Providing, Installation and Testing of Demand Controller with maximum demand sensing unit on both Sayal 33 KV SF6 Breaker Control Panel and Urimari SF6 Control Panel at 33 KV substation at site.
Fabrication and erection of HT and LT bus bar arrangement with structure including manufacture/supply of 03 nos. 800 A, 440 V, ACB at IWSS substation under CCD, GM Unit, Dhori Area.
Replacement of cable jointing kit/pole mounting with fixing of GI strip for earth pit at weighbridge and replacement of faulty Lightening Arrestor with the new one 33KV substation, DBOCP, CV Area
Repairing/ rewinding of 315 KVA (3.3KV/550V), FLP Trans Switch Unit, Sl.No. 658211, make- MIKOLOWSKA FABRYKA (made in poland0, installed at Ray substation under Township (Bachra), Control of GM Unit, PPR Area.
Repairing of fencing wire of 100 kva transformer installed at R.S. Bhatta and fencing wire of substation installed at EnM section and repairing and painting of M.S./G.I. main gate under SDOCM
Maintenance of 33kV Tie Line with replacement of 01 No. damaged TP structure and earth wires of 33kV OH Tie Line in between new and old Substation of KDH OCP, NK Area
Establishment, strengthening, designing and commissioning of Nitrogen injection fire protection system for 02 nos. oil filled transformers 7.5 MVA, 33/11KV, sl no. 3355 and 3354 installed at substation of Kathara Washery
Repairing of one no. 11KV 400 amps, ECE make OCB, Sl. No.-PnM 08, standby of primary control of AKKOCP line installed at DD Mines Substation of Bokaro Colliery under BnK Area
The Heat shrink 3 number, cabling lead fabrication,3 number of earth pit for the new Installation of transformer at OCP substation and other LT line related miscellaneous work at Ena Colliery
Repairing and tensioning of damaged sagged 440volt overhead line along with replacing of damaged tilted poles and insulators from Karmatand substation to Ramgarh Jharia Kashmir colony for safety purpose at Damoda Colliery
Repairing and rewiring of 250KVA , 11KV/440 volt Oil cooled Transformer, name plate Missing Local Sl. No.Ray TH/1, installed at Ray Substation under Bachra Township Control of GM unit, Piparwar Area.
Complete repairing/renovation of one 11 kv 630 A GEC make VCB sl.No.8231341/B/27 and one 11 kv 1250A GEC make VCB (sl.No.823134/B/09) at South Loyabad substation
Extension of 3point3KV overhead line from Muraidih substation to river side for power supply to 1000gpm pump motor set and dismantling of idle overhead line for safety purpose at Muraidih AMP Colliery
Complete repairing, rewinding and re-installation after repairing of 1 MVA 11KV/3.3KV Transformer Century make Sl. No. 425/13-14 installed at main substation of Kedla UG project under Hazaribagh Area
Repairing of 550V O/H line from 9 seam substation to 10 seam borehole and 220V O/H lighting line from HZL O/H line to Jogidih P.O office in Jogidih Colliery
Complete repairing and maintenance and overhauling of out door type VCB 33KV 1250A 3 phase Sl. No 17505 p3 Make ALSTOM Ltd. Naini works of Regional Substation Sudamdih shaft under ASP Colliery.
Supply, installation, commissioning and testing of ICTP Switches at Welding Room, Gandhinagar Substation and C.I.S.F. Residential Colony, required for replacement of the existing faulty ICTP Switches, w.r.t. Bokaro Colliery, under BnK Area.
SHIFTING OF 500 KVA TRANSFORMER 6.6 KV/440 VOLT INSIDE THE ROOM ALONG WITH STRAIGHT THROUGH JOINT OKF 240 SQ MM CABLE AT GASLITAND SAMADHI STHAN SUBSTATION GASLITAND, AGKCC UNDER KATRAS AREA
Supply and installation of 11 kV and 3.3 kV grade outdoor type 3 phase horizontal rotating type Auto Re-closing Isolators at the Karo Main Electric Substation under Karo OCP, BnK Area
Diversion, erection, dismantling of 3.3KV and 440V OH line along with making of foundation shed, etc for 3.3KV and 440V Switch gears at new workshop substation of Karma project under Kuju Area.
Renovation with heightening and making of Bus bar as per minimum ground clearance with Bus pipe System on 11KV side for proper power supply arrangement at substation of KUGP under Hazaribagh Area.
