Loading…
Loading…
61 live28 closing this weekmost from Karnataka Power Transmission Corporation Limited and South Western Railway
61 results • Best match
Establishing 2x20MVA, 110/11kV Sub-station at Kandakur in Gurmitkal Taluk, Yadgir District and Construction of 110kV LILO line using Lynx conductor from existing 110kV Ramasamudra-Konkal SC line to proposed 110/11kV Sub-station at Kandakur for a distance of 6.912km in Yadgir Taluk, Yadgir District on Partial Turnkey basis including Supply of all matching Materials/ Equipments (Excluding Supply of 11kV Switchgear),Erection (including Dismantling & Civil Works) of all Materials/ Equipments, Testing and Commissioning.
Establishing 2x20MVA, 66/11kV Sub-station at Hadinaru and construction of 66kV LILO Line on 110kV DC Towers using Coyote Conductor from proposed 66kV Immavu-Ayrahalli (On going) SC line to the proposed 66/11kV Hadinaru for a distance of 3.589km in Nanjangudu Taluk, Mysuru District on Partial Turnkey basis including supply of all matching materials/ equipments (Excluding supply of 11 kV Switchgear) and erection (including civil works) of all materials/ equipments, testing and commissioning.
Establishing 2X20MVA, 110/11kV Sub-station at Halapura (Joladarasi) and Construction of 110kV LILO line using Lynx conductor from 110kV Maski - Hutti line to the proposed 110kV Sub-station at Halapura (Joladarasi) for a distance of 9.39km in Maski Taluk & Raichur District including Supply of all matching Materials/Equipments (Excluding Supply 11kV Switchgear) and Erection (Including Dismantling and Civil Works) of all Materials/ Equipment, Testing and Commissioning
Construction of 66kV SC link line on 110kV NB DC towers with Panther conductor for a distance of 11.070kms from 66/11kV Badanaguppe sub-station to 66/11kV Jannur Sub-station and construction of 1 no. of 66kV Terminal Bay at 66/11kV Badanaguppe Sub-station & 1 no. of 66kV Terminal Bay at 66/11kV Jannur Sub-station in Chamarajanagara Taluk and District on Total Turnkey basis including supply of all matching materials/equipments, erection and dismantling (including civil works) of all materials/equipments, testing and commissioning
Establishing 2x20MVA, 110/11kV Sub-station at Masuti in Kolhar Taluk, Vijayapur District, Construction of 110kV LILO line from ongoing 110kV Telagi LILO line (110kV B.Bagewadi-Telagi-Mamdapur line) for a distance of 0.906km using Lynx conductor in Kolhar Taluk, Vijayapur District,Dismantling/Releasing and restringing of assets pertaining to the work of establishing 2X20MVA, 110/11kV Sub-station at Masuti in Kolhar Taluk, Vijayapur District,onPartial Turnkey basis including Supply of all matching Materials/Equipments (Excluding Supply of 11kV Switchgear),Erection (including Dismantling & Civil Works) of all Materials/ Equipments, Testing and Commissioning
Establishing 2x20MVA, 66/11kV Sub-station at Sasvihalli Village in Harapanagalli Taluk, Vijayanagara District, Construction of 02 Nos. of 66kV Terminal Bays at existing 66/11kV Bennihalli Sub-station in Harapanagalli Taluk, Vijayanagara District and ... Panther conductor from ...
Establishing 2X20 MVA,66/11kV Sub Station at Tuppadahalli (Kenchapura) by Constructing 66kV DC line on DC/MC towers from 220/66kV Benkikere Substation by utilising the existing corridor of 66kV Benkikere Ramagiri SC line corridor using Panther ... Panther conductor & ... Panther Conductor for ...
Establishing 2X20 MVA, 66/11kV Sub-Station at Neralekere in Magadi taluk, Bengaluru South district and Construction of 66kV DC Line on DC towers from existing 220/66kV Anchepalya sub-station to the proposed 66/11kV Neralekere sub-station for a ... Panther conductor along ...
i) Supply and installation of voltage Monitoring relays, Timers, Auxiliary contactors with add on blocks, Auto/Manual selector switch, push buttons ON,OFF and RESET as per site requirement ii) Supply of 1.5 sqmm copper cable, wiring accessories, terminal blocks as per site requirement iii) Control circuit wiring for Automation of 4 Nos. of 2000A Unit auxiliary ACBs (U-2, U-4, U-5 & U-7), 2000A Bus coupler breaker & 800A DG breaker along with interlocking of six breakers at LTAC panel as per site requirement iv) Testing of operations of all the ACBs of LTAC Panel.
MIL-DTL 22759/86A 3 core shielded & Jacketed cable 22 AWG 600V silver plated copper braid PTFE tape, MIL-DTL 22759/86A 2 core shielded & Jacketed cable 22 AWG 600V silver plated copper braid PTFE tape, MIL-DTL 22759/86A 1 core polyamide & PTFE ... strands conductor 600,
Improvement work