Loading…
Loading…
1,129 results • Best match
Expansion of Cattle Pound by providing P.H. Services SWD and Fire Fighting shallow tube well Rain water harvesting Gobar gas Plant STP and all other works contingent thereto at Raipur Kalan UT Chd. SUB HEAD CONSTRUCTION OF TEMPORARY SHED AT ETP PLANT
Rectification of leakage in MS Pipe line hydrant valve and overhead tanks for fire fighting systems and repair of electrical mechanical work in various Non Residential Building at Police Line Sec 26 fall under the jurisdiction of SDE WS Sub Divn No 1
EXPANSION OF CATTLE POUND BY PROVIDING P.H. SERVICES SWD AND FIRE FIGHTING SHALLOW TUBEWELL RWH GOBAR GAS PLANT STP AND ALL OTHER WORKS CONTINGENT THERETO AT RAIPUR KALAN UT CHD. SUB HEAD PROVIDING AND LAYING OF INLET AND OUTLET PIPELINE FOR ETP
RMO EI & Fans in various residential colonies located at Sector 24, 41 & 42 at Chandigarh i/c enquiry office, CPWD, Chandigarh during 2022-23 (SH: Running Maintenance & Operation of EI & Fans, water supply system, DG Set, sub-station, fire fighting & solar through outsourcing)
RMO EI & Fans in various residential colonies located at Sector 24, 41 & 42 at Chandigarh i/c enquiry offices, CPWD, Chandigarh during 2022-23 (SH: Running Maintenance & Operation of EI & Fans, Water Supply System, DG Set, Sub-Station, Fire Fighting & Solar through outsourcing)
RMO Sub Station wetriser system water supply system water supply pumps DG Set Lift AC Units AFA and PA System at AG Punjab AandE Building Sector 17 Chandigarh. Sub Head Providing and fixing exhaust fan in toilets and panel painting and fire fighting work
Civil and Interior, Electrical, Fire alarm, Air-Conditioning System, Furniture, CCTV etc.
Replacement of Broken / Missing Float Glass of the Fire Hydrants and Fire Hose Cabinets at Various Locations in the Nehru Hospital, PGIMER, Chandigarh.
URGENT PROVIDING AND FIXING OF FIRE SAFETY EQUIPMENTS DOs AND DONTs SIGNAGES FIRE EXIT SIGNAGES REFILLING OF ABC TYPE CYLINDERS CO2 CYLINDERS AND OTHER ALLIED WORKS AT RANI LAXMI BAI MAHILA BHAWAN SECTOR-38 CHANDIGARH CH. TO REVENUE HEAD.
RMO EI & Fans in various residential colonies located at Sector 23, 24, 36, 37, 38, 39 & 43 at Chandigarh i/c enquiry office, CPWD, Chandigarh during 2023-24 (SH: Running Maintenance & Operation of EI & Fans, Water Supply System, DG Set, Sub-Station, ... Sub-Station, Fire Fighting & ...
RMO EI & Fans in various residential colonies located at Sector 23, 24, 36, 37, 38, 39 & 43 at Chandigarh i/c Enquiry Offices, CPWD, Chandigarh during 2022-23 (SH: Running maintenance & operation of EI & Fans, Water Supply System, DG Set, ... Sub-Station, Fire Fighting & ...
Customized AMC/CMC for Pre-owned Products - STORED PRESSURE TYPE FIRE EXTINGUISHER Refilling 4kg including hydraulic testing repair and provision of accessories; As mentioned in Tender Bid document; Comprehensive Maintenance Contract (CMC); As ... TYPE FIRE EXTINGUISHER Quarterly ... TYPE FIRE EXTINGUISHER Refilling ... TYPE FIRE EXTINGUISHER Quarterly ... TYPE FIRE EXTINGUISHER Refilling ... TYPE FIRE EXTINGUISHER Quarterly ...
Custom Bid for Services - providing services of SemiSkilled Helper and Operator for operation preventive maintenance of firefighting system AC Plant at Post Graduate Govt College for Girls Sector42 Chandigarh
Supplying & Laying of LT cable for U.T. Electrical connection repairing and overhauling of fire fighting & drinking water pump i/c dewatering submersible pump for RWH pit for newly constructed 28 Nos. Type-IV Quarters and 14 Nos. Type-VI Quarters at Sector 38, Chandigarh (SH: LT Cable Work)
Replacement of Damaged Fire Hydrant Supply Line in Shaft of Nuclear Medicine Deptt. of Nehru Hospital, PGIMER, Chandigarh.