Renovation of existing bus bar arrangement and providing and fixing new bus bar arrangement for feeding power to existing transformer along with structural work at 12 no. substation of AADOCM, Dhori area
Reinforcing along with maintenance of 440V, 4 wire Lt OH power line with fixing of phase separator and erection of cradle guard from dam colony Substation to Camp under JOCP Hzb area
Testing of 33 kv 6.6 kv CTs by Primary injection set for relays effectiveness testing and also issuing test certificate for record at 33 kv Sudamdih shaft mine Substation under ASP Colliery
Cleaning, Repairing and renovation of existing cable trench for different size and grade of power cable and control cable for safety point of view in premises of Khasmahal Substation of BNK Area
Supply and installation of 4 sets Ab switch and 4 sets interlocking arrangement in 3.3KV O/H no 02 and 3PIT O/H controlling of breakers under 11KV substation and ABNS colliery
Repairing, providing and fixing of MCCB- 02 nos, 03 pole (630 amp 50KA-01 no and 250 amp 25KA- 01 no) of Substation at RRS (NK) Dakra under GM Unit (NK) Area
Repairing of HT (3.3kV) and LT (440V) control switchgear of 750kVA, 3.3kV/440V TSU, Sl. No.- 9357, Make- Meditron installed at 22.5MVA, 33kV/11kV-3.3kV Old substation of KDH OCP, NK Area
Rearrangement of proper power distribution by installing 03 nos of 630A MCCB DTH for Main Substation and other locations for power supply to mines and workshops at Topa OCP under Kuju Area
Diversion of electrical poles (11KV line) feeder no-2 along coal transportation road (width 7 mtr) being built by CCL from chopra more to near substation of KUGP under KUGP, Hazaribagh Area.
Repairing and maintenance of two nos. of 1 MVA, 11 kV/3.3 kV Power Transformer installed at 4, 5, 6 incline and 7/8 incline substation of Dhori (K) under Dhori Area.
Repairing of one no. Neutral Grounding Resistor 3.3 kV grade, 10 Amp to limit and protection of grounding current to 10 Amp, installed at D.D. Mines Substation, under Bokaro Colliery, BnK Area.
Diversion of 3point3KV and 220volt overhead line due to OB dumping at albion OCP and heat shrink in 11KV and 3point3KV grade indoor and outdoor cable of albion substation of Damoda Colliery
Repairing of OCB Switch of Make GEC, 800A,550V/440V, Sl. No. OCB/440/12 to be installed at the Secondary side of Transformer of 5 Pit SubStation of NAKC under GA.
Repairing of lights of Shatabdi workshop shatabdi substation shatabdi filter platn view point and front side of SOCP attendance room premises through providing and fitting of light set under Muraidih AMP Colliery
Providing, installation, commissioning, testing of 04 Nos. of GOAB switch and providing interlocking arrangement between 08 Nos. of GOAB switch and corresponding switchgear installed at Dakra Substation under Dakra OCP, NK Area
Installation of rectifier system in 07 nos. of 11KV/3.3 KV VCB, 630 Amp and 400 Amp VCB Make Meditron and Mineline respectively at main substation of Karma Project under Kuju Area.
Dismantling of idle 3point3KV overhead line at Ganeshpur substation and extension of 3point3KV overhead line at Jarlahi pump section for feeding power to Jarlahi pump motor set of Phularitand under AMP Colliery
Selective Tree trimming including cutting of branches and uprooting vines near 440V/220V and Cleaning Grass, vegetation and removable of rubbish after monsoon for substation and nearby area. at RRSTN Under Hazaribagh
Complete overhauling of 33KV/1250 Amp VCB breaker, make- Electro Technica, Sl. No.- 900251 for control of CPP 33 KV feeder (Extension) a stand by provision at Regional Substation under Kathara Colliery.
Providing/making a lightening arrestor and new earth pit, connection with GI strip at different electrical equipments and installation at Rail In-motion, Road Weighbridge, different substation and location of Sawang Washery.
Repairing / rewinding of 315 KVA /3.3KV/550 volt , FLP Trans switch unit Sl. No.FTS-068, make-Electrotechnica installed at 01 no. Mine substation under Township(Bachra) Control of GM unit, Piparwar Area.
Complete repairing of Prabhu make FLP type VCB switch 3.3KV/400 Amp. SL No.180, type ELP, VCB-01 primary control of 1250 KVA Transformer installed at Dakra Substation under Dakra Project
Repairing and rewinding of 1.25 MVA / 11KV/3.3KV, Oil Cooled Transformer, Sl. No.120186, make- Windpower Hindustan Pvt. Ltd., installed at Ray Substation under Township(Bachra) control of GM unit, Piparwar Area.
Upgradation of 1MVA X 3 3 MVA , 11KV/3.3KV CRS Electrical Substation along with Enamel painting of electrical equipments and proper marking of control panels at 11KV/3.3 KV CRS, Barkakana ,CCL.
Dismantling and erection of 440V line at Mauserwa village and near temple of Rabodh patch with provision of lightning arrestor at pumping station and mine substation at Pindra Project under Kuju Area.
repairing/reconditioning of 6.6KV, 630A VCBs with Sl. No. 3421, 3422, 3423 make Andrew Yule at 2x12.5MVA, and sl.no. SP/O/1264, make- Electrotechnica at 33KV/6.6KV main substation of Rajrappa Project.
Erection and Maintenance of lightening arrestors at Pumping Station and AKKOCP Substation including the maintenance of Earth Pit arrangements for smooth and reliable power supply and pumping operation during monsoon at AKKOCP
supply and fixing of digital protective and metering devices in control panels of 33KV, 6.6KV, and control desk installed at the panel room of 2X12.5MVA, 33KV/6.6KV main substation of Rajrappa Project.
Diversion of 6.6 KV O/H line due to OB Dumping in Jarlahi face to feeding power of 4000 GPM Motor pump and repairing, maintenance in SOCP Substation under Muraidih AMP colliery.