Loading…
Loading…
815 results • Best match
20A 3.6KV High voltage HRC fuse link, Ca20A 3.6KV High voltage HRC fuse link, Capacity-20A, Bolted type, 3.6KV AC, Breaking Capacity-40-50KA, Off-Set tag, Closed Slot similar to cat. No. 3.6WDOHS20 of Make: Eaton-Bussmann or cat no. 3.6K3PG20 of M/s. ... main transformer 9KVA, ...
20A 3.6KV High voltage HRC fuse link, Ca20A 3.6KV High voltage HRC fuse link, Capacity-20A, Bolted type, 3.6KV AC, Breaking Capacity-40-50KA, Off-Set tag, Closed Slot similar to cat. No. 3.6WDOHS20 of Make: Eaton-Bussmann or cat no. 3.6K3PG20 of M/s. ... main transformer 9KVA, ...
WINDOW TYPE CT, 800/1A, 11KV, WINDOW TYPE CT, DUAL CORE, 800/1A, 11KV, CURRENT TRANSFORMER (METERING), WINDOW TYPE CT, 800/1A, 11KV, CLASS PS, DRAWOUT TYPE PT, DUAL CORE, 11KV, DRAWOUT TYPE PT, 11KV, 3P/0.5, 75VA, DRAWOUT TYPE PT, DUAL CORE, 11KV, CL ... CURRENT TRANSFORMER 100/5-1A
TRANSFORMER, FET, DIODE, MC Digital High Speed Driver Type SG 1626Y, Transistor Type STB IIN B40T4, Cap Fix 220UF Plus Oblique Minus 20 Percent 250V
Redeveloping,renovation of pvc u/g distribution system and supply of pvc pipe and accessories, repairing of spout chamber, control room, lt panel, transformer etc.
Custom Bid for Services - Testing, Calibration and audit facilitation of electrical utilities at Siliguri Marketing Terminal, NRL Quote for SOR Line Item 10 Filtration of transformer oil-1600 KVA, Custom Bid for Services - Quote for SOR Line Item 20 ... of transformer - ... of transformer oil-1000 ... of transformer - ... of transformers , ... of transformers , ...
Construction of 11KV dedicated line along with installation of 500 KVA transformer for power supply to Garrison Engineers, Air force, Charingia Gate, Jorhat under Deposit work scheme
Supply of Mair Breather Kit for Vande Bh [Supply of Mair Breather Kit for Vande Bharat TS Coach Transformers, Each Kit containing 1 nos of Air Dryer-Big part for JST Article no-1066209R000, 1 nos of O ring gasket dia. 5.33 int 66.04 JST Article no. 1075895R000, 4 nos of screw HM 12-60 A4 80 JST Article no. 1056029R00, 4 nos of washer LE 12 A4 JST Article no-1051768R000, 4 nos of washer M 12 A4 JST Article no. 1044330R000 4 nos of Nut H dia, M12 A4 80 JST Article no. E032405 Firm s.]
Insulating Oil For Transformer As Per POWERGRID TS (Q3) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Certificate (Requested in ATC), OEM Authorization Certificate, Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? No -- Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 7 Bid Number : GEM/2025/B/6557278 Dated : 13-08-2025 Bid Document 1/6 Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 3 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Payment Timelines Payments shall be made to the Seller within 30 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC) Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
COIL ASSY FOR GEN SET, AVR FOR GEN SET, DIODE PLATE FOR GEN SET, BEARING FOR GEN SET, FIELD COIL ASSY FOR GEN SET, TRANSFORMER FOR GEN SET
Custom Bid for Services - Design, Engineering, Supply, Installation, testing And Commissioning of High Velocity Fire Water Spray System For Grid Transformer At Bongaigaon Refinery Similar Category Support Services
100 VA Step down Transformer 750/110 V AC, H class insulation with 2 nos. 1 Amps, 1.2 KV AC HVfuse and base both in Primary as well as in secondary side Suitable for LHB Non AC Coaches conforming to RCF Spec no. EDTS 355 Rev.1 Amendment no. 2. . Make:- Bhasin / Vimal / Ramyaa. Note: Firm should supply proof of purchase from OEM or Authorized dealers only.Firm should supply test certificate & guaranty certificate along with supply of item.
