Loading…
Loading…
2,674 results • Best match
POSITIVE NAGATIVE LEAD, DIGITAL BP CUFF MACHINE, ADOPTER 5V 1AMP, BP CUFF DIGITAL, LED CURING LIGHT, SPO2 6 PIN CABLE, TEMPRETURE CONTROLLER, IC MICRO CONTROLLER, TRANSFORMER, THERMOSTATE CONTROLLER, ELBOW OXYGEN CONNERCTOR, BACTIRIA FILTER
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Office Space; Power House Equipment, Job work for urgent repairMaint to GOAB DO set for local transformer in main power house; Service Provider
Custom Bid for Services - Healthiness Testing of VCB Bottles as per IS code, Custom Bid for Services - Calibration of WTI OTI Relays of Transformer, Custom Bid for Services - Electromechanical relay Testing as per IS code, Custom Bid for Services - ... - Transformer Oil ... of Transformer oil ...
Supply and Fixing Transformer Gasket, Supply Backelit Sheet 4 mm, Fuse HPL LKDN-00 10 A, Fuse HPL LKDN-00 16 A, Fuse HPL LKDN-00 20 A, Fuse HPL LKDN-00 32 A, Fuse HPL LKDN-00 63 A, Fuse HPL LKDN-00 100 A, Relay Testing including Inbuilt Relay, ... FLP, Transformer oil ... testing, Transformer Oil ... of Transformer , ...
As tender Documents
Const of Control Room, Residential quarters, Civil Foundation, Cable trench, transformer track, levelling and dressing, boundary and fencing wall, grading and gravelling, vehicle stand, water harvesting an development work at 132 KV GSS Barkheda
Construction of Control Room Quarters Civil foundations Cable Trench Transformer Track Levelling and dressing Boundary wall Fencing Wall Grading and Gravelling Vehicle Stand Water Harvesting and development work at 132 KV GSS Lawan Dausa
AS DESCRIBED IN BILL OF QUANTITIES
Automatic Line Voltage Corrector Or Step Type Auto Transformer ( 8 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Ungrouped GENERIC Conforming to IS:8448 latest Yes * Rating in KVA 2.0 KVA 2.0 KVA ISI Marked No Yes, No ISI Marked if Yes CM/L No. (If No write NA) NA * Type of winding Aluminium Copper, Aluminium Input Single Phase sine wave (160V-260V) Single Phase sine wave (160V-260V), single Phase Sine wave (120V-280v) Display Type of Meter Digital Volt Meter analog Volt Meter, Digital Volt Meter CONSTRUCTIONAL Mounting Type Wall mounting * Current rating of the Relay/contactors (Amp) Conforming to IS:8448 latest * Overall weight of ALVC 6 * 1/3 (Kg) Provision of power supply cord/terminal as applicable for input and output as per IS:8448 Yes * FUNCTIONAL Output Single Phase sine wave (210V-250V) * Overall efficiency of ALVC (%) >/= 95% * The product shall conform to the acceptance tests as per Cl. 12.1.1 of IS:8448 latest Yes * CERTIFICATIONS Availability of Type Test Report from Central Govt. NABL/ILAC Accredited lab to prove conformity to the Specification IS:8448 latest Yes * Type Test report No. 42/962 * TTC report date 31/03/2017 * Name of Lab V Guard Industries Ltd * Address of Lab VENNALA HIGH SCHOOL ROAD VENNALA KOCHI * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Minakshi Jain 303702, MORIJA ROAD, BEHIND POWER HOUSE, CHOMU 8 15
HEATING ELEMENT 2 KW, HEATING ELEMENT 9 KW, 3 CORE CABLE, 3 PIN PLUG 15 AMP, 20 WATT LAMP, MERCURY FOR SPHYGMOMANOMETER, BLADDER FOR SPHYGMOMANOMETER, BP KNOB FOR SPHYGMOMANOMETER, CUFF FOR SPHYGMOMANOMETER, INDEX GLASS FOR SPHYGMOMANOMETER, BELLOW ... VALVE, TRANSFORMER FOR ... DESTROYER, TRANSFORMER FOR ...
