Loading…
Loading…
4,224 results • Best match
Estimate for Augmentation of 11 Kv. line conductor at 11 Kv. line conductor at 11 Kv. Pipariya Pump feeder Under Rampur D.C. of ONM Division Guna.
Survey, Supply, and Installation of minor material and repl. of defective Isolator, AB switch and Male/Female contact of AB switch along with Aug. of Bus Bar Conductor at various 33/11 KV S/s under SSTD Scheme in (OandM) Circle Bhopal
Estimate for replacement of 11 kv pole providing the Raccoon Conductor of 11 kv line to restore the supply against theft at various location Mou to Taroli Loharpura Har Salampura-Dehgaon Dehgaon Har under Mau D/C in O M Dn. Gohad.
Estt. is prepared to avoid unwanted tripping due to bird fault at various location/DP/4P struct. on different 33 KV fdr after laying covered conductor at bird fault locations of 33 KV Ramakhedi, Dahod, Reliance, Mahapet-II and Venktesh Fdr Under IGC
Online Bid has been invited for installation of 5 No. 100 KVA DTR by laying 11 KV and LT line on AAAC Rabbit/weasel conductor and 10 No. augmentation of 25 to 63 KVA DTR in Mandsaur ,Garoth,Sitamau and Malhargarh division
Online Bid has been invited for installation of 5 No. 100 KVA DTR by laying 11 KV and LT line on AAAC Rabbit/weasel conductor and 10 No. augmentation of 25 to 63 KVA DTR in Neemuch,Jawad and Manasa OnM division
Supply, Installation, Testing and Commissioning of New 11 KV line for Bifurcation and Interconnection, Addl 11KV Bay at 33/11 KV Substation, Augment. of Conductor of 11 KV Lines etc under Lot IX Gwalior City, Gwalior O and M, Datia Circle under RDSS
Estimate for Replacment of 04 No. PCC Pole and Erect 08 No. Mid Span Pole Drwa 0.6 Km conductor for 33 KV SPM feeder at location Jasalpur to fourline Road under N,Puram (R) D/c under O and M Division Narmadapuram
Smart Alluminum clamp suitable for Dog Panther ACSR Double conductor clamp size 145 mm x 90mm x 50 mm fitting with 8 nos. GI Nut and Bolt with plain spring washer weight of clamp 1.00 Kilogram (CB Smart clamp) Make Avni/ISO Certified
Survey Supply and Installation of minor material and replacement of defective Isolator AB switch an Male/Female contact of AB switch along with Augmentation of Bus Bar Conductor at various 33/11 KV S/s on semi turnkey contract basis under Raisen Cir.
Hiring of One No. Bus model 2021 onwards with running not more than 100000 kms, having seating capacity minimum 35 seats, with Diesel, Driver and Conductor, for a period of 24 months, maximum monthly run 4280km at SSTPP, MPPGCL, Dongalia, Khandwa (MP
PROVN OF DHOBI GHAT TO OTM ACCN FOR INF BN NO 2, WATER UNDERGROUND STORAGE FACILITY OF 238 FD, STAIR CASE WITH TWO WOODEN DOOR, SECURITY LIGHTS FOR 115 INF BDE CAMP, GEYSER FOR SINGLE OFFRS AND LIGHTNING CONDUCTOR AT DHANA MILITARY STATION.
Revis. esti Aug.of con. at existing 11 KV Ramnagar Pump feeder Kolaras R (240326) Revis.esti Aug.mentation of condu. 11 KV Rai Pump feeder (239725) Revi esti.for Aug. of conductor at existing 11 KV Berkhedi Pump feeder Kolaras R Spr.(239869) (NIT-43
Revised Estimate for Theft of 30 Sqmm Conductor,11 KV line Pin Insulater-9, Stay Wire-22 KG and 20 No. Broken at Between Vill. Aam Chauki and Basai Bairad-II of Shivpuri DN.I letter No. 962 dt. 17.02.24 (118782) (NIT-11)
DISMANTLING AND FIXING OF STEEL TUBULAR POLES, INSULATORS, STAY SETS V CROSS ARMS, STRINGING OF 440 V OH LINE FOR FIXING SPRINKLER 3.3 KV OH LINE WITH EARTH CONDUCTOR FOR PUMPING EAST PART WORKING 230V LIGHTING AT KANCHAN MINE OF JOHILLA AREA
Modification Shifting of 132 Kv Sabalgarh Sheopur DCDS Line which involves Tower Erection of 01 No. MC60 and 02 No. E60 Type Towers at an approx. Height of about 06 Meters Above Pile Foundation welding 6 Panther Conductor Stringing with OPGW etc.
