Renovation of damaged radiator and rep. of radiator and oil cooler fan motor (02 Nos.) and rep. of motor fan housing with hole and tap threading work, catwalk platform making and complete repairing making of mast resting platform with fitting OF 752
For repairing of rotary head housing gear (LHS and RHS) , straightening of bend chain roller links (LHS and RHS) and cutting welding machining of Pins ( 02 Nos.) of pulldown cylinder of Drill (REL-512) Sl. No. DR-245 at AKWMOCP, KATRAS AREA, BCCL
Repairing of hydraulic oil cooler, fuel tank and its mounting, rod bush guide, repairing of air cleaner housing and its foundation and repairing of bearing block assy. (LH and RH) and leveling jack assly. of IDM-30 Drill Sl.no. RDC1288 of Sirka Colli
Repairing of HEMM Model-WS-28-2Water sprinkler, CIL No.WS-173, Sl. No.WT-301 of Jarangdih Colliery. (A) Repairing of damaged engine guard and transmission guard. (B) Repairing of rear (RHS) 2 nos. damaged arm radius eye housing by welding and grindin
Repairing of HEMM M/c. No.BH60M Dumper, Sl. No.D-60388 of Jarangdih OCP. (A) Repairing of damage arm radius eye housing by welding and grinding new bush pressing and pin repair. (B) Repairing of rear drive shaft assembly, cross changing and guard rep
Repairing of Rear wheel hub both sides, Repairing of front right side suspension sup-port, Replacement of left side Hoist cylinder, and Removing the anchor pin, worn out bush and repairing of anchor pin housing and fitment of Anchor bushing and pin.
Repairing of Bucket assly of BE1000-1 Shovel Sl No. 10146 and repairing of Disttorted RHS idler plate housing and hard surfacing of both side idler coller and repairing of worn out both side sprocket teeth of CK300 Shovel Sl No. E-170.
Repairing of arm housing bucket pin portion crack repairing bush place damage bore repairing bore std size 150x140 mm steel bush new making 150x130x140 mm 2nos pin welding machining 130x160 mm both side pin lock cutting and welding of TATA HITACHI 6
Repairing of pedestal bearing housing and replacement of damaged propel shaft with new propel shaft and repairing of driven half coupling and slider jaw disc both side and 01 no. LVCR assy. of EKG 5A Shovel SI No. HMB-560, CIL No. 2640.
Line Boring of Arm and Bucket attachment, H-link, side link worn out eye housing, fabrication and fitting of bush in arm and H-link, repairing of worn out pins of BE- 1000 Shovel, Sl. No.- G-10222 of AMP colliery, Barora Area.
Repairing of radiator grill, radiator guard, rail path, platform and railings, side guard of engine, LHS RHS light post, upper and lower hitch articulation assembly housing, LHS RHS lift cylinder 04 no. mountings and eye, etc of CAT 988H PL1 at AOCP.
Repair of track pads, pins and replacing with serviceable track pads, rebuilding of pivot shaft by material deposition and making of 24 no holes, pivot shaft chassis housing by machining and line boring and pressing of 06no. Bushes, etc of D3 Dozer
TOP HOUSING for Constant Contact Poly Urethene (PU) side bearer pad of BOXNHL wagons as per Drg.No.AAL-021101, Alt 08, Item no.01. Material as per drawing and conforming to RDSO Spec WD-38-Misc-2004 (Rev-3) of Apr-25 (Design -A).
A)Replacement of 19 nos.damaged 6inch pipes after removal,dismantling,cleaning and transportation of the same from CHP to new quarters at Tetturya Colliery B)Replacement of 8Nos. damaged 4inch pipes near Tetturya colliery office under Govindpur Area.
Day to day maintenance of water distribution system (External an Internal), sanitary system and cleaning of different PVC water storage tanks located at roof of quarters and office buildings and RCC overhead water storage tanks, underground water res
Repair of damaged roof of W.C. bath in the two nos quarters. Employees of Sawang Govindpur Ph II at 1C type colony 1 Sri Gudu Kumar Mining Sirdar RC 01 2 Sri Mangal Hemram qrt no RC 4.