Main PCB EWS, 3 Pin LED with Wire and 3 Pin SIL Conn, Transformer, Front Sticker 200Kg, Mother Card 200 KG EWS, Display Card EWS 200 Kg, EWS SMPS, SMPS EWS, Charger PCB DC 12V
The work of 11 KV line and transformer SS for PWD shifting work for deposit work under Assistant Engineer O and M Malpura as per ARC 2025 in the Jurisdiction of Tonk Circle Jaipur Discom
Supply of various types of 132 kv Current Transformer terminal clamps, Bus isolator Clamp, Bimetallic strip, Aluminum Base, Copper- Brass Terminal End Clamp and Jaw Assembly and associated accessories for 132 KV switchyard at RPSPS, JSPS.
as per tender document
As per tender documents
Cover Outer tubeless type 235-70-R16 TATA Xenon, Cover Outer 7.00-16-14 PR TATA 207 DI, Cover Outer 7.50-16-16 PR EICHER, Cover Outer tubeless type 168-80 R 14 Suzuki dzire, Cover Outer 9.00-20-12 PR Trolly Transformer, Cover Outer 9.00-16-16 PR ... Trolly Transformer , ...
Cover Outer tubeless type 235-70-R16 TATA Xenon, Cover Outer 7.00-16-14 PR TATA 207 DI, Cover Outer 7.50-16-16 PR EICHER, Cover Outer tubeless type 168-80 R 14 Suzuki dzire, Cover Outer 9.00-20-12 PR Trolly Transformer, Cover Outer 9.00-16-16 PR ... Trolly Transformer , ...
Work of cleaning of Control room Turbine area Service Building Administrative Building Transformer yard Common Area Auxiliary Area store office switchyard control room fire station and its associated buildings of unit 7 8 (2X660 MW) at SSCTPS
Online UPS Online UPS ( 6 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 1.0 KVA 1.0kva Technology MOSFET-PWM with inbuilt isolation transformer mosfet-pwmwithinbuilti solationtransformer Input Power single phase 160V - 260V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 30 30 Minimum VAH (VAH) 800 Warranty for UPS (Years) 1 1, 2, 3, 4, 5 Movable trolly for Batteries Without With, Without, Without trollery but with rack Warranty for battery 1 1, 2 Degree of Protection IP21 IP21, IP20 1/4 Cabling 5 meters for input and out put With with Paralleling kit for synchronising Without With, Without Installation and Commissioning Yes N/A CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 N/A Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) N/A FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 N/A Voltage Regulation from no load to full load (%) /= 3% N/A 20% Overload limit for minimum 10 minutes Yes N/A Overall Efficiency (%) >/=90% N/A Total Harmonic Distortion(THD) (%) Maximum 3% N/A 50% Overload limit for minimum 1 minutes Yes N/A PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes N/A Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes N/A METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Battery Voltage and Current Yes N/A Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes N/A REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 Yes N/A 2/4 degree C, two cycles of (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes N/A Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes N/A Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes N/A Type Test Certificate No. R-41018082 N/A Type Test Certificate date 2017 N/A Name of Lab BIS N/A Address of Lab BIS N/A As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Radhe Shyam Meena 334001, Off.Airport Director, AAI, Civil Airport, Nal Bikaner 6 15 EMD Required No ePBG Required No 3/4
Supply of Motor Protection Relays, Supply of Motor prot. relay with Diff. Protection, Supply of Transformer Feeder protection relays, Supply of Tie Feeder protection relays, Supply of DG feeder protection relays, Supply of Portable evaluation ... of Transformer Feeder ...