Supply, Installation, Testing and Commissioning of New 11 KV line for Bifurcation and Interconnection, Additional 11 KV Bay at 33 11 KV Sub station, Augmentation of Conductor of 11 KV Lines etc Lot I Bhopal City and Sehore Circle under RDSS Scheme
Supply, Installation, Testing and Commissioning of New 11 KV line for Bifurcation and Interconnection, Additional 11KV Bay at 33 11 KV Substation, Augmentation of Conductor of 11 KV Lines etc Lot II Bhopal O and M and Vidisha Circle under RDSS Scheme
Smart aluminum PG Clamp suitable for panther ACSR double conductor clamp size 145 MMX 90 MM X 50MM fitting with 3 Nos GI nut and Bolt with plain spring washer weight of 1.650 grams approx. 5 percent Plus tolerance Make AVNI / ISO certifie...
Supply, Installation, Testing and Commissioning of New 11 KV line for Bifurcation and Interconnection, Addl 11KV Bay at 33/11 KV Substation, Augmentation of Conductor of 11 KV Lines etc under Lot XI(B-II) Mehgaon Dn of Bhind Circle under RDSS
Special Repair for conversion of LT OH conductor into UG Cable for TS Road, Ordnance Road, S/S No. 07 to GP-02, Anant Nagar,ASD Line and Gandhi Colony, OP-02 to OP-03area of 506 ABW under GE(East) Jabalpur
Supply of 1.5 TR Invertor ductable AC, Supply of 3.0 TR Invertor ductable AC, ITC of 1.5 TR ductable AC, ITC of 3.0TR ductable AC, Supply fixing Copper Piping for 1.5 TR, Supply fixing Copper Piping for 3.0 TR, Supply fixing MS Stand, SF UPVC Drain ... alu conductor armoured cable , ... alu conductor armoured cable , ...
for separation of 11 KV Mix Feeders and Mix DTRs under project financing from KfW for Feeder Separation (FSP) Package- Indore OnM, Khandwa, Burhanpur, Khargone, Badwani, Dhar
Fixed Capacitors (Fixed Capacitor For Single Phase Ac Electric Fan)-IS: 1709:1984 (Q3), PVC Copper cable single and multi core Circular Sheathed cable with flexible Conductor as per IS:694 (Q3), Non Modular Elecrical Switches And Accessories Flush Type-IS 3854 (Q3), pressure sensitive adhesive plasticized pvc tapes with nonthermosetting adhesive as per IS:7809 (Part 3/section 1) (Q3), modular electrical switches and accessories (Q3), Miniature Circuit Breakers-IS 60898-1:2002 (Q3)
OFC CABLE, CAT6 CABLE, POE SWITCH, RJ45 CONNECTOR, RJ45 FEMALE CONNECTOR, PTZ CAMERA POWER SUPPLY, PTZ CAMERA POWER CABLE, TISSUE PAPeR IN PACKET, OFC POWER METER, STRIPPER FOR OFC CLEAVER CUTTER AND SPLICING MACHINE, ISOPROPYL CLEANING LIQUID, PATCH ... BOX, POWER CABLE , ...