Repairing and maint.of pipeline of qtr no B-78,B- 56,B-223,B-44,B- 110,D-13,C- 109,C-150 and pipe in MT hostel and different Quarters at NNTS Harina under Block-II Area
Repair and Maintenance of 03 nos. block of four storied B type Quarters (i.e. 48 unit B type Qtrs. in block no. 06, 07 and 08) in CISF B type Colony at Dakra under GM Unit, NK Area.
Complete repairing / overhauling of 06 nos. split and 04 nos. window Air conditioner machine installed in different section and repairing / rewinding of ceiling fan of employees quarters as well as rail and road weighbridge, canteen, R/Store, Office
Custom Bid for Services - Patch Electrical Repairing Rewiring of DVC Quarters Office buildings Hospital School etc at Maithon Right Bank and Left Bank Colony under CPH Division DVC Maithon for Two Years Similar Category Repair and Overhauling Service
ROTOR ASSY; F/FL LIQ PUMP; MM: SCS 300/470, BRG HOUSING; DRIVE END; MM: SCS 300/470, BRG HOUSING; NON-DRIVE END; MM: SCS 300/470
Repairing of pin of Hoist jack, tyre rim, making of rear suspension pin in true size, making of eye holes, repairing work i.e AC element housing, suspension pin, making of eye pin, fitting of bushing, extraction of bolts and hub repairing for Komatsu
Composite Office Tables confirming to IS 8126 (V2) (Q2) ( PAC Only ) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller OEM Authorization Certificate, Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? No Bid to RA enabled No Type of Bid Two Packet Bid Primary product category Composite Office Tables confirming to IS 8126 (V2) Time allowed for Technical Clarifications during technical evaluation 2 Days Bid Number : GEM/2025/B/6373522 Dated : 23-06-2025 Bid Document 1/6 ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Steel Shelving Cabinets (Adjustable Type) confirming to IS 3312 (V4) (Q3) ( PAC Only ), Office Chair (V3) (Q2) ( PAC Only ), Revolving Chair (V4) (Q2) ( PAC Only ) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? No -- Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2025/B/6419584 Dated : 05-07-2025 Bid Document 1/9 Bid to RA enabled No Type of Bid Two Packet Bid Primary product category Steel Shelving Cabinets (Adjustable Type) confirming to IS 3312 (V4) Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
Procurement of One Dewatering pump along with pipes and accessories atSouth pit of Talaipalli Coal Mining Project.
Supply and Installation of Prefab Security cabins at Talaipalli CoalMining Project
Renovation of Shiv- Temple at Chatti Bariyatu, CBCMP Projecteffected village
Supply and installation of Solar panel , inverter , battery andenclosure box - 3 Quantity for providing power supply to PTZ camera andCambium wireless device mounted on 15 mtr tower for Talaipalli CMP
Procurement of Cables for Coal Mining Project Hazaribag.
Procurement of HSD in the vicinity of site for operation of DG sets in different locations of PakriBarwadih CMP ChaattiBariatu Coal Mining Projects
Procurement of Lab equipment Universal Testing Machine with complete assembly for PBCMP.
Consultancy Work for Rendering Quality Assurance and Inspection services on behalf of NTPC Limited on Single Tender basis
(I)Upgradation/modernization of infrastructure at existing Goods shed at GUMI (Gorumahisani) Station. (II) Construction of 02 units type II quarters at Bahalda Road. (III) Upgradation/Modification of RPF Barrack at SINI under the Jurisdiction of Sr.DEN/East/CKP
Complete Rewinding of 01No. 550/440V, 100KVA Transformer Sl. No. T/C-05TR at New Quarters Colony and 01No. 550/220V, 25KVA EMEI make Transformer Sl. No. KT20/69 at Marwari Kothi of Tetturya Colliery under Govindpur Area-III
A) Repairing and changing of 300KVA-3.3KV-550Volt oil cooled transformer, Sl. No. WNP, Installed at 9.0. Colony maintenance under Kathara Colliery. B) Installation and commissioning of earth pit G.I. Wire at 28 nos. Employees Quarters i.e. Office Col
Repair and maintenance of 09 nos. Quarters, MQ-991, 1CR-20 at Gidi-A Colony and MQ-28, PD-124, ST-02, ST-10, LCH-26, BRK-13 and VT-06 at Religara colony under Religara Project, Argada Area.
