIGH SCHOOL OR DIPLOMA IN AGRICULTURE, Manpower ... OR ARCHITECTURE FROM ... OR ARCHITECTURE FROM ... OR ARCHITECTURE FROM ...
Applied Physics - I and II, Industrial Engineering and Production Management, Workshop Technology I, Workshop Technology -ll, Workshop Technology III, CNC Programming Basics and Tutorial, A Textbook of Strength of material, A Textbook of Applied ... COMPUTER ARCHITECTURE , ...
Business intelligence and data analysis software, Bu Average Turn Over of Last 3 Years 500 Lakh (s) Experience with Gov. Required 3 Year (s) Business Intelligence And Data Analysis Software ( 2 ) Technical Specifications Specification Specification ... false Architecture aware ... false Architecture aware ... false Architecture aware ... true Architecture aware ... false Architecture aware ... false Architecture aware ... true Architecture aware ...
Storage System, SAN Switch, Layer 2 Access Switch, computer servers, computer servers Average Turn Over of Last 3 Years 360 Lakh (s) Experience with Gov. Required 3 Year (s) Storage System ( 1 ) Technical Specifications * As per GeM Category ... Blocking Architecture Yes ...