ERECTION OF 11 KV LINE SS AND TRANSFORMER FOR RELEASING OF ELECTRICITY CONNECTION IN FAVOUR OF SENIOR DIVISIONAL ELECTRICAL ENGINEER, AGRA DIVISION, NORTH CENTRAL RLY AT MOHARI, GADI SANDARA, RANPUR etc on ARC under AEN BARI OF DHOLPUR CIRCLE
Bty lead 16mm Red cover, Bty lead 16mm Black, Bridge rectifier, Step down transformer, Fuse cartridge 10 Amp, Earthing brade, Bty terminal, Indication lamp DC, Indication lamp AC, Carbon brush Set, IAVR BOQ Title BOQ ORD Bty Lead Item 11
TOGGLE SWITCH SPST 10A (Q3), RECTOFIER CONTROL CARD (Q3), CAPACTOR 20 MFD/400 V (Q3), POTENTION METER 1K/3K/5K/10K (Q3), SHUNT 25 AMP 75 MV (Q3), DRIVER BELT (Q3), MASTER CYLINDER ASSY (Q3), RECTIFIER CONTROL SUPPLY TRANSFORMER (Q3)
Contactor K44 for 60 KVA Transformer, Rated current: 95 Amps, Rated Voltage: 690 V AC, Main pole: 4, Aux contact: 1NO + 1NC Control voltage: 230 V AC (168 V AC- 300 V AC means 230 V AC +/- 30 Percent) with surge suppressor as per RDSO Spec No. RDSO/PE/SPEC/ AC/0184-2015 (Rev - 1) or latest and as per update of common BOM items issued by RDSO Lr.No. EL/7.1.108/MSSBC, dt 17/09/21 or latest, to ABB Model no. AF 116B-40, Schneider Model no. LC1D1150046M5 + LA4DA2U, C&S model no. LC1FDP1154U5+LA9F980 (BR) only accepted.
SITC FLOW METER, OFC CABLE SUPPLY, OFC CABLE LAYING, HDPE PIPE SUPPLY, HDPE PIPE LAYING, OFC TERMINATION, SITC PANEL CABINET, NETWORK SWITCH 12 PORT, NETWORK SWITCH 8 PORT, MEDIA CONVERTER 18 PORT, MEDIA CONVERTER 6 PORT, SFP PATCH CODE, FIBRE GLASS ... GAUGE, TRANSFORMER SERVICE, ... LIGHT, TRANSFORMER OIL ...
fabrication of sub-station structure set for mounting of 11/0.4 KV transformer on double pole, 1.4 Mtr long MS channel bracket with clamp and 11 KV Cross arm (Angle) with clamp and Top hamper including transportation and unloading of steel from stock
fabrication of sub-station structure set for mounting of 11/0.4 KV transformer on double pole, 1.4 Mtr long MS channel bracket with clamp and 11 KV Cross arm (Angle) with clamp and Top hamper including transportation and unloading of steel from stock
Shifting of 250KV transformer , replacement of 33KV and 11KV O/H line into U/G Cable at Puliya No. 2 , Opposite 33 / 11 KV Idgah S/S , Delhi Road , in the area of AEN HTM V,City Circle,Jaipur on Labour Rate
Comprehensive Annual Maintenance and Operation of CCTV, PA and Fire Alarm System including POL for DG Set at AD and MA Office and providing operators for these services at Hawa Mahal, Jantar Mantar and Esar Lat, Jaipur
Sarv Dharm sthal 02 No central Morcha02 No Corner Bunkers02 No 2 Men Bunker Dog Kennel development works Bulk Services Providing 02 Nos 40 KVA DG Sets and SITC of 11 KV433 Volt 3 phase transformer 63 KVA rating RO Plant 100 LPH Perimete
SUPPLY OF COMBINE TRANS CT and TRANS PT OUTDOOR OIL IMMERSED FOR MDPL AJMER As per SOJ and Techanical Specifications , SUPPLY OF COMBINE TRANS CT and TRANS PT OUTDOOR OIL IMMERSED FOR MDPL AWA As per SOJ and Techanical Specifications , SUPPLY OF ... VOLTAGE TRANSFORMER FOR ... VOLTAGE TRANSFORMER FOR ...