sec BTY 6/12v 150Ahc, Dry Bty SMF(VRLA) 12v-100,26,17,12,7.5,7.2,7Ahc NiMH Bty 7.5v, Bty charger,Power Pack,UPS,SMPS,Iron Mastand assys.,Spare Part of W/sets and other eqpts.,tools,MISC. Items,Guy rope,Coaxial Cable,Copper Wire
BOGIE BRAKE HANGER SAFETY PIN L CLAMP FOR LOCOMOTIVE AS PER IS 2062 DRG NO ET MISC 259, A SET CONSISTING OF 04 ITEM HIGH TENSILE HEX HEAD BOLT SCREW GRADE 10.9 AS PER IS 1367, PVC INNER SHEATHED CONTROL CABLE COPPER CONDUCTOR 1.0 SQ MM 25 CORE WORKING VOLTAGE 650V 1100V AS PER IS 694, T spanner with box head size 8 mm length 100 mm, Hex head cap screw
Road Marker Paint, Geru Powder, White Distemper, Varnish, Wooden Dust, PVC Insulated Electric Cable 1 Sqmm 90 Mtr Roll, Flexible Wire 0.75 Sqmm 90 Mtr Roll, Tracing Cloth, Single Side Photo Paper, Grade 3 Scantling Teak Wood, Fiber Glass Sheet 8 Feet x 4 Feet x 6mm
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 3, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2025/B/6721685 Dated : 25-09-2025 Bid Document 1/6 Number of Auto Extension count 1 Bid to RA enabled No Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No
Cable Copper PVC 1.1 KV 4 Core 25 Sq. mm (Q3), Cable Copper PVC 1.1 KV 4 Core 35 Sq. mm (Q3), Cable Copper PVC 1.1 KV 4 Core 70 Sq mm (Q3), Cable Aluminium Armoured Cable 3.5 C/4 C x 150 Sq. mm (Q3)
Center Pivot Irrigation System, HDPE Pipe, Aluminium Armoured Cable, Submersible-Monoblock pump set, CI Non- Return Valve, Isolation Valve, Earthing for pump set, Genset, Sump, RCC pad for center pivot, Excavation and backfilling of trench, Installation- commissioning, operational and maintenance training of center pivot system complete
RFID System, Installation and Fitting, NVR, Optical to Ethernet, RFID Software, Bullet Camera, RFID Antenna, Power Cable, Management Console, POE Switch, RFID Tag, RFID Reader, Cat 6 Cable
Custom Bid for Services - Testing of Insulation Mats, Custom Bid for Services - Relay overload testing, Custom Bid for Services - LT Cable Insulation Resistance testing, Custom Bid for Services - HT Cable Insulation Resistance testing, Custom Bid for Services - Transformer WTI OTI testing and caiberation, Custom Bid for Services - Thermography of Electrical panel feeder/incomer Similar Category Operation and Maintenance Of Electrical Systems/Electrical Installations Operation and Maintenance Of Electrical Systems/Electrical Installations Operation and Maintenance Of Electrical Systems/Electrical Installations Operation and Maintenance Of Electrical Systems/Electrical Installations Operation and Maintenance Of Electrical Systems/Electrical Installations Operation and Maintenance Of Electrical Systems/Electrical Installations
MULTIWELD Conforming to IS 9857: 1990 (latest) Heat resisting, Oil, MULTIWELD Conforming to IS 9857: 1990 (latest) Heat resisting, Oil resisting and Flame retardant (HOFR) normal duty elastomeric compound (Type: SE3, confirming to IS 6380: 1984) ... of Conductor (mm²)
Survey, Supply and Installation of minor material and replacement of defective Isolator, AB switch and Male/Female contact of AB switch along with Aug. of Bus Bar Conductor at various 33/11 KV S/s on semi turnkey contract basis O and M Betul Circle
Estimate had been prepared against Sanctioned ERP No. 788027 for work mentioned in annexure-III 6.2 KM 11 KV line Shahpur to Sultanpur and 12 Km Conductor Augmentation Line Shahpur to Bharwas With 1 No add. Bay Under Bagroda DC of Oand M Basoda
REMOVAL OF PRESENT 3.3 KV OVERHEAD LINE FROM OLD MINE SUB STATION TO GAJRA NALA LOCATED IN SHRUBBY AND BUSHY AREA NAD INSTALLATION OF NEW EASILY ACCESSIBLE SHORT 3.3 KV LINE(1.3 KM) AND REPLACEMENT OF OLD DAMAGED ALUMINUM CONDUCTOR IN PALI SUB AREA
TR-07-2022 for 2nd Ckting of 132KV DCSS Damoh220-Patera line with ACSR Panther Equivalent HTLS Conductor for power supply to Greenfield Cement plant proj. at village-Harduwaken, Dist.-panna of M/S Jaykaycem Ltd. from 132KV S/S Patera on Turnkey Basis
Material for Construction of Earthing pits, Copper Plate, Copper Strip, Common Salt, Charcol, Supply of PVC Pipe, Material for Construction of Concrete box with lid, Brazing of interconnection, Multi-strand insulated copper wire, Equipotential Earth ... insulated copper wire , ... Insulated Copper Wire , ... braided copper wire bare ... bolt, Copper Wire Non ... Insulated copper wire , ...