1RMO S-Stn, lift, wsp, ffs, fas, ac at AG(Hr), Sec 33, Chd. 2RMO S-stn, lift, wsp, ffs, fas, ac at RDTL, Sec 33, Chd. 3RMO S-stn, lift, wsp, ffs, fas, ac at MET, Sec 39, Chd. 4RMO Electrical services at SOI, Sec 32, Chd. (SH: Refilling of fire extinguishers...
AMC for firefighting equipment installed in various building Admin block, A.C. Joshi Library, ARC Hall, Main guest house, Girls Hostel No. 3 to 7, In Panjab University Campus, Sector -14, Chandigarh.
AMC for firefighting equipment installed in various building B.M.S. 1 an 2 , Boys Hostel No.8, U.I.A.M.S., Girls Hostel No.8 to 10, international Hostel, Type-I Flats South Campus, Sector-25, Chandigarh.
Hiring of JCB machine for creating paths and zone in jungle for creating approach for fire tender in jungle area as fire preventive measures adjacent to NINE, Laundry Plant and Nursery in PGIMER, Sector-12, Chandigarh
EXTINGUISHER FIRE DEFENCE MECH FOAM 9 LTRS CAPACITY (WITHOUT CHARGE) (Q2), Portable Fire Extinguishers (V2) as per IS 15683:2018 (Q2)
REPAIR AND PERIODICAL MAINT TO FIRE ALARM SYSTEM AND CONNECTED WORKS IN OTM ACCN AT CHANDIGARH AND TBRL RANGE RAMGARH
watermist and caf fire extinguisher low pressure trolley mounted Watermist And Caf Fire Extinguisher Low Pressure Trolley Mounted ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Genric Conformity to Standards DIN EN 1866-1:2007-10 * Cylinder capacity (Ltrs) 6 6 Mounting type Trolley mount * The Trolley mounted configuration shall have water tank, compressed air cylinder and gun mounted on a free moving trolley provided with strong wheels as specified in DIN EN 1866-1:2007-08 Standards. Trolley mounted shall be supplied with two air cylinders. Yes * Pressure type Low * 1/5 Extinguishing medium Water Mist & CAF * Main components: Pressure vessel to hold the media with safety valve, Compressed air cylinder couped with a reducer, Hose pipes for discharge of water mist media, Extinguishing gun Yes * Constructional Compound Standard AFFF * Type of Foam standard foam as per ul 162 or is 4989 standards for fire rating 27 a ii b 1000 v standard foam as per ul 162 or is 4989 standards for fire rating 27 a ii b 1000 v, Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A43, II B, Spreading coefficient for special AFFF Compound shall be +5 minimum, concentration shall be 6%. The concentration of compound shall be nominal 6% Yes * Fire Rating for Trolley Mounted II B and Di Electric. With marking of Fire Class A amp; B as per EN 3-7 Standard Yes Yes Extinguishing gun material Stainless steel * Extinguishing gun weight (2000 gms approx) yes * Pressure Vessel Material Stainless steel * Pressure Vessel capacity (Ltrs) 50 * Pressure gauge to monitor air cylinder pressure Yes * Compressed Air Cylinder material Steel Steel Maximum weight of Fully Charged System 104.6 * 2/5 (kg) Performance Spreading coefficient for standard AFFF compound shall be +3 minimum Yes * Compressed Air Cylinder capacity at 300 bar(Ltr) 6 * Length of Hose(meter) 5 * The air hoses shall be suitable for minus 40 deg C to 100 deg C temperatures yes * Dynamics Working Pressure (Bar) 11 * Lancing Distance of Gun (Meter) 14.6 Any applicable numeric value Flow rate (must be in range of 0.42 to 0.50) (Ltrs per second) 0.49 * Minimum operating time in full throttle (seconds) 102 * System shall be designed for maximum operating temperature TSmax and minimum operating temperature TSmin of 60 deg C or more and 5 deg C or less respectively and certified by the manufacturer accordingly Yes * Fire Rating 27 a ii b 1000 v with standard afff compound conforming to ul 162 * Certification Commercial Brand Name of the Standard foam &(fire extinguishing medium) as per accredited laboratory test report wherein II B fire rating achieved, to be declared. AFFF 6% UL 162 * The air cylinders shall have PESO, Nagpur approval Yes * 3/5 Availability of test report to EN standard Yes * Test certificate no - * Test report date - * Name of lab where test conducted - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 PRASHANT SHARMA 160004, STATION COMMANDER, AIR FORCE STATION HIGHGROUNDS, CHANDIGARH 1 90
REPAIR AND PERIODICAL MAINTENANCE OF FIRE ALARM/FIRE FIGHTINGS SYSTEM AND CONNECTED WORKS IN OTM ACCN AT CHANDIGARH AND TBRL RANGE RAMGARH