Sarv Dharm sthal 02 No central Morcha 02 No Corner Bunkers 02 No 2 Men Bunker Dog Kennel development works Bulk Services Providing 02 Nos 40 KVA DG Sets and SITC of 11 KV433 Volt 3 phase transformer 63 KVA rating RO Plant 100 LPH Perimete
Sarv Dharm sthal, 01 No central Morcha 02 No Corner Bunkers 01 No 2 Men Bunker Dog Kennel development works Bulk Services Providing 02 Nos 40 KVA DG Sets and SITC of 11 KV433 Volt 3 phase transformer 63 KVA rating RO Plant 100 LPH Perimete
Stud Cyl Head Short M14X1.5X32, Stud Cyl Head Long M14X1.5X345, Bearing Set Sleeve Std Size, Brg Set Sleeve, Switch Pressure Low Lub Oil, Seal Oil 100x120x14, Gasket 229x268x0.798mm, Crank Shaft, Gear Crank Shaft, Spacer 65 OD X42, Transformer Power Step, Rectifier Assy Complete With, Auto Voltage Regulator
Custom Bid for Services - SERVICES FOR ROUND THE CLOCK OPERATION MAINTENANCE OF ELECTRICAL ASSETS FOR JAIPUR HQ, Custom Bid for Services - PROVIDING SERVICES OF SUPERVISOR FOR OPERATION AND MAINTENANCE OF ELECTRICAL ASSETS AT JAIPUR, Custom Bid for ... FOR TRANSFORMERS , ...
0V-230V-400V, Sy-23V-0V-23V, Control Transformer KAB1426, Py- Voltage 415V, Sy Voltage-230V, Control Transformer KAB2742, Py- Voltage 415V, Sy Voltage-230V, Measurement CT 250-5A, 10VA, Connectors CTS2.5 with end plate, end clamp 10ways, Connectors ... Main Transformer 3Ph, ... Input, Transformer KAB ... Input, Transformer KAB ... Inverter Transformer KAB ... Output Transformer 6KVA, ... Main Transformer 3Ph, ... Supply Transformer KAB ... Main Transformer 3Ph. ... Main Transformer 3Ph ... Output Transformer 80KVA, ... Output Transformer 10KVA, ... Main Transformer 3Ph. ...
WASTE INK PAD, LOGIC CARD, HEAD ASSY EPSON, SMPS SPECIAL PORT, IMAGE UNIT DR B021, IMAGE UNIT DL 412, BTY 12V 7AH, RAM 8GB DDR IV, PRESSURE ROLLER, TEFLON, PICKUP ROLLER, TRANSFORMER UPS, PROCESSOR I3 10TH GEN, COMBO KEYBOARD AND MOUSE, MOTHERBOARD H510, UPS 1KVA, DATA CABLE, LOGIC CARD HP, OPC DRUM, PCR ROLLER, CLEANING BLADE
ac static watthour meters-Energy meter Ac Static Watthour Meters-Energy Meter ( 1143 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Number of phases single phase two wire single phase two wire Reference ... Current Transformer No ...
MOTOR REPAIR CHARGES, PI Testing, IR Testing, Thermography, ACB VCB tesing, Relay testing, Transformer Oil filtration and oil sample testing, Insulation mat, LOAD TESTING OF BATTERY BANK, Calibration of equpiments, EXPLOSIVE METER MULTI GAS, ... PUMP, TRANSFORMER WTI ... OF TRANSFORMER , ... OF TRANSFORMER , ... OF TRANSFORMER , ... OF TRANSFORMER , ...