XLPE Cables for Working Voltages From 3.3 KV up to and Including 33 KV as per IS 7098 (Part 2) (Q3), XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) (3 (3 ))
Galvanized pole 9 meter, XLPE Cable for Working Voltage up to and Including 1.1 KV Marked To IS 7098 (Part 1), LED Luminaire For Road And Street Lights Conforming To IS 10322 (Part 5/Section 3) (V3) (Under BIS Scheme - II)
Supply Erection of 11 KV Conductor Augmentation of 11 KV Tanda IRRI Feeder Conductor Aug at Location Bagh to Kanti under Bagh Dc of Kukshi Dn in DHAR Circle
Supply Erection of 11 KV Conductor Augmentation of 11 KV Narwali IRRI Feeder Conductor Aug at Location Bagh to Takari under Bagh Dc of Kukshi Dn in DHAR Circle
GI PIPE 100 MM (Q3), HEADER (Q3), 8X8 FT CARBON FIBER BOAT (Q3), 06 Sq MM 3 CORE COPPER CABLE (Q3), 20 HP HORIZONTAL OPEN WELL (Q3), 20 HP STARTER PANEL (Q3), 110 MM HDPE PIPE (Q3)
4.8 X 7.5 MM BARE 4.95 X 7.65 MM COVD SINGLE LAYERED HALF LAPPED POLYIMIDE COVERED COPPER WIRE TO BP28195 REV-10. MATERIAL TO BE SUPPLIED IN STURDY NON RETURNABLE WOODEN DRUMS OR RETURNABLE PLASTIC BOBBINS WITH 60-80 KGS NET WT.
and Mix DTRs in Ujjain OnM, Dewas OnM, Shajapur OnM, Agar OnM, Ratlam OnM , Mandsaur OnM and Neemuch OnM Circles (LOT-07) under the Revamped Reforms-based and Results-linked, Distribution Sector Scheme
and Mix DTRs in Jhabua OnM Circle (LOT-06) under the Revamped Reforms-based and Results-linked, Distribution Sector Scheme
construction of 12 nos T-II, 8 nos T-III and 4 nos T-IV qtrs i/c IEI and fans ,fittings,CL,SC,p/set and lightning conductor for IB DRTC MV palace shivpuri MP - SH : pdg. services for operation of computer system Subwork/Packages: work
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2) MSE Exemption for Years Of Experience and Turnover Yes Startup Exemption for Years Of Experience and Turnover Yes Document required from seller Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer Do you want to show documents uploaded by bidders to all bidders participated in bid? No Bid to RA enabled No Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days Bid Number ( ) : GEM/2025/B/6016331 Dated : 03-03-2025 Bid Document 1/5 Inspection Required (By Empanelled Inspection Authority/Agencies pre- registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No MII Purchase Preference MII Purchase Preference No MSE Purchase Preference MSE Purchase Preference Yes 1. If the bidder is a Micro or Small Enterprise as per latest definitions under MSME rules, the bidder shall be exempted from the requirement of "Bidder Turnover" criteria and "Experience Criteria" subject to meeting of quality and technical specifications. If the bidder is OEM of the offered products, it would be exempted from the "
Supply of Bi-metallic VCB Clamp suitable for 0.075 Sq mm conductor