100 VA Step down Transformer 750/110 V AC, H class insulation with 2 nos. 1 Amps, 1.2 KV AC HVfuse and base both in Primary as well as in secondary side Suitable for LHB Non AC Coaches conforming to RCF Spec no. EDTS 355 Rev.1 Amendment no. 2. . Make:- Bhasin / Vimal / Ramyaa. Note: Firm should supply proof of purchase from OEM or Authorized dealers only.Firm should supply test certificate & guaranty certificate along with supply of item.
100 VA Step down Transformer 750/110 V AC, H class insulation with 2 nos. 1 Amps, 1.2 KV AC HVfuse and base both in Primary as well as in secondary side Suitable for LHB Non AC Coaches conforming to RCF Spec no. EDTS 355 Rev.1 Amendment no. 2. . Make:- Bhasin / Vimal / Ramyaa. Note: Firm should supply proof of purchase from OEM or Authorized dealers only.Firm should supply test certificate & guaranty certificate along with supply of item.
Survey, Construction of PVC Distribution System, Spout Chamber, Goat Proof Boundaty Fencing, Approach Road, Controll Room, Boring installation of DTWS, Const HT/LT Line, Transformer, Panel Board, Energy Security etc.
Survey, Construction of PVC Distribution System, Spout Chamber, Goat Proof Boundaty Fencing, Approach Road, Controll Room, Boring installation of DTWS, Const HT/LT Line, Transformer, Panel Board, Energy Security etc.
TR 547, TR 557, IRF 4710, TR 5819, VICOR 48S 48 VND 30, DC DC VICOR, OSCILLATOR 10 MHZ, IC 78HB5, IC 74 HC 4051, TRANSFORMER, RELAY 3.3 V 250 VDC
Electrical UpGradation of transformer DG Set Electrical Panels at backside substation of hospital at Dr B Borooah Cancer Institute under sanctioned project of Strengthening of BBCI with renovation refurbishing retrofitting works
Supply, Installation, Testing and Commissioning of 01 number 800 KVA, 11/0.433 KV, 3-phase, Oil Filled, ONAN, Outdoor type Unit Auxiliary Transformer for Karbi Langpi Hydro Electric Project, APGCL, Lengry, Karbi Anglong
66 kV Potential Transformer for Sub-stations/Power Houses (PSPCL) (Q3) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Certificate (Requested in ATC), OEM Authorization Certificate, Additional Doc 1 (Requested in ATC), Additional Doc 2 (Requested in ATC), Additional Doc 3 (Requested in ATC), Additional Doc 4 (Requested in ATC), Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? No -- Minimum number of bids required to disable automatic bid extension 3 Bid Number : GEM/2025/B/6377373 Dated : 29-07-2025 Bid Document 1/8, -- Number of days for which Bid would be auto -- extended 7 Bid to RA enabled No Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 3 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Advisory Bank State Bank of India EMD Amount 26000 ePBG Detail Advisory Bank State Bank of India (%) ePBG Percentage(%) 5.00 ( ) Duration of ePBG required (Months). 20 (a). EMD EXEMPTION: The bidder seeking EMD exemption, must submit the valid supporting document for the relevant category as per GeM GTC with the bid. Under MSE category, only manufacturers for goods and Service Providers for Services are eligible for exemption from EMD. Traders are excluded from the purview of this Policy. (b)., EMD & Performance securityshould be in favour of Beneficiary, wherever it is applicable. Beneficiary : POWERGRID Power Grid Corporation of India Limited Central Procurement Cell, Plot No. – 2A/INS 02, Avadh Vihar Yojna, Amar Shaheed Path, Near Medanta Hospital Lucknow- 226002 (UP) (Power Grid Corporation Of India Limited) 2/8 Splitting
Construction of 11 KV Line alongwith Installation of 11/0.433KV, 1x 100 KVA transformer in favour of Director, M/S Borhomthuri Private Limited, Vill-2 No Srihati, Sualkuchi Kamrup Under Guwahati Electrical Circle-II
Maint/MMPPNA/2023-24/185_Construction of road from Barbari Durga mandir Paikarkuchi _Kamarkuchi road to Barmurikona Pagladia Bridge Nalbari kamarkuchi road_ Nalbari Kamarkuchi road to Khudra Kulhati via Siva Mandir road _Bangalmur Transformer to Khud
Improvement of IB and office campus at Amingaon including construction of boundary wall, Internal Roads and parking, Chowkidars and care takers quarter, security booth and transformer pad under SOPD-G for the year 2019-20
EPOXY painting of 33KV as per item 1 of attached specification document, CT PT SPOUT and BKR housing as per item 2 of attached specification document, 630 KVA 415 KV dry type transformer as per item 3 of attached specification document, 800 KVA oil ... type transformer as ...