Rewiring of internal electrical house wiring, changing of service wire and making of earth pit of DAV teachers quarters Qtr. No B/09, B/10, B/11, B/12 and 1B/68 quarter at staff colony of Kathara Colliery
Electrical repairing / re-wiring and changing of electrical items of different types of executives quarters no. Qtr No. 2A/22, 2A/6, C/25, C-8, C/1, B.M.S Office and Staff Recreation Club, Kathara under G.M Unit Kathara
Repairing and Maintenance of 08 Unit NHS type Quarters at Mahul Bagan colony (Qtr. Numbers are-NHS-NHS/33/-290,291,292 and NHS/8/64 , NHS/12/93, NHS/24/224, NHS/03/17 and NHS/03/20) Under ROCP.
Repair/replacement of damaged service cable, junction box, bus-bar box situated in campus M.Q. Type quarters block no.15 to 27 to provide constant voltage supply upto user end for safety of persons and electrical equipments under CCD
Repairing, rewinding and maintenance of 40 nos. ceiling fans installed at various locations like store 7/8 and 4/5/6 incline office building, dispensary, P.O office canteen and officers quarters etc. under Dhori(K) Colliery, Dhori Area, CCL
Brooming and cleaning of roads, Yoga Mandir complex Tennis court, Parks, 70 nos quarters, roof cleaning, cleaning of toilets, septic tanks, inspection chambers, drain and garbage cleaning for a period of 12 months at Jawahar Nagar Colony, CCL, Ranchi
For Electric House 10 Nos. Quarter NTD-218231, 243,251,186,132,84,282, 322 and NTT-541 A Type NPTS,(ii) Qtr. No. C-Type of Sri Dinesh Kumar Bhuli Township (iii) B Type Qtr. No.B/20 of Sri Giridhari NPTS (iv) 04 Nos. Qtr. No. 30,12D, 121,and 12
IMPELLER WITH SHAFT FOR FD FAN, Bearing Without housing, Bearing Housing without bearing, Shaft Seal, RESILIENT TYPE FLEXIBLE COUPLING, IVC DAMPER WITH LINKAGE WITHOUT ACTUATOR, Inlet air Filters
Repairing of Opening of 06 nos broken bolt thread making and new stud and nut fitting of hub assly of dumper sl. No.3523 and broken bolt thread making and bolt fitting of mobile filter housing of W/Tanker -440 of KOCP,BA-IX
Repairing/rebuilding of damaged and worn-out rack segments teeth of 75 Nos. and rebuilding worn-out dipper eye both side of EKG-5A Shovel and Repairing/ rebuilding of damaged and worn-out roller housing by suitable EKG-5A Shovel Sl. No. Exc-2859 o
Removal of worn out bearing of upper hinge and lower hinge also fitment of new bearing with making the both housing as per bearing size also lower bearing portion base plate cutting and fitment another plate of 988H CAT Pay Loader Sl. No. BXY 2878
Repairing and denting of A.C element housing 04 Nos precleaner element 02 Nos , connected air pipe, propeller shaft guard 02 Nos, element panel door and walling floor plateform in REL 650 Drill Sl.No. DR-240 and DR-241 of Kuya OCP, Bastacolla Area IX
Repairing of 6UP-4 Pump 150/100, Make-Kirloskar, 1000 GPM and 90 m Head by changing its shaft sleeve, bushes, bearing housing, neck ring etc. kept at new pump house of intake riverside for feeding raw water to filter plant under Kathara Colliery.
(1) DISMANTLING OF BROKEN SHAFT AND NEW SHAFT MAKING AS PER BROKEN SHAFT AND MOTOR HOUSING BROKEN BOLT OVER SIZE DRILLING AND ROTOR AND END COVER FITTING OF 150 HP INDUCTION MOTOR SL.NO.86/83/115. (2) DISMANTLING OF BROKEN SHAFT AND NEW SHAFT MAKING