Raspberry Pi Three, Arduino UNO, Sensor and Timer Circuit, Buck convertor and rectifier and filter, frequency generator, Buzzer, LCD display, Power supply transformer, Micro SD Card 64 GB, Bread board and jumper wire, USB Cable for Arduino, Raspberry Pi Zero two watt, Pi Camera, Alcohol Sensor, DC Motor Small, Buzzer Magnetic, Rectifier and filter, Pi Zero camera ribbon, USB to TTL Serial Cable
Z6-ARJ-100609 Snubber Card MTRL NO 10423913, Z6-MISC- 23386 Oil Pump Cover MTRL NO 10546943, Z6-ARJ-100144 Sloted Cheese Head Screw MTRL NO 10424907, Z6-ARJ- 100607 Transformer Card MTRL NO 10424014, Z6-ARJ- 100903 Micro Controller Card MTRL NO 10451680, Z6-ARJ- 100919 Key Board MTRL NO 10451688, Z6-ARJ-100925 Starting Key MTRL NO 10451853
Radial Drilling Machine (Q3), Milling Machine-IS:6893, IS:8614, IS:9474 (Q2), Hand Operated Shearing Machine (Q3), Pedestal Grinder (Q3), Hand Operated Hydraulic Pipe Bender (Q3), Power Hacksaw Machine (Q3), Portable Gas Cutting Machine With ... welding transformers - ...
Custom Bid for Services - Providing Electrician, Custom Bid for Services - 4Transformer BDV DGA TAN Delta TestingEach2, Custom Bid for Services - 5Filteration Of Transformer OILEach2, Custom Bid for Services - Supply of hand gloves Similar Category Operation and Maintenance Of Electrical Systems/Electrical Installations Operation and Maintenance Of Electrical Systems/Electrical Installations Operation and Maintenance Of Electrical Systems/Electrical Installations Operation and Maintenance Of Electrical Systems/Electrical Installations
coolent, filter, oil, battery, repari job, earthing, tightening of nut bolts, tightening of bushing, cleaning of dust, replacement of jumpers, LT side bushing rod, HT side bushing rod, LT side porcelain bushing, HT side porcelain bushing, 40p cover ... connectors, transformer fresh ...
I7 12th Gen 16GB DDR4 RAM 1TB SATA HDD PC, HD studio 360 degree camera with auto zoom facility, 4K Resolution with 300x Zoom Visualiser, Main display of 85 inch Crystal UHD, Motorised Map Dispenser system, Interactive Podium with Integrated Control ... Battery, Transformer Based ...
Custom Bid for Services - 1CAMC FOR POWER ONE MAKE 20 KVA UPS UNIT INCLUDING BATTERY BANK INSTALLED FOR NEW SECURITY RECEPTION BUILDING AT ADA HQ COMPLEX AS PER DETAILED SCOPE OF WORK IS ENCLOSED IN APPENDIX A FOR THE PERIOD OF 01 YEAR, Custom Bid ... ISOLATION TRANSFORMER IT ... ISOLATION TRANSFORMER INSTALLED ... ISOLATION TRANSFORMER SERVO ...
Vacuum Pressure Transmitter, Generator Relay, Steam control valve Actuated Globe Valve, Absorber side NRV, Refrigerant Level electrode assembly, Solenoid Angle Valve, Rupture Disk, Purge pump 0.75 KW, Refrigerant pump 1.5 KW, Control Relay 220V AC, ... Control transformer 2000VA, ...
34700031 ROCKER SWITCH ON and OFF, 36G00035 POTENTIOMETER 470 K, E25 101042 1 PCB 3PIN, 34700112 RESET SWITCH P and C, 34700034 FEED SWITCH RED, 500405 BELT M 28 C, 44100197 FEED BELT K 19 P and C, 5S300002 EXIT GUIDE ADJUSTABLE 6 15MM, 5S300133 ... 08 TRANSFORMER HEATER ...
Supply of lightning arrestors with insulating base fittings etc. as per specifications. For 30 kV rated voltage, Highest system voltage 36 KV, 10 KA lightening arrestors, ISOLATOR Supply of 3 poles, centre post rotating type, offload motarized ... numerical Transformer Differential ... class, Transformer TAP ...
DC Spike Protection Capacitors 0.47mfd, 1200V, Capacitors 0.1mfd, 630V AC, CTR, MOV V275LA40AP, Little fuse, 25A EMI Filter Part No MF430, Rating 25A, 225V DC, EMIS, Capacitor having Type No PG-6D1, Size 76 mm x 145 mm, 6800 micro farad, 350 V ALCON, ... Control Transformer KAB ...