Repair/ maint/ servicing of transformer installed at HQ IGAR (E) Srikona, repair/ maint/ servicing of highmast lights, control panel and connected accessories at HQ IGAR (E) Srikona, Cleaning of PVC over head (OH) water storage tanks in resdl and no
Substation Package-SS77 associated with (i) Augmentation of 220/132kV Salakati s/s including 1x100MVA, 220/132kV transformer under NERSS-XI ii) Extension of 220/132kV Salakati s/s under NERSS- XII iii) Extension of 220kV BTPS Substations under NERSS-XII
A Set of Silicon Rubber Gasket "O" Rings suitable for Transformer Oil Cooling Pipes (Metallic Pipes) Flange Type - A,B,C,D,F,G,K,L & M to ABB ID No. 3EHN 424150 for WAG-9 loco, as per ELS/AJNI's Sketch No. ELS/AQ/WAG-9/SK.NO. 0033, Rev-02 or latest and confirming to CLW Spec. No. CLW/ES/3/0142, Alt-H or latest. (This is shelf life item and should be procured with staggered delivery period. Supplier to mention/print date of manufacturing on the item & item to be supplied within 90 days of manufacture date.)
SPL REPAIRS/REPLACEMENT OF 11 AND 33 KV PIN/DISC TYPE PROCELAIN INSULATORS, GOD, DO FUZE WITH RESPECTIVE POLYMER TYPE MATERIALS AT MRS AT LAXAM MARG AND OVERHAULING/REPAIR TO TRANSFORMER, VCB, AND CONNECTED ITEMS AT MISA CAMP UNDER GE (S) TEZPUR
. If L-1 is non-MII and H-1 is eligible MII and H-1 price is coming within price band of 20% of Non-MII L-1 Power Supply, Transformer With Rectifier And Fuse 100V, Power Fuse Holder Ti Line Cord Receptacle, Xenon Spare Lamp 300w, 15V
Servo System 320, Servo System 121, Servo Mesh SP 460, Servo System 68, Gear HP, Servo Coat 120, Servo Coat140, Servo MG 20W40, Grease MP, Grease EP2, Grease WB, Grease HTXX, Hydraulic Brake Fluid, Transformer Oil, Gear Oil TH 46, JCB Transmission Fluid, JCB Rear Axle oil, Servo MG15W40
Operation and maintenance of Electrical and Mechanical installations, Job contract for Operation and Day to Day Maintenance Services of Airport Systems equipments, Execution of item of Schedule of rates CPWD DSR 2022 as and when required, Testing of ... of Transformer oil ... of Transformer oil ... kVA transformer , ... of Transformer Oil ... KVA transformer etc. ... Isolating Transformer , ... KVA Transformer
SEMICONDUCTOR DEVICE DIODE TYPE TVS IH6, HMC THK RF AMP MAR 3SM, HMC THK FLTR BPASS BMC 1527, MICROCIRCUIT LINEAR TYPE 3727, MICROCIRCUIT SPST ANALOG SW TYPE MAX 4626, SENSOR QRB 1113, IC GATE NOR 14SOIC 74 HC 02, TRANSFORMER POWER STEP DOWN PRIMARY 23, IC 27C 256 PROGRAMMED, RELAY ELECTRO MAGNETIC DPDT 2A 12V1
AC TO DC CONVERTER PCB 1, DC TO DC CONVERTER U3, DC TO DC CONVERTER U8 PCB 3, DC TO DC CONVERTER U7 PCB 4, EMI OBLIC FILTER EMC CARD, TRANSFORMER T1, CAPACITOR 330 MF 440V, SWITCH DPST, CONNECTOR P4 P5 P7 P8, BODY COVER, DC FAN 12 V, LED 3 V, AC POWER CORD, FUSE ASSEMBLY, DC POWER CORD
M SEAL, THREAD TAPE, ARALDITE, ELECTRODES WELDING STEEL ARMOUR 3.15MM, FLEX QUICK, SOLDRING WIRE, INSULATION TAPE, SOLDRING PASTE, EMERY PAPER, BTY 9V, DESOLDRING WIRE, GLU GUN STICK, BTY 1.5 AAA, BTY1.5 AA, ON OFF SWITCH, TOGGLE SWITCH, STARTER PUSH ... BUTTON, TRANSFORMER 12V, ...