PLC based fire alarm system (Q3) MSE Exemption for Years Of Experience Yes Startup Exemption for Years of Experience and Turnover No Document required from seller Experience Criteria, Certificate (Requested in ATC), Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer Do you want to show documents uploaded by bidders to all bidders participated in bid? No Bid to RA enabled Yes RA Qualification Rule H1-Highest Priced Bid Elimination Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days Inspection Required (By Empanelled Inspection Authority/Agencies pre- registered with GeM) No Bid Number ( ) : GEM/2024/B/5602781 Dated : 13-11-2024 Bid Document 1/5 Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No MII Purchase Preference MII Purchase Preference No MSE Purchase Preference MSE Purchase Preference Yes 1. If the bidder is a Micro or Small Enterprise as per latest definitions under MSME rules, the bidder shall be exempted from the requirement of "Bidder Turnover" criteria and "Experience Criteria" subject to meeting of quality and technical specifications. If the bidder is OEM of the offered products, it would be exempted from the "
Operation Running and preventive mtc of centralized AC Plant (120 TR),(72TR), 3 Nos, (9.5TR), 6 T.R, 405TR, 2TR,1.5 TR complete AC, Ductable AC, firefighting system fountain all operational work of PHS water supplying of sewerage pump at Tagore Theat
watermist and caf fire extinguisher low pressure back pack type Watermist And Caf Fire Extinguisher Low Pressure Back Pack Type ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Generic Conformity to EN Standards EN 3-7:2004+A1:2007 * Cylinder capacity (Ltrs) 4.7 * Mounting type Back pack * Configuration mounted on a sturdy frame suitably cushioned for comfort, provided with shoulder pads for carrying as a backpack and a handle to carrying by hand. All materials used shall be of fire retardant type. Backpack shall be supplied with two air cylinders mounted on a sturdy frame suitably cushioned for comfort, provided with shoulder pads for carrying as a backpack and a handle to carrying by hand. All materials used shall be of fire retardant type. Backpack shall be supplied with two air cylinders Extinguishing medium Water Mist & CAF * Pressure Vessel capacity (Ltrs) 9 * 1/4 Compressed Air Cylinder capacity at 300 bar (Ltrs) 4.7 * Constructional Pressure (Bar) 8.5 * Type of Foam standard foam as per UL 162 or is 4989 standards standard foam as per UL 162 or is 4989 standards, Standard Foam as per UL 162 or IS 4989 Standards, Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A43, B233, Spreading coefficient for special AFFF Compound shall be +5 minimum, concentration shall be 6%. If special foam mention the composition for special, otherwise put NA NA * Spreading coefficient for Standard AFFF compound shall be +3 minimum yes * Spreading coefficient for special AFFF compound shall be +5 minimum NA * The concentration of compounds shall be nominal 6% Yes * Extinguishing gun material Stainless Steel * if others Mentions the material for Extinguishing gun, otherwise put NA NA * Extinguishing gun weight (2000 grams approx) 1670 * Length of EN marked Hose (meters) 1.3 Any applicable numeric value Pressure Vessel Material Stainless Steel * Pressure gauge to monitor air cylinder pressure Yes * 2/4 Compressed Air Cylinder material Carbon composite Carbon composite, Ultralight carbon composite with PET Liner Weight of Fully Charged System≤ 28 (kg) 23.5 * Main components: Pressure vessel to hold the media with safety valve, Compressed air cylinder couped with a reducer, Hose pipes for discharge of water mist media, Extingushing gun yes * Perfomance Lancing Distance of Gun (meters) 14 * The air hoses shall be suitable for minus 40 deg C to 100 deg C temperatures Yes * Flow rate (ltr/sec) 0.42 * Operating Temperature Range - TSMax >= 60 deg C, TSMin = 5 deg C Yes Yes Operating time in full throttle Must be in range of 20 to 23 (seconds) 21.7 * Fire Rating 27 A, 233B, 1000V with Standard AFFF Compound conforming to UL-162 27 A, 1000V with Standard AFFF Compound conforming to UL-162, 43 A, 1000V with Special AFFF Compound as per manufacturer own specn. certification Commercial Brand Name of the Special foam (fire extinguishing medium ) as per Accredited Laboratory Test report where in fire rating has been achieved, to be declared. ASKA FX AFFF * The air cylinders shall have PESO, Nagpur approval Yes * 3/4 Test certificate no - * Test report date - * Name of lab where test conducted - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 PRASHANT SHARMA 160004, STATION COMMANDER, AIR FORCE STATION HIGHGROUNDS, CHANDIGARH 1 90
As per NIT
As per NIT
fire proximity suit (Q2), Inherent Fire Retardant Overall for firefighting and rescue purpose ( Protective coveralls) (Q2)