IC PROGRAMMED Z8, MICROCIRCUIT LINEAR TYPE TDA 440, IC CA 3100T, TRANSFORMER T2, MICROCIRCUIT LINEAR CP QUAD TYPE MC-3303, FUSE 5A 250V, REGULATOR DIODE 12V, SEMICONDUCTOR DEVICE DIODE ZENOR TYPE BZ, TRANSISTOR NPN TYPE BC P56-10, SEMICONDUCTOR DEVICE DIODE TYPE TVS IH 6063 A, RESISTOR FIXED FILM 243K OHM 1 0.25W, RELAY 3.30 VDC 250VAC TYPE 70S2- 04-0-06N BOQ Title ORD BOQ BID NO 26
Chlorine dioxide for treating drinking water, Alum ferric Gd II, Bleaching Powder Gd I, Alum Crystal Non Ferric, STP Culture Liquid, Copper Sulphate Crystal, Cord flexible copper 23X0076 Flexible wire, Cord flexible copper 40X0076 Flexible wire, PVC ... Sqmm, Transformer oil, ...
Internal Combustion Engine Lubrication Oil As Per Is: 13656- IS: 13656 (Q2), Industrial Gear Oil as per IS: 8406 (Q2), Gear lubricants, Multipurpose as per IS:1118 (Q2), Cutting Oil, Soluble as per IS:1115 (Q3), Lithium Base Grease for Automotive ... (Q3), Transformer Oil ...
27CS12R, MICRO CCT 9410 SMD, MC DGTL TYPE NAND 74HC 00, CAP FXD ELECTROLYTIC DIELECTRIC 22UF 35V, CAP FXDED PAPER DIELECTRIC 0.6UF 250VDC, IC PROGRAMMED Z8, MICROCIRCUIT LINEAR TYPE TDA 440, IC CA 3100T, TRANSFORMER T2, MICROCIRCUIT LINEAR CP QUAD TYPE MC-3303, FUSE 5A 250V, REGULATOR DIODE 12V, SEMICONDUCTOR DEVICE, TRANSISTOR NPN TYPE BC P56-10, SEMICONDUCTOR DEVICE DIODE TYPE TVS IH 6063 A, RESISTOR FIXED FILM 243K OHM 1 0.25W, RELAY 3.30 VDC 250VAC TYPE 70S2-04-0-06N BOQ Title ORD BOQ BID NO 11
FLUID WATER BASED HYDRAULIC, OIL SYNTHETIC TES-295 GRADE FOR ALLISON*, OIL MOBIL DTE 10 EXCEL 46 (SERVO HYDREX TH 46 PLUS), LUBE OIL SYNTHETIC SHELL RIMULA R4 15W4*, LUBE OIL AUTO GEAR SHELL SPIRAX S6 ATF*, LUBE OIL SYNTHETIC TES 668 GRADE FOR AL*, ... SILICON TRANSFORMER FLUID, ...
MICRO CCT 74 HC 00, GEAR BELT, MICRO CCT 74 HC 005, MICRO CCT LINEAR LM 317 BD, IC DAC 1271 A, IC SF DGTLCKT MM74C922M, COIL RF 330 MH, MICRO CCT LIENEAR TYPE REF 02 CS MICRO CCT VOLTAGE REF PLUS 5V, MICRO CCT LINEAR OP AMP QUAD TYPE MC 3303, DIODE, ... 10, TRANSFORMER POWER ...
Supply of SWITCH PLATE FOR COACHES as per item 1 of attached specification document, Supply of SWITCH PLATE ASSEMBLY FOR COACHES as per item 2 of attached specification document, Supply of SWITCH PLATE ASSEMBLY as per item 3 of attached specification ... KVA transformers as ...
Custom Bid for Services - Transportation of 1 no 500 MVA 400 kV ICT main tank Weight 260 T from POWERGRID Bongaigain SS Kokrajhar Dt to POWERGRID Mariani SS including road way Indicative Route Bongagion SS Jogighopa Road way and Silghat to Marian.., ... above Transformer Indicative ...
COPPER BUSH 8680731, SILVER CTC SHOE P 8642107, FILTER SET WITH CONNECTOR P 7356348, SOLENOID VALVE P 8843540, WELDING CYLINDER S WITH BARE P 8828450, WELDING CYLINDER F WITH BARE P 8828451, CYLINDER WITH TOGGLE CLAMP FIXTURE ASSEMBLY P 8823627, FLOW ... COOLED TRANSFORMER P ...
Rotary as per item 1 of attched specification document, Indicaiton lamp as per item 2 of attached specificaiton document, Recifier as per item 3 of attached specificaiton document, DC voltmeter asper item 4 of attached specificaiton document, Labor ... Control transformer as ...
1. Solid state over voltage relay for transformer rectifier unit of RMPU coaches. specn: Specification No: Drg. ICF Specification N0,ICF/Elect/897 Rev.O or latest.; 2. Insulation monitoring relay 110 volt AC, range 50 V to 200 V AC insulation measuring range 25 kilo ohm to 100 kilo ohm, control supply-230 volts, 50 Hz having fault memory test and reset button and alarm lead as per RCF specification EDTS-073 Rev d Amend 3. as per Drg.No. Nil specn: RCF specification EDTS-073 Rev d Amend 3; 3. MPCB, Current rating: 16 A, Thermal release range: 10-16 A, Class: 10, Breaking Capacity: 10kA, Pole: 3 P, Voltage Rating: 415 V AC conforming to RDSO spec. no. RDSO/PE/SPEC/AC/0184 %u2013 2015 (Rev. 0) as per Drg.No. Nil specn: RDSO spec. no. RDSO/PE/SPEC/AC/0184 %u2013 2015 (Rev. 0) 4. Set of thermal expansion valve suitable for LHB RMPU AC unit of 3.5 ton-conforming to RDSO Spec:-RDSO/PE/SPEC/AC/0061-2005(Rev.- 1) one set contains two valve. 1] SPORLAN-EBVE :7/8" x 1/4" for refrigerant R22 or equivalent of Danfoss/ALCO make. 2]ALCO-Tx3-H36:3/8" x 1/4" for refrigerant R22 or equivalent of Danfoss/SPORLAN make. as per Drg.No. Nil specn: RDSO/PE/SPEC/AC/0061-2005(Rev.-1) 5. Polychlorophene rubber pad (Grade - F) of size 240mm x 160mm x 18 + 0 - 1 mm for 'V' grooved axle pully of 4.5 KW alternators as per RDSO's Drg no. RDSO/PE/SK/TL/0084-2005(Rev. 0) & SKEL 3883 Alt. 5. The material should be as per laid down clause no 3.2, 4.1 & 3.2, 4.2 as mentioned in IRS.R - 48-88.
RES 1206 10K, TRANSISTOR SI LP PNP TYPE BCX71J, TRANSISTOR FEL N CHAN MRF 174, SEMICONDUCTOR DEVICE DIODE TYPE IN 5819, TRANSISTOR MOSFET N-CHAN TYPE IRFP460, TRANSISTOR N-CHANNEL MOS TYPE 2SK 2842/K, TRANSISTOR N-CHANNEL MOS TYPE KA 2611/2S, ... V, TRANSFORMER RF
Microscopes oil immersion, Demonstration eye piece, Double demonstration eye piece, Improved Neubauers chamber, Hemoglobinometer Sahli, Centrifuge high speed, Stage incubator, ESR stand with Westergren pipette, Wintrobes tube with stand, Clinical ... down transformer , ...
To Study Characteristics of DC Generator, To Study Load Test on Dc Shunt Motor and Plot the Following Characteristics of The Motor with Data Acquisition System with Software, To Study Load Test on DC Series Motor, To Study Load Test on DC Compound ... Phase Transformer Setup, ...
Copper Wire Polycab 2 and half SqMM, 16 Amp Socket or Board, Flex Printing with framing Size 8ftx10ft, Flex Printing with framing size 3ftx3ft and installation in 10 ft height, Flex Printing with framing size 3ftx8ft and installation in 10 ft height, ... Up Transformer Physics ...
Digital Multimeter, DC Voltmeter 0-25volts, DC Voltmeter 0-10volts, DC Multimeter 0-25Ma, DC Ammeter 0-3amp, Sodium Bulb with transformer for spectrometer, Mercury lamp with transformer, VI Characteristics of Solar cell trainer board, RC Coupled amplifier experiment trainer board, Dual Power Supply, Constant flow colorimeter, Meter Bridge of good quality, To determine Planck constant using LEDs, Plane diffraction Gratting, Bar pendulum, Kater Pendulum, Optical bench, Potentiometer, Determination of the young modulus of the material of a wire, Measurement of Susceptibility of paramagnetic Solution, Measurement of Magnetic Susceptibility, B-H Curve of Fe using solenoid and determine, To measure the resistivity of a semiconductor, Spectrometer, Searle thermal conductivity apparatus, De-Sauty Bridge trainer board, Determination of frequency of tuning fork, Copper connecting wires, Vernier Callipers, Prism, Fractional Resistance, Flywheel, Meter scale, Capillary tube, Key 1 way and 2way, Newton ring apparatus, Thermocouple trainer kit, Lee disc apparatus, Spirit level, Solar cell characteristic Apparatus, OPAMP, Tuning Fork, Carry foster bridge, Series and parallel LCR Circuit, Compass needle, experiment set up Thomson Method, Cathode Ray Oscilloscope, Geiger-Muller counter, Function Generator 10MHz, Screw gauge, Travelling Microscope, Rheostat, Sextant, Stop watch, Solenoid, P-N junction diode characteristic Apparatus, Resistance Box, Zener diode, He- Ne Laser, Diffraction grating with 1500 LPI, Digital Balance 2 Digit, Digital Balance 3 Digit, Digital PH Meter, Digital Colorimeter, Centrifuge Machine 6000 RPM, Water Distillation Plant, Refractometer, Laminar Air Flow, Magnetic Stirrer with Hot Plate, Muffle Furnace, Heating Mental with Regulator 500 ml, Melting Point Apparatus, UV Spectrophotometer, Hot Air Oven, Incubator, Refrigerator, Test Tube, Beaker 250ml, Beaker 500ml, Conical Flask 250ml, Chemical Thermometer, Round bottom flask 250 ml, Measuring Cylinder 50ml, Measuring Cylinder 100ml, Filter Paper, Burette 50ml, Pipette 25ml, Pipette 50ml, Bloating Paper, Flame Photometer, Electrical conductivity meter, Buchner Funnel, Polarimeter, Desiccators, Compound Microscope, Binocular Microscope, Autoclave 50 ltr, Deep Freezer 300 Ltr, Refrigerator 185 ltr, PH Meter, Digital Colony Counter, UV Spectrophotometer with Quartz Cuvette, BOD Incubator, Vortex Shaker for test tube, Orbital Shaker, Water Bath Digital, Inoculating loop, Bunsen Burner, Spirit lamp, Vernier Calipers, Ocular Micrometer, Stage Micrometer, Haemocytometer, Soil Thermometer, Anemometer, Lux meter, Dissolve Oxygen meter, Deep Freezer 300 Ltr Minus 20 Degree, Water Distillation Plant with automatic power cut, Trinocular Microscope, Centrifuge Rotor, Microtome Machine Bid Details 2/109